RESUMEN
The results of a study on the geometric shape of the damper on the efficiency of the ultrasonic piezoelectric transducer are presented. In particular, a damper in the form of a truncated cone is considered, the generatrix of which has an inclination angle α relative to the diameter of the piezoceramic plate. The shape of the damper in the form of a truncated cone is chosen based on the a priori assumption that this helps to increase the path of the wave in the damper material due to numerous reflections in it. A criterion for the efficiency of damper operation is proposed. The optimal (from the point of view of the damper efficiency) value of the angle α was determined theoretically and experimentally. The technology of its production is described. Satisfactory agreement between the results of theoretical and experimental studies was noted.
RESUMEN
Neutrinoless double beta decay (0νßß) is a yet unobserved nuclear process that would demonstrate Lepton number violation, a clear evidence of beyond standard model physics. The process two neutrino double beta decay (2νßß) is allowed by the standard model and has been measured in numerous experiments. In this Letter, we report a measurement of 2νßß decay half-life of ^{100}Mo to the ground state of ^{100}Ru of [7.07±0.02(stat)±0.11(syst)]×10^{18} yr by the CUPID-Mo experiment. With a relative precision of ±1.6% this is the most precise measurement to date of a 2νßß decay rate in ^{100}Mo. In addition, we constrain higher-order corrections to the spectral shape, which provides complementary nuclear structure information. We report a novel measurement of the shape factor ξ_{3,1}=0.45±0.03(stat)±0.05(syst) based on a constraint on the ratio of higher-order terms from theory, which can be reliably calculated. This is compared to theoretical predictions for different nuclear models. We also extract the first value for the effective axial vector coupling constant obtained from a spectral shape study of 2νßß decay.
RESUMEN
The influence of static compressional stress on the anisotropy of piezoelectric ceramics of BaTiO3 and PZT types is considered theoretically and experimentally. Static compression changes the domain structure of piezoceramics. These changes occur due to the reorientation of mostly 90° domain axes. As a result, all the parameters of the material change-elastic, piezoelectric, and dielectric. Some of them increase, and some, on the contrary, decrease. Changes occur in a nonlinear way, and higher-order parameters appear. The relationship between the total volume of the reoriented domains and the change in elastic moduli and piezomoduli is theoretically considered. The corresponding theoretical dependences are obtained. To confirm these theoretical dependences, experimental measurements were performed using the ultrasonic pulse-interference method at a frequency of 8 MHz. There is practically no oscillation movement of domain boundaries at this frequency, therefore, the change in the system of elastic and piezoelectric moduli is structural, not dynamic. The possibility of predicting changes in the structure of modules as a result of static compression is shown.
RESUMEN
The CUPID-Mo experiment at the Laboratoire Souterrain de Modane (France) is a demonstrator for CUPID, the next-generation ton-scale bolometric 0νßß experiment. It consists of a 4.2 kg array of 20 enriched Li_{2}^{100}MoO_{4} scintillating bolometers to search for the lepton-number-violating process of 0νßß decay in ^{100}Mo. With more than one year of operation (^{100}Mo exposure of 1.17 kg×yr for physics data), no event in the region of interest and, hence, no evidence for 0νßß is observed. We report a new limit on the half-life of 0νßß decay in ^{100}Mo of T_{1/2}>1.5×10^{24} yr at 90% C.I. The limit corresponds to an effective Majorana neutrino mass ⟨m_{ßß}⟩<(0.31-0.54) eV, dependent on the nuclear matrix element in the light Majorana neutrino exchange interpretation.
RESUMEN
The Majorana Demonstrator is an ultralow-background experiment searching for neutrinoless double-beta decay in ^{76}Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly ionizing particles with an electrical charge less than e are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the Majorana Demonstrator by searching for multiple-detector events with individual-detector energy depositions down to 1 keV. This search is background-free, and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as e/1000.
RESUMEN
We present new limits on exotic keV-scale physics based on 478 kg d of Majorana Demonstrator commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal limits above our background. Our most stringent DM constraints are set for 11.8 keV mass particles, limiting g_{Ae}<4.5×10^{-13} for pseudoscalars and (α^{'}/α)<9.7×10^{-28} for vectors. We also report a 14.4 keV solar axion coupling limit of g_{AN}^{eff}×g_{Ae}<3.8×10^{-17}, a 1/2ß^{2}<8.5×10^{-48} limit on the strength of PEPV electron transitions, and a lower limit on the electron lifetime of τ_{e}>1.2×10^{24} yr for e^{-}â invisible.
RESUMEN
The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of 208Tl and 214Bi in thin materials, initially developed to measure the radiopurity of the double ß decay source foils of the SuperNEMO experiment at the µBq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some µBq/kg.
RESUMEN
This paper reports on the development of a technology involving 100 Mo -enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ( â¼ 1 kg ), high optical quality, radiopure 100 Mo -containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2-0.4 kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the Q-value of the double-beta transition of 100 Mo (3034 keV) is 4-6 keV FWHM. The rejection of the α -induced dominant background above 2.6 MeV is better than 8 σ . Less than 10 µ Bq/kg activity of 232 Th ( 228 Th ) and 226 Ra in the crystals is ensured by boule recrystallization. The potential of 100 Mo -enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10 kg × d exposure: the two neutrino double-beta decay half-life of 100 Mo has been measured with the up-to-date highest accuracy as T 1 / 2 = [6.90 ± 0.15(stat.) ± 0.37(syst.)] × 10 18 years . Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of 100 Mo .
RESUMEN
We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-ß decay of ^{150}Nd using a total exposure of 0.19 kg yr recorded with the NEMO-3 detector at the Modane Underground Laboratory. We find no evidence of this decay and set lower limits on the half-life in the range T_{1/2}>(1.1-3.2)×10^{21} yr at the 90% C.L., depending on the model used for the kinematic distributions of the emitted electrons.
RESUMEN
We report results from the NEMO-3 experiment based on an exposure of 1275 days with 661 g of (130)Te in the form of enriched and natural tellurium foils. The ßß decay rate of (130)Te is found to be greater than zero with a significance of 7.7 standard deviations and the half-life is measured to be T(½)(2ν) = [7.0 ± 0.9(stat) ± 1.1(syst)] × 10(20) yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.
RESUMEN
By means of a computational method, the possibility of radiating a short acoustic pulse by a transducer in the form of a piezoceramic sphere internally filled with liquid is investigated. An electric inductive-resistive circuit is connected to the electric input of the transducer. Solution is obtained based on scheme-analogs theory for piezoceramic transducers, and spectral Fourier transform theory. The values of parameters of the system, providing minimal durations of radiated signals, are determined. Computation was carried out for different values of relative thicknesses of the transducer wall. The estimates of durations and amplitudes of the acoustic signals radiated into the external medium are obtained.
Asunto(s)
Acústica/instrumentación , Cerámica , Transductores , Simulación por Computador , Impedancia Eléctrica , Diseño de Equipo , Análisis de Fourier , Modelos Teóricos , Movimiento (Física) , Análisis Numérico Asistido por Computador , Presión , Procesamiento de Señales Asistido por Computador , Sonido , Espectrografía del Sonido , Factores de Tiempo , VibraciónRESUMEN
By means of numerical computation, pulse mode of a piezoelectric radiator in the form of a plate, loaded with a liquid and connected to R-L circuits in various combinations, is investigated. The computations were carried out having taken into account the internal resistance of the electric generator. Numerical results, based on the theory, are provided for examples of parallel and series circuits connected to a piezoelectric plate. The optimal values of parameters are determined, providing minimal duration of radiated acoustic pulses.
RESUMEN
Subcutaneous immunization, made in a single injection, with outer membrane preparations obtained from F.tularensis vaccine strain 15 and virulent strain A'Cole results in intensive immunity to tularemia in guinea pigs, ensuring the protection of 60-100% of the animals within a month after challenge with F.tularensis virulent strain 503 in a dose of 1,000 DCL. The development of protective effect induced by F.tularensis outer membranes can be observed during the first 24 hours and reaches its maximum by days 15-21 after immunization.
Asunto(s)
Vacunas Bacterianas/inmunología , Francisella tularensis/inmunología , Tularemia/prevención & control , Animales , Vacunas Bacterianas/administración & dosificación , Membrana Celular/inmunología , Relación Dosis-Respuesta Inmunológica , Evaluación Preclínica de Medicamentos , Francisella tularensis/patogenicidad , Cobayas , Inmunización , Factores de Tiempo , Tularemia/mortalidad , VirulenciaRESUMEN
The preventive activity of five monoclonal antibodies (McAb) in experimental tularemia was evaluated. McAb produced by hybridoma FB11-k (IgG2a), specific to F. tularensis lipopolysaccharide, prevented the death of mice and guinea pigs infected with F. tularensis virulent strain 503 of the holarctic subspecies.
Asunto(s)
Anticuerpos Monoclonales/inmunología , Especificidad de Anticuerpos/inmunología , Francisella tularensis/inmunología , Lipopolisacáridos/inmunología , Tularemia/prevención & control , Animales , Anticuerpos Monoclonales/aislamiento & purificación , Evaluación Preclínica de Medicamentos , Francisella tularensis/patogenicidad , Cobayas , Hibridomas/inmunología , Ratones , Ratones Endogámicos BALB C , Factores de Tiempo , Tularemia/inmunología , Virulencia/inmunologíaRESUMEN
The article presents immunological data substantiating the combined immunization of humans with the mixture of choleragen toxoid and chemical adsorbed typhoid vaccine, introduced subcutaneously by means of a jet injector.
Asunto(s)
Toxina del Cólera/efectos adversos , Vacunas Tifoides-Paratifoides/efectos adversos , Vibrio cholerae , Adolescente , Adulto , Anticuerpos Antibacterianos/análisis , Toxina del Cólera/administración & dosificación , Toxina del Cólera/inmunología , Combinación de Medicamentos , Evaluación de Medicamentos , Humanos , Inmunización , Inyecciones a Chorro , Inyecciones Subcutáneas , Masculino , Salmonella typhi/inmunología , Factores de Tiempo , Vacunas Tifoides-Paratifoides/administración & dosificación , Vacunas Tifoides-Paratifoides/inmunología , Vibrio cholerae/inmunologíaRESUMEN
The formulas indicating the relationship between the magnitude of aerosol aspiration doses of the vaccine preparation and the parameters of the dispersed composition of aerosol are presented. The results of calculation of the relationship between the proportion of the particles of the respirable fraction and the median mass diameter, as well as the root-mean-square deviation of the logarithms of the diameters, are given. To ensure the high effectiveness of immunization with the vaccine preparation, the use of aerosols with the median mass diameter between 1.0 mu and 3.5 mu is shown to be expedient.