Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Cardiothorac Vasc Anesth ; 37(3): 432-436, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36599778

RESUMEN

OBJECTIVES: To examine the efficacy of continuous unilateral erector spinae plane (ESP) blocks in minimally invasive cardiac surgery patients. DESIGN: A retrospective nonrandomized study. SETTING: At a single-center, tertiary academic institution. PARTICIPANTS: The study comprised 129 adult patients undergoing minimally invasive cardiac surgery with cardiopulmonary bypass or extracorporeal membrane oxygenation. INTERVENTIONS: Patient data were retrospectively collected and compared. Group 1 patients received ultrasound-guided ESP blocks, and group 2 patients underwent conventional intraoperative management without ESP blocks. After intubation in the group 1 cohort, 20-to- 25 mL of 0.25% ropivacaine were deposited beneath the erector spinae plane, along with catheter placement for continuous postoperative infusion. MEASUREMENTS AND MAIN RESULTS: Patient characteristics (ie, age, sex, and comorbidities) were well-matched between both cohorts. The total 48-hour opioid consumption, as measured in morphine equivalents (mg), was significantly decreased in patients receiving erector spinae plane blocks compared to patients receiving conventional therapy (30.24 mg ± 23.8 v 47.82 mg ± 53.6, p = 0.04). The length of stay in the intensive care unit (ICU) also was reduced in the treatment group in comparison to the control group (1.99 days ± 1.7 v 2.65 days ± 2.4, p = 0.03). Lastly, patients receiving the blocks benefitted from a decrease in overall hospital length of stay when compared to the control group (5.93 days ± 2.4 v 7.35 days ± 5.8, p = 0.04). CONCLUSION: Erector spinae plane catheter use may safely improve postoperative measures, including decreased opioid consumption and improved pain relief, as well as reductions in ICU and hospital lengths of stay in patients undergoing minimally invasive cardiac surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Bloqueo Nervioso , Adulto , Humanos , Analgésicos Opioides , Estudios Retrospectivos , Dolor Postoperatorio/prevención & control , Ultrasonografía Intervencional
2.
J Thorac Cardiovasc Surg ; 161(1): 80-88, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31983525

RESUMEN

OBJECTIVE: Mitral annular calcification is underdiagnosed in patients with mitral regurgitation. After excision, it may require reconstruction of the atrioventricular groove and decreases the probability of valve repair. We reviewed the safety and efficacy of totally endoscopic robotic mitral valve repair in the presence of mitral annular calcification, with an emphasis on pathology and repair techniques. METHODS: Between May 2011 and August 2017, the same 2-surgeon team attempted totally endoscopic robotic mitral valve repair in 64 mitral annular calcification cases, accounting for 12.8% of our experience. Mitral annular calcification associated with a calcified posterior leaflet was not considered for totally endoscopic robotic mitral valve repair. When possible, the mitral annular calcification was excised en bloc using electrocautery, the posterior leaflet separated from the mitral annular calcification and spared, the atrioventricular groove was reconstructed, the posterior leaflet was reattached to the neoannulus, and the repair was completed with annuloplasty. RESULTS: The median age of patients was 65 years, with 21 (32.8%) aged less than 60 years, and 34 (53.1%) were women. The etiology was Barlow's disease in 54 patients (84%). Repair was converted to replacement in 2 patients (3.1%). Cryoablation was performed in 8 patients (12.5%), hybrid percutaneous coronary intervention was performed in 5 patients (7.8%), and tricuspid annuloplasty was performed in 2 patients (3.1%). Median aortic occlusion was 122 minutes, excluding cases with concomitant tricuspid repair. Thirty-three patients (52%) were extubated in the operating room. The median length of stay was 4 days. Residual mitral regurgitation on discharge transthoracic echocardiogram was none to mild in all patients. None of the patients had a perioperative stroke or needed a pacemaker. Thirty-day mortality was 2 (3.1%). CONCLUSIONS: Mitral annular calcification is present in a significant percentage of patients with mitral regurgitation, especially in Barlow's disease, including younger patients. By using a variety of repair techniques, totally endoscopic robotic mitral valve repair can be performed safely and effectively in most mitral annular calcification cases with a noncalcified posterior leaflet.

3.
J Thorac Cardiovasc Surg ; 158(1): 39-45.e1, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30718051

RESUMEN

OBJECTIVE: Advances in transcatheter aortic valve replacement have led to the consideration of tissue aortic valve replacement in younger patients. Part of this enthusiasm is the presumption that younger patients would have more flexibility in future treatment options, such as a primary surgical aortic valve replacement followed later by transcatheter aortic valve replacement(s) (valve-in-valve), vice versa, or other permutations. We created a microsimulation model using published longevity of tissue valves to predict the outcomes of patients after primary tissue surgical aortic valve replacement. METHODS: The model calculated survival by incorporating annual mortality (Social Security Administration) and mortality from re-replacements (Society of Thoracic Surgeons) in patients with surgical aortic valve replacement. Freedom from reoperation for structural valve degeneration incorporated best published data to determine the annual risk of re-replacement for structural valve degeneration based on implant duration and stratified by patient age. A constant rate of re-replacement for nonstructural valve degeneration indications was also incorporated. Each simulation was performed for 50,000 individuals. Kaplan-Meier curves were generated to represent survival. All simulations were run within the MATLAB environment (The MathWorks, Inc, Natick, Mass). RESULTS: Earlier decades of life at primary surgical aortic valve replacement were associated with higher incidences of re-replacements and especially multiple re-replacements. For those patients receiving a primary tissue surgical aortic valve replacement at age 50 years, 57.2% will require a second valve, 18.0% will require a third valve, and 1.6% will require a fourth valve with average operative mortalities of 2.9%, 4.8%, and 7.3%, respectively. A 50-year-old patient at primary surgical aortic valve replacement has a 13.1% chance of re-replacement before turning 60 years of age. CONCLUSIONS: Microsimulation incorporates changing hazards to estimate the risk of aortic valve re-replacement in patients undergoing tissue surgical aortic valve replacement and may be a starting point for patient education and health care economic planning.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Reoperación , Factores de Edad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Esperanza de Vida , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Reoperación/métodos , Reoperación/estadística & datos numéricos , Factores de Riesgo , Factores Sexuales , Análisis de Supervivencia , Factores de Tiempo
4.
Semin Thorac Cardiovasc Surg ; 31(1): 32-37, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30102970

RESUMEN

Medicare's Bundle Payment for Care Improvement (BPCI) Model 2 groups reimbursement for valve surgery into 90-day episodes of care, which include operative costs, inpatient stay, physician fees, postacute care, and readmissions up to 90 days postprocedure. We analyzed our BPCI patients' 90-day outcomes to understand the late financial risks and implications of the bundle payment system for valve patients. All BPCI valve patients from October 2013 (start of risk-sharing phase) to December 2015 were included. Readmissions were categorized as early (≤30 days) or late (31-90 days). Data were collected from institutional databases as well as Medicare claims. Analysis included 376 BPCI valve patients: 202 open and 174 transcatheter aortic valves (TAVR). TAVR patients were older (83.6 vs 73.8 years; P = 0.001) and had higher Society of Thoracic Surgery predicted risk (7.1% vs 2.8%; P = 0.001). Overall, 18.6% of patients (70/376) had one-or-more 90-day readmission, and total claim was on average 51% greater for these patients. Overall readmissions were more common among TAVR patients (22.4% (39/174) vs 15.3% (31/202), P = 0.052) as was late readmission. TAVR patients had significantly higher late readmission claims, and early readmission was predictive of late readmission for TAVR patients only (P = 0.04). Bundled claims for a 90-day episode of care are significantly increased in patients with readmissions. TAVR patients represent a high-risk group for late readmission, possibly a reflection of their chronic disease processes. Being able to identify patients at highest risk for 90-day readmission and the associated claims will be valuable as we enter into risk-bearing episodes of care agreements with Medicare.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/economía , Política de Salud/economía , Enfermedades de las Válvulas Cardíacas/economía , Enfermedades de las Válvulas Cardíacas/cirugía , Costos de Hospital , Evaluación de Procesos y Resultados en Atención de Salud/economía , Paquetes de Atención al Paciente/economía , Readmisión del Paciente/economía , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/legislación & jurisprudencia , Procedimientos Quirúrgicos Cardíacos/mortalidad , Centers for Medicare and Medicaid Services, U.S./economía , Ahorro de Costo , Análisis Costo-Beneficio , Bases de Datos Factuales , Femenino , Política de Salud/legislación & jurisprudencia , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/mortalidad , Costos de Hospital/legislación & jurisprudencia , Humanos , Masculino , Medicare/economía , Evaluación de Procesos y Resultados en Atención de Salud/legislación & jurisprudencia , Readmisión del Paciente/legislación & jurisprudencia , Formulación de Políticas , Mecanismo de Reembolso/economía , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
5.
Case Rep Pediatr ; 2018: 8780121, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30009073

RESUMEN

There is increasing use of low-molecular-weight heparin (LMWH) for treatment of pediatric thromboembolic disease as it has been shown to be safe and effective. It has several advantages over unfractionated heparin, such as reduced need for monitoring, easier route of administration, decreased risk of heparin-induced thrombocytopenia, and lack of drug-drug interactions. Nevertheless, LMWH still poses a bleeding risk as with any anticoagulant therapy. We present the case of a 4-year-old boy who was placed on LMWH for a catheter-related deep venous thrombosis in the setting of intractable seizures and subsequently developed a small bowel obstruction secondary to a suspected intussusception. He underwent exploratory laparotomy and was found to have an intramural bowel hematoma. Prior to this bleed, the patient had been monitored daily, and his anti-Xa levels were found to be in the therapeutic range. This case highlights the need for a high index of suspicion for spontaneous bleeding even in the setting of therapeutic anti-Xa levels.

6.
Ann Thorac Surg ; 106(3): 685-690, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29705366

RESUMEN

BACKGROUND: Expandable, rapid deployment aortic valves may interfere with the cardiac conduction system, which can lead to permanent pacemaker implantation (PPI). We sought to characterize PPI after rapid deployment aortic valve replacement with the Edwards Intuity valve system (Edwards Lifesciences, Irvine, CA) and investigate associated factors. METHODS: We analyzed 708 patients from 29 centers in the Multicenter Experience With Rapid Deployment Edwards Intuity Valve System for Aortic Valve Replacement (TRANSFORM) trial undergoing rapid deployment aortic valve replacement with or without coronary artery bypass graft surgery without preexisting pacemakers. Intrinsic conduction status was recorded as well as PPI incidence through 1 year. The PPI indications were categorized based on expert review of patient PPI source documents. Multivariate analysis was conducted to identify characteristics associated with PPI. RESULTS: After rapid deployment aortic valve replacement, the PPI incidence through 30 days (PPI30) was 13.6%, with 10.9% due to atrioventricular block. In the 423 of 708 patients (59.7%) without any baseline conduction abnormalities, all-cause PPI30 was 8%, 5% for atrioventricular block. For PPIs inserted before discharge, the median time to PPI was 5 days, with 22% placed within 48 hours. Independent predictors of PPI30 were baseline right bundle branch block (odds ratio 7.35, p < 0.0001), female gender (2.62, p = 0.004), larger valve size (1.20, p = 0.016), and atrioventricular block (1.80, p = 0.062). Subset analysis revealed a greater than twofold difference in PPI30 among the largest enrolling centers. CONCLUSIONS: Patient factors associated with PPI after rapid deployment aortic valve replacement were right bundle branch block, atrioventricular block, female gender, and larger valve size. Interestingly, a strong center-level effect was associated with PPI. This effect may reflect differences in practice patterns, such as postoperative drug management or timing to PPI. These findings provide a deeper understanding of PPI after rapid deployment aortic valve replacement and help guide clinical practice and patient management.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Edad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/etiología , Estimulación Cardíaca Artificial/métodos , Estudios de Cohortes , Electrocardiografía/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Mortalidad Hospitalaria/tendencias , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Tasa de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
7.
J Card Surg ; 33(2): 64-68, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29460374

RESUMEN

BACKGROUND: We analyzed the impact and safety of del Nido Cardioplegia (DNC) in patients undergoing minimally invasive aortic valve replacement (MIAVR). METHODS: We analyzed all isolated MIAVR replacements from 5/2013-6/2015 excluding re-operative patients. The approach was a hemi-median sternotomy in all patients. Patients were divided into two cohorts, those who received 4:1 crystalloid:blood DNC solution and those in whom standard 1:4 Buckberg-based cardioplegia (WBC) was used. One-to-one propensity case matching of DNC to WBC was performed based on standard risk factors and differences between groups were analyzed using chi-square and non-parametric methods. RESULTS: MIAVR was performed in 181 patients; DNC was used in 59 and WBC in 122. Case matching resulted in 59 patients per cohort. DNC was associated with reduced re-dosing (5/59 (8.5%) versus 39/59 (61.0%), P < 0.001) and less total cardioplegia volume (1290 ± 347 mL vs 2284 ± 828 mL, P < 0.001). Antegrade cardioplegia alone was used in 89.8% (53/59) of DNC patients versus 33.9% (20/59) of WBC patients (P < 0.001). Median bypass and aortic cross-clamp times were similar. Clinical outcomes were similar with respect to post-operative hematocrit, transfusion requirements, need for inotropic/pressor support, duration of intensive care unit stay, re-intubation, length of stay, new onset atrial fibrillation, and mortality. CONCLUSIONS: Del Nido cardioplegia usage during MIAVR minimized re-dosing and the need for retrograde delivery. Patient safety was not compromised with this technique in this group of low-risk patients undergoing MIAVR.


Asunto(s)
Válvula Aórtica/cirugía , Paro Cardíaco Inducido/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Estudios de Cohortes , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Factores de Riesgo , Seguridad , Esternotomía/métodos , Resultado del Tratamiento
8.
Innovations (Phila) ; 12(3): 197-200, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28549029

RESUMEN

OBJECTIVE: Although the benefits of minimally invasive valvular surgery are well established, the applicability of extending these techniques to reoperative aortic valve surgery is unknown. We evaluated our experience with a minimally invasive approach to this patient population. METHODS: From January 2010 to September 2015, 21 patients underwent reoperative isolated aortic valve replacement via a minimally invasive approach by a single surgeon. All patients had preoperative evaluation with computerized tomography and coronary catheterization. Surgical approaches were right anterior thoracotomy (6/21) or upper hemisternotomy (15/21). Central aortic cannulation was preferred with femoral artery cannulation used in four patients (19%). In patients with left internal mammary artery (LIMA) grafts, no attempt to dissect or occlude the graft was made. Cold blood cardioplegia was administered antegrade (12/21) or retrograde (9/21); systemic cooling with a mean low temperature of 27.5 °C was employed. RESULTS: Mean age was 75.1 years with a range from 33 to 92 years, and 67% (14/21) were male. All procedures were completed with a minimally invasive approach. Mean ± SD cross-clamp time was 51.5 ± 9.2 minutes. Fourteen patients had patent LIMA grafts. No aortic, LIMA, or cardiac injuries occurred. There were no hospital deaths nor occurrences of perioperative myocardial infarction, stroke, wound infection, renal failure, or endocarditis/sepsis. One patient required a reoperation for bleeding. Sixty-two percent of patients were discharged to home; mean ± SD length of stay was 6 ± 3 days. CONCLUSIONS: With appropriate preoperative evaluation and careful surgical planning, a minimally invasive approach to reoperative aortic valve surgery can be performed in a safe and effective manner.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Procedimientos Quirúrgicos Mínimamente Invasivos , Reoperación , Anciano , Anciano de 80 o más Años , Puente Cardiopulmonar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
9.
J Thorac Cardiovasc Surg ; 154(1): 190-198, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28412109

RESUMEN

BACKGROUND: Bundled Payments for Care Improvement (BPCI) initiatives were developed by Medicare in an effort to reduce expenditures while preserving quality of care. Payment model 2 reimburses based on a target price for 90-day episode of care postprocedure. The challenge for valve patients is the historically high (>35%) 90-day readmission rate. We analyzed our institutional cardiac surgical service line adaptation to this initiative. METHODS: On May 1, 2015, we instituted a readmission reduction initiative (RRI) that included presurgical risk stratification, comprehensive predischarge planning, and standardized postdischarge management led by cardiac nurse practitioners (CNPs) who attempt to guide any postdischarge encounters (PDEs). A prospective database also was developed, accruing data on all cardiac surgery patients discharged after RRI initiation. We analyzed detailed PDEs for all valve patients with complete 30-day follow-up through November 2015. RESULTS: Patients included 219 surgical patients and 126 transcatheter patients. Sixty-four patients had 79 PDEs. Of these 79 PDEs, 46 (58.2%) were guided by CNPs. PDEs were due to fluid overload/effusion (21, 27%), arrhythmia (17, 22%), bleeding/thromboembolic events (13, 16%), and falls/somatic complaints (12, 15%). Thirty-day readmission rate was 10.1% (35/345). Patients with transcatheter aortic valve replacement had a higher rate of readmission than surgical patients (15.0% vs 6.9%), but were older with more comorbidities. The median readmission length of stay was 2.0 days (interquartile range 1.0-5.0 days). Compared with 2014, the 30-day readmission rate for BPCI decreased from 18% (44/248) to 11% (20/175), P = .05. CONCLUSIONS: Our reengineering of pre/postdischarge management of BPCI valve patients under tight CNP control has significantly reduced costly 30-day readmissions in this high-risk population.


Asunto(s)
Cateterismo Cardíaco/economía , Enfermedades de las Válvulas Cardíacas/economía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/economía , Válvulas Cardíacas/cirugía , Costos de Hospital , Evaluación de Procesos y Resultados en Atención de Salud/economía , Paquetes de Atención al Paciente/economía , Alta del Paciente/economía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Ahorro de Costo , Bases de Datos Factuales , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Medicare , Persona de Mediana Edad , Readmisión del Paciente/economía , Estudios Retrospectivos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/economía , Resultado del Tratamiento , Estados Unidos
11.
Heart Lung ; 46(2): 74-78, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28057337

RESUMEN

OBJECTIVES: To determine the relationship between caregiver status and outcomes after durable left ventricular assist device (LVAD) implantation. BACKGROUND: The absence of a caregiver is a relative contraindication to durable LVAD support. METHODS: Forty-three patients that underwent primary LVAD implantation were divided into three groups: those with caregivers that retained their roles for the duration of LVAD support (CG group), those with caregivers that resigned their roles (CG-QUIT group), and those implanted without an assigned caregiver (No-CG group). Group-specific characteristics and post-implant outcomes were compared. RESULTS: In the CG-QUIT group, caregivers did not live in the same home (0.0% vs. 80.6% of CG group) and none were spouses (0.0% vs. 64.5% for CG group). Thirty-day readmission rate was highest in the CG-QUIT group (83.3% vs. 25.8% in CG group and 16.7% in No-CG group). CONCLUSIONS: Caregiver relationships were more likely to be maintained for the duration of LVAD support when the caregiver was a spouse and resided in the same home as the patient. Carefully selected patients implanted without a designated caregiver had comparable outcomes to those who retained their original caregiver.


Asunto(s)
Cuidadores/psicología , Empatía , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Calidad de Vida , Esposos/psicología , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/psicología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Card Surg ; 31(5): 303-5, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27059174

RESUMEN

We describe the use of the Sapien XT, placed in the mitral position using a totally endoscopic robotic approach in a 76-year-old man with extensive circumferential mitral calcifications and severe stenosis. The patient was at high risk for traditional open surgery and a large mitral valve annulus prevented safe transcatheter deployment due to size mismatch. Our novel approach offered a minimally invasive technique for native mitral valve replacement in a high-risk patient with anatomical constraints prohibitive to conventional approaches. doi: 10.1111/jocs.12737 (J Card Surg 2016;31:303-305).


Asunto(s)
Calcinosis/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Robótica/métodos , Anciano , Calcinosis/diagnóstico , Ecocardiografía Transesofágica , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Diseño de Prótesis , Índice de Severidad de la Enfermedad
14.
Ann Plast Surg ; 74(6): 713-7, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25969975

RESUMEN

PURPOSE: The National Residency Matching Program Match is a very unique process in which applicants and programs are coupled to each other based on a ranking system. Although several studies have assessed features plastic surgery programs look for in applicants, no study in the present plastic surgery literature identifies which residency characteristics are most important to plastic surgery applicants. Therefore, we sought to perform a multi-institutional assessment as to which factors plastic surgery residency applicants consider most important when applying for residency. METHODS: A validated and anonymous questionnaire containing 37 items regarding various program characteristics was e-mailed to 226 applicants to New York University, Albany, University of Michigan, and University of Southern California plastic surgery residency programs. Applicants were asked to rate each feature on a scale from 1 to 10, with 10 being the most important. The 37 variables were ranked by the sum of the responses. The median rating and interquartile range as well as the mean for each factor was then calculated. A Wilcoxon signed rank test was used to compare medians in rank order. RESULTS: A total of 137 completed questionnaires were returned, yielding a 61% response rate. The characteristics candidates considered most important were impressions during the interview, experiences during away rotations, importance placed on resident training/support/mentoring by faculty, personal experiences with residents, and the amount of time spent in general surgery. The characteristics candidates considered least important were second-look experiences, compensation/benefits, program reputation from Internet forums, accessibility of program coordinator, opportunity for laboratory research, and fellowship positions available at the program. CONCLUSIONS: Applicants value personal contact and time spent in general surgery when selecting residency programs. As the number of integrated programs continues to grow, programs will benefit from learning what factors their applicants value most.


Asunto(s)
Actitud del Personal de Salud , Selección de Profesión , Internado y Residencia/organización & administración , Estudiantes de Medicina/psicología , Cirugía Plástica/educación , California , Humanos , Michigan , New York , Cirugía Plástica/organización & administración , Encuestas y Cuestionarios
15.
J Card Surg ; 26(6): 666-8, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22122379

RESUMEN

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is commonly used as a means of support for acute cardiopulmonary failure. In the setting of severe left ventricular (LV) dysfunction, VA-ECMO may be complicated by LV distension, which can lead to pulmonary edema and compromise myocardial recovery. Traditional decompression methods carry significant risk. We report the use of the Impella LP 2.5 for LV decompression in a 70-year-old man with decompensated heart failure who was placed on VA-ECMO for cardiogenic shock with severe pulmonary edema and respiratory failure. Both devices were successfully weaned on day 5 of VA-ECMO support, after myocardial recovery.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Función Ventricular Izquierda , Anciano , Diseño de Equipo , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino
16.
J Card Surg ; 26(3): 334-7, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21480991

RESUMEN

BACKGROUND: Use of ventricular assist devices (VADs) in patients with prosthetic valves may carry an increased risk of thromboembolism; however, clinical information is lacking. The aim of this study was to report our experience of the use of VADs in patients with prosthetic mitral valves. METHODS: A retrospective analysis of 747 VAD patients from January 1995 to May 2010 was performed. RESULTS: Thirteen patients with a prosthetic mitral valve (average age 56 ± 10 years of age, nine mechanical valve, four biological valve) were identified. Indications for VAD implantation were as a bridge to transplant in 11 patients and destination therapy in two patients. At the time of VAD implant, no intervention to the prosthetic mitral valve was performed. Eight patients received a HeartMate I (Thoratec Corporation, Pleasanton, CA, USA), three patients received a HeartMate II (Thoratec Corporation), and two patients received a Thoratec VAD (Thoratec Corporation). Among nine mechanical valve patients, six patients were anticoagulated with warfarin, and one patient with heparin, while two patients did not receive anticoagulation due to bleeding. Ten patients were successfully transplanted at an average of 123 days post-VAD implant, one died after 48 days from multiorgan failure, and two remained on VAD support. No clinical thromboembolic events were observed. No intracardiac thrombus was detected by echocardiogram or on the pathology of the explanted hearts. Five patients had experienced a bleeding event (postoperative mediastinal bleeds, gastrointestinal bleedings, retroperitoneal hematoma, and subconjuctival bleeding). CONCLUSIONS: In patients with mitral valve prostheses who require VAD support, leaving the prosthesis intact does not increase the incidence of adverse events.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Corazón Auxiliar/estadística & datos numéricos , Válvula Mitral , Adulto , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
17.
Proc Natl Acad Sci U S A ; 108(19): 7974-9, 2011 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-21508321

RESUMEN

Control over cell engraftment, survival, and function remains critical for heart repair. We have established a tissue engineering platform for the delivery of human mesenchymal progenitor cells (MPCs) by a fully biological composite scaffold. Specifically, we developed a method for complete decellularization of human myocardium that leaves intact most elements of the extracellular matrix, as well as the underlying mechanical properties. A cell-matrix composite was constructed by applying fibrin hydrogel with suspended cells onto decellularized sheets of human myocardium. We then implanted this composite onto the infarct bed in a nude rat model of cardiac infarction. We next characterized the myogenic and vasculogenic potential of immunoselected human MPCs and demonstrated that in vitro conditioning with a low concentration of TGF-ß promoted an arteriogenic profile of gene expression. When implanted by composite scaffold, preconditioned MPCs greatly enhanced vascular network formation in the infarct bed by mechanisms involving the secretion of paracrine factors, such as SDF-1, and the migration of MPCs into ischemic myocardium, but not normal myocardium. Echocardiography demonstrated the recovery of baseline levels of left ventricular systolic dimensions and contractility when MPCs were delivered via composite scaffold. This adaptable platform could be readily extended to the delivery of other reparative cells of interest and used in quantitative studies of heart repair.


Asunto(s)
Infarto del Miocardio/terapia , Miocardio/química , Ingeniería de Tejidos/métodos , Andamios del Tejido , Animales , Modelos Animales de Enfermedad , Matriz Extracelular/química , Fibrina , Humanos , Hidrogeles , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/fisiología , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Neovascularización Fisiológica , Ratas , Ratas Desnudas , Factor de Crecimiento Transformador beta/farmacología , Trasplante Heterólogo , Función Ventricular Izquierda
18.
EMBO J ; 29(6): 1055-68, 2010 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-20150894

RESUMEN

Extracellular matrices in vivo are heterogeneous structures containing gaps that cells bridge with an actomyosin network. To understand the basis of bridging, we plated cells on surfaces patterned with fibronectin (FN)-coated stripes separated by non-adhesive regions. Bridges developed large tensions where concave cell edges were anchored to FN by adhesion sites. Actomyosin complexes assembled near those sites (both actin and myosin filaments) and moved towards the centre of the non-adhesive regions in a treadmilling network. Inhibition of myosin-II (MII) or Rho-kinase collapsed bridges, whereas extension continued over adhesive areas. Inhibition of actin polymerization (latrunculin-A, jasplakinolide) also collapsed the actomyosin network. We suggest that MII has distinct functions at different bridge regions: (1) at the concave edges of bridges, MIIA force stimulates actin filament assembly at adhesions and (2) in the body of bridges, myosin cross-links actin filaments and stimulates actomyosin network healing when breaks occur. Both activities ensure turnover of actin networks needed to maintain stable bridges from one adhesive region to another.


Asunto(s)
Actomiosina/química , Contracción Muscular/fisiología , Actinas/metabolismo , Actomiosina/metabolismo , Citoesqueleto/metabolismo , Cinética , Miosinas/química , Miosinas/metabolismo , Quinasas Asociadas a rho/química , Quinasas Asociadas a rho/metabolismo
19.
Cell Transplant ; 18(3): 297-304, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19558778

RESUMEN

Heart disease is the leading cause of death in the US. Following an acute myocardial infarction, a fibrous, noncontractile scar develops, and results in congestive heart failure in more than 500,000 patients in the US each year. Muscle regeneration and the induction of new vascular growth to treat ischemic disorders of the heart can have significant therapeutic implications. Early studies in patients with chronic ischemic systolic left ventricular dysfunction (SLVD) using skeletal myoblasts or bone marrow-derived cells report improvement in left ventricular ejection function (LVEF) and clinical status, without notable safety issues. Nonetheless, the efficacy of cell transfer for cardiovascular disease is not established, in part due to a lack of control over cell retention, survival, and function following delivery. We studied the use of biocompatible hydrogels polymerizable in situ as a cell delivery vehicle, to improve cell retention, survival, and function following delivery into the ischemic myocardium. The study was conducted using human bone marrow-derived mesenchymal stem cells and fibrin glue, but the methods are applicable to any human stem cells (adult or embryonic) and a wide range of hydrogels. We first evaluated the utility of several commercially available percutaneous catheters for delivery of viscous cell/hydrogel suspensions. Next we characterized the polymerization kinetics of fibrin glue solutions to define the ranges of concentrations compatible with catheter delivery. We then demonstrate the in vivo effectiveness of this preparation and its ability to increase cell retention and survival in a nude rat model of myocardial infarction.


Asunto(s)
Hidrogeles/metabolismo , Miocardio/citología , Polímeros/metabolismo , Trasplante de Células Madre/métodos , Animales , Cateterismo , Supervivencia Celular , Adhesivo de Tejido de Fibrina/metabolismo , Fibrinógeno/metabolismo , Humanos , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/ultraestructura , Peso Molecular , Ratas , Soluciones , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA