Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38796803

RESUMEN

PURPOSE: This study examines the hepatic extracellular volume fraction (ECV) disparity between the left and right lobes (ECV_left and ECV_right) in patients with chronic thromboembolic pulmonary hypertension (CTEPH), its association with right heart catheterization (RHC) metrics, and with intolerance to increased pulmonary hypertension (PH)-targeted medication dosages. METHODS: We retrospectively analyzed 72 CTEPH-diagnosed patients who underwent equilibrium-phase abdominal dual-energy CT (DECT) and RHC. Hepatic ECVs, derived from DECT's iodine maps using circular regions of interest in the liver and aorta, were correlated with RHC parameters via Spearman's rank correlation and lobe differences through the Wilcoxon signed-rank test. Logistic regression assessed cases with ECV_left exceeding ECV_right by > 0.05, while receiver operating characteristic curve analysis gauged ECVs' predictive power for medication intolerance. RESULTS: Of the 72 patients (57 females; median age 69), ECV_total (0.24, IQR 0.20-0.27) moderately correlated with RHC parameters (rs = 0.28, -0.24, 0.3 for mean pulmonary arterial pressure, cardiac index [CI], and pulmonary vascular resistance index, respectively). ECV_left significantly surpassed ECV_right (0.25 vs. 0.22, p < 0.001), with a greater ECV_left by > 0.05 indicating notably lower CI (p < 0.001). In 27 patients on PH medication, ECV_left effectively predicted medication intolerance (AUC = 0.84). CONCLUSION: In CTEPH patients, hepatic ECV correlated with RHC metrics, where elevated left lobe ECV suggested reduced CI and potential medication intolerance.

2.
J Cardiovasc Electrophysiol ; 34(6): 1473-1476, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37222178

RESUMEN

BACKGROUND: Atrial lead perforation may lead to pneumopericardium or pneumothorax within a few days of device implantation. METHODS AND RESULTS: We report a case of atrial lead perforation 6 years after cardiac resynchronization therapy implantation, which resulted in pneumopericardium and pneumothorax. CONCLUSION: Although pneumopericardium caused by atrial lead perforation can spontaneously resolve with conservative treatment, as it did in this case, treatment should be decided based on the patient's general condition and lead performance.


Asunto(s)
Fibrilación Atrial , Lesiones Cardíacas , Marcapaso Artificial , Neumopericardio , Neumotórax , Humanos , Marcapaso Artificial/efectos adversos , Fibrilación Atrial/complicaciones , Neumopericardio/diagnóstico por imagen , Neumopericardio/etiología , Neumopericardio/terapia , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Neumotórax/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia
3.
Acad Radiol ; 30(11): 2505-2513, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36868878

RESUMEN

RATIONALE AND OBJECTIVES: Coronary inflammation related to high-risk hemorrhagic plaques can be captured by the perivascular fat attenuation index (FAI) using coronary computed tomography angiography (CCTA). Since the FAI is susceptible to image noise, we believe deep learning (DL)-based post hoc noise reduction can improve diagnostic capability. We aimed to assess the diagnostic performance of the FAI in DL-based denoised high-fidelity CCTA images compared with coronary plaque magnetic resonance imaging (MRI) delivered high-intensity hemorrhagic plaques (HIPs). MATERIALS AND METHODS: We retrospectively reviewed 43 patients who underwent CCTA and coronary plaque MRI. We generated high-fidelity CCTA images by denoising the standard CCTA images using a residual dense network that supervised the denoising task by averaging three cardiac phases with nonrigid registration. We measured the FAIs as the mean CT value of all voxels (range of -190 to -30 HU) located within a radial distance from the outer proximal right coronary artery wall. The diagnostic reference standard was defined as HIPs (high-risk hemorrhagic plaques) using MRI. The diagnostic performance of the FAI in the original and denoised images was assessed using receiver operating characteristic curves. RESULTS: Of 43 patients, 13 had HIPs. The denoised CCTA improved the area under the curve (0.89 [95% confidence interval (CI) 0.78-0.99]) of the FAI compared with that in the original image (0.77 [95% CI, 0.62-0.91], p = 0.008). The optimal cutoff value for predicting HIPs in denoised CCTA was -69 HU with 0.85 (11/13) sensitivity, 0.79 (25/30) specificity, and 0.80 (36/43) accuracy. CONCLUSION: DL-based denoised high-fidelity CCTA improved the AUC and specificity of the FAI for predicting HIPs.

4.
Eur Radiol ; 33(7): 4688-4697, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36809433

RESUMEN

OBJECTIVES: To determine the optimal inversion time (TI) from Look-Locker scout images using a convolutional neural network (CNN) and to investigate the feasibility of correcting TI using a smartphone. METHODS: In this retrospective study, TI-scout images were extracted using a Look-Locker approach from 1113 consecutive cardiac MR examinations performed between 2017 and 2020 with myocardial late gadolinium enhancement. Reference TI null points were independently determined visually by an experienced radiologist and an experienced cardiologist, and quantitatively measured. A CNN was developed to evaluate deviation of TI from the null point and then implemented in PC and smartphone applications. Images on 4 K or 3-megapixel monitors were captured by a smartphone, and CNN performance on each monitor was determined. Optimal, undercorrection, and overcorrection rates using deep learning on the PC and smartphone were calculated. For patient analysis, TI category differences in pre- and post-correction were evaluated using the TI null point used in late gadolinium enhancement imaging. RESULTS: For PC, 96.4% (772/749) of images were classified as optimal, with under- and overcorrection rates of 1.2% (9/749) and 2.4% (18/749), respectively. For 4 K images, 93.5% (700/749) of images were classified as optimal, with under- and overcorrection rates of 3.9% (29/749) and 2.7% (20/749), respectively. For 3-megapixel images, 89.6% (671/749) of images were classified as optimal, with under- and overcorrection rates of 3.3% (25/749) and 7.0% (53/749), respectively. On patient-based evaluations, subjects classified as within optimal range increased from 72.0% (77/107) to 91.6% (98/107) using the CNN. CONCLUSIONS: Optimizing TI on Look-Locker images was feasible using deep learning and a smartphone. KEY POINTS: • A deep learning model corrected TI-scout images to within optimal null point for LGE imaging. • By capturing the TI-scout image on the monitor with a smartphone, the deviation of the TI from the null point can be immediately determined. • Using this model, TI null points can be set to the same degree as that by an experienced radiological technologist.


Asunto(s)
Medios de Contraste , Aprendizaje Profundo , Humanos , Medios de Contraste/farmacología , Gadolinio , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Teléfono Inteligente
7.
Radiology ; 305(1): 82-91, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35762889

RESUMEN

Background To improve myocardial delayed enhancement (MDE) CT, a deep learning (DL)-based post hoc denoising method supervised with averaged MDE CT data was developed. Purpose To assess the image quality of denoised MDE CT images and evaluate their diagnostic performance by using late gadolinium enhancement (LGE) MRI as a reference. Materials and methods MDE CT data obtained by averaging three acquisitions with a single breath hold 5 minutes after the contrast material injection in patients from July 2020 to October 2021 were retrospectively reviewed. Preaveraged images obtained in 100 patients as inputs and averaged images as ground truths were used to supervise a residual dense network (RDN). The original single-shot image, standard averaged image, RDN-denoised original (DLoriginal) image, and RDN-denoised averaged (DLave) image of holdout cases were compared. In 40 patients, the CT value and image noise in the left ventricular cavity and myocardium were assessed. The segmental presence of MDE in the remaining 40 patients who underwent reference LGE MRI was evaluated. The sensitivity, specificity, and accuracy of each type of CT image and the improvement in accuracy achieved with the RDN were assessed using odds ratios (ORs) estimated with the generalized estimation equation. Results Overall, 180 patients (median age, 66 years [IQR, 53-74 years]; 107 men) were included. The RDN reduced image noise to 28% of the original level while maintaining equivalence in the CT values (P < .001 for all). The sensitivity, specificity, and accuracy of the original images were 77.9%, 84.4%, and 82.3%, of the averaged images were 89.7%, 87.9%, and 88.5%, of the DLoriginal images were 93.1%, 87.5%, and 89.3%, and of the DLave images were 95.1%, 93.1%, and 93.8%, respectively. DLoriginal images showed improved accuracy compared with the original images (OR, 1.8 [95% CI: 1.2, 2.9]; P = .011) and DLave images showed improved accuracy compared with the averaged images (OR, 2.0 [95% CI: 1.2, 3.5]; P = .009). Conclusion The proposed denoising network supervised with averaged CT images reduced image noise and improved the diagnostic performance for myocardial delayed enhancement CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Vannier and Wang in this issue.


Asunto(s)
Medios de Contraste , Aprendizaje Profundo , Anciano , Gadolinio , Humanos , Masculino , Miocardio , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
8.
Radiol Cardiothorac Imaging ; 4(6): e220111, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36601449

RESUMEN

Purpose: To evaluate the image quality of high-spatial-resolution two-dimensional (2D) late gadolinium enhancement (LGE) cardiac MRI compared with conventional normal-resolution LGE MRI. Materials and Methods: This prospective study included participants suspected of having cardiomyopathy who underwent cardiac MRI between March 2021 and December 2021. Normal-resolution and high-resolution 2D LGE sequences (inversion recovery [IR] and phase-sensitive inversion recovery [PSIR]) were performed at 3 T. Resolution was compared between normal-resolution and high-resolution images obtained in a quality assurance phantom. In vivo image quality and resolution were evaluated qualitatively using a five-point scoring system. Receiver operating characteristic curve analysis was used for LGE detection performance. Border sharpness was assessed with profile curve measurement. The contrast-to-noise ratio (CNR) between hyperenhancement and remote myocardium and LGE detection performance were calculated using normal-resolution IR images as the reference. Results: In total, 120 participants were evaluated (mean age, 56 years ± 17 [SD]; 72 men). Features smaller than 1 mm were detectable only on high-resolution images of the phantom. In vivo, the image resolution score with high-resolution LGE was 4.14-4.24, which was higher than the normal-resolution LGE reference score of 2.99 (P < .05). Border sharpness was higher in high-resolution images (P < .001). Receiver operating characteristic curve analysis revealed no evidence of a difference in LGE detection between normal-resolution and high-resolution images. There was also no evidence of a change in CNR of LGE in IR and PSIR magnitude compared with reference images. Conclusion: Comparison of image quality in 2D high-resolution and normal-resolution LGE cardiac MRI demonstrated the highest resolution for high-resolution IR and high-resolution PSIR magnitude sequences.Keywords: Cartilage Imaging, MRI, Cardiac, Heart, Imaging Sequences, Comparative Studies Supplemental material is available for this article. © RSNA, 2022.

9.
PLoS One ; 16(11): e0260456, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34843578

RESUMEN

BACKGROUND: Right ventricular function is an important prognostic marker for pulmonary arterial hypertension. Native T1 mapping using cardiovascular magnetic resonance imaging can characterize the myocardium, but accumulating evidence indicates that T1 values of the septum or ventricular insertion points do not have predictive potential in pulmonary arterial hypertension. We aimed to elucidate whether native T1 values of the right ventricular free wall (RVT1) can predict poor outcomes in patients with pulmonary arterial hypertension. METHODS: This retrospective study included 30 patients with pulmonary arterial hypertension (median age, 45 years; mean pulmonary artery pressure, 41±13 mmHg) and 16 healthy controls (median age, 43 years) who underwent native T1 mapping. RVT1 was obtained from the inferior right ventricular free wall during end systole. RESULTS: Patients with pulmonary arterial hypertension had significantly higher native RVT1 than did controls (1384±74 vs. 1217±57 ms, p<0.001). Compared with T1 values of the septum or ventricular insertion points, RVT1 correlated better with the effective right ventricular elastance index (R = -0.53, p = 0.003), ventricular-arterial uncoupling (R = 0.46, p = 0.013), and serum brain natriuretic peptide levels (R = 0.65, p<0.001). Moreover, the baseline RVT1 was an accurate predictor of the reduced right ventricular ejection fraction at the 12-month follow-up (delta -3%). RVT1 was independently associated with composite events of death or hospitalization from any cause (hazard ratio = 1.02, p = 0.002). CONCLUSIONS: RVT1 was predictive of right ventricular performance and outcomes in patients with pulmonary arterial hypertension. Thus, native T1 mapping in the right ventricular free wall may be an effective prognostic method for pulmonary arterial hypertension.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Hipertensión Arterial Pulmonar/diagnóstico , Adulto , Anciano , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pronóstico , Hipertensión Arterial Pulmonar/diagnóstico por imagen , Hipertensión Arterial Pulmonar/fisiopatología , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Derecha
11.
SAGE Open Med Case Rep ; 9: 2050313X211046742, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34567556

RESUMEN

Uterine artery pseudoaneurysm is a rare cause of secondary postpartum hemorrhage. Herein, we report a case of uterine artery pseudoaneurysm, with postpartum hemorrhage commencing 22 days after uncomplicated vaginal delivery. Intermittent bleeding occurred during conservative observation. Transvaginal ultrasound color Doppler imaging revealed swollen vascular structures that suggested arteriovenous malformations, and a saccular dilatation of blood vessels. However, it was insufficient to definitively diagnose the condition as pseudoaneurysm. Meanwhile, the three-dimensional computed tomography angiogram was effective in demonstrating a pseudoaneurysm in the uterus, and an absent early venous return sign, leading to the final diagnosis of a pseudoaneurysm. The patient was successfully treated with transarterial embolization using gelatin sponge pledgets. No bleeding or recurrence of the pseudoaneurysm was observed 2 months after embolization.

12.
Ann Vasc Dis ; 14(1): 75-78, 2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33786106

RESUMEN

A 66-year-old man presented with an enlarging abdominal aorta false lumen, after type A aortic dissection repair. Residual entries were located at the left renal artery, abdominal aorta, and left external iliac artery. The patient underwent endovascular aortic repair with left renal artery stenting to close the entries. Completion aortography showed no false lumen flow without an endoleak, and contrast-enhanced computed tomography 1 month after the procedure demonstrated complete false lumen thrombosis. A total endovascular approach is possible for abdominal aneurysmal dilation in chronic aortic dissection when all entries can be closed using a one-stage procedure with stent grafts and/or branch stenting.

15.
Ann Vasc Dis ; 13(1): 72-75, 2020 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-32273926

RESUMEN

We report the case of a 83-year-old man with aneurysmal sac enlargement after endovascular aneurysm repair for an abdominal aortic aneurysm, despite no overt endoleak (EL) detected on imaging. Occult type II EL was suspected, and treatment was performed. However, the aneurysm continued to enlarge. Thus, we diagnose with type V EL as exclusion diagnosis. We combined an aortic cuff and stent-graft leg to cover the initially inserted stent graft, as a diagnostic treatment for unrefined type IIIb EL. Subsequently, the aneurysm diameter decreased. This technique and concept may be effective for type V EL, which may include another type occult EL.

16.
Ann Vasc Dis ; 13(3): 269-272, 2020 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-33384729

RESUMEN

Objective: To evaluate the clinical utility of the coil in plug (CIP) method in internal iliac artery (IIA) embolization during endovascular aortic aneurysm repair (EVAR) compared to conventional coil embolization (CCE). Material and Methods: From July to December 2018, 10 patients who underwent IIA embolization during EVAR were divided into CIP (n=5) and CCE (n=5) groups. In the CIP technique, the AVP-1 with a size more than 30%-50% of that of the embolized IIA diameter was used. The AVP-1 was deployed in the IIA. Before detachment of the AVP-1, a 2.2-F micro catheter was inserted through the 6-F delivery guiding sheath, and entered the plug. The AVP-1 was then packed with hydrogel micro coils. We compared number of coils used, embolization length, embolization time, volume embolization ratio, and embolic material cost between the groups. Results: The CIP method achieved shorter embolization length with fewer coils used compared to CCE. The CIP method decreased the cost of total embolic materials. Conclusion: The CIP method can achieve shorter embolization length with fewer coils used compared to CCE.

18.
Cardiovasc Intervent Radiol ; 42(10): 1488-1493, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31363897

RESUMEN

PURPOSE: We presented a new method of sac embolization using n-butyl-cyanoacrylate (NBCA) with balloon occlusion of the aorta (SEBOA) that can facilitate decreasing flow rate of the involved branches with the goal of type 2 endoleak resolution after endovascular aortic repair (EVAR). TECHNIQUE: This technique is demonstrated in six patients who required type 2 endoleak treatment including previous technical failure. A transarterial approach was performed in four patients and transabdominal direct puncture in two. Technical success was defined as complete embolization of both involved branches and sac on postoperative CT. Sacography under balloon occlusion of the aorta demonstrated decreased flow rate of the all involved branches in all patients. SEBOA was performed using 25 or 33% of NBCA diluted with lipiodol. Technical success was obtained in 3 of 6 patients, and one major complication was observed with adhesion of NBCA to the microcatheter resulting in foreign body retention. CONCLUSION: SEBOA may help solve the difficulty of type 2 endoleak treatment after EVAR as decreased flow rate of the involved branches under balloon occlusion of the aorta was achieved in all patients. However, protocols regarding concentration of NBCA or using other embolic materials are needed to improve the success rate.


Asunto(s)
Aneurisma de la Aorta/terapia , Oclusión con Balón/métodos , Embolización Terapéutica/métodos , Endofuga/terapia , Procedimientos Endovasculares/métodos , Anciano , Aorta/diagnóstico por imagen , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico por imagen , Enbucrilato/administración & dosificación , Endofuga/complicaciones , Endofuga/diagnóstico por imagen , Aceite Etiodizado/administración & dosificación , Femenino , Humanos , Masculino , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
Cardiovasc Intervent Radiol ; 42(10): 1483-1487, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31254039

RESUMEN

BACKGROUND: Endovascular treatment of infrarenal abdominal aortic aneurysm (AAA) with proximal chronic aortic dissection is challenging as a false and true lumen at the level of the infra-renal neck does not allow a sufficient landing zone. We describe staged endovascular neck stabilization prior to standard endovascular aortic repair (EVAR) for AAA with chronic aortic dissection. TECHNIQUE: To create a stable proximal neck (PN) by closing entry tears, thereby resulting in total false lumen thrombosis (FLT) prior to standard EVAR. Case 1 false lumen fenestrations were present at the descending aorta, the right renal artery orifice and PN. After closing the entry tear by thoracic EVAR, an aortic cuff was placed in the true lumen of the PN and renal stenting for the right renal artery was performed. After 2 months, total FLT was achieved, and EVAR was performed. Case 2 false lumen fenestrations were present at the descending, super celiac aorta and PN. After closing the entry by TEVAR, aortic cuffs were placed at infrarenal aorta to close residual entries. After 1 month of achieving total FLT, EVAR was performed. Both cases had no type 1 endoleak during follow-up. CONCLUSION: The endovascular neck stabilization is a useful treatment option that facilitates standard EVAR for AAA in chronic aortic dissection.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Anciano , Aorta Abdominal/cirugía , Enfermedad Crónica , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
20.
Neuroradiology ; 61(3): 305-311, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30465057

RESUMEN

PURPOSE: The reliability of assessment of the artery of Adamkiewicz before the aortic repair is highly dependent on the display of the continuity of this artery with the aorta, mainly around the vertebral pedicle, by computed tomography angiography (CTA). We hypothesized that the sharp filter kernel can improve visualization of this continuity of the vessel structure because of its edge enhancement and high-spatial resolution. This study was performed to compare the subjective and objective image quality of spinal CTA reconstructed with sharp and smooth filter kernels. METHODS: We retrospectively reviewed 40 consecutive patients who had undergone 80-kV CTA to detect the artery of Adamkiewicz before aortic repair. We measured the CT number and the contrast-to-noise ratio of the anterior spinal artery to the spinal cord. Furthermore, the continuity of the artery of Adamkiewicz was evaluated using a 3-point scale (2 points, absolute; 0 points, undetectable). RESULTS: CTA with the sharp filter kernel showed a significantly higher CT number and contrast-to-noise ratio of the spinal artery than did CTA with the smooth filter kernel (P < .001 for both). Moreover, the sharp filter kernel showed a significantly higher continuity of the artery of Adamkiewicz with the aorta than did the smooth filter kernel (P < .001). CONCLUSIONS: The sharp filter kernel significantly improved the image quality in low-tube-voltage CTA for the assessment of the artery of Adamkiewicz. Thus, CTA with the sharp filter kernel can generate a high-confidence level in the evaluation of the artery of Adamkiewicz.


Asunto(s)
Arterias/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Aorta/cirugía , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...