Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
JAMA Intern Med ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38805196

RESUMEN

Importance: The consequences of low levels of environmental lead exposure, as found commonly in US household water, have not been established. Objective: To examine whether commonly encountered levels of lead in household water are associated with hematologic toxicity among individuals with advanced kidney disease, a group known to have disproportionate susceptibility to environmental toxicants. Design, Setting, and Participants: Cross-sectional analysis of household water lead concentrations and hematologic outcomes was performed among patients beginning dialysis at a Fresenius Medical Care outpatient facility between January 1, 2017, and December 20, 2021. Data analysis was performed from April 1 to August 15, 2023. Exposure: Concentrations of lead in household water were examined in categorical proportions of the Environmental Protection Agency's allowable threshold (15 µg/L) and continuously. Main Outcomes and Measures: Hematologic toxic effects were defined by monthly erythropoiesis-stimulating agent (ESA) dosing during the first 90 days of incident kidney failure care and examined as 3 primary outcomes: a proportion receiving maximum or higher dosing, continuously, and by a resistance index that normalized to body weight and hemoglobin concentrations. Secondarily, hemoglobin concentrations for patients with data prior to kidney failure onset were examined, overall and among those with concurrent iron deficiency, thought to increase gastrointestinal absorption of ingested lead. Results: Among 6404 patients with incident kidney failure (male, 4182 [65%]; mean [SD] age, 57 [14] years) followed up for the first 90 days of dialysis therapy, 12% (n = 742) had measurable lead in household drinking water. A higher category of household lead contamination was associated with 15% (odds ratio [OR], 1.15 [95% CI, 1.04-1.27]) higher risk of maximum monthly ESA dosing, 4.5 (95% CI, 0.8-8.2) µg higher monthly ESA dose, and a 0.48% (95% CI, 0.002%-0.96%) higher monthly resistance index. Among patients with pre-kidney failure hemoglobin measures (n = 2648), a higher household lead categorization was associated with a 0.12 (95% CI, -0.23 to -0.002) g/dL lower hemoglobin concentration, particularly among those with concurrent iron deficiency (multiplicative interaction, P = .07), among whom hemoglobin concentrations were 0.25 (95% CI, -0.47 to -0.04) g/dL lower. Conclusion: The findings of this study suggest that levels of lead found commonly in US drinking water may be associated with lead poisoning among susceptible individuals.

2.
Adv Kidney Dis Health ; 30(1): 33-39, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36723279

RESUMEN

A case study explores patterns of kidney function decline using unsupervised learning methods first and then associating patterns with clinical outcomes using supervised learning methods. Predicting short-term risk of hospitalization and death prior to renal dialysis initiation may help target high-risk patients for more aggressive management. This study combined clinical data from patients presenting for renal dialysis at Fresenius Medical Care with laboratory data from Quest Diagnostics to identify disease trajectory patterns associated with the 90-day risk of hospitalization and death after beginning renal dialysis. Patients were clustered into 4 groups with varying rates of estimated glomerular filtration rate (eGFR) decline during the 2-year period prior to dialysis. Overall rates of hospitalization and death were 24.9% (582/2341) and 4.6% (108/2341), respectively. Groups with the steepest declines had the highest rates of hospitalization and death within 90 days of dialysis initiation. The rate of eGFR decline is a valuable and readily available tool to stratify short-term (90 days) risk of hospitalization and death after the initiation of renal dialysis. More intense approaches are needed that apply models that identify high risks to potentially avert or reduce short-term hospitalization and death of patients with a severe and rapidly progressive chronic kidney disease.


Asunto(s)
Diálisis Renal , Insuficiencia Renal Crónica , Humanos , Diálisis Renal/efectos adversos , Insuficiencia Renal Crónica/diagnóstico , Tasa de Filtración Glomerular , Hospitalización , Riñón
3.
BMC Nephrol ; 23(1): 340, 2022 10 22.
Artículo en Inglés | MEDLINE | ID: mdl-36273142

RESUMEN

BACKGROUND: We developed machine learning models to understand the predictors of shorter-, intermediate-, and longer-term mortality among hemodialysis (HD) patients affected by COVID-19 in four countries in the Americas. METHODS: We used data from adult HD patients treated at regional institutions of a global provider in Latin America (LatAm) and North America who contracted COVID-19 in 2020 before SARS-CoV-2 vaccines were available. Using 93 commonly captured variables, we developed machine learning models that predicted the likelihood of death overall, as well as during 0-14, 15-30, > 30 days after COVID-19 presentation and identified the importance of predictors. XGBoost models were built in parallel using the same programming with a 60%:20%:20% random split for training, validation, & testing data for the datasets from LatAm (Argentina, Columbia, Ecuador) and North America (United States) countries. RESULTS: Among HD patients with COVID-19, 28.8% (1,001/3,473) died in LatAm and 20.5% (4,426/21,624) died in North America. Mortality occurred earlier in LatAm versus North America; 15.0% and 7.3% of patients died within 0-14 days, 7.9% and 4.6% of patients died within 15-30 days, and 5.9% and 8.6% of patients died > 30 days after COVID-19 presentation, respectively. Area under curve ranged from 0.73 to 0.83 across prediction models in both regions. Top predictors of death after COVID-19 consistently included older age, longer vintage, markers of poor nutrition and more inflammation in both regions at all timepoints. Unique patient attributes (higher BMI, male sex) were top predictors of mortality during 0-14 and 15-30 days after COVID-19, yet not mortality > 30 days after presentation. CONCLUSIONS: Findings showed distinct profiles of mortality in COVID-19 in LatAm and North America throughout 2020. Mortality rate was higher within 0-14 and 15-30 days after COVID-19 in LatAm, while mortality rate was higher in North America > 30 days after presentation. Nonetheless, a remarkable proportion of HD patients died > 30 days after COVID-19 presentation in both regions. We were able to develop a series of suitable prognostic prediction models and establish the top predictors of death in COVID-19 during shorter-, intermediate-, and longer-term follow up periods.


Asunto(s)
COVID-19 , Adulto , Humanos , Masculino , Vacunas contra la COVID-19 , Aprendizaje Automático , América del Norte/epidemiología , Diálisis Renal , SARS-CoV-2 , Femenino
5.
BMC Nephrol ; 22(1): 313, 2021 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-34530746

RESUMEN

BACKGROUND: SARS-CoV-2 can remain transiently viable on surfaces. We examined if use of shared chairs in outpatient hemodialysis associates with a risk for indirect patient-to-patient transmission of SARS-CoV-2. METHODS: We used data from adults treated at 2,600 hemodialysis facilities in United States between February 1st and June 8th, 2020. We performed a retrospective case-control study matching each SARS-CoV-2 positive patient (case) to a non-SARS-CoV-2 patient (control) treated in the same dialysis shift. Cases and controls were matched on age, sex, race, facility, shift date, and treatment count. For each case-control pair, we traced backward 14 days to assess possible prior exposure from a 'shedding' SARS-CoV-2 positive patient who sat in the same chair immediately before the case or control. Conditional logistic regression models tested whether chair exposure after a shedding SARS-CoV-2 positive patient conferred a higher risk of SARS-CoV-2 infection to the immediate subsequent patient. RESULTS: Among 170,234 hemodialysis patients, 4,782 (2.8 %) tested positive for SARS-CoV-2 (mean age 64 years, 44 % female). Most facilities (68.5 %) had 0 to 1 positive SARS-CoV-2 patient. We matched 2,379 SARS-CoV-2 positive cases to 2,379 non-SARS-CoV-2 controls; 1.30 % (95 %CI 0.90 %, 1.87 %) of cases and 1.39 % (95 %CI 0.97 %, 1.97 %) of controls were exposed to a chair previously sat in by a shedding SARS-CoV-2 patient. Transmission risk among cases was not significantly different from controls (OR = 0.94; 95 %CI 0.57 to 1.54; p = 0.80). Results remained consistent in adjusted and sensitivity analyses. CONCLUSIONS: The risk of indirect patient-to-patient transmission of SARS-CoV-2 infection from dialysis chairs appears to be low.


Asunto(s)
Instituciones de Atención Ambulatoria , COVID-19/transmisión , Fómites/virología , Diseño Interior y Mobiliario , Pacientes Ambulatorios , Diálisis Renal , Esparcimiento de Virus , Anciano , COVID-19/epidemiología , Estudios de Casos y Controles , Exposición a Riesgos Ambientales , Femenino , Humanos , Control de Infecciones/métodos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Estudios Retrospectivos , Riesgo , SARS-CoV-2 , Estados Unidos/epidemiología
7.
Blood Purif ; 50(6): 959-967, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33789265

RESUMEN

BACKGROUND: By inhibiting the adsorption of protein and platelets, surface-modifying macromolecules (SMMs) may improve the hemocompatibility of hemodialyzers. This trial aims to assess the performance and safety of a novel dialyzer with a fluorinated polyurethane SMM, Endexo™. METHODS: This prospective, sequential, multicenter, open-label study (NCT03536663) was designed to meet regulatory requirements for clinical testing of new hemodialyzers, including assessment of the in vivo ultrafiltration coefficient (Kuf). Adults prescribed thrice-weekly hemodialysis were eligible for enrollment. After completing 12 hemodialysis sessions with an Optiflux® F160NR dialyzer, patients received 38 sessions with the dialyzer with Endexo. Evaluated parameters included the in vivo Kuf of the dialyzer with Endexo extent of removal of urea, albumin, and ß2-microglobulin (ß2M), as well as complement activation. RESULTS: Twenty-three patients received 268 hemodialysis treatments during the Optiflux period, and 18 patients received 664 hemodialysis treatments during the Endexo period. Three serious adverse events were reported, and none of them were considered device related. No overt complement activation was observed with either dialyzer. Both dialyzers were associated with comparable mean increases in serum albumin levels from pre- to posthemodialysis (Optiflux: 7.9%; Endexo: 8.0%). These increases can be viewed in the context of a mean increase in hemoglobin of approximately 5% and a mean ultrafiltration volume removed of approximately 2.2 L. The corrected mean ß2M removal rate was 47% higher during the Endexo period (67.73%). Mean treatment times (208 vs. 205 min), blood flow rates (447.7 vs. 447.5 mL/min), dialysate flow rates (698.5 vs. 698.0 mL/min), urea reduction ratio (82 vs. 81%), and spKt/V (2.1 vs. 1.9) were comparable for the Endexo and Optiflux periods, respectively. The mean (SD) Kuf was 15.85 (10.33) mL/h/mm Hg during the first use of the dialyzer with Endexo (primary endpoint) and 16.36 (9.92) mL/h/mm Hg across the Endexo period. CONCLUSIONS: The safety of the novel dialyzer with Endexo was generally comparable to the Optiflux dialyzer, while exhibiting a higher ß2M removal rate.


Asunto(s)
Materiales Biocompatibles/química , Fallo Renal Crónico/terapia , Poliuretanos/química , Diálisis Renal/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles/efectos adversos , Femenino , Halogenación , Humanos , Fallo Renal Crónico/sangre , Masculino , Membranas Artificiales , Persona de Mediana Edad , Poliuretanos/efectos adversos , Estudios Prospectivos , Diálisis Renal/efectos adversos , Albúmina Sérica/análisis , Albúmina Sérica/aislamiento & purificación , Urea/sangre , Urea/aislamiento & purificación , Microglobulina beta-2/sangre , Microglobulina beta-2/aislamiento & purificación
8.
medRxiv ; 2021 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-33655270

RESUMEN

BACKGROUND: SARS-CoV-2 is primarily transmitted through aerosolized droplets; however, the virus can remain transiently viable on surfaces. OBJECTIVE: We examined transmission within hemodialysis facilities, with a specific focus on the possibility of indirect patient-to-patient transmission through shared dialysis chairs. DESIGN: We used real-world data from hemodialysis patients treated between February 1 st and June 8 th , 2020 to perform a case-control study matching each SARS-CoV-2 positive patient (case) to a non-SARS-CoV-2 patient (control) in the same dialysis shift and traced back 14 days to capture possible exposure from chairs sat in by SARS-CoV-2 patients. Cases and controls were matched on age, sex, race, facility, shift date, and treatment count. SETTING: 2,600 hemodialysis facilities in the United States. PATIENTS: Adult (age ≥18 years) hemodialysis patients. MEASUREMENTS: Conditional logistic regression models tested whether chair exposure after a positive patient conferred a higher risk of SARS-CoV-2 infection to the immediate subsequent patient. RESULTS: Among 170,234 hemodialysis patients, 4,782 (2.8%) tested positive for SARS-CoV-2 (mean age 64 years, 44% female). Most facilities (68.5%) had 0 to 1 positive SARS-CoV-2 patient. We matched 2,379 SARS-CoV-2 positive cases to 2,379 non-SARS-CoV-2 controls; 1.30% (95%CI 0.90%, 1.87%) of cases and 1.39% (95%CI 0.97%, 1.97%) of controls were exposed to a chair previously sat in by a shedding SARS-CoV-2 patient. Transmission risk among cases was not significantly different from controls (OR=0.94; 95%CI 0.57 to 1.54; p=0.80). Results remained consistent in adjusted and sensitivity analyses. LIMITATION: Analysis used real-world data that could contain errors and only considered vertical transmission associated with shared use of dialysis chairs by symptomatic patients. CONCLUSIONS: The risk of indirect patient-to-patient transmission of SARS-CoV-2 infection from dialysis chairs appears to be low. PRIMARY FUNDING SOURCE: Fresenius Medical Care North America; National Institute of Diabetes and Digestive and Kidney Diseases (R01DK130067).

9.
Int J Nephrol Renovasc Dis ; 14: 475-486, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34992426

RESUMEN

BACKGROUND: It has been proposed that substituting citrate-acidified dialysate (CAD) solutions for acetate-acidified dialysate (AAD) could improve hemodynamics and dialysis tolerance and reduce the requirement for systemic anticoagulation. Citrate chelates ionized calcium, but long-term effects of CAD use during maintenance hemodialysis have not been well studied. While many studies of the effects of CAD on serum calcium and intact parathyroid hormone (iPTH) have been short-term or have been limited by sample size, we aimed to determine if there are any long-term (i.e., 6-month) changes from pre-dialysis iPTH levels when patients are switched from AAD to CAD. METHODS: This retrospective cohort study compared various clinical parameters, including pre-dialysis iPTH and serum calcium as well as single pool Kt/V, from eligible patients who received in-center hemodialysis thrice-weekly in geographically matched CAD (n=3) or AAD clinics (n=12). CAD clinics were defined as clinics converting from AAD to CAD if >85% of the patients were prescribed CAD after implementation of CAD within the clinic. RESULTS: Pre-dialysis iPTH was not significantly different from baseline to 6-month follow-up within either CAD or AAD clinics. Moreover, the mean change from baseline to month 6 in iPTH between patients (n=142) in CAD clinics (-17 pg/mL) and patients (n=671) in AAD clinics (13 pg/mL) was similar (p = 0.24). Likewise, the differences in the mean change in serum calcium concentrations and dialysis adequacy (single pool Kt/V) were not significant between CAD and AAD clinics. For subgroups of patients who were never prescribed cinacalcet or calcium-based phosphate binders, there were no significantly different categorical shifts in iPTH between CAD and AAD clinics. CONCLUSION: Similar trends in single pool Kt/V, iPTH, and serum calcium levels were observed in clinics that switched from AAD to CAD versus the geographically matched AAD clinics. These results support CAD as a potential alternative to AAD in hemodialysis.

10.
Kidney360 ; 2(3): 456-468, 2021 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-35369017

RESUMEN

Background: We developed a machine learning (ML) model that predicts the risk of a patient on hemodialysis (HD) having an undetected SARS-CoV-2 infection that is identified after the following ≥3 days. Methods: As part of a healthcare operations effort, we used patient data from a national network of dialysis clinics (February-September 2020) to develop an ML model (XGBoost) that uses 81 variables to predict the likelihood of an adult patient on HD having an undetected SARS-CoV-2 infection that is identified in the subsequent ≥3 days. We used a 60%:20%:20% randomized split of COVID-19-positive samples for the training, validation, and testing datasets. Results: We used a select cohort of 40,490 patients on HD to build the ML model (11,166 patients who were COVID-19 positive and 29,324 patients who were unaffected controls). The prevalence of COVID-19 in the cohort (28% COVID-19 positive) was by design higher than the HD population. The prevalence of COVID-19 was set to 10% in the testing dataset to estimate the prevalence observed in the national HD population. The threshold for classifying observations as positive or negative was set at 0.80 to minimize false positives. Precision for the model was 0.52, the recall was 0.07, and the lift was 5.3 in the testing dataset. Area under the receiver operating characteristic curve (AUROC) and area under the precision-recall curve (AUPRC) for the model was 0.68 and 0.24 in the testing dataset, respectively. Top predictors of a patient on HD having a SARS-CoV-2 infection were the change in interdialytic weight gain from the previous month, mean pre-HD body temperature in the prior week, and the change in post-HD heart rate from the previous month. Conclusions: The developed ML model appears suitable for predicting patients on HD at risk of having COVID-19 at least 3 days before there would be a clinical suspicion of the disease.


Asunto(s)
COVID-19 , Adulto , COVID-19/diagnóstico , Humanos , Aprendizaje Automático , Curva ROC , Diálisis Renal , SARS-CoV-2
12.
Kidney Med ; 2(3): 307-316, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32734250

RESUMEN

RATIONALE & OBJECTIVE: High pill burden associates with reduced phosphate-binder adherence among dialysis patients, contributing to elevated serum phosphorus levels. We compared the real-world effectiveness of sucroferric oxyhydroxide (SO) versus other phosphate binders in hemodialysis patients over 2 years. STUDY DESIGN: Retrospective cohort study. SETTING & PARTICIPANTS: Adult in-center hemodialysis patients prescribed 2 years of uninterrupted SO therapy (maintenance SO; n = 222) compared with patients who discontinued SO therapy (discontinued SO; n = 596) within 90 days of first prescription and switched to other phosphate binder(s) for 2 years. EXPOSURES: Phosphate binders. OUTCOMES: Achievement of serum phosphorus levels ≤ 5.5 mg/dL, pill burden, and hospitalizations. ANALYTICAL APPROACH: Comparisons were made quarterly (Q1-Q8) between maintenance SO and discontinued SO using Poisson and mixed-effects linear regression. RESULTS: Patients achieving serum phosphorus levels ≤ 5.5 mg/dL increased from baseline in maintenance SO (46 [20.7%] to a maximum of 104 [46.8%; P < 0.001]) and discontinued SO (96 [16.1%] to a maximum of 201 [33.7%]; P < 0.001). 100 (45%) maintenance SO patients achieved target serum phosphorus levels at Q8 with 3.1 fewer pills per day from baseline (7.5 to 4.4 pills per day; P < 0.001), and 190 (31.9%) discontinued SO patients achieved serum phosphorus levels ≤ 5.5 mg/dL at Q8 with pill burden unchanged (9.1 to 9.3 pills per day; P = 0.3). Among all patients during 2 years, mean serum phosphorus levels decreased by -0.66 mg/dL and -0.45 mg/dL (maintenance SO vs discontinued SO; P = 0.014), and mean pill burden decreased in maintenance SO (8.5 to 5.1 pills per day; P < 0.001), but not in discontinued SO (11.6 to 10.9 pills per day; P = 0.2). The serum phosphorus level decrease with SO was confirmed in a sensitivity analysis including patients with SO therapy for 2 or fewer years. Compared with discontinued SO, maintenance SO patients had 35.6 fewer hospitalizations per 100 patient-years (incidence rate ratio, 0.75 [95% CI, 0.58-0.96]). LIMITATIONS: No data for treatment indication, tolerance, or adherence. CONCLUSIONS: Patients maintained on SO therapy were more likely to achieve target serum phosphorus levels, use 50% fewer phosphate-binder pills per day, and have fewer hospital admissions than patients switched to treatment with other binders.

13.
Clin Nephrol ; 93(4): 163-171, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32049627

RESUMEN

Maintaining phosphorus balance in in-center hemodialysis (ICHD) patients is problematic despite recommended dietary restriction, dialysis, and phosphate binder use. Rarely is P content in prescribed medications considered, but this source should raise concern. Data was obtained from the Fresenius Kidney Care (FKC) electronic data warehouse Knowledge Center and MedReview-eRx accessed Surescripts, housing > 80% of US-filled prescriptions. Adult FKC ICHD patients prescribed ≥ 1 medication in the MedReview-eRx database were analyzed (695,759 prescriptions). Information collected included medication dose, dose unit, dose timing, strength, start and stop dates, refills, demographic information, admission history, and modality type. Numbers of patients, prescriptions by individual medication, and drug class were then analyzed. Medications prescribed > 100 times were reported. Median doses/day (number of tablets) were calculated for each medication (open order on randomly selected day). Phosphate content of medications taken in FKC clinics was assessed using routinely used pharmacology references, and potential resulting phosphate and pill burden were also calculated. The top five prescribed drug classes in FKC dialysis patients were calcium-channel blockers (22%), proton pump inhibitors (PPIs; 18%), acetaminophen-opioid (AO; 13%), angiotensin-converting enzyme inhibitors (ACEi; 10%), and α2-agonists (9%). The maximum phosphate added for different medications varied by manufacturer. For instance, at median daily doses, phosphate contributions from the top five medications prescribed were 112 mg for amlodipine, 116.2 mg from lisinopril, 6.7 mg from clonidine, 0 mg from acetaminophen, and 200 mg for omeprazole. Prescribing these together could increase the daily phosphate load by 428 mg, forcing the patient to exceed the recommended daily intake (RDI) with food and drink. Phosphate content in medications prescribed to HD patients can substantially contribute to the daily phosphate load and, in combination, may even exceed the daily recommended dietary phosphate intake. Healthcare providers should monitor all medications containing phosphate prescribed in order to minimize risk of uncontrolled hyperphosphatemia and poor adherence.
.


Asunto(s)
Fosfatos/uso terapéutico , Diálisis Renal , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hiperfosfatemia/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Fosfatos/administración & dosificación , Fosfatos/metabolismo
14.
Kidney360 ; 1(4): 263-272, 2020 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-35372921

RESUMEN

Background: Combination therapy with multiple phosphate binders is prescribed to reduce elevated serum phosphorus (sP) concentrations among patients on maintenance hemodialysis. Sucroferric oxyhydroxide (SO), an iron-based phosphate binder, has demonstrated efficacy at reducing sP while also being associated with a low pill burden. Whereas the effects of SO monotherapy have been well characterized in clinical trials and observational cohorts, little is known about the effects of SO-containing combination therapy. Methods: Patients on hemodialysis (N=234) at Fresenius Kidney Care (FKC) who received ≥120 days of uninterrupted phosphate binder combination therapy with SO were included in this retrospective study. Patient data were censored after SO discontinuation, end of care at FKC, or completion of 12 months of follow-up. Quarterly (Q) changes in phosphate binder pill burden, mean sP, and proportion of patients achieving National Kidney Foundation Kidney Disease Outcomes Quality Initiative (NKF-KDOQI)-recommended sP levels (≤5.5 mg/dl) were compared between baseline (-Q1) and follow-up (Q1-Q4). Results: Phosphate binder combination therapy with SO was associated with significant increase in the proportion of patients with sP ≤5.5 mg/dl (from 19% at baseline to up to 40% at follow-up; P<0.001) and reduction in sP at all postbaseline time points (from 6.7 mg/dl to 6.2-6.3 mg/dl; P<0.001). Patients on calcium acetate (N=54) and sevelamer (N=94) who added SO therapy at follow-up resulted in a ≥250% increase in patients achieving sP ≤5.5 mg/dl (all P<0.001). Whereas mean phosphate binder pill burden increased with initiation of phosphate binder combination therapy with SO (15.8 pills/d at Q1 versus 12.3 pills/d at -Q1), continued use of SO was associated with down-titration of non-SO phosphate binders such that, by Q4, mean total PB pill burden reduced to 12.3 pills/d. Conclusions: For patients on hemodialysis with uncontrolled hyperphosphatemia, combination therapy with SO may allow for sustained improvements in sP control without adversely affecting phosphate binder pill burden.


Asunto(s)
Diálisis Renal , Sacarosa , Combinación de Medicamentos , Compuestos Férricos , Humanos , Fosfatos , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Sacarosa/uso terapéutico
16.
BMC Nephrol ; 20(1): 396, 2019 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-31664928

RESUMEN

BACKGROUND: Elevated serum phosphorus concentrations are common among maintenance hemodialysis patients. Protein is a major source of dietary phosphate, but restriction of protein intake can result in hypoalbuminemia and protein-energy wasting. We hypothesized that sucroferric oxyhydroxide (SO), a potent phosphate binder with a low pill burden, may reduce serum phosphorus levels in hemodialysis patients with hypoalbuminemia without adversely impacting albumin levels or dietary intake of protein. METHODS: We retrospectively examined de-identified data from 79 adult, in-center hemodialysis patients with baseline hypoalbuminemia (≤ 3.5 g/dL) switched to SO as part of routine clinical care for at least 1 year. Temporal changes (3-month intervals from baseline through Q4) in phosphate binder pill burden, serum phosphorous levels, nutritional markers, and equilibrated Kt/V were analyzed. Data from a matched reference group of non-hypoalbuminemic patients (N = 79) switched to SO were also examined. RESULTS: SO therapy was associated with a mean reduction of 45.7 and 45.1% in daily phosphate binder pill burden, and a mean reduction of 0.4 mg/dL and 0.51 mg/dL in serum phosphorus levels for the hypoalbuminemic and non-hypoalbuminemic patients, respectively. Hypoalbuminemic patients demonstrated significant increases in mean serum albumin levels from 3.50 mg/dL at baseline to 3.69, 3.74, 3.70, and 3.69 mg/dL during Q1 through Q4, respectively (P < 0.0001), whereas serum albumin levels remained unchanged in the non-hypoalbuminemic group. CONCLUSIONS: Both hypoalbuminemic and non-hypoalbuminemic patients switching to SO exhibited significant reductions in serum phosphorus concentrations and daily phosphate binder pill burden. Among hypoalbuminemic patients, the initiation of SO therapy was also associated with increases in serum albumin, suggesting therapy may have allowed patients to increase their dietary intake of protein.


Asunto(s)
Proteínas en la Dieta/administración & dosificación , Compuestos Férricos/administración & dosificación , Hipoalbuminemia/sangre , Fósforo/sangre , Diálisis Renal , Insuficiencia Renal Crónica/sangre , Sacarosa/administración & dosificación , Estudios de Cohortes , Creatinina/sangre , Combinación de Medicamentos , Sustitución de Medicamentos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Hormona Paratiroidea/sangre , Fosfatos/metabolismo , Insuficiencia Renal Crónica/terapia , Estudios Retrospectivos , Albúmina Sérica/metabolismo
17.
J Ren Nutr ; 29(5): 428-437, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30679076

RESUMEN

OBJECTIVE: The high pill burden of many phosphate binders (PBs) may contribute to increased prevalence of hyperphosphatemia and poor nutritional status observed among patients undergoing maintenance hemodialysis therapy. We examined the real-world effectiveness of sucroferric oxyhydroxide (SO), a PB with low pill burden, in managing serum phosphorus in patients with prevalent hemodialysis over a 1-year period. DESIGN: Historical cohort analyses of de-identified electronic medical records. SUBJECTS: In-center hemodialysis patients switched from another PB to SO therapy as part of routine care with 12 months of uninterrupted SO prescriptions recorded, and documented serum phosphorus levels were eligible for inclusion. Clinical data were extracted from a pharmacy service, FreseniusRx, database and Fresenius Kidney Care clinical data warehouse. MAIN OUTCOME MEASURES: Comparisons were made between the 91-day period before SO initiation (i.e., baseline) and the 4 consecutive 91-day intervals of SO treatment (Q1-Q4). Clinical measures included achievement of target phosphorus levels (≤5.5 mg/dL) and mean number of PB pills/day. RESULTS: Among 530 analyzed patients, the proportion achieving target serum phosphorus levels increased by >100% 1 year after switching to SO therapy, that is, from 17.7% at baseline to 24.5%, 30.5%, 36.4%, and 36.0% at Q1 through Q4, respectively (P < .0001 for all). Reductions in serum phosphorus were observed at all follow-up timepoints (P < .0001), irrespective of baseline PB. From a mean baseline PB pill burden of 8.5 pills/day, patients experienced an average 50% pill burden reduction during SO treatment (P < .0001). Phosphorus-attuned albumin and phosphorus-attuned protein intake (normalized protein catabolic rate) improved significantly after transition to SO (P < .0001). The effectiveness of SO was evident in prespecified subgroups of interest (i.e., black/African-American patients, Hispanic/Latino patients, and women). CONCLUSION: Among patients on hemodialysis, switching to SO resulted in a 2-fold greater likelihood of achieving target phosphorus levels while halving daily PB pill burden. Increases in phosphorus-attuned albumin and protein intake suggest improved nutritional status.


Asunto(s)
Compuestos Férricos/uso terapéutico , Hiperfosfatemia/tratamiento farmacológico , Fósforo/sangre , Diálisis Renal , Insuficiencia Renal/terapia , Sacarosa/uso terapéutico , Adulto , Anciano , Quelantes/uso terapéutico , Estudios de Cohortes , Combinación de Medicamentos , Femenino , Humanos , Masculino , Cumplimiento de la Medicación , Persona de Mediana Edad , Estado Nutricional , Fosfatos/sangre , Insuficiencia Renal/sangre , Factores de Tiempo , Resultado del Tratamiento
18.
Am J Nephrol ; 47(3): 153-161, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29514139

RESUMEN

BACKGROUND: A database analysis was conducted to assess the effectiveness of sucroferric oxyhydroxide (SO) on lowering serum phosphorus and phosphate binder (PB) pill burden among adult peritoneal dialysis (PD) patients prescribed SO as part of routine care. METHODS: Adult PD patients (n = 258) prescribed SO through a renal pharmacy service were analyzed. Baseline was 3 months before SO prescription. SO-treated follow-up was for 6 months or until either a new PB was prescribed, SO was not refilled, PD modality changed, or patient was discharged. In-range serum phosphorus was defined as ≤5.5 mg/dL. RESULTS: At baseline, mean serum phosphorus was 6.59 mg/dL with 10 prescribed PB pills/day. The proportion of patients achieving in-range serum phosphorus increased by 72% from baseline to month 6. Prescribed PB pills/day decreased by 57% (10 at baseline to 4.3 at SO follow-up, p < 0.0001). The mean length of SO follow-up was 5.1 months; SO follow-up ended for 38, 27, and 50 patients at months 4, 5, and 6, respectively, due to no further PB fills, and for 10, 11, and 4 patients at months 4, 5, and 6, respectively, due to another PB prescribed. In patients with baseline serum phosphorus >5.5 mg/dL who achieved in-range serum phosphorus during SO follow-up for ≥1 quarter, a notable improvement in serum phosphorus (6.54 to 5.10 mg/dL, p < 0.0001) was observed, and there was a 53% reduction in PB pill burden (9.9 to 4.7, p < 0.0001). CONCLUSION: Among PD patients prescribed SO as part of routine care, improvements in serum phosphorus control and >50% reduction in PB pills/day were observed.


Asunto(s)
Compuestos Férricos/administración & dosificación , Hiperfosfatemia/tratamiento farmacológico , Fallo Renal Crónico/complicaciones , Sacarosa/administración & dosificación , Adulto , Anciano , Combinación de Medicamentos , Femenino , Humanos , Hiperfosfatemia/etiología , Fallo Renal Crónico/sangre , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Diálisis Peritoneal , Fósforo/sangre , Estudios Retrospectivos
19.
Blood Purif ; 45(1-3): 224-229, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29478056

RESUMEN

BACKGROUND/AIM: Home hemodialysis (HHD) has been associated with improved clinical outcomes vs. in-center HD (ICHD). The prevalence of HHD in the United States is still very low at 1.8%. This critical review compares HHD and ICHD outcomes for survival, hospitalization, cardiovascular (CV), nutrition, and quality of life (QoL). METHODS: Of 545 publications identified, 44 were not selected after applying exclusion criteria. A systematic review of the identified publications was conducted to compare HHD to ICHD outcomes for survival, hospitalization, CV outcomes, nutrition, and QoL. RESULTS: Regarding mortality, 10 of 13 trials reported 13-52% reduction; three trials found no differences. According to 6 studies, blood pressure and left ventricular size measurements were generally lower in HHD patients compared to similar measurements in ICHD patients. Regarding nutritional status, conflicting results were reported (8 studies); some found improved muscle mass, total protein, and body mass index in HHD vs. ICHD patients, while others found no significant differences. There were no significant differences in the rate of hospitalization between HHD and ICHD in the 6 articles reviewed. Seven studies on QoL demonstrated positive trends in HHD vs. ICHD populations. CONCLUSIONS: Despite limitations in the current data, 66% of the publications reviewed (29/44) demonstrated improved clinical outcomes in patients who chose HHD. These include improved survival, CV, nutritional, and QoL parameters. Even though HHD may not be preferred in all patients, a review of the literature suggests that HHD should be provided as a modality choice for substantially more than the current 1.8% of HHD patients in the United States.


Asunto(s)
Hemodiálisis en el Domicilio/métodos , Fallo Renal Crónico/mortalidad , Fallo Renal Crónico/terapia , Ensayos Clínicos como Asunto , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Tasa de Supervivencia , Estados Unidos/epidemiología
20.
Hemodial Int ; 22(4): 425-434, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29210176

RESUMEN

Dialysis dose is an important determinant of clinical outcomes in patients with end stage renal disease on maintenance dialysis. In clinical practice dialysis dose is monitored at least monthly by urea clearance based on Urea Kinetic Modeling. Online clearance monitoring using effective ionic dialysance (EID) of sodium (Na+ ) is available on some hemodialysis machines. This paper reviews the background, methodology, additional applications, and potential risks associated with EID. Effective ionic dialysance provides a reliable, real-time, noninvasive, and inexpensive measurement of dialysis dose during an ongoing hemodialysis (HD) session to allow interventions and assess the impact of these changes on clearance. Surveillance of vascular access flow rates can be used to screen for access dysfunction and refer for interventions. There is a concern that EID measurements may cause Na+ loading because of high dialysate Na+ used during these measurements, however, mathematical models, in vitro experiments, and clinical studies in patients on maintenance HD do not show any evidence of Na+ loading during EID measurements. We cannot rule out the possibility of nonosmotic Na+ accumulation in the skin because no published literature exists on this topic as it pertains to clearance measurements based on EID of Na+ .


Asunto(s)
Soluciones para Diálisis/uso terapéutico , Diálisis Renal/métodos , Sodio/metabolismo , Soluciones para Diálisis/farmacología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...