Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 18(8): e0290347, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37624860

RESUMEN

Antimicrobial blue light (aBL) is an attractive option for managing biofilm burden at the skin-implant interface of percutaneous osseointegrated (OI) implants. However, marketed aBL devices have both structural and optical limitations that prevent them from being used in an OI implant environment. They must be handheld, preventing even irradiation of the entire skin-implant interface, and the devices do not offer sufficient optical power outputs required to kill biofilms. We present the developmental process of a unique aBL device that overcomes these limitations. Four prototypes are detailed, each being a progressive improvement from the previous iteration as we move from proof-of-concept to in vivo application. Design features focused on a cooling system, LED orientation, modularity, and "sheep-proofing". The final prototype was tested in an in vivo OI implant sheep model, demonstrating that it was structurally and optically adequate to address biofilm burdens at the skin-implant of percutaneous OI implants. The device made it possible to test aBL in the unique OI implant environment and compare its efficacy to clinical antibiotics-data which had not before been achievable. It has provided insight into whether or not continued pursual of light therapy research for OI implants, and other percutaneous devices, is worthwhile. However, the device has drawbacks concerning the cooling system, complexity, and size if it is to be translated to human clinical trials. Overall, we successfully developed a device to test aBL therapy for patients with OI implants and helped progress understanding in the field of infection management strategies.


Asunto(s)
Antiinfecciosos , Prótesis Anclada al Hueso , Humanos , Animales , Ovinos , Prótesis e Implantes , Luz , Antibacterianos/farmacología , Antibacterianos/uso terapéutico
2.
J Photochem Photobiol B ; 244: 112720, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37186990

RESUMEN

Cutaneous bacterial wound infections typically involve gram-positive cocci such as Staphylococcus aureus (SA) and usually become biofilm infections. Bacteria in biofilms may be 100-1000-fold more resistant to an antibiotic than the clinical laboratory minimal inhibitory concentration (MIC) for that antibiotic, contributing to antimicrobial resistance (AMR). AMR is a growing global threat to humanity. One pathogen-antibiotic resistant combination, methicillin-resistant SA (MRSA) caused more deaths globally than any other such combination in a recent worldwide statistical review. Many wound infections are accessible to light. Antimicrobial phototherapy, and particularly antimicrobial blue light therapy (aBL) is an innovative non-antibiotic approach often overlooked as a possible alternative or adjunctive therapy to reduce antibiotic use. We therefore focused on aBL treatment of biofilm infections, especially MRSA, focusing on in vitro and ex vivo porcine skin models of bacterial biofilm infections. Since aBL is microbicidal through the generation of reactive oxygen species (ROS), we hypothesized that menadione (Vitamin K3), a multifunctional ROS generator, might enhance aBL. Our studies suggest that menadione can synergize with aBL to increase both ROS and microbicidal effects, acting as a photosensitizer as well as an ROS recycler in the treatment of biofilm infections. Vitamin K3/menadione has been given orally and intravenously worldwide to thousands of patients. We conclude that menadione/Vitamin K3 can be used as an adjunct to antimicrobial blue light therapy, increasing the effectiveness of this modality in the treatment of biofilm infections, thereby presenting a potential alternative to antibiotic therapy, to which biofilm infections are so resistant.


Asunto(s)
Antiinfecciosos , Staphylococcus aureus Resistente a Meticilina , Infecciones Estafilocócicas , Infección de Heridas , Humanos , Vitamina K 3/farmacología , Vitamina K 3/uso terapéutico , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Especies Reactivas de Oxígeno/farmacología , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Antiinfecciosos/farmacología , Biopelículas , Infecciones Estafilocócicas/tratamiento farmacológico , Pruebas de Sensibilidad Microbiana
3.
Lasers Surg Med ; 55(4): 390-404, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36883985

RESUMEN

BACKGROUND: Extracorporeal membrane oxygenators (ECMO) are currently utilized to mechanically ventilate blood when lung or lung and heart function are impaired, like in cases of acute respiratory distress syndrome (ARDS). ARDS can be caused by severe cases of carbon monoxide (CO) inhalation, which is the leading cause of poison-related deaths in the United States. ECMOs can be further optimized for severe CO inhalation using visible light to photo-dissociate CO from hemoglobin (Hb). In previous studies, we combined phototherapy with an ECMO to design a photo-ECMO device, which significantly increased CO elimination and improved survival in CO-poisoned animal models using light at 460, 523, and 620 nm wavelengths. Light at 620 nm was the most effective in removing CO. OBJECTIVE: The aim of this study is to analyze the light propagation at 460, 523, and 620 nm wavelengths and the 3D blood flow and heating distribution within the photo-ECMO device that increased CO elimination in CO-poisoned animal models. METHODS: Light propagation, blood flow dynamics, and heat diffusion were modeled using the Monte Carlo method and the laminar Navier-Stokes and heat diffusion equations, respectively. RESULTS: Light at 620 nm propagated through the device blood compartment (4 mm), while light at 460 and 523 nm only penetrated 48% to 50% (~2 mm). The blood flow velocity in the blood compartment varied with regions of high (5 mm/s) and low (1 mm/s) velocity, including stagnant flow. The blood temperatures at the device outlet for 460, 523, and 620 nm wavelengths were approximately 26.7°C, 27.4°C, and 20°C, respectively. However, the maximum temperatures within the blood treatment compartment rose to approximately 71°C, 77°C, and 21°C, respectively. CONCLUSIONS: As the extent of light propagation correlates with efficiency in photodissociation, the light at 620 nm is the optimal wavelength for removing CO from Hb while maintaining blood temperatures below thermal damage. Measuring the inlet and outlet blood temperatures is not enough to avoid unintentional thermal damage by light irradiation. Computational models can help eliminate risks of excessive heating and improve device development by analyzing design modifications that improve blood flow, like suppressing stagnant flow, further increasing the rate of CO elimination.


Asunto(s)
Intoxicación por Monóxido de Carbono , Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Animales , Intoxicación por Monóxido de Carbono/terapia , Oxigenadores de Membrana , Oxigenación por Membrana Extracorpórea/métodos , Fototerapia/métodos , Síndrome de Dificultad Respiratoria/terapia
4.
Lasers Surg Med ; 54(2): 256-267, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34350599

RESUMEN

BACKGROUND AND OBJECTIVES: Carbon monoxide (CO) inhalation is the leading cause of poison-related deaths in the United States. CO binds to hemoglobin (Hb), displaces oxygen, and reduces oxygen delivery to tissues. The optimal treatment for CO poisoning in patients with normal lung function is the administration of hyperbaric oxygen (HBO). However, hyperbaric chambers are only available in medical centers with specialized equipment, resulting in delayed therapy. Visible light dissociates CO from Hb with minimal effect on oxygen binding. In a previous study, we combined a membrane oxygenator with phototherapy at 623 nm to produce a "mini" photo-ECMO (extracorporeal membrane oxygenation) device, which improved CO elimination and survival in CO-poisoned rats. The objective of this study was to develop a larger photo-ECMO device ("maxi" photo-ECMO) and to test its ability to remove CO from a porcine model of CO poisoning. STUDY DESIGN/MATERIALS AND METHODS: The "maxi" photo-ECMO device and the photo-ECMO system (six maxi photo-ECMO devices assembled in parallel), were tested in an in vitro circuit of CO poisoning. To assess the ability of the photo-ECMO device and the photo-ECMO system to remove CO from CO-poisoned blood in vitro, the half-life of COHb (COHb-t1/2 ), as well as the percent COHb reduction in a single blood pass through the device, were assessed. In the in vivo studies, we assessed the COHb-t1/2 in a CO-poisoned pig under three conditions: (1) While the pig breathed 100% oxygen through the endotracheal tube; (2) while the pig was connected to the photo-ECMO system with no light exposure; and (3) while the pig was connected to the photo-ECMO system, which was exposed to red light. RESULTS: The photo-ECMO device was able to fully oxygenate the blood after a single pass through the device. Compared to ventilation with 100% oxygen alone, illumination with red light together with 100% oxygen was twice as efficient in removing CO from blood. Changes in gas flow rates did not alter CO elimination in one pass through the device. Increases in irradiance up to 214 mW/cm2 were associated with an increased rate of CO elimination. The photo-ECMO device was effective over a range of blood flow rates and with higher blood flow rates, more CO was eliminated. A photo-ECMO system composed of six photo-ECMO devices removed CO faster from CO-poisoned blood than a single photo-ECMO device. In a CO-poisoned pig, the photo-ECMO system increased the rate of CO elimination without significantly increasing the animal's body temperature or causing hemodynamic instability. CONCLUSION: In this study, we developed a photo-ECMO system and demonstrated its ability to remove CO from CO-poisoned 45-kg pigs. Technical modifications of the photo-ECMO system, including the development of a compact, portable device, will permit treatment of patients with CO poisoning at the scene of their poisoning, during transit to a local emergency room, and in hospitals that lack HBO facilities.


Asunto(s)
Intoxicación por Monóxido de Carbono , Venenos , Animales , Monóxido de Carbono , Intoxicación por Monóxido de Carbono/terapia , Carboxihemoglobina/metabolismo , Humanos , Fototerapia/métodos , Ratas , Porcinos
5.
J Biomed Sci Eng ; 10(11): 550-561, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30405872

RESUMEN

This study presents the development of an innovative artificial finger-like device that provides position specific mechanical loads at the end of the long bone and induces mechanotransduction in bone. Bone cells such as osteoblasts are the mechanosensitive cells that regulate bone remodelling. When they receive gentle, periodic mechanical loads, new bone formation is promoted. The proposed device is an under-actuated multi-fingered artificial hand with 4 fingers, each having two phalanges. These fingers are connected by mechanical linkages and operated by a worm gearing mechanism. With the help of 3D printing technology, a prototype device was built mostly using plastic materials. The experimental validation results show that the device is capable of generating necessary forces at the desired frequencies, which are suitable for the stimulation of bone cells and the promotion of bone formation. It is recommended that the device be tested in a clinical study for confirming its safety and efficacy with patients.