Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 97(3): E327-E332, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32583944

RESUMEN

OBJECTIVES: This study was conducted to evaluate the association of geographic distance with robotic telestenting performance by comparing performance measures in transcontinental and regional pre-clinical models of telestenting. BACKGROUND: Robotic telestenting, in which percutaneous coronary intervention (PCI) is performed on a remotely located patient, might improve PCI access, but has not been attempted over vast distances likely required to reach many underserved regions. METHODS: Telestenting performance was compared in regional (Boston to New York [206 miles]) and transcontinental (Boston to San Francisco [3,085 miles]) ex vivo models of telestenting, wherein a physician in Boston attempted robotic PCI on endovascular simulators in New York and San Francisco, respectively. PCI was attempted over both wired and fifth generation (5G)-wireless networks. Outcome measures included procedural success, procedural time, and perceived latency. RESULTS: Procedural success was achieved in 20 consecutive target lesions in the regional model and in 16 consecutive target lesions in the transcontinental model. The transcontinental model had a greater latency than the regional model over both wired (121.5 ± 2.4 ms vs. 67.8 ± 0.9 ms; p < .001) and 5G-wireless networks (162.5 ± 1.1 ms vs. 86.6 ± 0.6 ms; p < .001), but perceived latencies were graded "imperceptible" in all cases in both models. Transcontinental and regional models did not have significantly different procedural times over wired (4.1 ± 1.9 min vs. 9.0 ± 7.1 min; p = .051) or 5G-wireless (3.0 ± 0.6 vs. 6.3 ± 1.2; p = .36) networks. CONCLUSIONS: Transcontinental robotic manipulation of coronary devices is now possible and was not associated with adverse performance compared to robotic telestenting conducted regionally.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Robotizados , Angiografía Coronaria , Humanos , Intervención Coronaria Percutánea/efectos adversos , Stents , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 97(3): E274-E279, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32442332

RESUMEN

OBJECTIVES: The purpose of this study was to explore the feasibility and safety of robotic PCI performed using an off-siteremote-control system in an animal model. BACKGROUND: Access to primary percutaneous coronary intervention (PCI) remains a challenge in acute myocardial infarction management. The combination of telemedicine and robotic PCI allow the potential delivery of primary PCI to remote locations without the delay of transfer. METHODS: This single-center prospective pilot preclinical feasibility study compared robotic PCI with remote PCI on swine across three stages (adjacent room, different floor of the same building, two different buildings). Latency up to 1,000 ms was introduced into the operating environment to simulate decreased network quality (blinded to operator). The primary outcome measures were technical success and acute safety. The secondary outcome measures included lesion wiring time, procedural time and qualitative scoring of the PCI experience by the operator. RESULTS: Across 52 experiments in 15 animals, technical success was 100%. No procedural complications occurred during the study. No significant difference in lesion treatment time was detected between stages (p = .11) and between time per target vessel when latency up to 1,000 ms was introduced (p = .58). Injected delay >250 ms had the greatest impact on procedure perceived lag. Longer procedure time was associated with lower procedure impact score, regardless of injected latency. CONCLUSIONS: Remote robotic PCI was feasible and safe in an animal model. Procedural duration was acceptable and unaffected by network latency. Future studies are needed to determine the safety and feasibility of remote PCI in humans.


Asunto(s)
Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Robotizados , Animales , Estudios de Factibilidad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Porcinos , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 95(5): 914-919, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31410958

RESUMEN

OBJECTIVE: This study evaluated the impact of network latency on telestenting performance. BACKGROUND: The feasibility of long-distance robotic telestenting was recently demonstrated, yet the impact of network performance on telestenting remains unknown. METHODS: Ex vivo and in vivo telestenting models were constructed by connecting a robotic drive over a wired network to a robotic control system up to 103 miles away. During consecutive attempts to robotically wire a coronary artery, investigators randomly added signal latencies from 0 to 1,000 ms. Outcomes included wiring success, wiring time (time to advance wire to preselected target landmark), and perceived latency score (5 = imperceptible; 4 = noticeable but minor; 3 = noticeable; 2 = noticeable and major; 1 = unacceptable). RESULTS: Wiring success was achieved in 95 of 95 attempts in the ex vivo model and in 57 of 57 attempts in vivo. No significant difference in wiring time was observed across added latencies from 0 to 1,000 ms in the ex vivo (p = .64) or in vivo (p = .40) models. Compared to an added latency of 0 ms, perceived latency scores were not significantly different for added latencies of 150 and 250 ms (p = NS for both), but were significantly lower for latencies ≥400 ms (p < .001). CONCLUSIONS: Added latencies up to 250 ms were not associated with perceived latency, but latencies ≥400 ms were perceptible. Based on these findings, future telestenting studies should utilize networks with latencies ≤250 ms if perceived latency is to be avoided.


Asunto(s)
Redes de Comunicación de Computadores , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Consulta Remota/instrumentación , Robótica/instrumentación , Stents , Terapia Asistida por Computador/instrumentación , Animales , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Maniquíes , Modelos Animales , Intervención Coronaria Percutánea/efectos adversos , Sus scrofa , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA