Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Heliyon ; 4(4): e00606, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29862367

RESUMEN

BACKGROUND: Molecular MRI is becoming increasingly important for preclinical research. Validation of targeted gadolinium probes in tissue however has been cumbersome up to now. Novel methodology to assess gadolinium distribution in tissue after in vivo application is therefore needed. PURPOSE: To establish combined Magnetic Resonance Imaging (MRI) and Mass Spectrometry Imaging (MSI) for improved detection and quantification of Gadofluorine P deposition in scar formation and myocardial remodeling. MATERIALS AND METHODS: Animal studies were performed according to institutionally approved protocols. Myocardial infarction was induced by permanent ligation of the left ascending artery (LAD) in C57BL/6J mice. MRI was performed at 7T at 1 week and 6 weeks after myocardial infarction. Gadofluorine P was used for dynamic T1 mapping of extracellular matrix synthesis during myocardial healing and compared to Gd-DTPA. After in vivo imaging contrast agent concentration as well as distribution in tissue were validated and quantified by spatially resolved Matrix-Assisted Laser Desorption Ionization (MALDI) MSI and Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry (LA-ICP-MS) imaging. RESULTS: Both Gadofluorine P enhancement as well as local tissue content in the myocardial scar were highest at 15 minutes post injection. R1 values increased from 1 to 6 weeks after MI (1.62 s-1 vs 2.68 s-1, p = 0.059) paralleled by an increase in Gadofluorine P concentration in the infarct from 0.019 mM at 1 week to 0.028 mM at 6 weeks (p = 0.048), whereas Gd-DTPA enhancement showed no differences (3.95 s-1 vs 3.47 s-1, p = 0.701). MALDI-MSI results were corroborated by elemental LA-ICP-MS of Gadolinium in healthy and infarcted myocardium. Histology confirmed increased extracellular matrix synthesis at 6 weeks compared to 1 week. CONCLUSION: Adding quantitative MSI to MR imaging enables a quantitative validation of Gadofluorine P distribution in the heart after MI for molecular imaging.

2.
Theranostics ; 7(18): 4470-4479, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29158839

RESUMEN

Extraction of murine cardiac functional parameters on a beat-by-beat basis is limited with the existing imaging modalities due to insufficient three-dimensional temporal resolution. Faster volumetric imaging methods enabling in vivo characterization of functional parameters are poised to advance cardiovascular research and provide a better understanding of the mechanisms underlying cardiac diseases. We present a new approach based on analyzing contrast-enhanced optoacoustic (OA) images acquired at high volumetric frame rate without using cardiac gating or other approaches for motion correction. We apply an acute murine myocardial infarction model optimized for acquisition of artifact-free optoacoustic imaging data to study cardiovascular hemodynamics. Infarcted hearts (n = 21) could be clearly differentiated from healthy controls (n = 9) based on a significantly higher pulmonary transit time (PTT) (2.25 [2.00-2.41] s versus 1.34 [1.25-1.67] s, p = 0.0235), while no statistically significant difference was observed in the heart rate (318 [252-361] bpm versus 264 [252-320] bpm, p = 0.3129). Nevertheless, nonlinear heartbeat dynamics was stronger in the healthy hearts, as evidenced by the third harmonic component in the heartbeat spectra. MRI data acquired from the same mice further revealed that the PTT increases with the size of infarction and similarly increases with reduced ejection fraction. Moreover, an inverse relationship between infarct PTT and time post-surgery was found, which suggests the occurrence of cardiac healing. In combination with the proven ability of optoacoustics to track targeted probes within the injured myocardium, our method can depict cardiac anatomy, function, and molecular signatures, with both high spatial and temporal resolution. Volumetric four-dimensional optoacoustic characterization of cardiac dynamics with supreme temporal resolution can capture cardiovascular dynamics on a beat-by-beat basis in mouse models of myocardial ischemia.


Asunto(s)
Corazón/fisiopatología , Infarto del Miocardio/patología , Miocardio/patología , Animales , Medios de Contraste/metabolismo , Frecuencia Cardíaca/fisiología , Imagen por Resonancia Magnética/métodos , Ratones , Ratones Endogámicos C57BL
3.
Arterioscler Thromb Vasc Biol ; 37(3): 525-533, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28062502

RESUMEN

OBJECTIVE: Neutrophils accumulate in early atherosclerotic lesions and promote lesion growth. In this study, we evaluated an elastase-specific near-infrared imaging agent for molecular imaging using hybrid fluorescence molecular tomography/x-ray computed tomography. APPROACH AND RESULTS: Murine neutrophils were isolated from bone marrow and incubated with the neutrophil-targeted near-infrared imaging agent Neutrophil Elastase 680 FAST for proof of principle experiments, verifying that the elastase-targeted fluorescent agent is specifically cleaved and activated by neutrophil content after lysis or cell stimulation. For in vivo experiments, low-density lipoprotein receptor-deficient mice were placed on a Western-type diet and imaged after 4, 8, and 12 weeks by fluorescence molecular tomography/x-ray computed tomography. Although this agent remains silent on injection, it produces fluorescent signal after cleavage by neutrophil elastase. After hybrid fluorescence molecular tomography/x-ray computed tomography imaging, mice were euthanized for whole-body cryosectioning and histological analyses. The in vivo fluorescent signal in the area of the aortic arch was highest after 4 weeks of high-fat diet feeding and decreased at 8 and 12 weeks. Ex vivo whole-body cryoslicing confirmed the fluorescent signal to locate to the aortic arch and to originate from the atherosclerotic arterial wall. Histological analysis demonstrated the presence of neutrophils in atherosclerotic lesions. CONCLUSIONS: This study provides evidence that elastase-targeted imaging can be used for in vivo detection of early atherosclerosis. This imaging approach may harbor potential in the clinical setting for earlier diagnosis and treatment of atherosclerosis.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Aterosclerosis/diagnóstico por imagen , Elastasa de Leucocito/metabolismo , Imagen Molecular/métodos , Imagen Multimodal/métodos , Neutrófilos/enzimología , Imagen Óptica , Tomografía Computarizada por Rayos X , Animales , Aorta Torácica/enzimología , Aorta Torácica/patología , Enfermedades de la Aorta/enzimología , Enfermedades de la Aorta/genética , Enfermedades de la Aorta/patología , Apolipoproteínas E/deficiencia , Apolipoproteínas E/genética , Aterosclerosis/enzimología , Aterosclerosis/genética , Aterosclerosis/patología , Biomarcadores/metabolismo , Células Cultivadas , Dieta Occidental , Modelos Animales de Enfermedad , Diagnóstico Precoz , Colorantes Fluorescentes/administración & dosificación , Predisposición Genética a la Enfermedad , Ratones Noqueados , Neutrófilos/patología , Fenotipo , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Receptores de LDL/deficiencia , Receptores de LDL/genética , Factores de Tiempo
4.
Neoplasia ; 19(1): 8-16, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27940248

RESUMEN

Integrins play an important role in tumor progression, invasion and metastasis. Therefore we aimed to evaluate a preclinical imaging approach applying ανß3 integrin targeted hybrid Fluorescence Molecular Tomography/X-ray Computed Tomography (FMT-XCT) for monitoring tumor progression as well as early therapy response in a syngeneic murine Non-Small Cell Lung Cancer (NSCLC) model. Lewis Lung Carcinomas were grown orthotopically in C57BL/6 J mice and imaged in-vivo using a ανß3 targeted near-infrared fluorescence (NIRF) probe. ανß3-targeted FMT-XCT was able to track tumor progression. Cilengitide was able to substantially block the binding of the NIRF probe and suppress the imaging signal. Additionally mice were treated with an established chemotherapy regimen of Cisplatin and Bevacizumab or with a novel MEK inhibitor (Refametinib) for 2 weeks. While µCT revealed only a moderate slowdown of tumor growth, ανß3 dependent signal decreased significantly compared to non-treated mice already at one week post treatment. ανß3 targeted imaging might therefore become a promising tool for assessment of early therapy response in the future.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Fluorescencia , Integrinas/metabolismo , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/metabolismo , Tomografía Computarizada por Rayos X , Tomografía , Animales , Antineoplásicos/farmacología , Carcinoma Pulmonar de Lewis/diagnóstico , Carcinoma Pulmonar de Lewis/tratamiento farmacológico , Carcinoma Pulmonar de Lewis/genética , Carcinoma Pulmonar de Lewis/metabolismo , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/genética , Línea Celular Tumoral , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Expresión Génica , Humanos , Integrina alfaVbeta3/genética , Integrina alfaVbeta3/metabolismo , Integrinas/genética , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Imagen Molecular , Inhibidores de Proteínas Quinasas/farmacología , Resultado del Tratamiento , Ensayos Antitumor por Modelo de Xenoinjerto
5.
Angew Chem Int Ed Engl ; 54(14): 4279-83, 2015 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-25689595

RESUMEN

Gadolinium(III)-based contrast agents improve the sensitivity and specificity of magnetic resonance imaging (MRI), especially when targeted contrast agents are applied. Because of nonlinear correlation between the contrast agent concentration in tissue and the MRI signal obtained in vivo, quantification of certain biological or pathophysiological processes by MRI remains a challenge. Up to now, no technology has been able to provide a spatially resolved quantification of MRI agents directly within the tissue, which would allow a more precise verification of in vivo imaging results. MALDI imaging mass spectrometry for spatially resolved in situ quantification of gadolinium(III) agents, in correlation to in vivo MRI, were evaluated. Enhanced kinetics of Gadofluorine M were determined dynamically over time in a mouse model of myocardial infarction. MALDI imaging was able to corroborate the in vivo imaging MRI signals and enabled in situ quantification of the gadolinium probe with high spatial resolution.


Asunto(s)
Medios de Contraste , Gadolinio/química , Imagen por Resonancia Magnética/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
6.
Circ Cardiovasc Imaging ; 7(2): 321-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24363356

RESUMEN

BACKGROUND: To prospectively evaluate an elastin-specific MR contrast agent (ESMA) for in vivo targeting of elastic fibers in myocardial infarction (MI) and postinfarction scar remodeling. METHODS AND RESULTS: MI was induced in C57BL/6J mice (n=40) by permanent ligation of the left anterior descending coronary artery. MRI was performed at 7 and 21 days after MI. The merits of gadolinium-based ESMA (Gd-ESMA) were compared with gadopentetic acid (Gd-DTPA) for infarct size determination, contrast-to-noise ratio (CNR), and enhancement kinetics. Specific binding in vivo was evaluated by blocking the molecular target using nonparamagnetic lanthanum-ESMA. In vivo imaging results were confirmed by postmortem triphenyltetrazolium chloride staining, elastica van Gieson staining, and Western blotting. Delayed enhancement MRI revealed prolonged enhancement of Gd-ESMA in the postischemic scar compared with Gd-DTPA. Infarct size measurements showed good agreement between Gd-ESMA and Gd-DTPA and were confirmed by ex vivo triphenyltetrazolium chloride staining. Preinjection of the blocking lanthanum-ESMA resulted in significantly lower CNR of Gd-ESMA at the infarct site (P=0.0019). Although no significant differences in CNR were observed between delayed enhancement imaging and Gd-DTPA between days 7 and 21 (1.8± versus 3.8; P=ns), Gd-ESMA showed markedly higher CNR on day 21 after MI (14.1 versus 4.9; P=0.0032), which correlated with increased synthesis of tropoelastin detected by Western blot analysis and histology. Higher CNR values for Gd-ESMA further correlated with improved ejection fraction of the mice on day 21 after MI. CONCLUSIONS: Gd-ESMA enables targeting of elastin within the infarct scar in a mouse model of MI. The imaging properties of Gd-ESMA allow quantification of intrascar elastin content in vivo and thereby provide potential for noninvasive characterization of postinfarction scar remodeling.


Asunto(s)
Cicatriz/diagnóstico , Vasos Coronarios/patología , Tejido Elástico/patología , Gadolinio DTPA , Imagen por Resonancia Cinemagnética/métodos , Infarto del Miocardio/diagnóstico , Miocardio/patología , Animales , Cicatriz/etiología , Medios de Contraste , Modelos Animales de Enfermedad , Elastina , Femenino , Estudios de Seguimiento , Ratones , Ratones Endogámicos C57BL , Infarto del Miocardio/complicaciones , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo
7.
Theranostics ; 3(11): 903-13, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24312159

RESUMEN

Cardiomyocyte loss via apoptosis plays a crucial role in ventricular remodeling following myocardial infarction (MI). Cell-based therapy approaches using bone marrow derived c-kit⁺ pluripotent cells may attenuate apoptosis following ischemic injury. We therefore thought to examine the early course of apoptosis following myocardial infarction - in-vivo - and non-invasively determine the effect of c-kit⁺ bone marrow cells on post-MI remodeling. We studied apoptosis in wild-type Kit(+/+) , c-kit mutant Kit(W)/Kit(W-v) and Kit(W)/Kit(W-v) mice after cell therapy with bone-marrow derived c-kit⁺ cells after ischemia-reperfusion injury. Mice were followed by hybrid Fluorescence Molecular Tomography/X-ray Computed Tomography (FMT-XCT) at 6h, 24h and 7 days after ischemia-reperfusion injury using an Annexin V-based fluorescent nanosensor targeting phosphatidylserine. Kit(W)/Kit(W-v) mice showed increased and prolonged apoptosis compared to control Kit(+/+) mice while c-kit cell therapy was able to attenuate the altered apoptosis rates. Increased apoptosis was accompanied by severe decline in heart function, determined by cardiac Magnetic Resonance Imaging, and cell therapy was able to rescue the animals from deleterious heart failure. Post-mortem cryoslicing and immunohistochemistry localized the fluorescence signal of the Annexin V sensor within the infarcted myocardium. Flow cytometry of digested infarct specimens identified apoptotic cardiomyocytes as the major source for the in-vivo Annexin V signal. In-vivo molecular imaging using hybrid FMT-XCT reveals increased cardiomyocyte apoptosis in Kit(W)/Kit(W-v) mice and shows that c-kit⁺ cardioprotective cells are able to attenuate post-MI apoptosis and rescue mice from progressive heart failure.


Asunto(s)
Apoptosis , Células de la Médula Ósea/fisiología , Tratamiento Basado en Trasplante de Células y Tejidos/métodos , Infarto del Miocardio/terapia , Daño por Reperfusión Miocárdica/terapia , Células Madre Pluripotentes/fisiología , Proteínas Proto-Oncogénicas c-kit/análisis , Animales , Células de la Médula Ósea/química , Imagen por Resonancia Magnética , Ratones , Imagen Molecular , Infarto del Miocardio/patología , Daño por Reperfusión Miocárdica/patología , Imagen Óptica , Células Madre Pluripotentes/química , Tomografía Computarizada por Rayos X
8.
Photoacoustics ; 1(1): 3-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25327410

RESUMEN

OBJECTIVES: To investigate the feasibility of a high resolution optical imaging strategy for myocardial infarction. BACKGROUND: Near-infrared approaches to imaging cardiovascular disease enable visualization of disease-associated biological processes in vivo. However, even at the scale of small animals, the strong scattering of light prevents high resolution imaging after the first 1-2 mm of tissue, leading to degraded signal localization. METHODS: Multispectral optoacoustic tomography (MSOT) was used to non-invasively image myocardial infarction (MI) in a murine model of coronary artery ligation at resolutions not possible with current deep-tissue optical imaging methods. Post-MI imaging was based on resolving the spectral absorption signature of a dendritic polyglycerol sulfate-based (dPGS) near-infrared imaging agent targeted to P- and L-selectin. RESULTS: In vivo imaging succeeded in detection of the agent in the injured myocardium after intravenous injection. The high anatomic resolution (<200 µm) achieved by the described method allowed signals originating in the infarcted heart to be distinguished from uptake in adjacent regions. Histological analysis found dPGS signal in infarcted areas, originating from leukocytes and endothelial cells. CONCLUSIONS: MSOT imaging of myocardial infarction provides non-invasive visualization of optical contrast with a high spatial resolution that is not degraded by the scattering of light.

9.
J Magn Reson Imaging ; 36(6): 1372-82, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22972713

RESUMEN

PURPOSE: To evaluate phase-sensitive inversion-recovery (PSIR) imaging at 1.5 T in a mouse model of permanent coronary artery ligation as a potentially rapid and robust alternative for the accurate assessment of myocardial infarction (MI) by cardiac magnetic resonance imaging (MRI). MATERIALS AND METHODS: PSIR late gadolinium enhancement (LGE) imaging was compared to conventional 2D segmented inversion-recovery imaging for the assessment of murine MI. RESULTS: PSIR images provided comparable contrast and kinetics of intravenously injected gadopentetate dimeglumine (Gd-DTPA). At the mid-ventricular level there was good agreement between conventional IR and PSIR for infarct size assessment. After intravenous injection a limited time window of ∼6 minutes is available for delayed enhancement imaging in mice. Whole-heart infarct imaging with 1 mm thick slices was only possible in this restricted time frame when the PSIR method is applied, avoiding the need for repetitively adapting the correct inversion time. Infarct size determined by PSIR MRI demonstrated good agreement with postmortem histology. Infarct size determined by PSIR LGE MRI inversely correlates with left-ventricular function on day 7 after MI. CONCLUSION: The PSIR technique provides stable and consistent contrast between hyperenhanced and remote myocardium independent of the selected inversion time (TI) and proved to be a robust, fast, and accurate tool for the assessment of MI in mice.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Infarto del Miocardio/patología , Animales , Femenino , Ratones , Ratones Endogámicos C57BL , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
PLoS One ; 6(10): e25197, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21984904

RESUMEN

OBJECTIVE: To explore the capacity of human CD1⁺CD16⁺⁺ and CD14⁺⁺CD16⁻ monocytes to phagocyte iron-oxide nanoparticles in vitro. METHODS: Human monocytes were labeled with four different magnetic nanoparticle preparations (Ferumoxides, SHU 555C, CLIO-680, MION-48) exhibiting distinct properties and cellular uptake was quantitatively assessed by flow cytometry, fluorescence microscopy, atomic absorption spectrometry and Magnetic Resonance Imaging (MRI). Additionally we determined whether cellular uptake of the nanoparticles resulted in phenotypic changes of cell surface markers. RESULTS: Cellular uptake differed between the four nanoparticle preparations. However for each nanoparticle tested, CD14⁺⁺CD16⁻ monocytes displayed a significantly higher uptake compared to CD14⁺CD16⁺⁺ monocytes, this resulted in significantly lower T1 and T2 relaxation times of these cells. The uptake of iron-oxide nanoparticles further resulted in a remarkable shift of expression of cell surface proteins indicating that the labeling procedure affects the phenotype of CD14⁺CD16⁺⁺ and CD14⁺⁺CD16⁻ monocytes differently. CONCLUSION: Human monocyte subsets internalize different magnetic nanoparticle preparations differently, resulting in variable loading capacities, imaging phenotypes and likely biological properties.


Asunto(s)
Compuestos Férricos/metabolismo , Monocitos/citología , Monocitos/metabolismo , Nanopartículas/química , Fagocitosis , Adulto , Biomarcadores/metabolismo , Femenino , Citometría de Flujo , Humanos , Espacio Intracelular/metabolismo , Hierro/metabolismo , Espectroscopía de Resonancia Magnética , Masculino , Microscopía Fluorescente , Monocitos/clasificación , Fenotipo , Espectrofotometría Atómica , Coloración y Etiquetado
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...