Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biofizika ; 52(6): 1136-40, 2007.
Artículo en Ruso | MEDLINE | ID: mdl-18225667

RESUMEN

One of the most important aspects of the problem of life transfer in the cosmic space is the resistance of microorganisms to high-temperature heating during the launch and entry into the atmosphere. The high-temperature limits of the survival of microorganisms were studied under conditions modeling the laungh from the Mars and the landing on the Earth. Two strain of E. coli K12 exposed to short heating pulse were studied in order to tind out if they could resist high temperature while being in the desiccated state. The procedure was performed in vacuum. It was found that a fraction of bacteria survive heating pulses up to 250 degrees C in vacuum, while similar heating at normal atmospheric pressure leads to the total sterilization of samples.


Asunto(s)
Escherichia coli K12/fisiología , Medio Ambiente Extraterrestre , Calor , Meteoroides , Viabilidad Microbiana , Exobiología , Mutación , Temperatura
2.
J Am Soc Mass Spectrom ; 15(6): 823-31, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15144971

RESUMEN

Sudden sampling introduction into a membrane inlet mass spectrometer (MIMS) considerably improves the selectivity of the membrane inlet and is therefore applicable even for compounds with low permeabilities through a silicone membrane. In this study the basics of cyclic non-steady-state sudden increase sample injection were studied using a three-membrane inlet and a portable sector double-focusing mass spectrometer. The operational parameters of the inlet system providing the most efficient enrichment of volatile organic compounds (VOCs) in air were defined. Simulation of the diffusion process following sudden sample introduction into the three-membrane inlet was also carried out. Experimental testing of the three-membrane inlet system with the cyclic sudden sample injection mode for benzene, toluene, styrene, and xylene in air was performed. The simulation and the experimental results demonstrated that, when this mode is used, the VOCs/nitrogen relative enrichment factor of samples introduced into the mass spectrometer equipped with a three-membrane inlet is increased by a factor of approximately 10(5) compared with a direct introduction method. This effect may be used to decrease detection limits of compounds obtained with mass spectrometry to decrease matrix flow through the inlet at the same detection limits.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA