Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Adv Prosthodont ; 13(1): 55-64, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33747395

RESUMEN

PURPOSE: To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS: The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS: The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P <.05), while there was no statistical difference between the normal and resorption group (P >.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P <.05). CONCLUSION: The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.

2.
Implant Dent ; 26(4): 516-523, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28375862

RESUMEN

PURPOSE: The stress-breaking ball (SBB) attachment can distribute the occlusal force equally between the alveolar ridge and the implants. The purpose of this study was to evaluate the implant-supported distal extension removable partial dentures (RPDs) with SBB attachment in 10 patients who were partially edentulous. METHODS: This randomized crossover study was designed to compare the function of RPDs with and without healing abutments and SBB attachments to support the posterior aspects of the RPDs. Mandibular jaw movements during mastication and the occlusal force and contact area were measured with a commercially available tracking device and pressure-sensitive sheets. Using a visual analog scale, 4 criteria-chewing, retention, stability, and comfort-were evaluated. All of the data obtained were analyzed using a 1-way analysis of variance (α = 0.05). RESULTS: There were no significant differences in either the mean time or the coefficient of variation among the SBB attachments and healing abutments of implant-supported removable partial dentures (ISRPDs) and conventional removable partial dentures (CRPDs). SBB attachments and healing abutments of ISRPDs had greater forces and contact areas than those of CRPDs with significant differences. For all criteria, patients preferred SBB attachments to healing abutments and CRPDs. CONCLUSIONS: The implant-supported distal extension RPDs with SBB attachment improved denture stability and patients' satisfaction.


Asunto(s)
Implantación Dental Endoósea/métodos , Implantes Dentales , Prótesis Dental de Soporte Implantado , Ajuste de Precisión de Prótesis , Retención de Dentadura , Dentadura Parcial Removible , Anciano , Estudios Cruzados , Pilares Dentales , Diseño de Dentadura , Femenino , Humanos , Arcada Parcialmente Edéntula/rehabilitación , Masculino , Masticación/fisiología , Satisfacción del Paciente
3.
Implant Dent ; 23(4): 456-62, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25033343

RESUMEN

OBJECTIVE: This study investigated the strain surround implants and the pressure distribution of the alveolar ridge related to implant overdentures with stress-breaking ball (SBB) attachments. METHODS: Simulation models of edentulous mandibles were embedded with 1 and 2 implants to simulate a single implant-retained overdenture (S-IOD) and a two-implant-retained overdenture (T-IOD), respectively. The implants were connected to the denture base with the following conditions: complete separation between the denture base and implant with cover screws as a conventional complete denture (CD), 3 types of settlements with an SBB attachment between them, and a conventional ball attachment (BALL). Strain surround the implant, pressure at 5 different soft tissue areas, and displacement of the denture base were measured with loading up to 50 N. RESULTS: In S-IOD and T-IOD, the strain of each SBB attachment was less than the strain shown by the BALL. The pressure at each region of the SBB attachment was less than the pressure shown with the CD and BALL. CONCLUSIONS: SBB attachments prevented strain surround the implants in loading and provided optimal stress distribution.


Asunto(s)
Implantes Dentales , Análisis del Estrés Dental , Prótesis de Recubrimiento , Humanos , Técnicas In Vitro
4.
Phys Chem Chem Phys ; 16(27): 13748-54, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24788597

RESUMEN

We measured the in situ polarization-dependent X-ray absorption fine structure of platinum nanoparticles (PtNPs) deposited on a flat highly oriented pyrolytic graphite (HOPG) substrate under electrochemical conditions using a back-side illumination method. In this method, the thin HOPG substrate with PtNPs deposited on one side was used as a window for incident and fluorescent X-rays, as well as an electrode. A bent crystal Laue analyzer (BCLA) was applied to the extraction of the Pt Lα fluorescent X-ray signals from strong scattered X-rays. Pt L3 edge XAFS spectra were observed for various electrode potentials and polarization directions.

5.
J Prosthodont Res ; 58(2): 115-20, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24636367

RESUMEN

PURPOSE: This in vitro study investigated the pressure distribution of the implant-supported removable partial dentures (RPDs) with the stress-breaking attachments under the occlusal force. METHODS: The experimental model of bilateral missing premolars and molars was modified from a commercial simulation model. Five pressure sensors were embedded near the bilateral first molars, first premolars, and medio-lingual alveolar crest. Two implants were placed near the second molars, and they were connected to the denture base using the following conditions: complete separation between the denture base and implant with cover screws (CRPD), flexible connection with a stress-breaking ball (SBB) attachment, and rigid connection without stress breaking with healing caps (HC). The pressure at five different areas of the soft tissue and the displacement of the RPDs were simultaneously measured, loading up to 50 N. The coefficient of variation (CV) for each connection was calculated from all data of the pressure at five areas to evaluate the pressure distribution. RESULTS: The pressure on medio-lingual alveolar crest and molars of the HC was less than SBB and CRPD. In contrast, the pressure on premolars of SBB was greater than for the HC and CRPD. The CV of SBB was less than that of HC and CRPD. Denture displacement of HC and SBB was less than for CRPD. CONCLUSIONS: Within the in vitro limitations, precise denture settlements and pressure distribution under the denture base could be controlled using an SBB attachment. An SBB attachment might be able to protect the implant from harmful force.


Asunto(s)
Fuerza de la Mordida , Implantes Dentales , Ajuste de Precisión de Prótesis , Dentadura Parcial Removible , Diente Molar/fisiología , Fenómenos Biomecánicos , Técnicas In Vitro , Presión
6.
Biol Pharm Bull ; 36(11): 1829-34, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24189427

RESUMEN

To clarify whether peripheral inflammation has a remote effect on the central nervous system, the electrolyte disposition between the circulating blood and central nervous system was evaluated in rats with carrageenan-induced acute peripheral inflammation (API). λ-Carrageenan was subcutaneously injected in the hind paw of the rat, and lithium was utilized as a surrogate marker of sodium. When the plasma and cerebrospinal fluid (CSF) concentrations of lithium were examined following lithium being intravenously administered, it was revealed that the CSF concentration of lithium in API rats is reduced compared to that in normal rats, while the plasma concentration profile of lithium in API rats is indistinguishable from that in normal rats. The pharmacokinetic analysis showed that the lithium disposition from the plasma to CSF markedly decreased by 35.8% in API rats compared to that in normal rats. On the other hand, when lithium was immediately administered into the lateral ventricle, its elimination profiles in CSF were not different between normal and API rats. It is therefore probable that the lithium disposition from the plasma to CSF alters in API rats, reflecting the entry process of electrolytes from the circulating blood to brain tissue being suppressed in response to peripheral inflammation.


Asunto(s)
Electrólitos/líquido cefalorraquídeo , Inflamación/metabolismo , Cloruro de Litio/farmacocinética , Animales , Carragenina , Inflamación/inducido químicamente , Cloruro de Litio/sangre , Cloruro de Litio/líquido cefalorraquídeo , Masculino , Orosomucoide/metabolismo , Ratas , Ratas Wistar
7.
Biopharm Drug Dispos ; 31(8-9): 455-63, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20848389

RESUMEN

The altered electrolyte handling of the choroid plexus was investigated in rats with acute renal failure (ARF) using lithium and rubidium as surrogate markers for sodium and potassium, respectively. Firstly, the transport of these two markers from the plasma to cerebrospinal fluid (CSF) was evaluated after they were concurrently injected into the femoral vein. As a result, their disposition from the plasma to CSF was shown to decrease in ARF rats, but the relationship profile between those two markers was not different from that observed in normal rats, indicating that the decreased disposition of lithium and rubidium occurs without affecting the stoichiometric balance. To clarify the mechanisms accounting for the decreased disposition, an inhibition study was then performed. When bumetanide, an inhibitor of the Na(+) /K(+) /2Cl(-) co-transporter, was directly introduced into the cerebroventricle prior to lithium and rubidium being intravenously administered, a marked increase in the markers' disposition was observed. However, such an increased disposition did not occur when bumetanide was injected into the femoral vein. Other inhibitors, such as amiloride for the Na(+) /H(+) exchanger and ouabain for Na(+) /K(+) -ATPase, did not show any effects on marker disposition regardless of the inhibitor being administered into either the cerebroventricle or femoral vein. These findings suggest that the decreased marker disposition in ARF rats is due to an increased efflux process of the choroid plexus mediated by the Na(+) /K(+) /2Cl(-) co-transporter. That is, electrolyte efflux from the CSF to plasma increases, and thereby the electrolyte influx from the plasma to CSF is counteracted.


Asunto(s)
Lesión Renal Aguda/metabolismo , Cloruros/metabolismo , Plexo Coroideo/metabolismo , Electrólitos/metabolismo , Cloruro de Litio/metabolismo , Rubidio/metabolismo , Lesión Renal Aguda/inducido químicamente , Animales , Área Bajo la Curva , Bumetanida/farmacología , Cloruros/sangre , Cloruros/líquido cefalorraquídeo , Electrólitos/sangre , Electrólitos/líquido cefalorraquídeo , Glicerol , Transporte Iónico , Cloruro de Litio/sangre , Cloruro de Litio/líquido cefalorraquídeo , Masculino , Potasio/metabolismo , Ratas , Ratas Wistar , Rubidio/sangre , Rubidio/líquido cefalorraquídeo , Sodio/metabolismo , Simportadores de Cloruro de Sodio-Potasio/metabolismo , Miembro 2 de la Familia de Transportadores de Soluto 12
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...