Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Rep Pract Oncol Radiother ; 28(1): 79-87, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37122914

RESUMEN

Background: The purpose of this manuscript is to provide an in-depth literature review of the management of endometrial and cervical cancers with electronic brachytherapy. Materials and methods: An extensive literature search was performed and 9 articles were selected based on preset criteria. Results: The reviewed studies provided dosimetric and clinical results. Patient populations were diverse and prescribed doses varied. When treatment plans were compared to those using cobalt 60 (60Co) and iridium 192 (192Ir) sources researchers found lower or equivalent doses in organs at risk while the doses at the applicator surface were significantly higher for electronic brachytherapy. In the eligible studies, a total of 72 patients received treatment with AxxentXoft vaginal applicator, 29 were treated with the Intrabeam vaginal applicator, and 8 with AxxentXoft cervical applicator. Conclusions: All authors found that electronic brachytherapy was safe and well tolerated as higher mucosal doses did not present as adverse clinical effects. Electronic brachytherapy for gynecological cancers has the potential to achieve equivalent tumor control while minimizing bowel and urinary toxicity thus improving the quality of life. More clinical data is needed to stratify patients who would benefit the most.

2.
Phys Med ; 108: 102572, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36989978

RESUMEN

INTRODUCTION: The implementation of diagnostic reference levels (DRLs) is an essential tool for optimisation of the routine practice, better management of patient exposure while maintaining sufficient image quality. National DRLs for electrophysiology (EP) procedures are not available in our country. PURPOSE: The main purpose of the study was to propose, for first time in Bulgaria, national DRLs (NDRLs) for EP studies and ablation procedures of two different levels of complexity. The proposed DRLs can be later used to establish NDRLs by the national authority with regulatory functions related to medical exposure. METHOD: A retrospective study was done with the three highest volume Bulgarian EP centers, where over 95% of all cardiac ablations were performed. Data were extracted from the electronic registry for invasive electrophysiology BG-EPHY. Independently of the proposed NDRLs, we also compared the air kerma-area product (KAP) between the participating centers for procedures of the same level of complexity. RESULTS: The proposed NDRL in terms of KAP were: 5.2 Gy.cm2 for diagnostic EP studies, 25.5 Gy.cm2 for simple ablations, and 52.1 Gy.cm2 for complex ablations. There was a significant variation in KAP for procedures with the same degree of complexity within each center. CONCLUSION: This study is the first to propose NDLRs for EP studies and ablation procedures of two levels of complexity in Bulgaria. The results identified EP procedures requiring further optimization of patient protection and provided a basis for future comparisons and standardization with further investigations on the topic. The proposed NDRLs are recommended to be used for better management of radiation exposure during EP procedures of different levels of complexity.


Asunto(s)
Ablación por Catéter , Niveles de Referencia para Diagnóstico , Humanos , Bulgaria , Estudios Retrospectivos , Electrofisiología , Dosis de Radiación , Fluoroscopía
3.
Curr Oncol ; 28(5): 3932-3944, 2021 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-34677253

RESUMEN

(1) Background: We aimed to analyze currently available studies with intraoperative radiotherapy (IORT) as a choice of treatment where the Xoft Axxent® electronic brachytherapy (eBx) system was used as a single-dose irradiation and an exclusive radiotherapy approach at the time of surgery in patients with early breast cancer (EBC). We also compared the results of the systematic review to the Bulgarian experience. (2) Methods and Materials: We performed a systematic review of the studies published before February 2021, which investigate the application of a single-fraction 20 Gy radiation treatment, delivered at the time of lumpectomy in EBC patients with the Xoft Axxent® eBx System. A systematic search in PubMed, Scopus, and ScienceDirect was performed. The results are reported following the PRISMA guidelines. The criteria on patients' selection for IORT (the additional need for EBRT), cosmetic outcomes, and recurrence rate from the eligible studies are compared to the treatment results in Bulgarian patients. (3) Results: We searched through 1032 results to find 17 eligible studies. There are no published outcomes from randomized trials. When reported, the cosmetic outcomes in most of the studies are defined as excellent. The observed recurrence rate is low (1-5.8%). Still, the number of patients additionally referred to postoperative external breast radiotherapy (EBRT) is up to 31%. Amongst the 20 patients treated in Bulgaria, the cosmetic outcomes are also evaluated as excellent, five of which (25%) are referred for EBRT. Within median follow-up of 39 months, there was one local and one distal recurrence. (4) Conclusions: Current evidence demonstrates the Xoft Axxent® eBx system as a safe and feasible technique for IORT delivery in EBC patients. There are no randomized controlled trials conducted at this time point to prove its long-term effectiveness. Better patient selection and a reimbursement strategy have to be proposed to extend the application of this technique in Bulgaria.


Asunto(s)
Braquiterapia , Neoplasias de la Mama , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Bulgaria , Electrónica , Femenino , Humanos , Recurrencia Local de Neoplasia
4.
Br J Radiol ; 94(1128): 20210439, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34591595

RESUMEN

OBJECTIVES: Constantly increasing number of procedures performed - endovascular or hybrid in patients with aortoiliac occlusive disease during the last decades finds its explanation in the lower morbidity and mortality rates, compared to bypass surgery. The purpose of the current survey was to estimate patients' radiation exposure in aortoiliac segment after endovascular or hybrid revascularization and to study the main factors which have direct contribution. METHODS: A retrospective study of 285 procedures conducted with the help of a mobile C-arm system in 223 patients was performed. Procedures were grouped according to criteria such as: type of intervention, vascular access, level of complexity and operating team. Different analyses were performed within the groups and dose values. RESULTS: The median values of kerma-air product (KAP), the number of series and the peak skin dose (PSD) significantly increase with the increasing number of vascular accesses: for one access (16.68 Gy.cm2, 6 and 336 mGy), for two (56.93 Gy.cm2, 11 and 545 mGy), and for three (102.28 Gy.cm2, 15 and 781 mGy). Significant dependence was observed in the case of single access site between the type of access and the dose values: hybrid and retrograde common femoral artery/superficial femoral artery (CFA/SFA) endovascular accesses, 10.06 Gy.cm2/301 mGy and 13.23 Gy.cm2/318 mGy respectively, in contrast with the contralateral CFA and left brachial access, 33 Gy.cm2/421 mGy and 38.33 Gy.cm2/448 mGy respectively. CONCLUSION: The results demonstrate that the most important factors increasing the dose values are number and type of vascular accesses, followed by the combination and number of implanted stents with the complexity of the procedure. The PSD values for a single procedure were between 2 and 12 times lower than those IAEA proposed as trigger levels for radiation-induced erythema. This study shows that trigger levels were not reached even for patients with repeated procedures in the same segment in 1-year period. ADVANCES IN KNOWLEDGE: The study gives important understanding and clarity on the growing awareness for dose-modifying factors during endovascular and hybrid revascularization of aortoiliac segment.


Asunto(s)
Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/cirugía , Procedimientos Endovasculares/métodos , Dosis de Radiación , Radiografía Intervencional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Aorta/cirugía , Femenino , Fluoroscopía , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Masculino , Persona de Mediana Edad , Radiografía Intervencional/estadística & datos numéricos , Estudios Retrospectivos
5.
Radiology ; 298(3): E141-E151, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33170104

RESUMEN

Background There is lack of guidance on specific CT protocols for imaging patients with coronavirus disease 2019 (COVID-19) pneumonia. Purpose To assess international variations in CT utilization, protocols, and radiation doses in patients with COVID-19 pneumonia. Materials and Methods In this retrospective data collection study, the International Atomic Energy Agency coordinated a survey between May and July 2020 regarding CT utilization, protocols, and radiation doses from 62 health care sites in 34 countries across five continents for CT examinations performed in patients with COVID-19 pneumonia. The questionnaire obtained information on local prevalence, method of diagnosis, most frequent imaging, indications for CT, and specific policies on use of CT in COVID-19 pneumonia. Collected data included general information (patient age, weight, clinical indication), CT equipment (CT make and model, year of installation, number of detector rows), scan protocols (body region, scan phases, tube current and potential), and radiation dose descriptors (CT dose index and dose length product). Descriptive statistics and generalized estimating equations were performed. Results Data from 782 patients (median age, 59 years [interquartile range, 15 years]) from 54 health care sites in 28 countries were evaluated. Less than one-half of the health care sites used CT for initial diagnosis of COVID-19 pneumonia and three-fourths used CT for assessing disease severity. CT dose index varied based on CT vendors (7-11 mGy; P < .001), number of detector rows (8-9 mGy; P < .001), year of CT installation (7-10 mGy; P = .006), and reconstruction techniques (7-10 mGy; P = .03). Multiphase chest CT examinations performed at 20% of sites (11 of 54) were associated with higher dose length product compared with single-phase chest CT examinations performed in 80% of sites (43 of 54) (P = .008). Conclusion CT use, scan protocols, and radiation doses in patients with coronavirus disease 2019 pneumonia showed wide variation across health care sites within the same and between different countries. Many patients were imaged multiple times and/or with multiphase CT scan protocols. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Lee in this issue.


Asunto(s)
COVID-19/diagnóstico por imagen , Protocolos Clínicos , Internacionalidad , Pulmón/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , SARS-CoV-2
6.
Phys Med ; 64: 293-303, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31387779

RESUMEN

PURPOSE: We present the development and the current state of the MaXIMA Breast Lesions Models Database, which is intended to provide researchers with both segmented and mathematical computer-based breast lesion models with realistic shape. METHODS: The database contains various 3D images of breast lesions of irregular shapes, collected from routine patient examinations or dedicated scientific experiments. It also contains images of simulated tumour models. In order to extract the 3D shapes of the breast cancers from patient images, an in-house segmentation algorithm was developed for the analysis of 50 tomosynthesis sets from patients diagnosed with malignant and benign lesions. In addition, computed tomography (CT) scans of three breast mastectomy cases were added, as well as five whole-body CT scans. The segmentation algorithm includes a series of image processing operations and region-growing techniques with minimal interaction from the user, with the purpose of finding and segmenting the areas of the lesion. Mathematically modelled computational breast lesions, also stored in the database, are based on the 3D random walk approach. RESULTS: The MaXIMA Imaging Database currently contains 50 breast cancer models obtained by segmentation of 3D patient breast tomosynthesis images; 8 models obtained by segmentation of whole body and breast cadavers CT images; and 80 models based on a mathematical algorithm. Each record in the database is supported with relevant information. Two applications of the database are highlighted: inserting the lesions into computationally generated breast phantoms and an approach in generating mammography images with variously shaped breast lesion models from the database for evaluation purposes. Both cases demonstrate the implementation of multiple scenarios and of an unlimited number of cases, which can be used for further software modelling and investigation of breast imaging techniques. The created database interface is web-based, user friendly and is intended to be made freely accessible through internet after the completion of the MaXIMA project. CONCLUSIONS: The developed database will serve as an imaging data source for researchers, working on breast diagnostic imaging and on improving early breast cancer detection techniques, using existing or newly developed imaging modalities.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Bases de Datos Factuales , Cadáver , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X
7.
Br J Radiol ; 91(1091): 20180176, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30028182

RESUMEN

OBJECTIVE:: Hybrid surgical methods such as remote endarterectomy and endovascular revascularization are fluoroscopy-guided procedures successfully replacing conventional open surgery for treatment of peripheral artery disease (PAD). The aim of this study was to: (1) evaluate the dose parameters describing exposure of patients undergoing endovascular or hybrid revascularization of the lower limb (below the inguinal ligament); (2) compare the data available in the literature with the evaluations of patients' dose values and related factors for patients undergoing such procedures; (3) examine the correlation of doses with certain parameters; (4) estimate the peak skin dose and assess the potential for radiation-induced skin injuries during the procedures. METHODS:: Data for 259 patients were extracted retrospectively and analyzed. The procedures were grouped by type of intervention, vascular approach, and level of complexity. The analyses included the correlation of dose values with the operating team. RESULTS:: The air kerma-area product (KAP) and fluoroscopy time (FT) values greatly varied depending on the procedure type but also among patients undergoing the same procedure. The type of vascular access has the largest impact on patients' doses. The KAP and FT values for brachial artery were: 347 Gy.cm2 and FT: NA; for contralateral common femoral artery (CFA) approach: 207 Gy.cm2 and 153 s; e.g. significantly higher than for ipsilateral CFA: 96 Gy.cm2 and 78 s; for hybrid surgery: 77 Gy.cm2 and 41 s; and for ipsilateral retrograde popliteal approach: 61 Gy.cm2 and 53 s. The same tendency is observed for the peak skin dose (PSD) values: the highest are for brachial artery (2053 mGy) and contralateral CFA (1325 mGy) approach, followed by the ipsilateral CFA (748 mGy), hybrid surgery (649 mGy), and ipsilateral retrograde popliteal approach (566 mGy). CONCLUSION:: Registered dose values and FT for the different procedures do not exceed the International Atomic Energy Agency (IAEA) proposed trigger values for patients' follow-up for radiation-induced skin injuries. The type of vascular access has the highest negative impact on radiation dose levels and resultant KAP, PSD, and FT values. There is a significant increase of the dose values with increase of the number of inserted stents and the level of complexity. This should be considered in planning, especially for patients who undergo multiple diagnostic and therapeutic procedures. ADVANCES IN KNOWLEDGE:: This study gives a systematic understanding for patient radiation exposure in endovascular and hybrid revascularization of the lower extremities, thus far absent in the literature.


Asunto(s)
Endarterectomía/métodos , Procedimientos Endovasculares/métodos , Pierna/irrigación sanguínea , Enfermedades Vasculares Periféricas/cirugía , Reperfusión/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia/métodos , Femenino , Arteria Femoral/cirugía , Fluoroscopía/métodos , Humanos , Masculino , Persona de Mediana Edad , Arteria Poplítea/cirugía , Dosis de Radiación , Estudios Retrospectivos
8.
Eur Radiol ; 23(3): 623-31, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22940731

RESUMEN

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Asunto(s)
Accesibilidad a los Servicios de Salud/estadística & datos numéricos , Pediatría/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , África/epidemiología , Asia/epidemiología , Europa (Continente)/epidemiología , Encuestas de Atención de la Salud , Humanos , América Latina/epidemiología , Dosis de Radiación
9.
AJR Am J Roentgenol ; 198(5): 1021-31, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22528891

RESUMEN

OBJECTIVE: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION: With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.


Asunto(s)
Pautas de la Práctica en Medicina/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , África , Asia , Niño , Preescolar , Europa (Continente) , Humanos , Lactante , Recién Nacido , Agencias Internacionales , América Latina , Dosis de Radiación , Protección Radiológica , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...