Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 559
Filtrar
1.
Br Poult Sci ; 65(2): 111-118, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38230423

RESUMEN

1. 'Congenital loco' is a disorder in birds expressed at hatching, and the primary symptom is dorsal backward bending of the neck. It is a recessive disease caused by a mutation in a specific genetic locus. The following study identified a novel locus associated with congenital loco in Silkie Fowl chickens.2. Normal and congenital loco-affected Silkie Fowl chicks exhibited no differences in the frequencies of markers on chromosome 12 adjacent to the congenital loco locus reported in a previous study in Rhode Island Red chickens. Sex determination of congenital loco-affected chicks revealed that they were female only.3. Bulked segregant analyses using next-generation sequencing narrowed the causative region of congenital loco to approximately 3.3 Mb between bases 9,569,012 and 12,863,792 on chromosome Z.


Asunto(s)
Pollos , Cromosomas , Animales , Femenino , Masculino , Pollos/genética , Mapeo Cromosómico/veterinaria
2.
Tech Coloproctol ; 26(9): 735-743, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35676544

RESUMEN

BACKGROUND: We carried out robot-assisted lateral pelvic lymph node dissection (LPLND) for rectal cancer with a stereotactic navigation system. The purpose of this study was to evaluate the accuracy and feasibility of the system. METHODS: We constructed a navigation system based on the Polaris Spectra optical tracking device (Northern Digital Inc., Canada) and the open-source software 3D Slicer (version 3.8.1; http://www.slicer.org ). We used the landmark-based registration method for patient-to-image registration. Body surface landmarks and intra-abdominal landmarks were used. We evaluated the time required for registration and target registration error (TRE; the distance between corresponding points after registration) for the root of the superior gluteal artery the root of the obturator or superior vesical artery, and the obturator foramen during minimally invasive LPLND for rectal cancer. Five patients who had LPLND for rectal cancer at the University of Tokyo Hospital between September 2020 and May 2021 were enrolled. RESULTS: The mean time required for registration was 49 s with the body surface landmarks and 88 s with the intra-abdominal landmarks. The mean TRE improved markedly when the registration was performed using intra-abdominal landmarks. The mean TRE of the root of the superior gluteal artery, the root of the obturator or superior vesical artery, and the obturator foramen were 55.8 mm, 53.4 mm, and 55.2 mm with the body surface landmarks and 11.8 mm, 10.0 mm, and 12.6 mm with the intra-abdominal landmarks, respectively. There were no adverse events related to the registration process. CONCLUSIONS: When stereotactic navigation systems are used for minimally invasive LPLND, the use of intra-abdominal landmarks for registration is feasible and may allow simpler and more accurate navigation than the use of body surface landmarks.


Asunto(s)
Neoplasias del Recto , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Imagenología Tridimensional , Escisión del Ganglio Linfático/métodos , Pelvis/patología , Pelvis/cirugía , Neoplasias del Recto/cirugía , Cirugía Asistida por Computador/métodos
3.
Radiography (Lond) ; 28(3): 725-731, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35428571

RESUMEN

INTRODUCTION: Many patients experience anxiety, not limited to claustrophobia, before magnetic resonance imaging (MRI) examination. We performed a non-randomized controlled trial to evaluate whether a patient-friendly audiovisual (AV) system in the MR scanner room reduces patient anxiety. METHODS: We randomly selected 61 participants from outpatients who required brain MRI examination. Patients were informed that they could choose to undergo an MRI examination with a patient-friendly AV system (Ambient Experience, Philips Healthcare, Best, The Netherlands) or the standard system. To complete the MRI examination without affecting clinical practice, all patients who preferred the patient-friendly AV system were assigned to the preferring AV group. Patients who indicated that either system was acceptable were randomly assigned to the no preference but allocated AV group or control (using the standard system) groups. In both groups, state anxiety using the State-Trait Anxiety Inventory (STAI) was assessed before and after the MRI examination (A-State-before and A-State-after MRI, respectively). The changes in A-State-before and A-State-after MRI were categorized as follows: relieved high-state anxiety, no change in high-state anxiety, stable easiness, and intensified anxiety. RESULTS: Among the 61 included patients, 19 were assigned to the preferring AV group, 20 to the no preference but allocated AV group, and 22 to the control group. There were no significant differences between the group. However, in patients with high-state anxiety before MRI, the preferring AV group and the no preference but allocated AV group, which used the patient-friendly AV system, relieved high-state anxiety by 63.6% (7 of 11 patients) and 81.8% (9 of 11 patients), respectively. In contrast, the control group using the standard system relieved high-level anxiety by only 42.9% (three out of seven patients). CONCLUSION: The patient-friendly AV system may reduce anxiety in patients undergoing MRI examinations. IMPLICATIONS FOR PRACTICE: The patient-friendly AV system may reduce anxiety in patients undergoing MRI examination by providing a more patient-centered MRI examination environment. These findings may help ameliorate negative perceptions associated with MRI examination.


Asunto(s)
Ansiedad , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Países Bajos
4.
Sci Rep ; 11(1): 5964, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33727581

RESUMEN

In functional near infrared spectroscopy (fNIRS), deconvolution analysis of oxy and deoxy-hemoglobin concentration changes allows estimating specific hemodynamic response functions (HRF) elicited by neuronal activity, taking advantage of the fNIRS excellent temporal resolution. Diffuse optical tomography (DOT) is also becoming the new standard reconstruction procedure as it is more accurate than the modified Beer Lambert law approach at the sensor level. The objective of this study was to assess the relevance of HRF deconvolution after DOT constrained along the cortical surface. We used local personalized fNIRS montages which consists in optimizing the position of fNIRS optodes to ensure maximal sensitivity to subject specific target brain regions. We carefully evaluated the accuracy of deconvolution when applied after DOT, using realistic simulations involving several HRF models at different signal to noise ratio (SNR) levels and on real data related to motor and visual tasks in healthy subjects and from spontaneous pathological activity in one patient with epilepsy. We demonstrated that DOT followed by deconvolution was able to accurately recover a large variability of HRFs over a large range of SNRs. We found good performances of deconvolution analysis for SNR levels usually encountered in our applications and we were able to reconstruct accurately the temporal dynamics of HRFs in real conditions.


Asunto(s)
Corteza Cerebral/irrigación sanguínea , Corteza Cerebral/fisiopatología , Hemodinámica , Espectroscopía Infrarroja Corta , Adulto , Algoritmos , Mapeo Encefálico/métodos , Corteza Cerebral/metabolismo , Femenino , Voluntarios Sanos , Hemoglobinas/metabolismo , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Modelos Teóricos , Actividad Motora , Oxígeno/metabolismo , Espectroscopía Infrarroja Corta/métodos , Tomografía Óptica/métodos , Adulto Joven
5.
Bone Joint J ; 101-B(6): 745-752, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31154837

RESUMEN

AIMS: The purpose of this study was to clarify the clinical behaviour, prognosis, and optimum treatment of dedifferentiated low-grade osteosarcoma (DLOS) diagnosed based on molecular pathology. PATIENTS AND METHODS: We retrospectively reviewed 13 DLOS patients (six men, seven women; median age 32 years (interquartile range (IQR) 27 to 38)) diagnosed using the following criteria: the histological coexistence of low-grade and high-grade osteosarcoma components in the lesion, and positive immunohistochemistry of mouse double minute 2 homolog (MDM2) and cyclin-dependent kinase 4 (CDK4) associated with MDM2 amplification. These patients were then compared with 51 age-matched consecutive conventional osteosarcoma (COS) patients (33 men, 18 women; median age 25 years (IQR 20 to 38)) regarding their clinicopathological features. RESULTS: The five-year overall survival (OAS) rates in the DLOS and COS patients were 85.7% and 77.1% (p = 0.728), respectively, and the five-year progression-free survival (PFS) rates were 57.7% and 44.9% (p = 0.368), respectively. A total of 12 DLOS patients received chemotherapy largely according to regimens for COS. Among the nine cases with a histological evaluation after chemotherapy, eight showed a poor response, and seven of these had a necrosis rate of < 50%. One DLOS patient developed local recurrence and five developed distant metastases. CONCLUSION: Based on our study of 13 DLOS cases that were strictly defined by histological and molecular means, DLOS showed a poorer response to a standard chemotherapy regimen than COS, while the clinical outcomes were not markedly different. Cite this article: Bone Joint J 2019;101-B:745-752.


Asunto(s)
Neoplasias Óseas/patología , Neoplasias Óseas/terapia , Osteosarcoma/patología , Osteosarcoma/terapia , Adulto , Biomarcadores de Tumor/análisis , Estudios de Casos y Controles , Terapia Combinada , Femenino , Humanos , Inmunohistoquímica , Masculino , Clasificación del Tumor , Estudios Retrospectivos , Tasa de Supervivencia
6.
J Neurosci Methods ; 309: 91-108, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30107210

RESUMEN

BACKGROUND: Application of functional Near InfraRed Spectroscopy (fNIRS) in neurology is still limited as a good optical coupling and optimized optode coverage of specific brain regions remains challenging, notably for prolonged monitoring. METHODS: We propose to evaluate a new procedure allowing accurate investigation of specific brain regions. The procedure consists in: (i) A priori maximization of spatial sensitivity of fNIRS measurements targeting specific brain regions, while reducing the number of applied optodes in order to decrease installation time and improve subject comfort. (ii) Utilization of a 3D neuronavigation device and usage of collodion to glue optodes on the scalp, ensuring good optical contact for prolonged investigations. (iii) Local reconstruction of the hemodynamic activity along the cortical surface using inverse modelling. RESULTS: Using realistic simulations, we demonstrated that maps derived from optimal montage acquisitions showed, after reconstruction, spatial resolution only slightly lower to that of ultra high density montages while significantly reducing the number of optodes. The optimal montages provided overall good quantitative accuracy especially at the peak of the spatially reconstructed map. We also evaluated real motor responses in two healthy subjects and obtained reproducible motor responses over different sessions. COMPARISON WITH EXISTING METHODS: We are among the first to propose a mathematical optimization strategy, allowing high sensitivity measurements. CONCLUSIONS: Our results support that using personalized optimal montages should allow to conduct accurate fNIRS studies in clinical settings and realistic lifestyle conditions.


Asunto(s)
Mapeo Encefálico/métodos , Corteza Cerebral/fisiología , Espectroscopía Infrarroja Corta/instrumentación , Espectroscopía Infrarroja Corta/métodos , Mapeo Encefálico/instrumentación , Simulación por Computador , Electrodos , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Neuronavegación , Reproducibilidad de los Resultados , Cuero Cabelludo/fisiología
7.
Phys Chem Chem Phys ; 20(7): 4962-4969, 2018 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-29387834

RESUMEN

Cationic disorder in the MgAl2O4 spinel induced by swift heavy ions was investigated using the X-ray absorption near edge structure. With changes in the irradiation fluences of 200 MeV Xe ions, the Mg K-edge and Al K-edge spectra were synchronously changed. The calculated spectra based on density function theory indicate that the change in the experimental spectra was due to cationic disorder between Mg in tetrahedral sites and Al in octahedral sites. These results suggest a high inversion degree to an extent that the completely random configuration is achieved in MgAl2O4 induced by the high density electronic excitation under swift heavy ion irradiation.

8.
mSphere ; 3(1)2018.
Artículo en Inglés | MEDLINE | ID: mdl-29435490

RESUMEN

Increasing evidence shows that exosomes are key regulators in cancer cell-to-cell communication. Several reports on Epstein-Barr virus (EBV)-related malignancies demonstrate that latent membrane protein 1 (LMP1) secreted by exosomes derived from EBV- or LMP1-positive cells can promote cancer progression and metastasis. However, the mechanism by which LMP1 is loaded into exosomes is still poorly understood. Here, we examined whether the process of LMP1 loading into exosomes is linked to the multifunctional molecule of the ubiquitin system-ubiquitin C-terminal hydrolase-L1 (UCH-L1). For the first time, we demonstrate that LMP1 is physically associated with UCH-L1 and that directing of LMP1 to exosomes is mediated by C-terminal farnesylation of UCH-L1. Additionally, we found that the FTI-277 farnesyltransferase inhibitor reduces motility- and anchorage-independent growth of EBV-positive cells in functional assays. On the basis of our results, we conclude that C-terminal farnesylation of UCH-L1 is one of the key mechanisms by which LMP1 is sorted to exosomes. We hypothesize that inhibition of farnesylation with specific small-molecule inhibitors blocks exosome-mediated transfer of prometastatic molecules such as LMP1 during cancer cell-to-cell communications and thereby impedes the process of cancer invasion. IMPORTANCE Exosomes are small vesicles that cells secrete into the extracellular space, and there is increasing evidence that they have pivotal roles in cell-to-cell communication in malignancy. It is reported also that EBV-associated malignant cells, including those derived from nasopharyngeal carcinoma (NPC) and B-cell lymphoma, secrete exosomes. These EBV-related exosomes may contain viral products such as latent membrane protein 1 (LMP1) and may contribute to cancer progression. The aim of this study was to investigate the mechanism by which those viral products are loaded in exosomes. In this study, we show for the first time that ubiquitin C-terminal hydrolase-L1 (UCH-L1) and its C-terminal farnesylation, a posttranslational lipid modification, contribute to this mechanism. Our results also suggest that inhibition of UCH-L1 farnesylation is a potential therapeutic target against cancer metastasis and invasion.

9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 3240-3243, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29060588

RESUMEN

Laparoscopic pelvic lymph node dissection is a delicate operation because pelvic arteries, which should be located first to guide the dissection, are often concealed by tissues and cannot be identified in the endoscopic view. Consequently, arteries can be damaged if they are not located accurately. To improve dissection safety and efficiency, we have developed an image-guided navigation system to provide pelvic artery position information by registering a 3D artery model extracted from CT images to a 3D model reconstructed from free-hand laparoscopic ultrasound images. The ultrasound probe is tracked using a proposed stereo vision-based tracking strategy that can simplify the system and reduce setup time. The artery is segmented from 2D ultrasound images using a local phase-based snakes framework. The accuracy of the proposed navigation system was estimated in a phantom experiment (the TRE error was 1.58 ± 0.70 mm), and the feasibility of the proposed navigation system was confirmed in an animal experiment.


Asunto(s)
Laparoscopía , Animales , Imagenología Tridimensional , Escisión del Ganglio Linfático , Fantasmas de Imagen , Ultrasonografía
10.
Neuroimage ; 157: 531-544, 2017 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-28619655

RESUMEN

BACKGROUND: The present study aims at evaluating and comparing electrical and magnetic distributed source imaging methods applied to high-density Electroencephalography (hdEEG) and Magnetoencephalography (MEG) data. We used resolution matrices to characterize spatial resolution properties of Minimum Norm Estimate (MNE), dynamic Statistical Parametric Mapping (dSPM), standardized Low-Resolution Electromagnetic Tomography (sLORETA) and coherent Maximum Entropy on the Mean (cMEM, an entropy-based technique). The resolution matrix provides information of the Point Spread Functions (PSF) and of the Crosstalk functions (CT), this latter being also called source leakage, as it reflects the influence of a source on its neighbors. METHODS: The spatial resolution of the inverse operators was first evaluated theoretically and then with real data acquired using electrical median nerve stimulation on five healthy participants. We evaluated the Dipole Localization Error (DLE) and the Spatial Dispersion (SD) of each PSF and CT map. RESULTS: cMEM showed the smallest spatial spread (SD) for both PSF and CT maps, whereas localization errors (DLE) were similar for all methods. Whereas cMEM SD values were lower in MEG compared to hdEEG, the other methods slightly favored hdEEG over MEG. In real data, cMEM provided similar localization error and significantly less spatial spread than other methods for both MEG and hdEEG. Whereas both MEG and hdEEG provided very accurate localizations, all the source imaging methods actually performed better in MEG compared to hdEEG according to all evaluation metrics, probably due to the higher signal-to-noise ratio of the data in MEG. CONCLUSION: Our overall results show that all investigated methods provide similar localization errors, suggesting very accurate localization for both MEG and hdEEG when similar number of sensors are considered for both modalities. Intrinsic properties of source imaging methods as well as their behavior for well-controlled tasks, suggest an overall better performance of cMEM in regards to spatial resolution and spatial leakage for both hdEEG and MEG. This indicates that cMEM would be a good candidate for studying source localization of focal and extended generators as well as functional connectivity studies.


Asunto(s)
Mapeo Encefálico/normas , Corteza Cerebral/fisiología , Electroencefalografía/normas , Magnetoencefalografía/normas , Adulto , Estimulación Eléctrica , Entropía , Femenino , Humanos , Masculino , Nervio Mediano/fisiología , Corteza Sensoriomotora/fisiología , Relación Señal-Ruido , Adulto Joven
11.
Sci Rep ; 7: 44077, 2017 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-28333127

RESUMEN

While chemotherapy is a major mode of cancer therapeutics, its efficacy is limited by systemic toxicities and drug resistance. Recent advances in nanomedicine provide the opportunity to reduce systemic toxicities. However, drug resistance remains a major challenge in cancer treatment research. Here we developed a nanomedicine composed of a phase-change nano-droplet (PCND) and an anti-cancer antibody (9E5), proposing the concept of ultrasound cancer therapy with intracellular vaporisation. PCND is a liquid perfluorocarbon nanoparticle with a liquid-gas phase that is transformable upon exposure to ultrasound. 9E5 is a monoclonal antibody targeting epiregulin (EREG). We found that 9E5-conjugated PCNDs are selectively internalised into targeted cancer cells and kill the cells dynamically by ultrasound-induced intracellular vaporisation. In vitro experiments show that 9E5-conjugated PCND targets 97.8% of high-EREG-expressing cancer cells and kills 57% of those targeted upon exposure to ultrasound. Furthermore, direct observation of the intracellular vaporisation process revealed the significant morphological alterations of cells and the release of intracellular contents.


Asunto(s)
Anticuerpos Monoclonales/administración & dosificación , Anticarcinógenos/administración & dosificación , Neoplasias/terapia , Terapia por Ultrasonido/métodos , Animales , Anticarcinógenos/inmunología , Línea Celular Tumoral , Epirregulina/inmunología , Humanos , Técnicas In Vitro , Ratones Endogámicos BALB C , Nanoconjugados , Nanomedicina , Neoplasias/inmunología , Terapia por Ultrasonido/instrumentación
12.
Transplant Proc ; 49(1): 153-158, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28104124

RESUMEN

BACKGROUND: With the goal of in vivo cultivation of human hepatocytes that have not been sufficient in full differentiation in vitro, the advantage of neonatal thymectomy was verified on expansion of xenogeneic human hepatocyte in the micro-miniature pig (MMP). METHODS: The thymus was excised immediately after the birth of the MMPs via cesarean section. Newborns were fed by artificial feeding under specific pathogen-free conditions. The thymectomized and nonthymectomized littermates were transplanted with human hepatocytes via a portal vein with or without partial hepatectomy at the MMP adult stage. RESULTS: The growth of thymectomized MMPs and the sham operated littermates was not significantly different; the former weighed 1.98 ± 0.30 kg (average ± standard deviation, n = 4) and the latter weighed 2.28 ± 0.39 kg (n = 4) at 1 month of age, and 17.48 ± 1.92 kg and 16.75 ± 2.68 kg at 12 months of age. Blood thymosin α1 concentrations in the thymectomy group were significantly lower than in the control group (0.22 ± 0.05 ng/mL vs 0.46 ± 0.16 ng/mL; n = 4, 12 months old, P = .029). After human hepatocyte transplantation, human albumin levels were detectable on day 28 in the peripheral blood of the thymectomy plus hepatectomy group (14.3 ± 4.9 ng/mL [± range, n = 2]) but were not detectable even on day 21 in the control group. CONCLUSIONS: Neonatal thymectomy was successfully achieved in infantile MMPs born via cesarean section. These pigs were considered to be an ideal in vivo bioreactor for human hepatocytes.


Asunto(s)
Hepatocitos/citología , Modelos Animales , Timectomía , Animales , Femenino , Hepatectomía , Xenoinjertos , Humanos , Porcinos , Porcinos Enanos
13.
ESMO Open ; 1(2): e000037, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27843593

RESUMEN

Diagnosis and treatment of bone metastasis requires various types of measures, specialists and caregivers. To provide better diagnosis and treatment, a multidisciplinary team approach is required. The members of this multidisciplinary team include doctors of primary cancers, radiologists, pathologists, orthopaedists, radiotherapists, clinical oncologists, palliative caregivers, rehabilitation doctors, dentists, nurses, pharmacists, physical therapists, occupational therapists, medical social workers, etc. Medical evidence was extracted from published articles describing meta-analyses or randomised controlled trials concerning patients with bone metastases mainly from 2003 to 2013, and a guideline was developed according to the Medical Information Network Distribution Service Handbook for Clinical Practice Guideline Development 2014. Multidisciplinary team meetings are helpful in diagnosis and treatment. Clinical benefits such as physical or psychological palliation obtained using the multidisciplinary team approaches are apparent. We established a guideline describing each specialty field, to improve understanding of the different fields among the specialists, who can further provide appropriate treatment, and to improve patients' outcomes.

14.
Neuroimage ; 143: 175-195, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27561712

RESUMEN

Electric Source Imaging (ESI) and Magnetic Source Imaging (MSI) of EEG and MEG signals are widely used to determine the origin of interictal epileptic discharges during the pre-surgical evaluation of patients with epilepsy. Epileptic discharges are detectable on EEG/MEG scalp recordings only when associated with a spatially extended cortical generator of several square centimeters, therefore it is essential to assess the ability of source localization methods to recover such spatial extent. In this study we evaluated two source localization methods that have been developed for localizing spatially extended sources using EEG/MEG data: coherent Maximum Entropy on the Mean (cMEM) and 4th order Extended Source Multiple Signal Classification (4-ExSo-MUSIC). In order to propose a fair comparison of the performances of the two methods in MEG versus EEG, this study considered realistic simulations of simultaneous EEG/MEG acquisitions taking into account an equivalent number of channels in EEG (257 electrodes) and MEG (275 sensors), involving a biophysical computational neural mass model of neuronal discharges and realistically shaped head models. cMEM and 4-ExSo-MUSIC were evaluated for their sensitivity to localize complex patterns of epileptic discharges which includes (a) different locations and spatial extents of multiple synchronous sources, and (b) propagation patterns exhibited by epileptic discharges. Performance of the source localization methods was assessed using a detection accuracy index (Area Under receiver operating characteristic Curve, AUC) and a Spatial Dispersion (SD) metric. Finally, we also presented two examples illustrating the performance of cMEM and 4-ExSo-MUSIC on clinical data recorded using high resolution EEG and MEG. When simulating single sources at different locations, both 4-ExSo-MUSIC and cMEM exhibited excellent performance (median AUC significantly larger than 0.8 for EEG and MEG), whereas, only for EEG, 4-ExSo-MUSIC showed significantly larger AUC values than cMEM. On the other hand, cMEM showed significantly lower SD values than 4-ExSo-MUSIC for both EEG and MEG. When assessing the impact of the source spatial extent, both methods provided consistent and reliable detection accuracy for a wide range of source spatial extents (source sizes ranging from 3 to 20cm2 for MEG and 3 to 30cm2 for EEG). For both EEG and MEG, 4-ExSo-MUSIC localized single source of large signal-to-noise ratio better than cMEM. In the presence of two synchronous sources, cMEM was able to distinguish well the two sources (their location and spatial extent), while 4-ExSo-MUSIC only retrieved one of them. cMEM was able to detect the spatio-temporal propagation patterns of two synchronous activities while 4-ExSo-MUSIC favored the strongest source activity. Overall, in the context of localizing sources of epileptic discharges from EEG and MEG data, 4-ExSo-MUSIC and cMEM were found accurately sensitive to the location and spatial extent of the sources, with some complementarities. Therefore, they are both eligible for application on clinical data.


Asunto(s)
Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/fisiopatología , Electroencefalografía/métodos , Epilepsia/diagnóstico , Magnetoencefalografía/métodos , Electroencefalografía/normas , Humanos , Magnetoencefalografía/normas
15.
Osteoarthritis Cartilage ; 24(6): 1061-70, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26880531

RESUMEN

OBJECTIVE: We investigated the effects of single or repetitive intra-articular injections of synovial mesenchymal stem cells (MSCs) on a rat osteoarthritis (OA) model, and elucidated the behaviors and underlying mechanisms of the stem cells after the injection. DESIGN: One week after the transection of the anterior cruciate ligament (ACL) of wild type Lewis rats, one million synovial MSCs were injected into the knee joint every week. Cartilage degeneration was evaluated with safranin-o staining after the first injection. To analyze cell kinetics or MSC properties, luciferase, LacZ, and GFP expressing synovial MSCs were used. To confirm the role of MSCs, species-specific microarray and PCR analyses were performed using human synovial MSCs. RESULTS: Histological analysis for femoral and tibial cartilage showed that a single injection was ineffective but weekly injections had significant chondroprotective effects for 12 weeks. Histological and flow-cytometric analyses of LacZ and GFP expressing synovial MSCs revealed that injected MSCs migrated mainly into the synovium and most of them retained their undifferentiated MSC properties though the migrated cells rapidly decreased. In vivo imaging analysis revealed that MSCs maintained in knees while weekly injection. Species-specific microarray and PCR analyses showed that the human mRNAs on day 1 for 21 genes increased over 50-fold, and increased the expressions of PRG-4, BMP-2, and BMP-6 genes encoding chondroprotective proteins, and TSG-6 encoding an anti-inflammatory one. CONCLUSION: Not single but periodic injections of synovial MSCs maintained viable cells without losing their MSC properties in knees and inhibited osteoarthritis (OA) progression by secretion of trophic factors.


Asunto(s)
Células Madre Mesenquimatosas , Osteoartritis , Animales , Humanos , Inyecciones Intraarticulares , Trasplante de Células Madre Mesenquimatosas , Ratas , Ratas Endogámicas Lew , Membrana Sinovial
16.
Anim Genet ; 46(3): 337-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25917305

RESUMEN

This study was a first analysis of paternal genetic diversity for extensive Asian domestic goats using SRY gene sequences. Sequencing comparison of the SRY 3'-untranslated region among 210 Asian goats revealed four haplotypes (Y1A, Y1B, Y2A and Y2B) derived from four variable sites including a novel substitution detected in this study. In Asian goats, the predominant haplotype was Y1A (62%) and second most common was Y2B (30%). Interestingly, the Y2B was a unique East Asian Y chromosomal variant, which differentiates eastern and western Eurasian goats. The SRY geographic distribution in Myanmar and Cambodia indicated predominant the haplotype Y1A in plains areas and a high frequency of Y2B in mountain areas. The results suggest recent genetic infiltration of modern breeds into South-East Asian goats and an ancestral SRY Y2B haplotype in Asian native goats.


Asunto(s)
Evolución Molecular , Genes sry , Variación Genética , Cabras/genética , Animales , Cambodia , ADN Mitocondrial/genética , Asia Oriental , Haplotipos , Masculino , Mianmar , Filogeografía , Análisis de Secuencia de ADN , Cromosoma Y
17.
Transplant Proc ; 47(2): 419-26, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25769584

RESUMEN

BACKGROUND: A merit of subnormothermic perfusion has been reported to preserve grafts from ischemic injury in animal models. The split liver technique is commonly performed to solve the shortage of liver grafts. However, there has been no study showing the effect of a split liver graft on subnormothermic perfusion. We herein investigated the split liver protocol using a subnormothermic oxygenated circuit system (SOCS). METHODS: Auxiliary liver transplantation was performed in a porcine marginal donor model by using a SOCS. In the SOCS group, the portal vein and hepatic artery of the graft were cannulated, and the graft was perfused by SOCS. In the cold storage (CS) group, the graft was placed in cold preservation solution. In the preservation phase, the graft was split. RESULTS: There were no significant differences in the biochemical markers between the SOCS and CS groups. In terms of the histology, the sinusoidal spaces were widened in the CS group 12 hours after implantation. CONCLUSION: We have demonstrated a possibility to use SOCS with the split liver protocol by using a porcine model. This split liver protocol using SOCS will extend the split liver criteria and rescue more patients from hepatic failure, including pediatric patients.


Asunto(s)
Hepatectomía/métodos , Hipotermia Inducida/métodos , Trasplante de Hígado/métodos , Preservación de Órganos/métodos , Perfusión/métodos , Recolección de Tejidos y Órganos/métodos , Animales , Femenino , Masculino , Distribución Aleatoria , Porcinos
18.
Comput Med Imaging Graph ; 40: 205-16, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25263644

RESUMEN

This work introduces a self-contained framework for endoscopic camera tracking by combining 3D ultrasonography with endoscopy. The approach can be readily incorporated into surgical workflows without installing external tracking devices. By fusing the ultrasound-constructed scene geometry with endoscopic vision, this integrated approach addresses issues related to initialization, scale ambiguity, and interest point inadequacy that may be faced by conventional vision-based approaches when applied to fetoscopic procedures. Vision-based pose estimations were demonstrated by phantom and ex vivo monkey placenta imaging. The potential contribution of this method may extend beyond fetoscopic procedures to include general augmented reality applications in minimally invasive procedures.


Asunto(s)
Fetoscopía/métodos , Imagenología Tridimensional/métodos , Técnica de Sustracción , Cirugía Asistida por Computador/métodos , Ultrasonografía Prenatal/métodos , Interfaz Usuario-Computador , Algoritmos , Inteligencia Artificial , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Transplant Rev (Orlando) ; 28(4): 155-62, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24975516

RESUMEN

The rat is the most widely used animal species in surgical research and offers distinct advantages over the mouse in transplantation models due to its size and close genetic similarity to humans. Sequencing of the rat genome and successful application of transgenic technologies which had only been available for mice have since led to a resurgence of the use of rat models. Transplantation provides the possibility to deliver transgenes through a variety of routes which can potentially offer treatment modalities for post-transplant dysfunction and rejection. Moreover, the use of genetically encoded fluorescent light probes has enabled in vivo visualization of organs and tissue in living animals. In recent years, generation of gene knockout rats via the zinc-finger nuclease (ZFN) and transcription activator-like effector nuclease (TALEN) technologies has offered alternatives to the sophisticated embryonic stem cell based gene-targeting. In this review, we aim to provide an overview of transplantation studies involving transgenic techniques using rat models and recent advances in methods to modify the rat genome. Through novel gene modification techniques, precise, complete and conditional knockout and knockin rat models have become available which can provide promising new treatment options and opportunities for studying human transplant-related pathophysiology.


Asunto(s)
Marcación de Gen , Trasplante de Órganos , Ratas Transgénicas , Animales , Técnicas de Inactivación de Genes , Marcación de Gen/métodos , Técnicas de Transferencia de Gen , Trasplante de Riñón , Ratas , Daño por Reperfusión/genética , Investigación , Activación Transcripcional
20.
Osteoarthritis Cartilage ; 22(7): 941-50, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24795274

RESUMEN

OBJECTIVE: A new strategy is required in order to regenerate a meniscus for extensive defects. Synovial mesenchymal stem cells (MSCs) are an attractive cell source for meniscus regeneration due to their high proliferation and chondrogenic potential. We examined the effect of repetitive intraarticular injections of synovial MSCs on meniscus regeneration in a massive meniscal defect of pigs. We followed up the efficacy using MRI evaluation in addition to macroscopic and histological observations. DESIGN: Two weeks before the injection of synovial MSCs, the anterior half of the medial menisci was resected in both knees of pigs. Fifty million allogeneic synovial MSCs were injected into the right knee at 0, 2, and 4 weeks and followed up by sequential MRI. The regenerated meniscus, adjacent articular cartilage, and subchondral bone were evaluated by MRI at 2, 4, 8, 12 and 16 weeks. They were also evaluated macroscopically and histologically at 16 weeks (n = 7). RESULTS: The resected meniscus regenerated significantly better in the MSC group than in the control group based on histological and MRI analyses. Macroscopically, the meniscal defect already appeared to be filled with synovial tissue at 2 weeks. Articular cartilage and subchondral bone at the medial femoral condyle were also significantly more preserved in the MSC group based on MRI, macroscopic, and histological analyses. CONCLUSIONS: Intraarticular injections of allogeneic synovial MSCs appeared to promote meniscus regeneration and provide protection at the medial femoral articular cartilage in a porcine massive meniscal defect model.


Asunto(s)
Traumatismos de la Rodilla/terapia , Meniscos Tibiales/fisiología , Trasplante de Células Madre Mesenquimatosas/métodos , Células Madre Mesenquimatosas/citología , Regeneración/fisiología , Aloinjertos , Animales , Cartílago Articular/patología , Inyecciones Intraarticulares , Traumatismos de la Rodilla/patología , Imagen por Resonancia Magnética , Meniscos Tibiales/cirugía , Modelos Animales , Porcinos , Membrana Sinovial/patología , Lesiones de Menisco Tibial , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...