Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Appl Ergon ; 116: 104198, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38091694

RESUMEN

Shared automated mobility-on-demand promises efficient, sustainable, and flexible transportation. Nevertheless, security concerns, resilience, and their mutual influence - especially at night - will likely be the most critical barriers to public adoption since passengers have to share rides with strangers without a human driver on board. Prior research points out that having information about fellow travelers could alleviate the concerns of passengers and we designed two user interface variants to investigate the role of this information in an exploratory within-subjects user study (N=24). Participants experienced four automated day and night rides with varying personal information about co-passengers in a simulated environment. The results of the mixed-method study indicate that having information about other passengers (e.g., photo, gender, and name) positively affects user experience at night. In contrast, it is less necessary during the day. Considering participants' simultaneously raised privacy concerns, balancing security and privacy demands poses a substantial challenge for resilient system design.


Asunto(s)
Vehículos Autónomos , Transportes , Humanos
2.
Medicine (Baltimore) ; 101(7): e28866, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35363191

RESUMEN

BACKGROUND: In case of injuries to the subaxial cervical spine, especially in osteoporotic bone, the question of the most stable operative technique arises. There are several techniques of screw fixation available regarding dorsal stabilization. This study investigates 2 techniques (lateral mass screws (LMS) vs cervical pedicle screws (CPS)) in the subaxial cervical spine regarding primary stability in a biomechanical testing using a translational injury model. METHODS: A total of 10 human formalin fixed and 10 human fresh-frozen specimens (C 4 - T 1) were investigated. Specimens were randomized in 2 groups. Fracture generation of a luxation injury between C 5 and C 6 was created by a transection of all ligamentous structures as well as the intervertebral disc and a resection of the facet joints.Dorsal stabilization of C 4/C 5 to C 6/C 7 was performed in group A by lateral mass screws, in group B by pedicle screws. In the biomechanical testing, the specimens were loaded at 2 N/s in translation direction until implant failure. RESULTS: Formalin fixed specimen: Mean load failure was 513.8 (±86.74) Newton (N) for group A (LMS) and 570.4 (±156.5) N for group B (CPS). There was no significant difference (P = .6905).Fresh frozen specimen: Mean load failure was 402.3 (±96.4) N for group A (LMS) and 500.7 (±190.3) N for group B (CPS). There was no significant difference (P = .4206). CONCLUSION: In our loading model respecting the translational injury pattern and a flexion movement we could not verify statistically significant differences between lateral mass screws and cervical pedicle screws. Mean loading failure was slightly higher in the CPS group though.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Fenómenos Biomecánicos , Vértebras Cervicales/cirugía , Humanos , Rango del Movimiento Articular , Fusión Vertebral/métodos
3.
Orthop Traumatol Surg Res ; 107(7): 102945, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33895387

RESUMEN

INTRODUCTION: Spino-pelvic fixation has been widely accepted for surgical treatment of sacral tumor, scoliosis surgery and pelvic fractures. Cement augmentation of screws is an option to improve implant stability in osteoporotic bone quality. Aim of the present study is to compare iliac screw fixation without cement fixation and two cement application options in a biomechanical testing. HYPOTHESIS: Cement augmentation of iliac screws leads to superior pull-out strength. MATERIAL AND METHODS: Thirty female and osteoporotic human iliac bones were used. Three operation treatment groups were generated: Screw fixation (cannulated screws) without cement augmentation [Operation treatment (OT) A], screw fixation with cement augmentation before screw placement (cannulated screws) (OT B) and screw fixation with perforated screws and cement augmentation after screw placement (OTC). Pull-out tests were performed with a rate of 6mm/min. A load versus displacement curve was generated. Maximum pull-out force (N) was measured in the load-displacement curve. RESULTS: Paired group 1 (OT A vs. OT B): Screw fixation without cement augmentation: 592.6N±335.07 and screw fixation with cement augmentation before screw placement: 996N±287.43 (p=0.0042). Paired group 2 (OT A vs. OT C): screw fixation without cement augmentation: 716.2N±385.86 and fenestrated screw fixation with cement augmentation after screw placement: 1324.88N±398.76 (p=0.0489). Paired group 3 (OT B vs. OT C): Screw fixation with cement augmentation before screw placement: 1077.2±486.66 and fenestrated screw fixation with cement augmentation after screw placement: 1298.2N±726.19 (p=0.3286). DISCUSSION: Regarding iliac screw fixation for spino-pelvic ostesynthesis in osteoporotic bone, cement augmentation is significantly superior to solid iliac screw fixation respecting pull-out-strength. Nevertheless, further biomechanical studies are needed to verify these findings. LEVEL OF EVIDENCE: Not applicable; biomechanical cadaver study.


Asunto(s)
Cementos para Huesos , Fracturas Osteoporóticas , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Femenino , Humanos , Ilion/cirugía , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/cirugía , Pelvis
4.
GMS J Med Educ ; 38(3): Doc69, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33824905

RESUMEN

Introduction: It has been shown that communication skills acquired during undergraduate medical education are of great importance. Hence, many countries require teaching communication as part of their medical curricula. To assess students' learning progress, "Catering to the Patient", as an aspect of showing empathy, should be evaluated. Since there was no description of a validated instrument fitting for this purpose, one had to be developed. To describe its process of development and its psychometric properties were the aims of this study. Methods: Based on the Calgary-Cambridge Observation Guide (CCOG), items describing catering to the patient were selected and modified. Cognitive pretest interviews were conducted to check understandability. Therefore, 7 raters assessed 1 video each (R=7, V=1). In a following pilot study (R=3, V=10) first psychometric properties were evaluated and necessary corrections in the preliminary evaluation form were carried out before the final evaluation form was used to assess students' ability to cater to the patient and psychometric properties were described in detail (R=2, V=35). Results: The final assessment instrument, "catering to the patient - Marburg evaluation form", contains 11 checklist items and two global ratings (items 12 and 13). In the final evaluation the inter-rater reliability (IRR) ranged from 0 to 0.562, the median was r=0.305. Concerning item 13 (a global rating), 88.6% of the videos were scored with the maximum difference of one point. The internal consistency was very high (Cronbach's α: α=0.937 and α=0.962), and the correlation between the checklist items and the global rating was high (Pearson's r: r=0.856 and r=0.898). Discussion: The assessment instrument "catering to the patient" is suitable for giving feedback and for using it in formative examinations. Its use for summative examinations can be considered. Further examinations should evaluate if a three-point Likert scale could reach higher values and if item 13 can be used as a stand-alone item.


Asunto(s)
Educación de Pregrado en Medicina , Educación Médica , Relaciones Médico-Paciente , Psicometría , Educación Médica/métodos , Evaluación Educacional , Humanos , Proyectos Piloto , Psicometría/instrumentación , Reproducibilidad de los Resultados
5.
IEEE Trans Vis Comput Graph ; 27(5): 2627-2637, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33750705

RESUMEN

To provide immersive haptic experiences, proxy-based haptic feedback systems for virtual reality (VR) face two central challenges: (1) similarity, and (2) colocation. While to solve challenge (1), physical proxy objects need to be sufficiently similar to their virtual counterparts in terms of haptic properties, for challenge (2), proxies and virtual counterparts need to be sufficiently colocated to allow for seamless interactions. To solve these challenges, past research introduced, among others, two successful techniques: (a) Dynamic Passive Haptic Feedback (DPHF), a hardware-based technique that leverages actuated props adapting their physical state during the VR experience, and (b) Haptic Retargeting, a software-based technique leveraging hand redirection to bridge spatial offsets between real and virtual objects. Both concepts have, up to now, not ever been studied in combination. This paper proposes to combine both techniques and reports on the results of a perceptual and a psychophysical experiment situated in a proof-of-concept scenario focused on the perception of virtual weight distribution. We show that users in VR overestimate weight shifts and that, when DPHF and HR are combined, significantly greater shifts can be rendered, compared to using only a weight-shifting prop or unnoticeable hand redirection. Moreover, we find the combination of DPHF and HR to let significantly larger spatial dislocations of proxy and virtual counterpart go unnoticed by users. Our investigation is the first to show the value of combining DPHF and HR in practice, validating that their combination can better solve the challenges of similarity and colocation than the individual techniques can do alone.


Asunto(s)
Retroalimentación , Tecnología Háptica , Realidad Virtual , Adulto , Retroalimentación Fisiológica/fisiología , Femenino , Humanos , Masculino , Psicofísica , Tacto/fisiología , Adulto Joven
6.
BMC Musculoskelet Disord ; 22(1): 76, 2021 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-33441095

RESUMEN

BACKGROUND: Standard balloon kyphoplasty represents a well-established treatment option for osteoporotic vertebral compression fractures. Aim of the present study was to evaluate two different methods of percutaneous augmentation (standard balloon kyphoplasty (BKP) versus Tektona® (TEK)) with respect to height restoration. METHODS: Four-teen vertebral bodies of two female cadavers were examined. Fractures were created using a standardized protocol. CT-scans were taken before and after fracture, as well as after treatment. Afterwards two groups were randomly assigned in a matched pair design: 7 vertebral bodies (VB) were treated with BKP (Kyphon, Medtronic) and 7 vertebral bodies by TEK (Spineart, Switzerland) Anterior, central and posterior vertebral body heights were evaluated by CT-scans. Volumetry was performed using the CT-scans at three different timepoints. RESULTS: Values before fracture represent 100%. The anterior height after fracture was reduced to 75.99 (± 4.8) % for the BKP group and to 76.54 (± 9.17) % in the TEK Group. Statistically there was no difference for the groups (p = 1). After treatment the values increased to 93.06 (± 5) % for the BKP Group and 87.71 (± 6.2) % for the TEK Group. The difference before and after treatment was significant for both groups (BKP p = 0.0006; TEK p = 0.03). Within the groups, there was no difference (p = 0.13). The Volume of the vertebral body was reduced to 82.29 (± 8.4) % in the BKP Group and to 76.54 (± 8.6) % in the TEK Group. After treatment the volume was 89.26 (± 6.9) % for the BKP Group and 88.80 (± 8.7) % for the TEK Group. The difference before and after treatment was significant only for the TEK group (BKP p = 0.0728 n.s.; TEK p = 0.0175). Within the groups, there was no difference (p = 0.2). The average cement volume used was 6.1 (range 3.6-9 ml) for the BKP group and 5.3 (3-7.2 ml) for the TEK group respectively. CONCLUSIONS: Based on our results the new System Tektona® in osteoporotic compression fractures might represent a promising alternative for the clinical setting, especially preserving bone. Further biomechanical tests and clinical studies have to proof Tektona®`s capabilities.


Asunto(s)
Fracturas por Compresión , Cifoplastia , Fracturas Osteoporóticas , Fracturas de la Columna Vertebral , Adolescente , Cementos para Huesos , Cadáver , Femenino , Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/cirugía , Humanos , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/cirugía , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/cirugía , Suiza , Resultado del Tratamiento
7.
IEEE Trans Vis Comput Graph ; 26(5): 2104-2114, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32070982

RESUMEN

In many professional domains, relevant processes are documented as abstract process models, such as event-driven process chains (EPCs). EPCs are traditionally visualized as 2D graphs and their size varies with the complexity of the process. While process modeling experts are used to interpreting complex 2D EPCs, in certain scenarios such as, for example, professional training or education, also novice users inexperienced in interpreting 2D EPC data are facing the challenge of learning and understanding complex process models. To communicate process knowledge in an effective yet motivating and interesting way, we propose a novel virtual reality (VR) interface for non-expert users. Our proposed system turns the exploration of arbitrarily complex EPCs into an interactive and multi-sensory VR experience. It automatically generates a virtual 3D environment from a process model and lets users explore processes through a combination of natural walking and teleportation. Our immersive interface leverages basic gamification in the form of a logical walkthrough mode to motivate users to interact with the virtual process. The generated user experience is entirely novel in the field of immersive data exploration and supported by a combination of visual, auditory, vibrotactile and passive haptic feedback. In a user study with N=27 novice users, we evaluate the effect of our proposed system on process model understandability and user experience, while comparing it to a traditional 2D interface on a tablet device. The results indicate a tradeoff between efficiency and user interest as assessed by the UEQ novelty subscale, while no significant decrease in model understanding performance was found using the proposed VR interface. Our investigation highlights the potential of multi-sensory VR for less time-critical professional application domains, such as employee training, communication, education, and related scenarios focusing on user interest.


Asunto(s)
Gráficos por Computador , Interfaz Usuario-Computador , Realidad Virtual , Adulto , Algoritmos , Conducta Exploratoria/fisiología , Femenino , Humanos , Masculino , Análisis y Desempeño de Tareas , Caminata/fisiología , Adulto Joven
8.
Medicine (Baltimore) ; 98(11): e14743, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30882642

RESUMEN

Since its introduction by Metaizeau and Prevot, elastic-stable intramedullary nailing (ESIN) has been used for almost all diaphyseal fractures in children. Here, we present a retrospective study analyzing the long-term results of ESIN of forearm fractures in children.A total of 122 patients with diaphyseal forearm fractures and single subtypes in childhood were treated from 2000 to 2007 at our University Hospital by ESIN. At follow-up, the current conditions of the patients were evaluated using the Disabilities of Arm, Shoulder, and Hand (DASH) Score, and the Mayo Wrist score. Moreover, an individual questionnaire with 16 items was used to collect further information about the patient's condition and limitations as adults.The evaluation was performed at 12.4 years (average) after surgery. In our study population (n = 90), the average DASH scores for sports, performing arts, and work were 0.4 (standard deviation: 1.45), 0.9 (standard deviation: 5.68), and 0.3 (standard deviation: 7.39), respectively. Furthermore, 77% of our patients achieved a DASH Score of 0 (optimum outcome). The average Mayo Wrist Score was 97.64 (standard deviation: 7.39), and 82% of the study population achieved a score of 100 (optimum outcome). A correlation between the DASH and Mayo Wrist Scores was found in few patients. Overall, the DASH Score, Mayo Wrist Score, and results of our individual questionnaire demonstrated convincing point values.This study demonstrated favorable long-term results achieved by ESIN of forearm fractures in children. It seems that good outcomes, reported by various studies with short- to mid-term follow-up beforehand, do not deteriorate over time.Level of Evidence: Level III; retrospective study; therapeutic study.


Asunto(s)
Traumatismos del Antebrazo/cirugía , Fijación Intramedular de Fracturas/estadística & datos numéricos , Traumatismos de la Muñeca/cirugía , Adolescente , Niño , Preescolar , Traumatismos del Antebrazo/rehabilitación , Fijación Intramedular de Fracturas/métodos , Humanos , Lactante , Traumatismos de la Muñeca/rehabilitación
9.
Dtsch Arztebl Int ; 115(5): 70-80, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29439771

RESUMEN

BACKGROUND: The estimated incidence of osteoporotic pelvic fractures among persons over age 60 in Germany is 224 per 100 000 persons per year, and rising. A number of surgical treatment options are available, but clinical long-term data are lacking. METHODS: This review is based on pertinent publications and guidelines retrieved by a selective literature search, and on the authors' clinical experience. RESULTS: Patients often report one or more relatively trivial traumatic incidents leading up to the fracture. They complain of pain in the hip, groin, or lower lumbar region, or of low back pain and sciatica. A new classification scheme entitled Fragility Fractures of the Pelvis (FFP) takes the morphology of the fracture into account and can be used as an aid to therapeutic decision-making (evidence level IV). The goal of treatment is early mobilization with adequate pain relief. Isolated anterior pelvic ring fractures (FFP I) and nondisplaced posterior pelvic ring fractures (FFP II) are usually stable and can be treated conservatively. Type III and IV injuries are unstable and should generally be treated surgically. CONCLUSION: Retrospective analyses have shown that osteoporotic pelvic fractures are associated with decreased mobility and independence and with a one-year mortality ranging from 9.5% to 27%. Prospective therapeutic trials are urgently needed.


Asunto(s)
Fracturas Osteoporóticas , Huesos Pélvicos/lesiones , Absorciometría de Fotón , Anciano , Anciano de 80 o más Años , Femenino , Alemania/epidemiología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Fracturas Osteoporóticas/clasificación , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/epidemiología , Fracturas Osteoporóticas/terapia , Huesos Pélvicos/diagnóstico por imagen , Sistema de Registros , Estudios Retrospectivos
10.
Spine J ; 18(3): 525-531, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29174458

RESUMEN

BACKGROUND: In the operative treatment of osteoporotic vertebral body fractures, a dorsal stabilization in combination with a corpectomy of the fractured vertebral body might be necessary with respect to the fracture morphology, whereby the osteoporotic bone quality may possibly increase the risk of implant failure. To achieve better stability, it is recommended to use cement-augmented screws for dorsal instrumentation. Besides careful end plate preparation, cement augmentation of the adjacent end plates has also been reported to lead to less reduction loss. PURPOSE: The aim of the study was to evaluate biomechanically under cyclic loading whether an additional cement augmentation of the adjacent end plates leads to improved stability of the inserted cage. STUDY DESIGN/SETTING: Methodical cadaver study. MATERIALS AND METHODS: Fourteen fresh frozen human thoracic spines with proven osteoporosis were used (T2-T7). After removal of the soft tissues, the spine was embedded in Technovit (Kulzer, Germany). Subsequently, a corpectomy of T5 was performed, leaving the dorsal ligamentary structures intact. After randomization with respect to bone quality, two groups were generated: Dorsal instrumentation (cemented pedicle screws, Medtronic, Minneapolis, MN, USA)+cage implantation (CAPRI Corpectomy Cage, K2M, Leesburg, VA, USA) without additional cementation of the adjacent endplates (Group A) and dorsal instrumentation+cage implantation with additional cement augmentation of the adjacent end plates (Group B). The subsequent axial and cyclic loading was performed at a frequency of 1 Hz, starting at 400 N and increasing the load within 200 N after every 500 cycles up to a maximum of 2,200 N. Load failure was determined when the cages sintered macroscopically into the end plates (implant failure) or when the maximum load was reached. RESULTS: One specimen in Group B could not be clamped appropriately into the test bench for axial loading because of a pronounced scoliotic misalignment and had to be excluded. The mean strength for implant failure was 1,000 N±258.2 N in Group A (no cement augmentation of the adjacent end plates, n=7); on average, 1,622.1±637.6 cycles were achieved. In Group B (cement augmentation of the adjacent end plates, n=6), the mean force at the end of loading was 1,766.7 N±320.4 N; an average of 3,572±920.6 cycles was achieved. Three specimens reached a load of 2,000 N. The differences between the two groups were significant (p=.006 and p=.0047) regarding load failure and number of cycles. CONCLUSIONS: Additional cement augmentation of the adjacent end plates during implantation of a vertebral body replacement in osteoporotic bone resulted in a significant increased stability of the cage in the axial cyclic loading test.


Asunto(s)
Cementos para Huesos/efectos adversos , Cementación/métodos , Fracturas Osteoporóticas/cirugía , Fracturas de la Columna Vertebral/cirugía , Fusión Vertebral/métodos , Anciano , Fenómenos Biomecánicos , Placas Óseas/efectos adversos , Cementación/efectos adversos , Humanos , Tornillos Pediculares/efectos adversos , Fusión Vertebral/efectos adversos
11.
IEEE Trans Vis Comput Graph ; 23(4): 1285-1294, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28129164

RESUMEN

We define the concept of Dynamic Passive Haptic Feedback (DPHF) for virtual reality by introducing the weight-shifting physical DPHF proxy object Shifty. This concept combines actuators known from active haptics and physical proxies known from passive haptics to construct proxies that automatically adapt their passive haptic feedback. We describe the concept behind our ungrounded weight-shifting DPHF proxy Shifty and the implementation of our prototype. We then investigate how Shifty can, by automatically changing its internal weight distribution, enhance the user's perception of virtual objects interacted with in two experiments. In a first experiment, we show that Shifty can enhance the perception of virtual objects changing in shape, especially in length and thickness. Here, Shifty was shown to increase the user's fun and perceived realism significantly, compared to an equivalent passive haptic proxy. In a second experiment, Shifty is used to pick up virtual objects of different virtual weights. The results show that Shifty enhances the perception of weight and thus the perceived realism by adapting its kinesthetic feedback to the picked-up virtual object. In the same experiment, we additionally show that specific combinations of haptic, visual and auditory feedback during the pick-up interaction help to compensate for visual-haptic mismatch perceived during the shifting process.

12.
Acta Orthop Belg ; 83(4): 497-505, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30423654

RESUMEN

Deformation of the spine following vertebral compression fracture (VCF) can be associated with severe spinal dysfunction. Anatomical restoration is described as the complete reduction and stable fixation of the fracture with the goal to restore the pre-fracture local and global spine properties. The essential need to obtain endplate reduction, and consider the whole vertebral body in the management of vertebral fractures is pointed out. A new 3D imaging technique is described. A new assessment method based on CT scans 3D reconstructions was developed. This new method was used to assess the anatomical restoration of the fractured vertebrae. A procedure consisting in placing two expandable titanium implants for fracture reduction, together with stabilization with a high viscosity PMMA cement was used to demonstrate the method. The cases presented here are demonstrating that this 3D-mapping software is a tool which can address the lack of a valid, reproducible and user-friendly method to evaluate the anatomical restoration in VCF. The evaluation of the anatomical restoration of the fractured vertebrae raises some issues in terms of interpretation because of a lack of consensus in the existing reporting methods. A 3D-reconstruction method, using CT scans and a newly-developed software, is proposed to evaluate the anatomical restoration in a clear, valid, reproducible and user-friendly way.


Asunto(s)
Fracturas por Compresión/cirugía , Imagenología Tridimensional , Fracturas de la Columna Vertebral/cirugía , Columna Vertebral/anatomía & histología , Columna Vertebral/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Columna Vertebral/cirugía
13.
Spine J ; 17(1): 70-75, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27503262

RESUMEN

BACKGROUND CONTEXT: Pedicle screws in spinal surgery have allowed greater biomechanical stability and higher fusion rates. However, malposition is very common and may cause neurologic, vascular, and visceral injuries and compromise mechanical stability. PURPOSE: The purpose of this study was to compare the malposition rate between intraoperative computed tomography (CT) scan assisted-navigation and free-hand fluoroscopy-guided techniques for placement of pedicle screw instrumentation. STUDY DESIGN/SETTING: This is a prospective, randomized, observational study. PATIENT SAMPLE: A total of 114 patients were included: 58 in the assisted surgery group and 56 in the free-hand fluoroscopy-guided surgery group. OUTCOME MEASURES: Analysis of screw position was assessed using the Heary classification. Breach severity was defined according to the Gertzbein classification. Radiation doses were evaluated using thermoluminescent dosimeters, and estimates of effective and organ doses were made based on scan technical parameters. METHODS: Consecutive patients with degenerative disease, who underwent surgical procedures using the free-hand, or intraoperative navigation technique for placement of transpedicular instrumentation, were included in the study. RESULTS: Forty-four out of 625 implanted screws were malpositioned: 11 (3.6%) in the navigated surgery group and 33 (10.3%) in the free-hand group (p<.001). Screw position according to the Heary scale was Grade II (4 navigated surgery, 6 fluoroscopy guided), Grade III (3 navigated surgery, 11 fluoroscopy guided), Grade IV (4 navigated surgery, 16 fluoroscopy guided), and Grade V (1 fluoroscopy guided). There was only one symptomatic case in the conventional surgery group. Breach severity was seven Grade A and four Grade B in the navigated surgery group, and eight Grade A, 24 Grade B, and one Grade C in free-hand fluoroscopy-guided surgery group. Radiation received per patient was 5.8 mSv (4.8-7.3). The median dose received in the free-hand fluoroscopy group was 1 mGy (0.8-1.1). There was no detectable radiation level in the navigation-assisted surgery group, whereas the effective dose was 10 µGy in the free-hand fluoroscopy-guided surgery group. CONCLUSIONS: Malposition rate, both symptomatic and asymptomatic, in spinal surgery is reduced when using CT-guided placement of transpedicular instrumentation compared with placement under fluoroscopic guidance, with radiation values within the safety limits for health. Larger studies are needed to determine risk-benefit in these patients.


Asunto(s)
Procedimientos Neuroquirúrgicos/efectos adversos , Tornillos Pediculares/efectos adversos , Complicaciones Posoperatorias , Cirugía Asistida por Computador/efectos adversos , Anciano , Femenino , Fluoroscopía , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Procedimientos Neuroquirúrgicos/métodos , Estudios Prospectivos , Distribución Aleatoria , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X
14.
Turk Neurosurg ; 26(4): 608-14, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27400110

RESUMEN

AIM: To evaluate the efficacy, feasibility and safety of a percutaneous anatomical vertebral body reduction for the treatment of VCF (vertebral compression fracture) linked to malignancy. Vertebroplasty and percutaneous kyphoplasty have played essential roles in the treatment of painful vertebral metastasis, although there are few reports with long survival that have evaluated the long-term efficacy, adjacent fractures and vertebral body (VB) re-collapse associated with these procedures. We aimed to evaluate the longterm efficacy and the complications associated with malignancy and changes in spinal biomechanics. MATERIAL AND METHODS: The retrospective study examined 32 patients with osteolytic VCF due to malignant infiltration of the vertebral body. A visual analogue scale, the EQ5 and radiological analysis (i.e., X-ray and CT scan) were used to assess back pain, quality of life and complications. RESULTS: Statistically significant reductions in anterior and central vertebral body heights (6.2 mm-19.6 ± 4.2 mm- and 5.8 mm- 16.7 ± 7.8 mm-, respectively) that resulted in reductions of the regional Cobb angles exceeding 30% were observed. There was also a statistically significant improvement in quality of life. The average survival was longer than those reported in most published articles, and the average follow-up period was 30.9 months. CONCLUSION: Anatomical restoration (i.e., cortical ring reduction with endplate rebalancing) is potentially beneficial for a wellselected group of patients with spine metastases and long life expectancies because this procedure avoids the complications typical of these types of treatments (e.g., leakage, adjacent fractures and re-collapse).


Asunto(s)
Fracturas por Compresión/diagnóstico por imagen , Fracturas por Compresión/cirugía , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/cirugía , Anciano , Dolor de Espalda/diagnóstico por imagen , Dolor de Espalda/etiología , Dolor de Espalda/cirugía , Femenino , Estudios de Seguimiento , Fracturas por Compresión/etiología , Humanos , Cifoplastia/métodos , Masculino , Persona de Mediana Edad , Neoplasias , Dimensión del Dolor/métodos , Estudios Retrospectivos , Medición de Riesgo , Fracturas de la Columna Vertebral/etiología , Neoplasias de la Columna Vertebral/complicaciones , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/lesiones , Vértebras Torácicas/cirugía , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Vertebroplastia/métodos
15.
Spine J ; 16(2): 226-32, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26282106

RESUMEN

BACKGROUND: The incidence of osteoporotic and insufficiency fractures of the pelvic ring is increasing. Closed reduction and percutaneous fixation with cannulated sacroiliac screws is well-established in the operative treatment of osteoporotic posterior pelvic ring fractures. However, osteoporotic bone quality might lead to the risk of screw loosening. For this reason, cement augmentation of the iliosacral screws is more frequently performed and recommended. PURPOSE: The aim of the present biomechanical study was to evaluate the primary stability of three methods of iliosacral screw fixation in human osteoporotic sacrum specimens. STUDY DESIGN/SETTING: This study used methodical cadaver study. METHODS: A total of 15 fresh frozen human cadaveric specimens with osteoporosis were used (os sacrum). After matched pair randomization regarding bone quality (T-score), three operation technique groups were generated: screw fixation (cannulated screws) without cement augmentation (Group A); screw fixation with cement augmentation before screw placement (cannulated screws) (Group B); and screw fixation with perforated screws and cement augmentation after screw placement (Group C). In all specimens both sides of the os sacrum were used for operative treatment, resulting in a group size of 10 specimens per group. One operation technique was used on each side of the sacral bone to compare biomechanical properties in the same bone quality. Pull-out tests were performed with a rate of 6 mm/min. A load versus displacement curve was generated. RESULTS: Subgroup 1 (Group A vs. Group B): Screw fixation without cement augmentation: 594.4 N±463.7 and screw fixation with cement augmentation before screw placement: 1,020.8 N±333.3; values were significantly different (p=.025). Subgroup 2 (Group A vs. Group C): Screw fixation without cement augmentation: 641.8 N±242.0 and perforated screw fixation with cement augmentation after screw placement: 1,029.6 N±326.5; values were significantly different (p=.048). Subgroup 3 (Group B vs. Group C): Screw fixation with cement augmentation before screw placement: 804.0 N±515.3 and perforated screw fixation with cement augmentation after screw placement: 889.8 N±503.3; values were not significantly different (p=.472). CONCLUSIONS: Regarding iliosacral screw fixation in osteoporotic bone, the primary stability of techniques involving cement augmentation is significantly higher compared with screw fixation without cement augmentation. Perforated screws with the same primary stability as that of conventional screw fixation in combination with cement augmentation might be a promising alternative in reducing complications of cement leakage. These biomechanical results have to be transferred into clinical practice and prove their clinical value.


Asunto(s)
Tornillos Óseos , Fijación de Fractura/métodos , Fracturas Osteoporóticas/cirugía , Fenómenos Biomecánicos , Cadáver , Fijación de Fractura/instrumentación , Humanos
16.
J Neurosurg Spine ; 24(4): 580-5, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26682598

RESUMEN

OBJECT: The treatment of traumatic burst fractures unaccompanied by neurological impairment remains controversial and ranges from conservative management to 360° fusion. Because of the heterogeneity of fracture types, classification systems, and treatment options, comparative biomechanical studies might help to improve our knowledge. The aim of the current study was to create a standardized fracture model to investigate burst fractures in a multisegmental setting. METHODS: A total of 28 thoracolumbar fresh-frozen human cadaveric spines were used. The spines were dissected into segments (T11-L3). The T-11 and L-3 vertebral bodies were embedded in Technovit 3040 (cold-curing resin for surface testing and impressions). To simulate high energy, a metallic drop tower was designed. Stress risers were used to ensure comparable fractures. CT scans were acquired before and after fracture. All fractures were classified using the AO/OTA classification. RESULTS: The preparation and embedding of the spine segments worked well. No repositioning or second embedding of the specimen, even after fracture, was required. It was possible to create single burst fractures at the L-1 level in all 28 spine segments. Among the 28 fractures there were 16 incomplete burst fractures (Type A3.1), 8 burst-split fractures (Type A3.2), and 4 complete burst fractures (Type A3.3). The differences before and after fracture for stiffness and for anterior, posterior, and central heights were all significant (p < 0.05). CONCLUSIONS: The ability to create reproducible burst fractures of a single vertebral body in a thoracolumbar spine segment may serve as a basis for future biomechanical studies that will provide better understanding of mechanical properties or fixation techniques.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Fracturas Óseas/cirugía , Vértebras Lumbares/cirugía , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/cirugía , Adulto , Anciano , Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Resultado del Tratamiento
17.
Biomed Res Int ; 2015: 434873, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26137481

RESUMEN

PURPOSE: The treatment of vertebral burst fractures is still controversial. The aim of the study is to evaluate the purpose of additional percutaneous intravertebral reduction when combined with dorsal instrumentation. METHODS: In this biomechanical cadaver study twenty-eight spine segments (T11-L3) were used (male donors, mean age 64.9 ± 6.5 years). Burst fractures of L1 were generated using a standardised protocol. After fracture all spines were allocated to four similar groups and randomised according to surgical techniques (posterior instrumentation; posterior instrumentation + intravertebral reduction device + cement augmentation; posterior instrumentation + intravertebral reduction device without cement; and intravertebral reduction device + cement augmentation). After treatment, 100000 cycles (100-600 N, 3 Hz) were applied using a servohydraulic loading frame. RESULTS: Overall anatomical restoration was better in all groups where the intravertebral reduction device was used (p < 0.05). In particular, it was possible to restore central endplates (p > 0.05). All techniques decreased narrowing of the spinal canal. After loading, clearance could be maintained in all groups fitted with the intravertebral reduction device. Narrowing increased in the group treated with dorsal instrumentation. CONCLUSIONS: For height and anatomical restoration, the combination of an intravertebral reduction device with dorsal instrumentation showed significantly better results than sole dorsal instrumentation.


Asunto(s)
Fracturas por Compresión/cirugía , Vértebras Lumbares/cirugía , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/cirugía , Anciano , Fenómenos Biomecánicos , Cementos para Huesos/uso terapéutico , Cadáver , Fracturas por Compresión/fisiopatología , Humanos , Vértebras Lumbares/fisiopatología , Masculino , Persona de Mediana Edad , Fracturas de la Columna Vertebral/fisiopatología , Vértebras Torácicas/fisiopatología
18.
Biomed Res Int ; 2015: 927813, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25667929

RESUMEN

The purpose of this prospective multicentric observational study was to confirm the safety and clinical performance of a craniocaudal expandable implant used in combination with high viscosity PMMA bone cement for the treatment of vertebral compression fractures. Thirty-nine VCFs in 32 patients were treated using the SpineJack minimally invasive surgery protocol. Outcome was determined by using the Visual Analogue Scale for measuring pain, the Oswestry Disability Index for scoring functional capacity, and the self-reporting European Quality of Life scores for the quality of life. Safety was evaluated by reporting all adverse events. The occurrence of cement leakages was assessed by either radiographs or CT scan or both. Statistically significant improvements were found regarding pain, function, and quality of life. The global pain score reduction at 1 year was 80.9% compared to the preoperative situation and the result of the Oswestry Disability Index showed a decrease from 65.0% at baseline to 10.5% at 12 months postoperatively. The cement leakage rate was 30.8%. No device- or surgery-related complications were found. This observational study demonstrates promising and persistent results consisting of immediate and sustained pain relief and durable clinical improvement after the procedure and throughout the 1-year follow-up period.


Asunto(s)
Fracturas por Compresión/cirugía , Procedimientos Ortopédicos/efectos adversos , Procedimientos Ortopédicos/instrumentación , Prótesis e Implantes , Fracturas de la Columna Vertebral/cirugía , Anciano , Anciano de 80 o más Años , Cementos para Huesos/uso terapéutico , Femenino , Fracturas por Compresión/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Dolor Postoperatorio , Estudios Prospectivos , Diseño de Prótesis , Calidad de Vida , Fracturas de la Columna Vertebral/epidemiología , Resultado del Tratamiento
19.
Biomed Res Int ; 2015: 173872, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26844224

RESUMEN

This prospective, consecutive, multicentre observational registry aimed to confirm the safety and clinical performance of the SpineJack system for the treatment of vertebral compression fractures (VCF) of traumatic origin. We enrolled 103 patients (median age: 61.6 years) with 108 VCF due to trauma, or traumatic VCF with associated osteoporosis. Primary outcome was back pain intensity (VAS). Secondary outcomes were Oswestry Disability Index (ODI), EuroQol-VAS, and analgesic consumption. 48 hours after surgery, a median relative decrease in pain intensity of 81.5% was observed associated with a significant reduction in analgesic intake. Improvements in disability (91.3% decrease in ODI score) and in quality of life (increase 21.1% of EQ-VAS score) were obtained 3 months after surgery. All results were maintained at 12 months. A reduction in the kyphotic angulation was observed postoperatively (-5.4 ± 6.3°; p < 0.001), remained at 12 months (-4.4 ± 6.0°, p = 0.002). No adverse events were implant-related and none required device removal. Three patients (2.9%) experienced procedure-related complications. The overall adjacent fracture rate up to 1 year after surgery was 2.9%. The SpineJack procedure is an effective, low-risk procedure for patients with traumatic VCF allowing a fast and sustained improvement in quality of life over 1 year after surgery.


Asunto(s)
Dolor de Espalda/cirugía , Osteoporosis/cirugía , Calidad de Vida , Fracturas de la Columna Vertebral/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
20.
Spine J ; 15(5): 1092-8, 2015 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24200410

RESUMEN

BACKGROUND: The treatment of osteoporotic vertebral compression fractures using transpedicular cement augmentation has grown significantly during the past two decades. Balloon kyphoplasty was developed to restore vertebral height and improve sagittal alignment. Several studies have shown these theoretical improvements cannot be transferred universally to the clinical setting. PURPOSE: The aim of the current study is to evaluate two different procedures used for percutaneous augmentation of vertebral compression fractures with respect to height restoration: balloon kyphoplasty and SpineJack. MATERIALS AND METHODS: Twenty-four vertebral bodies of two intact, fresh human cadaveric spines (T6-L5; donor age, 70 years and 60 years; T-score -6.8 points and -6.3 points) were scanned using computed tomography (CT) and dissected into single vertebral bodies. Vertebral wedge compression fractures were created by a material testing machine (Universal testing machine, Instron 5566, Darmstadt, Germany). The axial load was increased continuously until the height of the anterior edge of the vertebral body was reduced by 40% of the initial measured values. After 15 minutes, the load was decreased manually to 100 N. After postfracture CT, the clamped vertebral bodies were placed in a custom-made loading frame with a preload of 100 N. Twelve vertebral bodies were treated using SpineJack (SJ; Vexim, Balma, France), the 12 remaining vertebral bodies were treated with balloon kyphoplasty (BKP; Kyphon, Medtronic, Sunnyvale, CA, USA). The load was maintained during the procedure until the cement set completely. Posttreatment CT was performed. Anterior, central, and posterior height as well as the Beck index were measured prefracture and postfracture as well as after treatment. RESULTS: For anterior height restoration (BKP, 0.14±1.48 mm; SJ, 3.34±1.19 mm), central height restoration (BKP, 0.91±1.04 mm; SJ, 3.24±1.22 mm), and posterior restoration (BKP, 0.37±0.57 mm; SJ, 1.26±1.05), as well as the Beck index (BKP, 0.00±0.06 mm; SJ, 0.10±0.06), the values for the SpineJack group were significantly higher (p<.05) CONCLUSION: The protocols for creating wedge fractures and using the instrumentation under a constant preload of 100 N led to reproducible results and effects. The study showed that height restoration was significantly better in the SpineJack group compared with the balloon kyphoplasty group. The clinical implications include a better restoration of the sagittal balance of the spine and a reduction of the kyphotic deformity, which may relate to clinical outcome and the biological healing process.


Asunto(s)
Fracturas por Compresión/cirugía , Cifoplastia/métodos , Fracturas Osteoporóticas/cirugía , Fracturas de la Columna Vertebral/cirugía , Anciano , Cementos para Huesos/uso terapéutico , Humanos , Cifoplastia/instrumentación , Vértebras Lumbares/cirugía , Persona de Mediana Edad , Vértebras Torácicas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...