Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Materials (Basel) ; 17(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38894016

RESUMEN

We investigated micro-threaded stem taper surface and its impact on premature failures, aseptic loosening, and infection in cementless hip endoprostheses. Our study focused on the fretting, and crevice corrosion of micro-threaded tapers, as well as the characterization of the microstructure and surface properties of two new and three retrieved Zweymüller stem tapers. The retrieved samples were selected and examined based on the head-stem taper interface being the sole source of modularity with a metallic component, specifically between the Ti alloy taper stem and the ceramic head. To determine the surface chemistry and microstructures of both new and retrieved hip endoprostheses stem taper titanium alloy, scanning -electron microscopy (SEM) was employed for morphological and microstructural analyses. Energy dispersive spectroscopy (EDS) was utilized for characterizing chemical element distribution, and electron backscattered diffraction (EBSD) was used for phase analysis. The roughness of the micro-threated stem tapers from different manufacturers was investigated using an optical profilometer, with standard roughness parameters Ra (average surface roughness) and Rz (mean peak to valley height of the roughness profile) being measured. Electrochemical studies revealed no fretting corrosion in retrieved stem tapers with ceramic heads. Consequently, three retrieved tapers and two new ones for comparison underwent potentiodynamic measurements in Hank's solution to determine the corrosion rate of new and retrieved stem taper surfaces. The results showed a low corrosion rate for both new and prematurely failed retrieved samples due to aseptic loosening. However, the corrosion rate was higher in infected and low-grade infected tapers. In conclusion, our study suggests that using ceramic heads reduces taper corrosion and subsequently decreases the incidence of premature failures in total hip arthroplasty.

2.
Materials (Basel) ; 16(21)2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37959464

RESUMEN

For the improvement of surface roughness, titanium joint arthroplasty (TJA) components are grit-blasted with Al2O3 (corundum) particles during manufacturing. There is an acute concern, particularly with uncemented implants, about polymeric, metallic, and corundum debris generation and accumulation in TJA, and its association with osteolysis and implant loosening. The surface morphology, chemistry, phase analysis, and surface chemistry of retrieved and new Al2O3 grit-blasted titanium alloy were determined with scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDS), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and confocal laser fluorescence microscopy, respectively. Peri-prosthetic soft tissue was studied with histopathology. Blasted retrieved and new stems were exposed to human mesenchymal stromal stem cells (BMSCs) for 7 days to test biocompatibility and cytotoxicity. We found metallic particles in the peri-prosthetic soft tissue. Ti6Al7Nb with the residual Al2O3 particles exhibited a low cytotoxic effect while polished titanium and ceramic disks exhibited no cytotoxic effect. None of the tested materials caused cell death or even a zone of inhibition. Our results indicate a possible biological effect of the blasting debris; however, we found no significant toxicity with these materials. Further studies on the optimal size and properties of the blasting particles are indicated for minimizing their adverse biological effects.

3.
Materials (Basel) ; 16(9)2023 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-37176169

RESUMEN

We studied inflammatory and oxidative stress-related parameters and cytotoxic response of human umbilical vein endothelial cells (HUVEC) to a 24 h treatment with milled particles simulating debris involved in sandblasting of orthopedic implants (OI). We used different abrasives (corundum-(Al2O3), used corundum retrieved from removed OI (u. Al2O3), and zirconia/silica composite (ZrO2/SiO2)). Morphological changes were observed by scanning electron microscopy (SEM). Concentration of Interleukins IL-6 and IL-1ß and Tumor Necrosis Factor α (TNF)-α was assessed by enzyme-linked immunosorbent assay (ELISA). Activity of Cholinesterase (ChE) and Glutathione S-transferase (GST) was measured by spectrophotometry. Reactive oxygen species (ROS), lipid droplets (LD) and apoptosis were measured by flow cytometry (FCM). Detachment of the cells from glass and budding of the cell membrane did not differ in the treated and untreated control cells. Increased concentration of IL-1ß and of IL-6 was found after treatment with all tested particle types, indicating inflammatory response of the treated cells. Increased ChE activity was found after treatment with u. Al2O3 and ZrO2/SiO2. Increased GST activity was found after treatment with ZrO2/SiO2. Increased LD quantity but not ROS quantity was found after treatment with u. Al2O3. No cytotoxicity was detected after treatment with u. Al2O3. The tested materials in concentrations added to in vitro cell lines were found non-toxic but bioactive and therefore prone to induce a response of the human body to OI.

4.
Int J Mol Sci ; 24(4)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36834843

RESUMEN

The preparation of autologous platelet and extracellular vesicle-rich plasma (PVRP) has been explored in many medical fields with the aim to benefit from its healing potential. In parallel, efforts are being invested to understand the function and dynamics of PVRP that is complex in its composition and interactions. Some clinical evidence reveals beneficial effects of PVRP, while some report that there were no effects. To optimize the preparation methods, functions and mechanisms of PVRP, its constituents should be better understood. With the intention to promote further studies of autologous therapeutic PVRP, we performed a review on some topics regarding PVRP composition, harvesting, assessment and preservation, and also on clinical experience following PVRP application in humans and animals. Besides the acknowledged actions of platelets, leukocytes and different molecules, we focus on extracellular vesicles that were found abundant in PVRP.


Asunto(s)
Plasma Rico en Plaquetas , Humanos , Animales , Plaquetas , Cicatrización de Heridas , Leucocitos
5.
Acta Bioeng Biomech ; 23(1): 25-34, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34846027

RESUMEN

PURPOSE: Unfavourable distribution of contact stress over the load bearing area is considered a risk factor for early coxarthritis and it is of interest to outline respective biomechanical parameters for its prediction. The purpose of the work was to develop a transparent mathematical model which can be used to assess contact stress in the hip from imaged structures of pelvis and proximal femora, in large population studies and in clinical practice. METHODS: We upgraded a previously validated three-dimensional mathematical model of the human hip in the one-legged stance HIPSTRESS by introducing parameters independent from the size of the structures in the images. We validated a new parameter - dimensionless peak stress normalized by the body weight and by the radius of the femoral head (pmaxr²/WB) on the population of 172 hips that were in the childhood subjected to the Perthes disease and exhibited increased proportion of dysplastic hips. RESULTS: The dimensionless parameter pmaxr²/WB exhibited smaller number of indecisive cases of hip dysplasia predicted by the model than the previously used parameter pmax/WB (6% vs. 81%, respectively). A threshold for an increased risk of early coxarthritis development by the HIPSTRESS parameter H = pmaxr²/WB was found to be 2. CONCLUSIONS: We proposed a dimensionless peak stress on the load bearing area with the border value of 2 as a decisive parameter over which hips are at risk for early development of degenerative processes and presented a method for determination of biomechanical parameters with the use of nomogram.


Asunto(s)
Cabeza Femoral , Articulación de la Cadera , Fenómenos Biomecánicos , Niño , Cadera , Humanos , Estrés Mecánico
6.
Anaerobe ; 61: 102133, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31813852

RESUMEN

Cutibacterium acnes is a major etiologic agent of orthopaedic implant-associated infections (IAIs) and requires up to 14 days of incubation in an anaerobic atmosphere for growth detection. As blood culture (BC) systems are increasingly being used to monitor the growth of IAI specimens, we compared different BC media for growth detection of C. acnes. Non-duplicate C. acnes isolates (n = 99) obtained from sonicate-fluid cultures of orthopaedic IAIs from Slovenia (n = 54), conventional tissue samples of monomicrobial orthopaedic IAIs from France (n = 43) and two reference strains were inoculated to anaerobic BC bottles of two major BC systems and 3 conventional culture media types (thioglycolate broth, Schaedler and chocolate agar). Growth and time-to-detection (TTD) were recorded. Only Lytic (BACTEC) and SN (BacT/ALERT) bottles consistently detected growth of C. acnes within 14 days with 94% (n = 93) and 92% (n = 91) detection rates, respectively (p = 0.79). Lytic was superior to Plus BACTEC medium (p < 0.001), while SN was superior to all other BacT/ALERT media (p < 0.001). Mean TTD was 128 ± 43 h (61-336 h) for Lytic and 158 ± 65 h (77-336 h) for SN medium. Among the conventional media, 99% (n = 98) of the isolates grew on Schaedler agar, 96% (n = 95) in thioglycolate broth and 74% (n = 73) on chocolate agar. Inconsistent growth of C. acnes in different BC media can critically influence the detection of this major IAI pathogen. Only Lytic (BACTEC) and SN (BacT/ALERT) BC media types were consistently able to detect C. acnes within 14 days of incubation. However, visible growth was observed faster in thioglycolate broth and Schaedler agar media.


Asunto(s)
Infecciones por Bacterias Grampositivas/diagnóstico , Infecciones por Bacterias Grampositivas/microbiología , Procedimientos Ortopédicos/efectos adversos , Propionibacterium acnes , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Técnicas de Tipificación Bacteriana , Cultivo de Sangre , Humanos , Propionibacterium acnes/clasificación , Propionibacterium acnes/aislamiento & purificación
7.
Comput Methods Biomech Biomed Engin ; 22(14): 1107-1115, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31429314

RESUMEN

The biomechanical parameters of the hip joint articular surface were analysed in 141 adult hips after Legg-Calve Perthes Disease, and 114 contralateral unaffected hips (controls), by using HIPSTRESS mathematical models. Geometrical parameters, assessed from anteroposterior and axial radiograms, were used as input to models for resultant hip force and contact hip stress. Results confirm previous indications that head enlargement after the Legg-Calve-Perthes Disease compensates the values of hip stress. Furthermore, it was found that an increased risk for coxarthritis development after the disease is secondary to concomitant hip dysplasia, with considerable and statistically significantly lower centre-edge angle and unfavourable distribution of stress.


Asunto(s)
Artritis/etiología , Luxación de la Cadera/complicaciones , Cadera/patología , Enfermedad de Legg-Calve-Perthes/complicaciones , Artritis/fisiopatología , Fenómenos Biomecánicos , Cadera/diagnóstico por imagen , Cadera/fisiopatología , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/fisiopatología , Humanos , Enfermedad de Legg-Calve-Perthes/diagnóstico por imagen , Enfermedad de Legg-Calve-Perthes/fisiopatología
8.
J Orthop Res ; 32(1): 8-16, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24038236

RESUMEN

To study the effect of hip and pelvis geometry on development of the hip after Perthes disease, we determined the resultant hip force and contact hip stress distribution in a population of 135 adult hips of patients who had been treated for Perthes disease in childhood. Contra-lateral hips with no record of disease were taken as the control population. Biomechanical parameters were determined by mathematical models for resultant hip force in one-legged stance and for contact hip stress, which use as an input the geometrical parameters assessed from anteroposterior radiographs. The mathematical model for stress was upgraded to account for the deviation of the femoral head shape from spherical. No differences were found in resultant hip force and in peak contact hip stress between the hips that were in childhood subject to Perthes disease and the control population, but a considerable (148%) and significant (p < 0.001) difference was found in the contact hip stress gradient index, expressing an unfavorable, steep decrease of contact stress at the lateral acetabular rim. This finding indicates an increased risk of early coxarthritis in hips subject to Perthes disease.


Asunto(s)
Necrosis de la Cabeza Femoral/fisiopatología , Articulación de la Cadera/fisiopatología , Enfermedad de Legg-Calve-Perthes/fisiopatología , Modelos Biológicos , Acetábulo/diagnóstico por imagen , Acetábulo/fisiopatología , Adolescente , Adulto , Fenómenos Biomecánicos/fisiología , Niño , Preescolar , Femenino , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/fisiopatología , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Enfermedad de Legg-Calve-Perthes/diagnóstico por imagen , Masculino , Radiografía , Estrés Mecánico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...