Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Injury ; 53(3): 878-884, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34782117

RESUMEN

INTRODUCTION: Intramedullary nails are frequently used for treatment of unstable distal tibia fractures. However, insufficient fixation of the distal fragment could result in delayed healing, malunion or nonunion. Recently, a novel concept for angular stable nailing was developed that maintains the principle of relative stability and introduces improvements expected to reduce nail toggling, screw migration and secondary loss of reduction. The aim of this study was to investigate the biomechanical competence of the novel angular stable intramedullary nail concept for treatment of unstable distal tibia fractures, compared to a conventional nail locking in a human cadaveric model under dynamic loading. MATERIALS AND METHODS: Ten pairs of fresh-frozen human cadaveric tibiae with a simulated AO/OTA 42-A3.1 fracture were assigned to 2 groups for reamed intramedullary nailing using either a conventional (non-angular stable) Expert Tibia Nail (ETN) with 3 distal screws or the novel Tibia Nail Advanced (TNA) system with 2 distal angular stable locking low-profile retaining screws. The specimens were biomechanically tested under conditions including initial quasi-static loading, followed by progressively increasing combined cyclic axial and torsional loading in internal rotation until failure of the bone-implant construct. Both tests were monitored by means of motion tracking. RESULTS: Initial nail toggling of the distal tibia fragment in varus and flexion under axial loading was lower for TNA compared to ETN, being significant in flexion, P = 0.91 and P = 0.03. After 5000 cycles, interfragmentary movements in terms of varus, flexion, internal rotation, axial displacement, and shear displacement at the fracture site were all lower for TNA compared to ETN, with flexion and shear displacement being significant, P = 0.14, P = 0.04, P = 0.25, P = 0.11 and P = 0.04, respectively. Cycles to failure until both interfragmentary 5° varus and 5° flexion were significantly higher for TNA compared to ETN, P = 0.04. CONCLUSION: From a biomechanical perspective, the novel angular stable intramedullary nail concept provides increased construct stability and maintains it over time while reducing the number of required locking screws without impeding the flexibility of the nail itself and resists better towards loss of reduction under dynamic loading, compared to conventional locking in intramedullary nailed unstable distal tibia fractures.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de la Tibia , Fenómenos Biomecánicos , Clavos Ortopédicos , Placas Óseas , Humanos , Tibia , Fracturas de la Tibia/cirugía
2.
J Phys Condens Matter ; 22(5): 053201, 2010 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-21386337

RESUMEN

We present details and results for a superconducting quantum bit (qubit) design in which a tunable flux qubit is coupled strongly to a transmission line. Quantum information storage in the transmission line is demonstrated with a dephasing time of T(2)∼ 2.5 µs. However, energy lifetimes of the qubit are found to be short (∼ 10 ns) and not consistent with predictions. Several design and material changes do not affect qubit coherence times. In order to determine the cause of these short coherence times, we fabricated standard flux qubits based on a design which was previously successfully used by others. Initial results show significantly improved coherence times, possibly implicating losses associated with the large size of our qubit.

3.
Phys Rev Lett ; 98(26): 267003, 2007 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-17678120

RESUMEN

We propose a model for 1/f flux noise in superconducting devices (f is frequency). The noise is generated by the magnetic moments of electrons in defect states which they occupy for a wide distribution of times before escaping. A trapped electron occupies one of the two Kramers-degenerate ground states, between which the transition rate is negligible at low temperature. As a result, the magnetic moment orientation is locked. Simulations of the noise produced by randomly oriented defects with a density of 5x10(17) m(-2) yield 1/f noise magnitudes in good agreement with experiments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA