Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Arthroplasty ; 38(7S): S252-S256, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37075906

RESUMEN

BACKGROUND: Accurate acetabular component positioning is paramount to the success of total hip arthroplasty (THA). Two-dimensional imaging alone remains a popular tool for implant position assessment despite known limitations. We investigated the accuracy of a novel method for assessing acetabular component position based upon orthogonal simultaneous biplanar X-ray images. METHODS: There were forty consecutive patients who had a preexisting THA on the contralateral side who underwent both computed tomography (CT) and simultaneous orthogonal biplanar radiographic scans for preoperative planning of THA. The operative inclination (OI) and operative anteversion (OA) of the acetabular cup were calculated by a new measurement method using the biplanar simultaneous scans. Those measurements were compared to measurement of the cup orientation on CT. The measurements were made by 2 independent observers. Interobserver correlation coefficients were calculated between the 2 observers to measure reliability. RESULTS: The mean error in OA measurement of the acetabular cup between simultaneous orthogonal biplanar radiographic and CT imaging was 0.5° (SD: 1.9°, minimum -4.0°, maximum 5.0°), the mean error in OI was 0.0° (SD: 1.7°, minimum -5.0°, maximum 4.0°). The average absolute error was 1.5° for OA and 1.2° for OI. Interobserver correlation coefficient was 0.83 for OA and 0.93 for OI. CONCLUSION: The novel method of measuring cup orientation using simultaneous biplanar radiographic scans utilized in this study was accurate and reproducible between observers compared to CT measurements.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Reproducibilidad de los Resultados , Artroplastia de Reemplazo de Cadera/métodos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Tomografía Computarizada por Rayos X/métodos
2.
Acta Ophthalmol ; 97(5): e719-e728, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30839157

RESUMEN

PURPOSE: A retrospective pilot study is conducted to demonstrate the utility of a novel support vector machine learning (SVML) algorithm in a small three-dimensional (3D) sample yielding sparse optical coherence tomography (spOCT) data for the automatic monitoring of neovascular (wet) age-related macular degeneration (wAMD). METHODS: From the anti-vascular endothelial growth factor injection database, 588 consecutive pairs of OCT volumes (57.624 B-scans) were selected in 70 randomly chosen wAMD patients treated with ranibizumab. The SVML algorithm was applied to 183 OCT volume pairs (17.934 B-scans) in 30 patients. Four independent, diagnosis-blinded retina specialists indicated whether wAMD activity was present between 100 pairs of consecutive OCT volumes (9800 B-scans) in the remaining 40 patients for comparison with the SVML algorithm and a non-complex baseline algorithm using only retinal thickness. The SVML algorithm was assessed using inter-observer variability and receiver operating characteristic (ROC) analyses. RESULTS: The retina specialists showed an average Cohen's κ of 0.57 ± 0.13 (minimum: 0.41, maximum: 0.83). The average κ between the proposed algorithm and the retina specialists was 0.62 ± 0.05 and 0.43 ± 0.14 between the baseline algorithm and the retina specialists. Using each of the four retina specialists as the reference, the proposed method showed a superior area under the ROC curve of 0.91 ± 0.03 compared to the ROC 0.81 ± 0.05 shown by the baseline algorithm. CONCLUSION: The SVML algorithm was as effective as the retina specialists were in detecting activity in wAMD. Support vector machine learning (SVML) may be a useful monitoring tool in wAMD suited for small samples that yield sparse OCT data possibly derived from self-measuring OCT-robots.


Asunto(s)
Algoritmos , Mácula Lútea/diagnóstico por imagen , Máquina de Vectores de Soporte , Tomografía de Coherencia Óptica/métodos , Degeneración Macular Húmeda/diagnóstico , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Proyectos Piloto , Pronóstico , Curva ROC , Estudios Retrospectivos , Factores de Tiempo
3.
Clin Orthop Relat Res ; 476(2): 325-335, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29529664

RESUMEN

BACKGROUND: Cup malposition is a common cause of impingement, limitation of ROM, acceleration of bearing wear, liner fracture, and instability in THA. Previous studies of the safe zone based on plain radiographs have limitations inherent to measuring angles from two-dimensional projections. The current study uses CT to measure component position in stable and unstable hips to assess the presence of a safe zone for cup position in THA. QUESTIONS/PURPOSES: (1) Does acetabular component orientation, when measured on CT, differ in stable components and those revised for recurrent instability? (2) Do CT data support historic safe zone definitions for component orientation in THA? METHODS: We identified 34 hips that had undergone revision of the acetabulum for recurrent instability that also had a CT scan of the pelvis between August 2003 and February 2017. We also identified 175 patients with stable hip replacements who also had a CT study for preoperative planning and intraoperative navigation of the contralateral side. For each CT study, one observer analyzed major factors including acetabular orientation, femoral anteversion, combined anteversion (the sum of femoral and anatomic anteversion), pelvic tilt, total offset difference, head diameter, age, sex, and body mass index. These measures were then compared among stable hips, hips with cup revision for anterior instability, and hips with cup revision for posterior instability. We used a clinically relevant measurement of operative anteversion and inclination as opposed to the historic use of radiographic anteversion and inclination. The percentage of unstable hips in the historic Lewinnek safe zone was calculated, and a new safe zone was proposed based on an area with no unstable hips. RESULTS: Anteriorly unstable hips compared with stable hips had higher operative anteversion of the cup (44° ± 12° versus 31° ± 11°, respectively; mean difference, 13°; 95% confidence interval [CI], 5°-21°; p = 0.003), tilt-adjusted operative anteversion of the cup (40° ± 6° versus 26° ± 10°, respectively; mean difference, 14°; 95% CI, 10°-18°; p < 0.001), and combined tilt-adjusted anteversion of the cup (64° ± 10° versus 54° ± 19°, respectively; mean difference, 10°; 95% CI, 1°-19°; p = 0.028). Posteriorly unstable hips compared with stable hips had lower operative anteversion of the cup (19° ± 15° versus 31° ± 11°, respectively; mean difference, -12°; 95% CI, -5° to -18°; p = 0.001), tilt-adjusted operative anteversion of the cup (19° ± 13° versus 26° ± 10°, respectively; mean difference, -8°; 95% CI, -14° to -2°; p = 0.014), pelvic tilt (0° ± 6° versus 4° ± 6°, respectively; mean difference, -4°; 95% CI, -7° to -1°; p = 0.007), and anatomic cup anteversion (25° ± 18° versus 34° ± 12°, respectively; mean difference, -9°; 95% CI, -1° to -17°; p = 0.033). Thirty-two percent of the unstable hips were located in the Lewinnek safe zone (11 of 34; 10 posterior dislocations, one anterior dislocation). In addition, a safe zone with no unstable hips was identified within 43° ± 12° of operative inclination and 31° ± 8° of tilt-adjusted operative anteversion. CONCLUSIONS: The current study supports the notion of a safe zone for acetabular component orientation based on CT. However, the results demonstrate that the historic Lewinnek safe zone is not a reliable predictor of future stability. Analysis of tilt-adjusted operative anteversion and operative inclination demonstrates a new safe zone where no hips were revised for recurrent instability that is narrower for tilt-adjusted operative anteversion than for operative inclination. Tilt-adjusted operative anteversion is significantly different between stable and unstable hips, and surgeons should therefore prioritize assessment of preoperative pelvic tilt and accurate placement in operative anteversion. With improvements in patient-specific cup orientation goals and acetabular component placement, further refinement of a safe zone with CT data may reduce the incidence of cup malposition and its associated complications. LEVEL OF EVIDENCE: Level III, diagnostic study.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Luxación de la Cadera/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Inestabilidad de la Articulación/cirugía , Falla de Prótesis , Acetábulo/diagnóstico por imagen , Acetábulo/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/etiología , Luxación de la Cadera/fisiopatología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/fisiopatología , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Diseño de Prótesis , Rango del Movimiento Articular , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Invest Ophthalmol Vis Sci ; 56(11): 6654-62, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26567781

RESUMEN

PURPOSE: Selective retina therapy (SRT) is a novel treatment for retinal pathologies, solely targeting the RPE. During SRT, the detection of an immediate tissue reaction is challenging, as tissue effects remain limited to intracellular RPE photodisruption. Time-resolved ultra-high axial resolution optical coherence tomography (OCT) is thus evaluated for the monitoring of dynamic optical changes at and around the RPE during SRT. METHODS: An experimental OCT system with an ultra-high axial resolution of 1.78 µm was combined with an SRT system and time-resolved OCT M-scans of the target area were recorded from four patients undergoing SRT. Optical coherence tomography scans were analyzed and OCT morphology was correlated with findings in fluorescein angiography, fundus photography, and cross-sectional OCT. RESULTS: In cases in which the irradiation caused RPE damage proven by fluorescein angiography, the lesions were well discernible in time-resolved OCT images but remained invisible in fundus photography and cross-sectional OCT acquired after treatment. If RPE damage was introduced, all applied SRT pulses led to detectable signal changes in the time-resolved OCT images. The extent of optical signal variation seen in the OCT data appeared to scale with the applied SRT pulse energy. CONCLUSIONS: The first clinical results proved that successful SRT irradiation induces detectable changes in the OCT M-scan signal while it remains invisible in conventional ophthalmoscopic imaging. Thus, real-time high-resolution OCT is a promising modality to monitor and analyze tissue effects introduced by selective retina therapy and may be used to guide SRT in an automatic feedback mode (www.swissmedic.ch number, 2011-MD-0006).


Asunto(s)
Terapia por Láser , Enfermedades de la Retina/diagnóstico , Enfermedades de la Retina/cirugía , Epitelio Pigmentado de la Retina/efectos de la radiación , Tomografía de Coherencia Óptica/métodos , Adulto , Femenino , Humanos , Terapia por Láser/efectos adversos , Terapia por Láser/métodos , Masculino
5.
Ophthalmologica ; 234(4): 177-88, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26368551

RESUMEN

PURPOSE: Selective retina therapy (SRT), the confined laser heating and destruction of retinal pigment epithelial cells, has been shown to treat acute types of central serous chorioretinopathy (CSC) successfully without damaging the photoreceptors and thus avoiding laser-induced scotoma. However, a benefit of laser treatment for chronic forms of CSC is questionable. In this study, the efficacy of SRT by means of the previously used 1.7-µs and shorter 300-ns pulse duration was evaluated for both types of CSC, also considering re-treatment for nonresponders. MATERIAL AND METHODS: In a two-center trial, 26 patients were treated with SRT for acute (n = 10) and chronic-recurrent CSC (n = 16). All patients presented with subretinal fluid (SRF) in OCT and leakage in fluorescein angiography (FA). SRT was performed using a prototype SRT laser system (frequency-doubled Q-switched Nd:YLF-laser, wavelength 527 nm) with adjustable pulse duration. The following irradiation settings were used: a train of 30 laser pulses with a repetition rate of 100 Hz and pulse durations of 300 ns and 1.7 µs, pulse energy 120-200 µJ, retinal spot size 200 µm. Because SRT lesions are invisible, FA was always performed 1 h after treatment to demonstrate laser outcome (5-8 single spots in the area of leakage). In cases where energy was too low, as indicated by missing FA leakage, energy was adjusted and the patient re-treated immediately. Observation intervals were after 4 weeks and 3 months. In case of nonimprovement of the disease after 3 months, re-treatment was considered. RESULTS: Of 10 patients with active CSC that presents focal leakage in FA, 5 had completely resolved fluid after 4 weeks and all 10 after 3 months. Mean visual acuity increased from 76.6 ETDRS letters to 85.0 ETDRS letters 3 months after SRT. Chronic-recurrent CSC was characterized by less severe SRF at baseline in OCT and weaker leakage in FA than in acute types. Visual acuity changed from baseline 71.6 to 72.8 ETDRS letters after 3 months. At this time, SRF was absent in 3 out of 16 patients (19%), FA leakage had come to a complete stop in 6 out of 16 patients (38%). In 6 of the remaining chronic CSC patients, repeated SRT with higher pulse energy was considered because of persistent leakage activity. After the re-treatment, SRF resolved completely in 5 patients (83.3%) after only 25 days. CONCLUSION: SRT showed promising results in treating acute CSC, but was less effective in chronic cases. Interestingly, re-treatment resulted in enhanced fluid resolution and dry conditions after a considerably shorter time in most patients. Therefore, SRT including re-treatment if necessary might be a valuable CSC treatment alternative even in chronic-recurrent cases.


Asunto(s)
Coriorretinopatía Serosa Central/cirugía , Coagulación con Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Enfermedad Aguda , Adulto , Barrera Hematorretinal , Permeabilidad Capilar , Coriorretinopatía Serosa Central/diagnóstico , Coriorretinopatía Serosa Central/fisiopatología , Enfermedad Crónica , Angiografía con Fluoresceína , Humanos , Persona de Mediana Edad , Líquido Subretiniano , Tomografía de Coherencia Óptica , Agudeza Visual/fisiología
6.
Int J Radiat Oncol Biol Phys ; 92(4): 794-802, 2015 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-26104933

RESUMEN

PURPOSE: Proper delineation of ocular anatomy in 3-dimensional (3D) imaging is a big challenge, particularly when developing treatment plans for ocular diseases. Magnetic resonance imaging (MRI) is presently used in clinical practice for diagnosis confirmation and treatment planning for treatment of retinoblastoma in infants, where it serves as a source of information, complementary to the fundus or ultrasonographic imaging. Here we present a framework to fully automatically segment the eye anatomy for MRI based on 3D active shape models (ASM), and we validate the results and present a proof of concept to automatically segment pathological eyes. METHODS AND MATERIALS: Manual and automatic segmentation were performed in 24 images of healthy children's eyes (3.29 ± 2.15 years of age). Imaging was performed using a 3-T MRI scanner. The ASM consists of the lens, the vitreous humor, the sclera, and the cornea. The model was fitted by first automatically detecting the position of the eye center, the lens, and the optic nerve, and then aligning the model and fitting it to the patient. We validated our segmentation method by using a leave-one-out cross-validation. The segmentation results were evaluated by measuring the overlap, using the Dice similarity coefficient (DSC) and the mean distance error. RESULTS: We obtained a DSC of 94.90 ± 2.12% for the sclera and the cornea, 94.72 ± 1.89% for the vitreous humor, and 85.16 ± 4.91% for the lens. The mean distance error was 0.26 ± 0.09 mm. The entire process took 14 seconds on average per eye. CONCLUSION: We provide a reliable and accurate tool that enables clinicians to automatically segment the sclera, the cornea, the vitreous humor, and the lens, using MRI. We additionally present a proof of concept for fully automatically segmenting eye pathology. This tool reduces the time needed for eye shape delineation and thus can help clinicians when planning eye treatment and confirming the extent of the tumor.


Asunto(s)
Puntos Anatómicos de Referencia/anatomía & histología , Ojo/anatomía & histología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Retina/radioterapia , Retinoblastoma/radioterapia , Niño , Preescolar , Córnea/anatomía & histología , Humanos , Lactante , Cristalino/anatomía & histología , Disco Óptico/anatomía & histología , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Retina/patología , Retinoblastoma/patología , Esclerótica/anatomía & histología , Cuerpo Vítreo/anatomía & histología
7.
IEEE Trans Biomed Eng ; 62(2): 532-40, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25265602

RESUMEN

Ophthalmologists typically acquire different image modalities to diagnose eye pathologies. They comprise, e.g., Fundus photography, optical coherence tomography, computed tomography, and magnetic resonance imaging (MRI). Yet, these images are often complementary and do express the same pathologies in a different way. Some pathologies are only visible in a particular modality. Thus, it is beneficial for the ophthalmologist to have these modalities fused into a single patient-specific model. The goal of this paper is a fusion of Fundus photography with segmented MRI volumes. This adds information to MRI that was not visible before like vessels and the macula. This paper contributions include automatic detection of the optic disc, the fovea, the optic axis, and an automatic segmentation of the vitreous humor of the eye.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Neoplasias de la Retina/patología , Retinoblastoma/patología , Retinoscopía/métodos , Técnica de Sustracción , Adolescente , Puntos Anatómicos de Referencia , Simulación por Computador , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Modelos Biológicos , Modelación Específica para el Paciente , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Invest Ophthalmol Vis Sci ; 55(10): 6575-9, 2014 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-25190655

RESUMEN

PURPOSE: Optical coherence tomography (OCT) was used to analyze the thickness of various retinal layers of patients following successful macula-off retinal detachment (RD) repair. METHODS: Optical coherence tomography scans of patients after successful macula-off RD repair were reanalyzed with a subsegmentation algorithm to measure various retinal layers. Regression analysis was performed to correlate time after surgery with changes in layer thickness. In addition, patients were divided in two groups. Group 1 had a follow-up period after surgery of up to 7 weeks (range, 21-49 days). In group 2, the follow-up period was >8 weeks (range, 60-438 days). Findings were compared to a group of age-matched healthy controls. RESULTS: Correlation analysis showed a significant positive correlation between inner nuclear-outer plexiform layer (INL-OPL) thickness and time after surgery (P=0.0212; r2=0.1551). Similar results were found for the ellipsoid zone-retinal pigment epithelium complex (EZ-RPE) thickness (P=0.005; r2=0.2215). Ganglion cell-inner plexiform layer thickness (GCL-IPL) was negatively correlated with time after surgery (P=0.0064; r2=0.2101). For group comparison, the retinal nerve fiber layer in both groups was thicker compared to controls. The GCL-IPL showed significant thinning in group 2. The outer nuclear layer was significantly thinner in groups 1 and 2 compared to controls. The EZ-RPE complex was significantly thinner in groups 1 and 2 compared to controls. In addition, values in group 1 were significantly thinner than in group 2. CONCLUSIONS: Optical coherence tomography retinal layer thickness measurements after successful macular-off RD repair revealed time-dependent thickness changes. Inner nuclear-outer plexiform layer thickness and EZ-RPE thickness was positively correlated with time after surgery. Ganglion cell-inner plexiform layer thickness was negatively correlated with time after surgery.


Asunto(s)
Desprendimiento de Retina/diagnóstico , Células Ganglionares de la Retina/patología , Cirugía Asistida por Computador/métodos , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos , Femenino , Estudios de Seguimiento , Humanos , Mácula Lútea/patología , Mácula Lútea/cirugía , Masculino , Persona de Mediana Edad , Desprendimiento de Retina/cirugía , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
9.
Med Phys ; 41(8): 081704, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25086514

RESUMEN

PURPOSE: External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). METHODS: A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. RESULTS: Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. CONCLUSIONS: The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.


Asunto(s)
Neoplasias del Ojo/patología , Neoplasias del Ojo/radioterapia , Ojo/patología , Radioterapia Guiada por Imagen/métodos , Tomografía de Coherencia Óptica/métodos , Animales , Calibración , Diseño de Equipo , Enucleación del Ojo , Modelos Biológicos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/instrumentación , Porcinos , Tomografía de Coherencia Óptica/instrumentación
10.
Invest Ophthalmol Vis Sci ; 55(4): 2106-13, 2014 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-24569585

RESUMEN

PURPOSE: Fundus autofluorescence (FAF) cannot only be characterized by the intensity or the emission spectrum, but also by its lifetime. As the lifetime of a fluorescent molecule is sensitive to its local microenvironment, this technique may provide more information than fundus autofluorescence imaging. We report here the characteristics and repeatability of FAF lifetime measurements of the human macula using a new fluorescence lifetime imaging ophthalmoscope (FLIO). METHODS: A total of 31 healthy phakic subjects were included in this study with an age range from 22 to 61 years. For image acquisition, a fluorescence lifetime ophthalmoscope based on a Heidelberg Engineering Spectralis system was used. Fluorescence lifetime maps of the retina were recorded in a short- (498-560 nm) and a long- (560-720 nm) spectral channel. For quantification of fluorescence lifetimes a standard ETDRS grid was used. RESULTS: Mean fluorescence lifetimes were shortest in the fovea, with 208 picoseconds for the short-spectral channel and 239 picoseconds for the long-spectral channel, respectively. Fluorescence lifetimes increased from the central area to the outer ring of the ETDRS grid. The test-retest reliability of FLIO was very high for all ETDRS areas (Spearman's ρ = 0.80 for the short- and 0.97 for the long-spectral channel, P < 0.0001). Fluorescence lifetimes increased with age. CONCLUSIONS: The FLIO allows reproducible measurements of fluorescence lifetimes of the macula in healthy subjects. By using a custom-built software, we were able to quantify fluorescence lifetimes within the ETDRS grid. Establishing a clinically accessible standard against which to measure FAF lifetimes within the retina is a prerequisite for future studies in retinal disease.


Asunto(s)
Angiografía con Fluoresceína/métodos , Mácula Lútea/citología , Oftalmoscopios , Oftalmoscopía/métodos , Adulto , Femenino , Estudios de Seguimiento , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Agudeza Visual , Adulto Joven
11.
Ophthalmology ; 121(1): 142-149, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24139122

RESUMEN

PURPOSE: To investigate retrograde axonal degeneration for its potential to cause microcystic macular edema (MME), a maculopathy that has been previously described in patients with demyelinating disease. To identify risk factors for MME and to expand the anatomic knowledge on MME. DESIGN: Retrospective case series. PARTICIPANTS: We included 117 consecutive patients and 180 eyes with confirmed optic neuropathy of variable etiology. Patients with glaucoma were excluded. METHODS: We determined age, sex, visual acuity, etiology of optic neuropathy, and the temporal and spatial characteristics of MME. Eyes with MME were compared with eyes with optic neuropathy alone and to healthy fellow eyes. With retinal layer segmentation we quantitatively measured the intraretinal anatomy. MAIN OUTCOME MEASURES: Demographic data, distribution of MME in the retina, and thickness of retinal layers were analyzed. RESULTS: We found MME in 16 eyes (8.8%) from 9 patients, none of whom had multiple sclerosis or neuromyelitis optica. The MME was restricted to the inner nuclear layer (INL) and had a characteristic perifoveal circular distribution. Compared with healthy controls, MME was associated with significant thinning of the ganglion cell layer and nerve fiber layer, as well as a thickening of the INL and the deeper retinal layers. Youth is a significant risk factor for MME. CONCLUSIONS: Microcystic macular edema is not specific for demyelinating disease. It is a sign of optic neuropathy irrespective of its etiology. The distinctive intraretinal anatomy suggests that MME is caused by retrograde degeneration of the inner retinal layers, resulting in impaired fluid resorption in the macula.


Asunto(s)
Axones/patología , Edema Macular/etiología , Enfermedades del Nervio Óptico/complicaciones , Femenino , Humanos , Edema Macular/diagnóstico , Imagen por Resonancia Magnética , Masculino , Degeneración Nerviosa/patología , Células Ganglionares de la Retina/patología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía de Coherencia Óptica , Agudeza Visual/fisiología
12.
IEEE Trans Med Imaging ; 32(3): 531-43, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23086520

RESUMEN

Optical coherence tomography (OCT) is a well-established image modality in ophthalmology and used daily in the clinic. Automatic evaluation of such datasets requires an accurate segmentation of the retinal cell layers. However, due to the naturally low signal to noise ratio and the resulting bad image quality, this task remains challenging. We propose an automatic graph-based multi-surface segmentation algorithm that internally uses soft constraints to add prior information from a learned model. This improves the accuracy of the segmentation and increase the robustness to noise. Furthermore, we show that the graph size can be greatly reduced by applying a smart segmentation scheme. This allows the segmentation to be computed in seconds instead of minutes, without deteriorating the segmentation accuracy, making it ideal for a clinical setup. An extensive evaluation on 20 OCT datasets of healthy eyes was performed and showed a mean unsigned segmentation error of 3.05 ±0.54 µm over all datasets when compared to the average observer, which is lower than the inter-observer variability. Similar performance was measured for the task of drusen segmentation, demonstrating the usefulness of using soft constraints as a tool to deal with pathologies.


Asunto(s)
Algoritmos , Técnicas de Diagnóstico Oftalmológico , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Biológicos , Tomografía de Coherencia Óptica/métodos , Bases de Datos Factuales , Humanos , Degeneración Macular/patología , Modelos Estadísticos , Retina/anatomía & histología , Retina/patología , Drusas Retinianas/patología
13.
Int J Radiat Oncol Biol Phys ; 84(4): e541-7, 2012 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22867896

RESUMEN

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95%±2% for the sclera and cornea and 91%±2% for the lens. Overall, mean segmentation error was found to be 0.3±0.1 mm. Average segmentation time was 14±2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.


Asunto(s)
Simulación por Computador , Neoplasias del Ojo/radioterapia , Ojo/anatomía & histología , Modelos Biológicos , Planificación de la Radioterapia Asistida por Computador/métodos , Adulto , Anciano , Córnea/diagnóstico por imagen , Ojo/diagnóstico por imagen , Neoplasias del Ojo/diagnóstico por imagen , Femenino , Humanos , Cristalino/diagnóstico por imagen , Masculino , Ilustración Médica , Persona de Mediana Edad , Modelos Estadísticos , Disco Óptico/diagnóstico por imagen , Órganos en Riesgo/diagnóstico por imagen , Reproducibilidad de los Resultados , Esclerótica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
14.
Med Image Comput Comput Assist Interv ; 15(Pt 3): 599-606, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23286180

RESUMEN

With improvements in acquisition speed and quality, the amount of medical image data to be screened by clinicians is starting to become challenging in the daily clinical practice. To quickly visualize and find abnormalities in medical images, we propose a new method combining segmentation algorithms with statistical shape models. A statistical shape model built from a healthy population will have a close fit in healthy regions. The model will however not fit to morphological abnormalities often present in the areas of pathologies. Using the residual fitting error of the statistical shape model, pathologies can be visualized very quickly. This idea is applied to finding drusen in the retinal pigment epithelium (RPE) of optical coherence tomography (OCT) volumes. A segmentation technique able to accurately segment drusen in patients with age-related macular degeneration (AMD) is applied. The segmentation is then analyzed with a statistical shape model to visualize potentially pathological areas. An extensive evaluation is performed to validate the segmentation algorithm, as well as the quality and sensitivity of the hinting system. Most of the drusen with a height of 85.5 microm were detected, and all drusen at least 93.6 microm high were detected.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Modelos Biológicos , Drusas del Disco Óptico/patología , Reconocimiento de Normas Patrones Automatizadas/métodos , Tomografía de Coherencia Óptica/métodos , Inteligencia Artificial , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Modelos Estadísticos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Int J Radiat Oncol Biol Phys ; 82(4): 1361-6, 2012 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-21665382

RESUMEN

PURPOSE: External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described. METHODS AND MATERIALS: A navigated reference base was attached noninvasively to the eye, and a navigated pointer device was used to record the spatial position of the tantalum markers, the tumor, and anatomical landmarks. Measurement accuracy was assessed on ex vivo porcine eye specimen by repetitive recording of the tantalum marker positions. The method was applied intraoperatively on 4 patients undergoing routine tantalum clip surgery. The spatial position information delivered by the navigation system was compared to the geometric data generated by the EYEPLAN software. RESULTS: In the ex vivo experiments, the maximum repetition error was 0.34 mm. For the intraoperative application, the root mean square error of paired-points matching of the marker positions from the navigation system and from the EYEPLAN software was 0.701-1.25 mm. CONCLUSIONS: Navigation systems are a feasible tool for accurate localization of tantalum markers and anatomic landmarks. They can provide additional geometric information, and therefore have the potential to increase the reliability and accuracy of external beam proton radiation therapy for choroidal melanoma.


Asunto(s)
Neoplasias de la Coroides/radioterapia , Marcadores Fiduciales , Melanoma/radioterapia , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Tecnología de Sensores Remotos/métodos , Tantalio , Neoplasias de la Úvea/radioterapia , Animales , Humanos , Tratamientos Conservadores del Órgano/instrumentación , Tratamientos Conservadores del Órgano/métodos , Proyectos Piloto , Tecnología de Sensores Remotos/instrumentación , Esclerótica , Porcinos
16.
IEEE Trans Biomed Eng ; 58(10): 2816-24, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21689999

RESUMEN

An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 µm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Fotocoagulación/métodos , Retina/anatomía & histología , Vasos Retinianos/anatomía & histología , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Grabación en Video
17.
Comput Biol Med ; 41(5): 285-91, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21463859

RESUMEN

An automated algorithm for detection of the acetabular rim was developed. Accuracy of the algorithm was validated in a sawbone study and compared against manually conducted digitization attempts, which were established as the ground truth. The latter proved to be reliable and reproducible, demonstrated by almost perfect intra- and interobserver reliability. Validation of the automated algorithm showed no significant difference compared to the manually acquired data in terms of detected version and inclination. Automated detection of the acetabular rim contour and the spatial orientation of the acetabular opening plane can be accurately achieved with this algorithm.


Asunto(s)
Acetábulo/diagnóstico por imagen , Huesos Pélvicos/diagnóstico por imagen , Pelvis/diagnóstico por imagen , Acetábulo/patología , Algoritmos , Automatización , Diagnóstico por Imagen/métodos , Articulación de la Cadera/anatomía & histología , Articulación de la Cadera/patología , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Rayos Láser , Informática Médica/métodos , Modelos Anatómicos , Modelos Estadísticos , Huesos Pélvicos/patología , Pelvis/patología , Radiografía , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador
18.
Clin Orthop Relat Res ; 469(2): 423-8, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20852974

RESUMEN

BACKGROUND: Although surgical navigation reduces the rate of malpositioned acetabular cups in total hip arthroplasty (THA), its use has not been widely adopted. As a result of our perceived need for simple and efficient methods of navigation, we developed a mechanical navigation device for acetabular cup orientation. QUESTIONS/PURPOSES: We assessed accuracy of cup orientation (mean error of cup inclination and anteversion) of a novel mechanical navigation device, percentage of outliers, length of operation, and compared the results with a series of CT-based computer-assisted THAs. METHODS: Cup orientation of 70 THAs performed using the mechanical navigation device was compared with a historical control group of 146 THAs performed using CT-based computer navigation. Postoperative cup orientation was measured using a validated two-dimensional/three-dimensional matching method. An outlier was defined outside a range of ± 10° from the planned inclination and/or anteversion. RESULTS: Using the mechanical navigation device, we observed a decrease in the errors of inclination (1.3° ± 3.4° [range, -6.6° to 8.2°] versus 3.5° ± 4.2° [-12.7° to 6.9°]), errors of anteversion (1.0° ± 4.1° [-8.8° to 9.5°] versus 3.0° ± 5.8° [-11.8° to 19.6°]), percentages of outliers (0% versus 9.6%), and length of operation (112 ± 22 [78-184] minutes versus 132 ± 18 [90-197] minutes) compared with CT-based navigation. CONCLUSIONS: Compared with CT-based surgical navigation, navigation of acetabular cup orientation using a mechanical device can be performed in less time, lower mean errors, and minimal equipment.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Complicaciones Posoperatorias/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Humanos , Inestabilidad de la Articulación/prevención & control , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Falla de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos , Adulto Joven
19.
Comput Aided Surg ; 15(4-6): 75-82, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21067316

RESUMEN

INTRODUCTION: A novel computerized algorithm for hip joint motion simulation and collision detection, called the Equidistant Method, has been developed. This was compared to three pre-existing methods having different properties regarding definition of the hip joint center and behavior after collision detection. It was proposed that the Equidistant Method would be most accurate in detecting the location and extent of femoroacetabular impingement. MATERIALS AND METHODS: Five plastic pelves and ten plastic femora with modified acetabula and head-neck junctions, allowing for 50 different morphologic combinations, were examined, along with six cadaver hips. First, motions along anatomically relevant paths were performed. These motions were tracked by a navigation system and impingement locations were digitized with a pointer. Subsequently, previously generated 3D models of all the specimens, together with the recorded anatomic motion paths, were applied to all four simulation algorithms implemented in a diagnostic computer application. Collisions were detected within the motion paths, and the linear and angular differences regarding the location as well as the size of the detected impingement areas were compared and analyzed. RESULTS: The Equidistant Method detected impingement with significantly higher linear and angular accuracy compared to the other methods (p < 0.05). The size of the detected impingement area was smaller than that detected with the other methods, but this difference was not statistically significant. CONCLUSIONS: The increased accuracy of the Equidistant Method is achieved by implementing a dynamic hip joint center, more closely resembling the natural characteristics of the hip joint. Clinical application of this algorithm might serve as a diagnostic adjunct and support in the planning of joint-preserving surgery in patients with femoroacetabular impingement.


Asunto(s)
Algoritmos , Simulación por Computador , Pinzamiento Femoroacetabular/diagnóstico , Articulación de la Cadera/patología , Procesamiento de Imagen Asistido por Computador/métodos , Cadáver , Pinzamiento Femoroacetabular/patología , Articulación de la Cadera/anatomía & histología , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Pelvis/anatomía & histología , Pelvis/patología , Programas Informáticos , Estadísticas no Paramétricas
20.
Comput Aided Surg ; 15(4-6): 104-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21070180

RESUMEN

Three-dimensional rotational X-ray imaging with the SIREMOBIL Iso-C3D (Siemens AG, Medical Solutions, Erlangen, Germany) has become a well-established intra-operative imaging modality. In combination with a tracking system, the Iso-C3D provides inherently registered image volumes ready for direct navigation. This is achieved by means of a pre-calibration procedure. The aim of this study was to investigate the influence of the tracking system used on the overall navigation accuracy of direct Iso-C3D navigation. Three models of tracking system were used in the study: Two Optotrak 3020s, a Polaris P4 and a Polaris Spectra system, with both Polaris systems being in the passive operation mode. The evaluation was carried out at two different sites using two Iso-C3D devices. To measure the navigation accuracy, a number of phantom experiments were conducted using an acrylic phantom equipped with titanium spheres. After scanning, a special pointer was used to pinpoint these markers. The difference between the digitized and navigated positions served as the accuracy measure. Up to 20 phantom scans were performed for each tracking system. The average accuracy measured was 0.86 mm and 0.96 mm for the two Optotrak 3020 systems, 1.15 mm for the Polaris P4, and 1.04 mm for the Polaris Spectra system. For the Polaris systems a higher maximal error was found, but all three systems yielded similar minimal errors. On average, all tracking systems used in this study could deliver similar navigation accuracy. The passive Polaris system showed ­ as expected ­ higher maximal errors; however, depending on the application constraints, this might be negligible.


Asunto(s)
Diagnóstico por Computador/instrumentación , Cirugía Asistida por Computador/instrumentación , Diagnóstico por Computador/métodos , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Dispositivos Ópticos , Fantasmas de Imagen , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA