Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cancer Sci ; 99(9): 1774-7, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18616525

RESUMEN

X-ray microcomputed tomography (micro-CT) with a respiratory gating system is a useful non-invasive approach to evaluate lung tumor development in living animal models. Here micro-CT was applied for the detection of lung lesions induced by a single intraperitoneal injection (250 mg/kg) of urethane in male A/J mice, at 2-week intervals from 10 to 30 weeks after carcinogen exposure. In micro-CT cross sections, lung tumor images were easily distinguished from surrounding non-tumorous tissues, the smallest detected tumor being approximately 0.5 mm in diameter. All of the urethane-treated mice (n = 15) developed lung tumors and the number of tumors developed in each mouse was 8.6 +/- 3.9. Six tumors, determined histopathologically to be adenocarcinomas, were detected, growing at different rates during the experimental period. The most aggressive carcinoma, increasing in diameter from 0.9 to 3.5 mm within 8 weeks, was a solid-type nodule with a clear tumor margin on the micro-CT imaging. Other tumors, histopathologically adenomas, grew slowly or moderately. The results provide evidence that micro-CT is a useful non-invasive imaging approach for evaluating the characteristics and growth of lung tumors in mice.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Animales , Carcinógenos/farmacología , Modelos Animales de Enfermedad , Neoplasias Pulmonares/inducido químicamente , Neoplasias Pulmonares/patología , Masculino , Ratones , Ratones Endogámicos , Respiración , Sensibilidad y Especificidad , Uretano/farmacología
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 63(2): 257-60, 2007 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-17387247

RESUMEN

The objective of this study was to introduce the technical utility of micro-computed tomography (CT) with 27-mum resolution by cone-beam CT algorithm. Whole-body micro-CT scans were performed to honeybee. Two- and three-dimensional image analyses were performed by originally developed and available open-source software for acquired images. The original contribution of this work is to describe the technical characteristics of the X-ray micro-CT system, keeping a small experimental insect in a unique condition. Micro-CT may be used as a rapid prototyping tool to research and understand the high-resolution system with Feldkamp cone-beam reconstruction.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Animales , Abejas , Modelos Animales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA