Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
J Biomech ; 169: 112135, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38744145

RESUMEN

Articular cartilage exhibits site-specific biomechanical properties. However, no study has comprehensively characterized site-specific cartilage properties from the same knee joints at different stages of osteoarthritis (OA). Cylindrical osteochondral explants (n = 381) were harvested from donor-matched lateral and medial tibia, lateral and medial femur, patella, and trochlea of cadaveric knees (N = 17). Indentation test was used to measure the elastic and viscoelastic mechanical properties of the samples, and Osteoarthritis Research Society International (OARSI) grading system was used to categorize the samples into normal (OARSI 0-1), early OA (OARSI 2-3), and advanced OA (OARSI 4-5) groups. OA-related changes in cartilage mechanical properties were site-specific. In the lateral and medial tibia and trochlea sites, equilibrium, instantaneous and dynamic moduli were higher (p < 0.001) in normal tissue than in early and advanced OA tissue. In lateral and medial femur, equilibrium, instantaneous and dynamic moduli were smaller in advanced OA, but not in early OA, than in normal tissue. The phase difference (0.1-0.25 Hz) between stress and strain was significantly smaller (p < 0.05) in advanced OA than in normal tissue across all sites except medial tibia. Our results indicated that in contrast to femoral and patellar cartilage, equilibrium, instantaneous and dynamic moduli of the tibia and trochlear cartilage decreased in early OA. These may suggest that the tibia and trochlear cartilage degrades faster than the femoral and patellar cartilage. The information is relevant for developing site-specific computational models and engineered cartilage constructs.


Asunto(s)
Cartílago Articular , Articulación de la Rodilla , Osteoartritis de la Rodilla , Humanos , Cartílago Articular/fisiopatología , Cartílago Articular/fisiología , Cartílago Articular/patología , Articulación de la Rodilla/fisiopatología , Anciano , Osteoartritis de la Rodilla/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Fenómenos Biomecánicos , Elasticidad , Viscosidad , Tibia/fisiopatología , Fémur/fisiopatología , Fémur/fisiología , Anciano de 80 o más Años , Adulto , Estrés Mecánico
2.
Comput Methods Programs Biomed ; 248: 108132, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38503071

RESUMEN

BACKGROUND AND OBJECTIVE: Incidence of paediatric anterior cruciate ligament (ACL) rupture has increased substantially over recent decades. Following ACL rupture, ACL reconstruction (ACLR) surgery is typically performed to restore passive knee stability. This surgery involves replacing the failed ACL with a graft, however, surgeons must select from range of surgical parameters (e.g., type, size, insertion, and pre-tension) with no robust evidence guiding these decisions. This study presents a systemmatic computational approach to study effects of surgical parameter variation on kinematics of paediatric knees. METHODS: This study used sequentially-linked neuromusculoskeletal (NMSK) finite element (FE) models of three paediatric knees to estimate the: (i) sensitivity of post-operative knee kinematics to four surgical parameters (type, size, insertion, and pre-tension) through multi-input multi-output sensitivity analysis; (ii) influence of motion and loading conditions throughout stance phase of walking gait on sensitivity indices; and (iii) influence of subject-specific anatomy (i.e., knee size) on sensitivivty indices. A previously validated FE model of the intact knee for each subject served as a reference against which ACLR knee kinematics were compared. RESULTS: Sensitivity analyses revealed significant influences of surgical parameters on ACLR knee kinematics, albeit without discernible trend favouring any one parameter. Graft size and pre-tension were primary drivers of variation in knee translations and rotations, however, their effects fluctuated across stance indicating motion and loading conditions affect system sensitivity to surgical parameters. Importantly, the sensitivity of knee kinematics to surgical parameter varied across subjects, indicating geometry (i.e., knee size) influenced system sensitivity. Notably, alterations in graft parameters yielded substantial effects on kinematics (normalized root-mean-square-error > 10 %) compared to intact knee models, indicating surgical parameters vary post-operative knee kinematics. CONCLUSIONS: Overall, this initial study highlights the importance of surgical parameter selection on post-operative kinematics in the paediatric ACLR knee, and provides evidence of the need for personalized surgical planning to ultimately enhance patient outcomes.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Humanos , Niño , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía
3.
Connect Tissue Res ; 65(2): 117-132, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38530304

RESUMEN

Osteoarthritis (OA) is a multifactorial joint disease characterized by articular cartilage degradation. Risk factors for OA include joint trauma, obesity, and inflammation, each of which can affect joint health independently, but their interaction and the associated consequences of such interaction were largely unexplored. Here, we studied compositional and structural alterations in knee joint cartilages of Sprague-Dawley rats exposed to two OA risk factors: joint injury and diet-induced obesity. Joint injury was imposed by surgical transection of anterior cruciate ligaments (ACLx), and obesity was induced by a high fat/high sucrose diet. Depth-dependent proteoglycan (PG) content and collagen structural network of cartilage were measured from histological sections collected previously in Collins et al.. (2015). We found that ACLx primarily affected the superficial cartilages. Compositionally, ACLx led to reduced PG content in lean animals, but increased PG content in obese rats. Structurally, ACLx caused disorganization of collagenous network in both lean and obese animals through increased collagen orientation in the superficial tissues and a change in the degree of fibrous alignment. However, the cartilage degradation attributed to joint injury and obesity was not necessarily additive when the two risk factors were present simultaneously, particularly for PG content and collagen orientation in the superficial tissues. Interestingly, sham surgeries caused a through-thickness disorganization of collagen network in lean and obese animals. We conclude that the interactions of multiple OA risk factors are complex and their combined effects cannot be understood by superposition principle. Further research is required to elucidate the interactive mechanism between OA subtypes.


Asunto(s)
Cartílago Articular , Osteoartritis , Ratas , Animales , Ratas Sprague-Dawley , Articulación de la Rodilla/patología , Osteoartritis/patología , Proteoglicanos/metabolismo , Obesidad/metabolismo , Cartílago Articular/patología , Colágeno/metabolismo
4.
J Orthop Res ; 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38323840

RESUMEN

In this study, we investigated the discriminative capacity of knee morphology in automatic detection of osteophytes defined by the Osteoarthritis Research Society International atlas, using X-ray and magnetic resonance imaging (MRI) data. For the X-ray analysis, we developed a deep learning (DL) based model to segment femur and tibia. In case of MRIs, we utilized previously validated segmentations of femur, tibia, corresponding cartilage tissues, and menisci. Osteophyte detection was performed using DL models in four compartments: medial femur (FM), lateral femur (FL), medial tibia (TM), and lateral tibia (TL). To analyze the confounding effects of soft tissues, we investigated their morphology in combination with bones, including bones+cartilage, bones+menisci, and all the tissues. From X-ray-based 2D morphology, the models yielded balanced accuracy of 0.73, 0.69, 0.74, and 0.74 for FM, FL, TM, TL, respectively. Using 3D bone morphology from MRI, balanced accuracy was 0.80, 0.77, 0.71, and 0.76, respectively. The performance was higher than in 2D for all the compartments except for TM, with significant improvements observed for femoral compartments. Adding menisci or cartilage morphology consistently improved balanced accuracy in TM, with the greatest improvement seen for small osteophyte. Otherwise, the models performed similarly to bones-only. Our experiments demonstrated that MRI-based models show higher detection capability than X-ray based models for identifying knee osteophytes. This study highlighted the feasibility of automated osteophyte detection from X-ray and MRI data and suggested further need for development of osteophyte assessment criteria in addition to OARSI, particularly, for early osteophytic changes.

5.
Ann Biomed Eng ; 52(5): 1255-1269, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38361137

RESUMEN

PURPOSE: Clinical cone-beam computed tomography (CBCT) devices are limited to imaging features of half a millimeter in size and cannot quantify the tissue microstructure. We demonstrate a robust deep-learning method for enhancing clinical CT images, only requiring a limited set of easy-to-acquire training data. METHODS: Knee tissue from five cadavers and six total knee replacement patients, and 14 teeth from eight patients were scanned using laboratory CT as training data for the developed super-resolution (SR) technique. The method was benchmarked against ex vivo test set, 52 osteochondral samples are imaged with clinical and laboratory CT. A quality assurance phantom was imaged with clinical CT to quantify the technical image quality. To visually assess the clinical image quality, musculoskeletal and maxillofacial CBCT studies were enhanced with SR and contrasted to interpolated images. A dental radiologist and surgeon reviewed the maxillofacial images. RESULTS: The SR models predicted the bone morphological parameters on the ex vivo test set more accurately than conventional image processing. The phantom analysis confirmed higher spatial resolution on the SR images than interpolation, but image grayscales were modified. Musculoskeletal and maxillofacial CBCT images showed more details on SR than interpolation; however, artifacts were observed near the crown of the teeth. The readers assessed mediocre overall scores for both SR and interpolation. The source code and pretrained networks are publicly available. CONCLUSION: Model training with laboratory modalities could push the resolution limit beyond state-of-the-art clinical musculoskeletal and dental CBCT. A larger maxillofacial training dataset is recommended for dental applications.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Cabeza
6.
Ann Biomed Eng ; 52(5): 1313-1325, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38421479

RESUMEN

The distal semitendinosus tendon is commonly harvested for anterior cruciate ligament reconstruction, inducing substantial morbidity at the knee. The aim of this study was to probe how morphological changes of the semitendinosus muscle after harvest of its distal tendon for anterior cruciate ligament reconstruction affects knee flexion strength and whether the knee flexor synergists can compensate for the knee flexion weakness. Ten participants 8-18 months after anterior cruciate ligament reconstruction with an ipsilateral distal semitendinosus tendon autograft performed isometric knee flexion strength testing (15°, 45°, 60°, and 90°; 0° = knee extension) positioned prone on an isokinetic dynamometer. Morphological parameters extracted from magnetic resonance images were used to inform a musculoskeletal model. Knee flexion moments estimated by the model were then compared with those measured experimentally at each knee angle position. A statistically significant between-leg difference in experimentally-measured maximal isometric strength was found at 60° and 90°, but not 15° or 45°, of knee flexion. The musculoskeletal model matched the between-leg differences observed in experimental knee flexion moments at 15° and 45° but did not well estimate between-leg differences with a more flexed knee, particularly at 90°. Further, the knee flexor synergists could not physiologically compensate for weakness in deep knee flexion. These results suggest additional factors other than knee flexor muscle morphology play a role in knee flexion weakness following anterior cruciate ligament reconstruction with a distal semitendinosus tendon graft and thus more work at neural and microscopic levels is required for informing treatment and rehabilitation in this demographic.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Músculos Isquiosurales , Tendones Isquiotibiales , Humanos , Músculo Esquelético/patología , Músculos Isquiosurales/cirugía , Ligamento Cruzado Anterior/cirugía , Tendones Isquiotibiales/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos
7.
J Orthop Res ; 42(2): 415-424, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37593815

RESUMEN

Cartilage and synovial fluid are challenging to observe separately in native computed tomography (CT). We report the use of triple contrast agent (bismuth nanoparticles [BiNPs], CA4+, and gadoteridol) to image and segment cartilage in cadaveric knee joints with a clinical CT scanner. We hypothesize that BiNPs will remain in synovial fluid while the CA4+ and gadoteridol will diffuse into cartilage, allowing (1) segmentation of cartilage, and (2) evaluation of cartilage biomechanical properties based on contrast agent concentrations. To investigate these hypotheses, triple contrast agent was injected into both knee joints of a cadaver (N = 1), imaged with a clinical CT at multiple timepoints during the contrast agent diffusion. Knee joints were extracted, imaged with micro-CT (µCT), and biomechanical properties of the cartilage surface were determined by stress-relaxation mapping. Cartilage was segmented and contrast agent concentrations (CA4+ and gadoteridol) were compared with the biomechanical properties at multiple locations (n = 185). Spearman's correlation between cartilage thickness from clinical CT and reference µCT images verifies successful and reliable segmentation. CA4+ concentration is significantly higher in femoral than in tibial cartilage at 60 min and further timepoints, which corresponds to the higher Young's modulus observed in femoral cartilage. In this pilot study, we show that (1) large BiNPs do not diffuse into cartilage, facilitating straightforward segmentation of human knee joint cartilage in a clinical setting, and (2) CA4+ concentration in cartilage reflects the biomechanical differences between femoral and tibial cartilage. Thus, the triple contrast agent CT shows potential in cartilage morphology and condition estimation in clinical CT.


Asunto(s)
Cartílago Articular , Medios de Contraste , Humanos , Prueba de Estudio Conceptual , Proyectos Piloto , Tomografía Computarizada por Rayos X/métodos , Articulación de la Rodilla/diagnóstico por imagen
8.
J Orthop Res ; 42(1): 54-65, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37415557

RESUMEN

Tissue swelling represents an early sign of osteoarthritis, reflecting osmolarity changes from iso- to hypo-osmotic in the diseased joints. Increased tissue hydration may drive cell swelling. The opposing cartilages in a joint may swell differently, thereby predisposing the more swollen cartilage and cells to mechanical injuries. However, our understanding of the tissue-cell interdependence in osmotically loaded joints is limited as tissue and cell swellings have been studied separately. Here, we measured tissue and cell responses of opposing patellar (PAT) and femoral groove (FG) cartilages in lapine knees exposed to an extreme hypo-osmotic challenge. We found that the tissue matrix and most cells swelled during the hypo-osmotic challenge, but to a different extent (tissue: <3%, cells: 11%-15%). Swelling-induced tissue strains were anisotropic, showing 2%-4% stretch and 1%-2% compression along the first and third principal directions, respectively. These strains were amplified by 5-8 times in the cells. Interestingly, the first principal strains of tissue and cells occurred in different directions (60-61° for tissue vs. 8-13° for cells), suggesting different mechanisms causing volume expansion in the tissue and the cells. Instead of the continuous swelling observed in the tissue matrix, >88% of cells underwent regulatory volume decrease to return to their pre-osmotic challenge volumes. Cell shapes changed in the early phase of swelling but stayed constant thereafter. Kinematic changes to tissue and cells were larger for PAT cartilage than for FG cartilage. We conclude that the swelling-induced deformation of tissue and cells is anisotropic. Cells actively restored volume independent of the surrounding tissues and seemed to prioritize volume restoration over shape restoration. Our findings shed light on tissue-cell interdependence in changing osmotic environments that is crucial for cell mechano-transduction in swollen/diseased tissues.


Asunto(s)
Cartílago Articular , Condrocitos , Presión Osmótica , Condrocitos/fisiología , Concentración Osmolar , Ósmosis
9.
J Orthop Res ; 42(2): 326-338, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37644668

RESUMEN

Gait modification is a common nonsurgical approach to alter the mediolateral distribution of knee contact forces, intending to decelerate or postpone the progression of mechanically induced knee osteoarthritis (KOA). Nevertheless, the success rate of these approaches is controversial, with no studies conducted to assess alterations in tissue-level knee mechanics governing cartilage degradation response in KOA patients undertaking gait modifications. Thus, here we investigated the effect of different conventional gait conditions and modifications on tissue-level knee mechanics previously suggested as indicators of collagen network damage, cell death, and loss of proteoglycans in knee cartilage. Five participants with medial KOA were recruited and musculoskeletal finite element analyses were conducted to estimate subject-specific tissue mechanics of knee cartilages during two gait conditions (i.e., barefoot and shod) and six gait modifications (i.e., 0°, 5°, and 10° lateral wedge insoles, toe-in, toe-out, and wide stance). Based on our results, the optimal gait modification varied across the participants. Overall, toe-in, toe-out, and wide stance showed the greatest reduction in tissue mechanics within medial tibial and femoral cartilages. Gait modifications could effectually alter maximum principal stress (~20 ± 7%) and shear strain (~9 ± 4%) within the medial tibial cartilage. Nevertheless, lateral wedge insoles did not reduce joint- and tissue-level mechanics considerably. Significance: This proof-of-concept study emphasizes the importance of the personalized design of gait modifications to account for biomechanical risk factors associated with cartilage degradation.


Asunto(s)
Articulación de la Rodilla , Osteoartritis de la Rodilla , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiología , Marcha/fisiología , Extremidad Inferior
10.
J Biomech ; 160: 111800, 2023 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-37797566

RESUMEN

Fibril-reinforced poroviscoelastic material models are considered state-of-the-art in modeling articular cartilage biomechanics. Yet, cartilage material parameters are often based on bovine tissue properties in computational knee joint models, although bovine properties are distinctly different from those of humans. Thus, we aimed to investigate how cartilage mechanical responses are affected in the knee joint model during walking when fibril-reinforced poroviscoelastic properties of cartilage are based on human data instead of bovine. We constructed a finite element knee joint model in which tibial and femoral cartilages were modeled as fibril-reinforced poroviscoelastic material using either human or bovine data. Joint loading was based on subject-specific gait data. The resulting mechanical responses of knee cartilage were compared between the knee joint models with human or bovine fibril-reinforced poroviscoelastic cartilage properties. Furthermore, we conducted a sensitivity analysis to determine which fibril-reinforced poroviscoelastic material parameters have the greatest impact on cartilage mechanical responses in the knee joint during walking. In general, bovine cartilage properties yielded greater maximum principal stresses and fluid pressures (both up to 30%) when compared to the human cartilage properties during the loading response in both femoral and tibial cartilage sites. Cartilage mechanical responses were very sensitive to the collagen fibril-related material parameter variations during walking while they were unresponsive to proteoglycan matrix or fluid flow-related material parameter variations. Taken together, human cartilage material properties should be accounted for when the goal is to compare absolute mechanical responses of knee joint cartilage as bovine material parameters lead to substantially different cartilage mechanical responses.

11.
Sci Rep ; 13(1): 18328, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37884632

RESUMEN

Finite element (FE) models have been widely used to investigate knee joint biomechanics. Most of these models have been developed to study adult knees, neglecting pediatric populations. In this study, an atlas-based approach was employed to develop subject-specific FE models of the knee for eight typically developing pediatric individuals. Initially, validation simulations were performed at four passive tibiofemoral joint (TFJ) flexion angles, and the resulting TFJ and patellofemoral joint (PFJ) kinematics were compared to corresponding patient-matched measurements derived from magnetic resonance imaging (MRI). A neuromusculoskeletal-(NMSK)-FE pipeline was then used to simulate knee biomechanics during stance phase of walking gait for each participant to evaluate model simulation of a common motor task. Validation simulations demonstrated minimal error and strong correlations between FE-predicted and MRI-measured TFJ and PFJ kinematics (ensemble average of root mean square errors < 5 mm for translations and < 4.1° for rotations). The FE-predicted kinematics were strongly correlated with published reports (ensemble average of Pearson's correlation coefficients (ρ) > 0.9 for translations and ρ > 0.8 for rotations), except for TFJ mediolateral translation and abduction/adduction rotation. For walking gait, NMSK-FE model-predicted knee kinematics, contact areas, and contact pressures were consistent with experimental reports from literature. The strong agreement between model predictions and experimental reports underscores the capability of sequentially linked NMSK-FE models to accurately predict pediatric knee kinematics, as well as complex contact pressure distributions across the TFJ articulations. These models hold promise as effective tools for parametric analyses, population-based clinical studies, and enhancing our understanding of various pediatric knee injury mechanisms. They also support intervention design and prediction of surgical outcomes in pediatric populations.


Asunto(s)
Articulación de la Rodilla , Articulación Patelofemoral , Adulto , Humanos , Niño , Análisis de Elementos Finitos , Articulación de la Rodilla/patología , Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Fenómenos Biomecánicos , Rango del Movimiento Articular
12.
Front Bioeng Biotechnol ; 11: 1214693, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37576991

RESUMEN

Introduction: Knee osteoarthritis (KOA) is characterized by articular cartilage degeneration. It has been widely accepted that the mechanical joint environment plays a significant role in the onset and progression of this disease. In silico models have been used to study the interplay between mechanical loading and cartilage degeneration, hereby relying mainly on two key mechanoregulatory factors indicative of collagen degradation and proteoglycans depletion. These factors are the strain in collagen fibril direction (SFD) and maximum shear strain (MSS) respectively. Methods: In this study, a multi-scale in silico modeling approach was used based on a synergy between musculoskeletal and finite element modeling to evaluate the SFD and MSS. These strains were evaluated during gait based on subject-specific gait analysis data collected at baseline (before a 2-year follow-up) for a healthy and progressive early-stage KOA subject with similar demographics. Results: The results show that both SFD and MSS factors allowed distinguishing between a healthy subject and a KOA subject, showing progression at 2 years follow-up, at the instance of peak contact force as well as during the stance phase of the gait cycle. At the peak of the stance phase, the SFD were found to be more elevated in the KOA patient with the median being 0.82% higher in the lateral and 0.4% higher in the medial compartment of the tibial cartilage compared to the healthy subject. Similarly, for the MSS, the median strains were found to be 3.6% higher in the lateral and 0.7% higher in the medial tibial compartment of the KOA patient compared to the healthy subject. Based on these intersubject SFD and MSS differences, we were additionally able to identify that the tibial compartment of the KOA subject at risk of progression. Conclusion/discussion: We confirmed the mechanoregulatory factors as potential biomarkers to discriminate patients at risk of disease progression. Future studies should evaluate the sensitivity of the mechanoregulatory factors calculated based on this multi-scale modeling workflow in larger patient and control cohorts.

13.
Ann Biomed Eng ; 51(10): 2192-2203, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37284996

RESUMEN

Computational models can be used to predict the onset and progression of knee osteoarthritis. Ensuring the transferability of these approaches among computational frameworks is urgent for their reliability. In this work, we assessed the transferability of a template-based modeling strategy, based on the finite element (FE) method, by implementing it on two different FE softwares and comparing their results and conclusions. For that, we simulated the knee joint cartilage biomechanics of 154 knees using healthy baseline conditions and predicted the degeneration that occurred after 8 years of follow-up. For comparisons, we grouped the knees using their Kellgren-Lawrence grade at the 8-year follow-up time and the simulated volume of cartilage tissue that exceeded age-dependent thresholds of maximum principal stress. We considered the medial compartment of the knee in the FE models and used ABAQUS and FEBio FE softwares for simulations. The two FE softwares detected different volumes of overstressed tissue in corresponding knee samples (p < 0.01). However, both programs correctly distinguished between the joints that remained healthy and those that developed severe osteoarthritis after the follow-up (AUC = 0.73). These results indicate that different software implementations of a template-based modeling method similarly classify future knee osteoarthritis grades, motivating further evaluations using simpler cartilage constitutive models and additional studies on the reproducibility of these modeling strategies.


Asunto(s)
Cartílago Articular , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/diagnóstico , Reproducibilidad de los Resultados , Articulación de la Rodilla , Fenómenos Biomecánicos , Imagen por Resonancia Magnética/métodos
14.
J Mech Behav Biomed Mater ; 143: 105941, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37285774

RESUMEN

Fluid pressure develops transiently within mechanically-loaded, cell-embedding hydrogels, but its magnitude depends on the intrinsic material properties of the hydrogel and cannot be easily altered. The recently developed melt-electrowriting (MEW) technique enables three-dimensional printing of structured fibrous mesh with small fibre diameter (20 µm). The MEW mesh with 20 µm fibre diameter can synergistically increase the instantaneous mechanical stiffness of soft hydrogels. However, the reinforcing mechanism of the MEW meshes is not well understood, and may involve load-induced fluid pressurisation. Here, we examined the reinforcing effect of MEW meshes in three hydrogels: gelatin methacryloyl (GelMA), agarose and alginate, and the role of load-induced fluid pressurisation in the MEW reinforcement. We tested the hydrogels with and without MEW mesh (i.e., hydrogel alone, and MEW-hydrogel composite) using micro-indentation and unconfined compression, and analysed the mechanical data using biphasic Hertz and mixture models. We found that the MEW mesh altered the tension-to-compression modulus ratio differently for hydrogels that are cross-linked differently, which led to a variable change to their load-induced fluid pressurisation. MEW meshes only enhanced the fluid pressurisation for GelMA, but not for agarose or alginate. We speculate that only covalently cross-linked hydrogels (GelMA) can effectively tense the MEW meshes, thereby enhancing the fluid pressure developed during compressive loading. In conclusion, load-induced fluid pressurisation in selected hydrogels was enhanced by MEW fibrous mesh, and may be controlled by MEW mesh of different designs in the future, thereby making fluid pressure a tunable cell growth stimulus for tissue engineering involving mechanical stimulation.


Asunto(s)
Hidrogeles , Andamios del Tejido , Sefarosa , Ingeniería de Tejidos/métodos , Gelatina , Alginatos , Impresión Tridimensional
15.
Ann Biomed Eng ; 51(10): 2245-2257, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37332006

RESUMEN

Osteoarthritis degenerates cartilage and impairs joint function. Early intervention opportunities are missed as current diagnostic methods are insensitive to early tissue degeneration. We investigated the capability of visible light-near-infrared spectroscopy (Vis-NIRS) to differentiate normal human cartilage from early osteoarthritic one. Vis-NIRS spectra, biomechanical properties and the state of osteoarthritis (OARSI grade) were quantified from osteochondral samples harvested from different anatomical sites of human cadaver knees. Two support vector machines (SVM) classifiers were developed based on the Vis-NIRS spectra and OARSI scores. The first classifier was designed to distinguish normal (OARSI: 0-1) from general osteoarthritic cartilage (OARSI: 2-5) to check the general suitability of the approach yielding an average accuracy of 75% (AUC = 0.77). Then, the second classifier was designed to distinguish normal from early osteoarthritic cartilage (OARSI: 2-3) yielding an average accuracy of 71% (AUC = 0.73). Important wavelength regions for differentiating normal from early osteoarthritic cartilage were related to collagen organization (wavelength region: 400-600 nm), collagen content (1000-1300 nm) and proteoglycan content (1600-1850 nm). The findings suggest that Vis-NIRS allows objective differentiation of normal and early osteoarthritic tissue, e.g., during arthroscopic repair surgeries.


Asunto(s)
Cartílago Articular , Osteoartritis , Humanos , Cartílago Articular/diagnóstico por imagen , Espectroscopía Infrarroja Corta , Articulación de la Rodilla/diagnóstico por imagen , Colágeno
16.
Ann Biomed Eng ; 51(11): 2479-2489, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37335376

RESUMEN

Joint loading may affect the development of osteoarthritis, but patient-specific load estimation requires cumbersome motion laboratory equipment. This reliance could be eliminated using artificial neural networks (ANNs) to predict loading from simple input predictors. We used subject-specific musculoskeletal simulations to estimate knee joint contact forces for 290 subjects during over 5000 stance phases of walking and then extracted compartmental and total joint loading maxima from the first and second peaks of the stance phase. We then trained ANN models to predict the loading maxima from predictors that can be measured without motion laboratory equipment (subject mass, height, age, gender, knee abduction-adduction angle, and walking speed). When compared to the target data, our trained models had NRMSEs (RMSEs normalized to the mean of the response variable) between 0.14 and 0.42 and Pearson correlation coefficients between 0.42 and 0.84. The loading maxima were predicted most accurately using the models trained with all predictors. We demonstrated that prediction of knee joint loading maxima may be possible without laboratory-measured motion capture data. This is a promising step in facilitating knee joint loading predictions in simple environments, such as a physician's appointment. In future, the rapid measurement and analysis setup could be utilized to guide patients in rehabilitation to slow development of joint disorders, such as osteoarthritis.


Asunto(s)
Marcha , Osteoartritis de la Rodilla , Humanos , Marcha/fisiología , Fenómenos Biomecánicos , Articulación de la Rodilla/fisiología , Caminata/fisiología , Redes Neurales de la Computación
17.
J Orthop Res ; 41(12): 2657-2666, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37203565

RESUMEN

The aim of this study is to assess whether articular cartilage changes in an equine model of post-traumatic osteoarthritis (PTOA), induced by surgical creation of standard (blunt) grooves, and very subtle sharp grooves, could be detected with ex vivo T1 relaxation time mapping utilizing three-dimensional (3D) readout sequence with zero echo time. Grooves were made on the articular surfaces of the middle carpal and radiocarpal joints of nine mature Shetland ponies and osteochondral samples were harvested at 39 weeks after being euthanized under respective ethical permissions. T1 relaxation times of the samples (n = 8 + 8 for experimental and n = 12 for contralateral controls) were measured with a variable flip angle 3D multiband-sweep imaging with Fourier transform sequence. Equilibrium and instantaneous Young's moduli and proteoglycan (PG) content from OD of Safranin-O-stained histological sections were measured and utilized as reference parameters for the T1 relaxation times. T1 relaxation time was significantly (p < 0.05) increased in both groove areas, particularly in the blunt grooves, compared with control samples, with the largest changes observed in the superficial half of the cartilage. T1 relaxation times correlated weakly (Rs ≈ 0.33) with equilibrium modulus and PG content (Rs ≈ 0.21). T1 relaxation time in the superficial articular cartilage is sensitive to changes induced by the blunt grooves but not to the much subtler sharp grooves, at the 39-week timepoint post-injury. These findings support that T1 relaxation time has potential in detection of mild PTOA, albeit the most subtle changes could not be detected.


Asunto(s)
Huesos del Carpo , Cartílago Articular , Osteoartritis , Caballos , Animales , Imagen por Resonancia Magnética/métodos , Cartílago Articular/patología , Osteoartritis/diagnóstico por imagen , Osteoartritis/etiología , Osteoartritis/patología , Articulación de la Muñeca , Proteoglicanos
18.
J Anat ; 243(2): 297-310, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37057314

RESUMEN

The human semitendinosus muscle is characterized by a tendinous inscription separating proximal and distal neuromuscular compartments. As each compartment is innervated by separate nerve branches, potential exists for independent operation and control of compartments. However, the morphology and function of each compartment have not been thoroughly examined in an adult human population. Further, the distal semitendinosus tendon is typically harvested for use in anterior cruciate ligament reconstruction surgery, which induces long-term morphological changes to the semitendinosus muscle-tendon unit. It remains unknown if muscle morphological alterations following anterior cruciate ligament reconstruction are uniform between proximal and distal semitendinosus compartments. Here, we performed magnetic resonance imaging on 10 individuals who had undergone anterior cruciate ligament reconstruction involving an ipsilateral distal semitendinosus tendon graft 14 ± 4 months prior, extracting morphological parameters of the whole semitendinosus muscle and each individual compartment from both the (non-injured) contralateral and surgical legs. In the contralateral leg, volume and length of the proximal compartment were smaller than the distal compartment. No between-compartment differences in volume or length were found for anterior cruciate ligament reconstructed legs, likely due to greater shortening of the distal compared to the proximal compartment after anterior cruciate ligament reconstruction. The maximal anatomical cross-sectional area of both compartments was substantially smaller on the anterior cruciate ligament reconstructed leg but did not differ between compartments on either leg. The absolute and relative between-leg differences in proximal compartment morphology on the anterior cruciate ligament reconstructed leg were strongly correlated with the corresponding between-leg differences in distal compartment morphological parameters. Specifically, greater between-leg morphological differences in one compartment were highly correlated with large between-leg differences in the other compartment, and vice versa for smaller differences. These relationships indicate that despite the heterogeneity in compartment length and volume, compartment atrophy is not independent or random. Further, the tendinous inscription endpoints were generally positioned at the same proximodistal level as the compartment maximal anatomical cross-sectional areas, providing a wide area over which the tendinous inscription could mechanically interact with compartments. Overall, results suggest the two human semitendinosus compartments are not mechanically independent.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Músculos Isquiosurales , Adulto , Humanos , Músculo Esquelético/anatomía & histología , Tendones , Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos
19.
Ann Biomed Eng ; 51(8): 1769-1780, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37005948

RESUMEN

The collagen network is the highly organized backbone of articular cartilage providing tissue tensile stiffness and restricting proteoglycan bleaching out of the tissue. Osteoarthritis (OA) diminishes proper collagen network adaptation. Our aim was to provide quantitative three-dimensional (3D) information of the cartilage collagen network adaptation in early osteoarthritis using high resolution micro-computed tomography (µCT)-imaging. Osteochondral samples from the femoral condyles were collected from healthy (N = 8, both legs) and experimental OA rabbit model with anterior cruciate ligament transection (N = 14, single leg). Samples were processed for cartilage µCT-imaging and histological evaluation with polarized light microscopy (PLM). Structure tensor analysis was used to analyse the collagen fibre orientation and anisotropy of the µCT-images, and PLM was used as a validation for structural changes. Depth-wise comparison of collagen fibre orientation acquired with µCT-imaging and PLM correlated well, but the values obtained with PLM were systematically greater than those measured with µCT-imaging. Structure tensor analysis allowed for 3D quantification of collagen network anisotropy. Finally, µCT-imaging revealed only minor differences between the control and experimental groups.


Asunto(s)
Cartílago Articular , Osteoartritis , Animales , Conejos , Cartílago Articular/patología , Microtomografía por Rayos X , Anisotropía , Colágeno/análisis , Osteoartritis/patología
20.
Adv Exp Med Biol ; 1402: 45-56, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37052845

RESUMEN

Injurious loading of the joint can be accompanied by articular cartilage damage and trigger inflammation. However, it is not well-known which mechanism controls further cartilage degradation, ultimately leading to post-traumatic osteoarthritis. For personalized prognostics, there should also be a method that can predict tissue alterations following joint and cartilage injury. This chapter gives an overview of experimental and computational methods to characterize and predict cartilage degradation following joint injury. Two mechanisms for cartilage degradation are proposed. In (1) biomechanically driven cartilage degradation, it is assumed that excessive levels of strain or stress of the fibrillar or non-fibrillar matrix lead to proteoglycan loss or collagen damage and degradation. In (2) biochemically driven cartilage degradation, it is assumed that diffusion of inflammatory cytokines leads to degradation of the extracellular matrix. When implementing these two mechanisms in a computational in silico modeling workflow, supplemented by in vitro and in vivo experiments, it is shown that biomechanically driven cartilage degradation is concentrated on the damage environment, while inflammation via synovial fluid affects all free cartilage surfaces. It is also proposed how the presented in silico modeling methodology may be used in the future for personalized prognostics and treatment planning of patients with a joint injury.


Asunto(s)
Cartílago Articular , Artropatías , Osteoartritis , Humanos , Cartílago Articular/lesiones , Osteoartritis/metabolismo , Inflamación/metabolismo , Simulación por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...