Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Forensic Sci Int ; 325: 110884, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34245937

RESUMEN

New psychoactive substances are being launched in the drug market at a rapidly growing pace. More than 950 new psychoactive substances have been reported to the United Nations Office on Drugs and Crime. The development of new psychoactive substance abuse has drawn risks on public health and safety. Phenethylamines, along with other stimulants, accounted for the majority of the new psychoactive substances being reported in the past decade. This study presents a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous screening of 74 conventional and artificial phenethylamines in urine samples. The chromatographic analysis was performed by a direct dilute-and-shoot procedure using a Phenomenex Kinetex® Phenyl-Hexyl column (10 cm × 2.1 mm i.d., 1.7 µm) and two mobile phases (A: 0.1% formic acid aqueous solution with 5 mM ammonium acetate, B: 0.1% formic acid methanolic solution). The mass fragments were collected under the multiple reaction monitoring mode. The linearity range located in 1.0-50.0 ng/mL for quantitative analysis. The limit of detection and lower limit of quantification for 74 phenethylamines were 0.5 ng/mL and 1.0 ng/mL, respectively. The method was validated and further applied to analyze authentic urine samples. Twenty samples were tested positive of seven phenethylamines from 67 samples, whereas the contents detected were 9.8 ng/mL to 147.1 µg/mL with dilution factors of 40 to 20,000 folds.


Asunto(s)
Drogas Ilícitas/orina , Fenetilaminas/orina , Psicotrópicos/orina , Cromatografía Liquida , Humanos , Reproducibilidad de los Resultados , Detección de Abuso de Sustancias , Espectrometría de Masas en Tándem
2.
Forensic Sci Int ; 315: 110429, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32784041

RESUMEN

Synthetic cathinones, which are a group of ß-keto analogs of phenethylamine, have been reported as the most emerging new psychoactive substances in the past decade. The quantity and variety of synthetic cathinones have continued to increase, which poses considerable risks to public health and social security. In this study, an analytical method based on liquid chromatography-tandem mass spectrometry (LCMS/MS) was established for the simultaneous determination of 73 synthetic cathinones and related metabolites in urine. The chromatographic analysis was performed using a Kinetex® Biphenyl column (10 cm ×2.1 mm, 1.7 µm), applying a gradient mobile phase, comprising 0.1 % formic acid aqueous solution with 5 mM ammonium acetate and 0.1 % formic acid methanolic solution; the entire run time of the analysis was within 8 min. The multiple reaction monitoring (MRM) mode was employed to collect the monitoring and quantitative ion pairs. Intra-day/inter-day precision and accuracy were less than 10 % for all the studied analytes. The limits of detection and quantification for all the analytes were 0.1-0.5 ng/mL and 0.5-1.0 ng/mL, respectively. The matrix effect was satisfactory for all the analytes, with a deviation lower than 20 %. The present method was further applied to 67 authentic urine samples in which 13 different synthetic cathinones were detected from 32 positive samples. The abuse of poly-synthetic cathinones was examined that up to seven items was detected in one case from authentic samples in this study.


Asunto(s)
Alcaloides/orina , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Psicotrópicos/orina , Detección de Abuso de Sustancias/métodos
3.
J Anal Toxicol ; 40(1): 12-6, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26410364

RESUMEN

In recent years, the abuse of synthetic cathinones has increased considerably. This study proposes a method, based on gas chromatography/mass spectrometry (GC-MS), to analyze and quantify six synthetic cathinones in urine samples: mephedrone (4-MMC), methylone (bk-MDMA), butylone, ethylone, pentylone and methylenedioxypyrovalerone (MDPV). In our procedure, the urine samples undergo solid-phase extraction (SPE) and derivatization prior to injection into the GC-MS device. Separation is performed using a HP-5MS capillary column. The use of selective ion monitoring (SIM mode) makes it is good sensitivity in this method, and the entire analysis process is within 18 min. In addition, the proposed method maintains linearity in the calibration curve from 50 to 2,000 ng/mL (r(2) > 0.995). The limit of detection of this method is 5 ng/mL, with the exception of MDPV (20 ng/mL); the limit of quantification is 20 ng/mL, with the exception of MDPV (50 ng/mL). In testing, the extraction performance of SPE was between 82.34 and 104.46%. Precision and accuracy results were satisfactory <15%. The proposed method was applied to six real urine samples, one of which was found to contain 4-MMC and bk-MDMA. Our results demonstrate the efficacy of the proposed method in the identification of synthetic cathinones in urine, with regard to the limits of detection and quantification. This method is highly repeatable and accurate.


Asunto(s)
Drogas de Diseño/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Detección de Abuso de Sustancias/métodos , 3,4-Metilenodioxianfetamina/análogos & derivados , 3,4-Metilenodioxianfetamina/orina , Acetona/análogos & derivados , Acetona/orina , Anfetaminas/orina , Benzodioxoles/orina , Calibración , Etilaminas/orina , Cromatografía de Gases y Espectrometría de Masas/normas , Humanos , Límite de Detección , Metanfetamina/análogos & derivados , Metanfetamina/orina , Pirrolidinas/orina , Reproducibilidad de los Resultados , Extracción en Fase Sólida , Detección de Abuso de Sustancias/normas , Urinálisis , Cathinona Sintética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA