Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Anaesthesia ; 75(3): 374-385, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31792941

RESUMEN

The multidisciplinary International Committee for the Advancement of Procedural Sedation presents the first fasting and aspiration prevention recommendations specific to procedural sedation, based on an extensive review of the literature. These were developed using Delphi methodology and assessment of the robustness of the available evidence. The literature evidence is clear that fasting, as currently practiced, often substantially exceeds recommended time thresholds and has known adverse consequences, for example, irritability, dehydration and hypoglycaemia. Fasting does not guarantee an empty stomach, and there is no observed association between aspiration and compliance with common fasting guidelines. The probability of clinically important aspiration during procedural sedation is negligible. In the post-1984 literature there are no published reports of aspiration-associated mortality in children, no reports of death in healthy adults (ASA physical status 1 or 2) and just nine reported deaths in adults of ASA physical status 3 or above. Current concerns about aspiration are out of proportion to the actual risk. Given the lower observed frequency of aspiration and mortality than during general anaesthesia, and the theoretical basis for assuming a lesser risk, fasting strategies in procedural sedation can reasonably be less restrictive. We present a consensus-derived algorithm in which each patient is first risk-stratified during their pre-sedation assessment, using evidence-based factors relating to patient characteristics, comorbidities, the nature of the procedure and the nature of the anticipated sedation technique. Graded fasting precautions for liquids and solids are then recommended for elective procedures based upon this categorisation of negligible, mild or moderate aspiration risk. This consensus statement can serve as a resource to practitioners and policymakers who perform and oversee procedural sedation in patients of all ages, worldwide.


Asunto(s)
Sedación Consciente/métodos , Sedación Consciente/normas , Ayuno , Adolescente , Adulto , Algoritmos , Niño , Preescolar , Sedación Consciente/efectos adversos , Consenso , Técnica Delphi , Adhesión a Directriz , Humanos , Lactante , Recién Nacido , Aspiración Respiratoria de Contenidos Gástricos/prevención & control
2.
Artículo en Inglés | MEDLINE | ID: mdl-28943700

RESUMEN

This study evaluates the capabilities of a whole-body photon counting CT system to differentiate between four common kidney stone materials, namely uric acid (UA), calcium oxalate monohydrate (COM), cystine (CYS),and apatite (APA) ex vivo. Two different x-ray spectra (120 kV and 140 kV) were applied and two acquisition modes were investigated; The macro-mode generates two energy threshold based image-volumes and two energy bin based image-volumes. In the chesspattern-mode, however, four energy thresholds are applied. A virtual low energy image, as well as a virtual high energy image are derived from initial threshold-based images, while considering their statistically correlated nature. The energy bin based images of the macro-mode, as well as the virtual low and high energy image of the chesspattern-mode serve as input for our dual energy evaluation. The dual energy ratio of the individually segmented kidney stones were utilized to quantify the discriminability of the different materials. The dual energy ratios of the two acquisition modes showed high correlation for both applied spectra. Wilcoxon-rank sum tests and the evaluation of the area under the receiver operating characteristics curves suggest that the UA kidney stones are best differentiable from all other materials (AUC = 1.0), followed by CYS (AUC ≈ 0.9 compared against COM and APA). COM and APA, however, are hardly distinguishable (AUC between 0.63 and 0.76). The results hold true for the measurements of both spectra and both acquisition modes.

3.
Phys Med ; 34: 72-79, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28173979

RESUMEN

PURPOSE: The use of Electronic Portal Imaging Devices (EPIDs) to acquire dosimetric information, especially for 3D-back-projection, has been increasingly extended. For a precise back-projection, the accurate knowledge of the movement characteristics of the EPID during gantry rotation is an essential requirement. METHODS AND MATERIAL: Measurements were conducted with different alignments of steel balls, which were mounted on the treatment table to avoid secondary effects such as the mechanical sag of gantry or jaws. The image movement of the EPID was determined by comparing the predicted projections of the phantoms with the EPID acquired image. Effects on dosimetric verifications were evaluated by γ-evaluation. RESULTS: The measurement results showed that the shift of the EPID image is larger in Y direction than in X direction. A maximum rotation of 0.3° and nodding of 2.4° of the detector was calculated. Changes in SDD were found up to 10mm. The angles of nodding are overall higher at discrete gantry angles in comparison to images detected for continuous rotation. Using these results we were able to correct the EPID images used for verification measurements. γ-evaluation revealed a significantly improved agreement between planned and measured EPID signal values. CONCLUSION: The measurement methods and algorithms introduced in this study are simple and comprehensive. Using these methods and algorithms we were able to quantify the major effects on geometrical and dosimetric characteristics. This allows the correction of EPID signal measurements for these effects related to the gantry angle, leading to an improved γ-evaluation for treatment plans.


Asunto(s)
Equipos y Suministros Eléctricos , Radiometría/instrumentación , Rotación , Fantasmas de Imagen
4.
Br J Anaesth ; 118(3): 344-354, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-28186265

RESUMEN

Background: Although pulmonary aspiration complicating operative general anaesthesia has been extensively studied, little is known regarding aspiration during procedural sedation. Methods: We performed a comprehensive, systematic review to identify and catalogue published instances of aspiration involving procedural sedation in patients of all ages. We sought to report descriptively the circumstances, nature, and outcomes of these events. Results: Of 1249 records identified by our search, we found 35 articles describing one or more occurrences of pulmonary aspiration during procedural sedation. Of the 292 occurrences during gastrointestinal endoscopy, there were eight deaths. Of the 34 unique occurrences for procedures other than endoscopy, there was a single death in a moribund patient, full recovery in 31, and unknown recovery status in two. We found no occurrences of aspiration in non-fasted patients receiving procedures other than endoscopy. Conclusions: This first systematic review of pulmonary aspiration during procedural sedation identified few occurrences outside of gastrointestinal endoscopy, with full recovery typical. Although diligent caution remains warranted, our data indicate that aspiration during procedural sedation appears rare, idiosyncratic, and typically benign.


Asunto(s)
Anestesia General , Complicaciones Intraoperatorias/fisiopatología , Aspiración Respiratoria/fisiopatología , Humanos
6.
Strahlenther Onkol ; 191(2): 192-200, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25238990

RESUMEN

INTRODUCTION: The additional radiation exposure applied to patients undergoing cone-beam computed tomography (CBCT) for image registration in radiation therapy is of great concern. Since a decrease in CBCT dose is linked to a degradation of image quality, the consequences of dose reduction on the registration process have to be investigated. MATERIAL AND METHODS: This paper examines image quality and registration of low-contrast structures on an Elekta XVI for the two treatment areas prostate and chest while gradually decreasing the mAs per frame and the number of projections per CBCT to achieve dose reduction. RESULTS: Ideal results for image quality were obtained for 1.6 mAs/frame and 377 projections in prostate scans and 0.63 mAs/frame and 440 projections in chest images. Lower as well as higher total mAs lead to a decrease in image quality. In spite of poor image quality, registration can be successfully performed even for lowest possible settings. CONCLUSION: The results for registration allow an extensive dose reduction in both treatment areas. Very low mAs, however, do not qualify for clinical use because subjective judgment of the registration process is impossible. Compared to default presets the use of settings for acceptable image quality already permit a decrease in exposure of about 40 % (29.0 to 16.7 mGy) in prostate scans and 60 % (18.3 to 7.7 mGy) in chest scans.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Aumento de la Imagen , Neoplasias de la Próstata/radioterapia , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Torácicas/radioterapia , Algoritmos , Tomografía Computarizada de Haz Cónico/normas , Estudios de Factibilidad , Humanos , Masculino , Fantasmas de Imagen , Neoplasias de la Próstata/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/normas , Neoplasias Torácicas/patología
7.
Eur Radiol ; 24(10): 2449-57, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24965507

RESUMEN

OBJECTIVES: To assess the diagnostic accuracy of dual-energy computed tomography (DECT) for detection of endoleaks and aneurysm sac calcifications after endovascular aneurysm repair (EVAR) using hard plaque imaging algorithms. MATERIALS AND METHODS: One hundred five patients received 108 triple-phase contrast-enhanced CT (non-contrast, arterial and delayed phase) after EVAR. The delayed phase was acquired in dual-energy and post-processed using the standard (HPI-S) and a modified (HPI-M) hard plaque imaging algorithm. The reference standard was determined using the triple-phase CT and contrast-enhanced ultrasound. All images were analysed separately for the presence of endoleaks and calcifications by two independent readers; sensitivity, specificity and interobserver agreement were calculated. RESULTS: Endoleaks and calcifications were present in 25.9 % (28/108) and 20.4 % (22/108) of images. The HPI-S images had a sensitivity/specificity of 54 %/100 % (reader 1) and 57 %/99 % (reader 2), the HPI-M images of 93 %/92 % (reader 1) and 96 %/92 % (reader 2) for detection of endoleaks. For detection of calcifications HPI-S had a sensitivity/specificity of 91 %/99 % (reader 1) and 95 %/97 % (reader 2), the HPI-M images of 91 %/99 % (reader 1) and 91 %/99 % (reader 2), respectively. CONCLUSION: Using HPI-M, DECT enables an accurate diagnosis of endoleaks after EVAR and allows distinguishing between endoleaks and calcifications with high diagnostic accuracy. KEY POINTS: • Dual-energy computed tomography allows the diagnosis of aortic pathologies after EVAR. • Hard plaque imaging algorithms can distinguish between endoleaks and aneurysm sac calcifications. • The modified hard plaque imaging algorithm detects endoleaks with high diagnostic accuracy.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Calcinosis/complicaciones , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/cirugía , Calcinosis/diagnóstico por imagen , Endofuga/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados
8.
Neuroradiology ; 55(4): 423-30, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23223824

RESUMEN

INTRODUCTION: High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. METHODS: CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. RESULTS: Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35% (218.2 ± 30 versus 141.8 ± 20 mGy × cm). CONCLUSIONS: Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.


Asunto(s)
Angiografía/métodos , Aorta Torácica/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Carga Corporal (Radioterapia) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
AJNR Am J Neuroradiol ; 33(5): 865-72, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22241388

RESUMEN

BACKGROUND AND PURPOSE: Detection of underlying tumor in patients with unknown-origin acute ICH may be difficult because acute hematoma may mask enhancement of tumor on postcontrast CT. We intended to investigate the clinical utility of DECT in differentiating tumor bleeding from pure ICH. MATERIALS AND METHODS: Using a dual-source CT scanner, we obtained TNC single-energy and postcontrast DECT scans for 56 patients with unknown-origin spontaneous ICH. From the 2 sets of postcontrast DECT images obtained with different tube energy, EA (equivalent to conventional postcontrast CT), VNC, color-coded iodine overlay, fusion images of iodine overlay and VNC images were produced. The diagnostic performances of fusion, EA, and combined EA and TNC images for detecting underlying tumors were compared. RESULTS: Of the 56 patients, 17 had primary or metastatic tumors (18 lesions) and 39 had nontumorous ICH. The sensitivities of fusion, EA, and combined EA and TNC images for detecting brain tumors were 94.4%, 61.1%, and 66.7%, respectively, and their specificities were 97.4%, 92.3%, and 89.7%, respectively. The areas under the ROC curves were 0.964, 0.786, and 0.842, respectively. Overall, the diagnostic performance of fusion images was significantly superior to EA (P = .006) and combined EA and TNC (P = .011) images. CONCLUSIONS: DECT may be useful in detecting underlying tumors in patients with unknown-origin ICH.


Asunto(s)
Neoplasias Encefálicas/complicaciones , Neoplasias Encefálicas/diagnóstico por imagen , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/etiología , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
10.
Eur J Radiol ; 81(5): e699-703, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21316888

RESUMEN

PURPOSE: The aim of this study was to explore the relationship of scanning parameters (clinical protocols), reconstruction kernels and slice thickness with image quality and radiation dose in a DSCT. MATERIALS AND METHODS: The chest of an anthropomorphic phantom was scanned on a DSCT scanner (Siemens Somatom Definition flash) using different clinical protocols, including single- and dual-energy modes. Four scan protocols were investigated: 1) single-source 120kV, 110mAs, 2) single-source 100kV, 180mAs, 3) high-pitch 120kV, 130mAs and 4) dual-energy with 100/Sn140kV, eff.mAs 89, 76. The automatic exposure control was switched off for all the scans and the CTDIvol selected was in between 7.12 and 7.37mGy. The raw data were reconstructed using the reconstruction kernels B31f, B80f and B70f, and slice thicknesses were 1.0mm and 5.0mm. Finally, the same parameters and procedures were used for the scanning of water phantom. Friedman test and Wilcoxon-Matched-Pair test were used for statistical analysis. RESULTS: The DLP based on the given CTDIvol values showed significantly lower exposure for protocol 4, when compared to protocol 1 (percent difference 5.18%), protocol 2 (percent diff. 4.51%), and protocol 3 (percent diff. 8.81%). The highest change in Hounsfield Units was observed with dual-energy Sn140-kV (Hounsfield unit 15.18) compared to protocol 2 (24.35HU). The differences in noise between the different clinical protocol data sets were statistically significant [protocol 3 vs. dual-energy 100-kV (p<0.01) and protocol 3 vs. dual-energy Sn140-kV (p<0.01)]. The dual-energy Sn140-kV protocol shows the highest image noise (14.5HU for 5.0mm slice (B31f) and 162HU for 1.0mm slice (B70f) thickness). The difference between reconstruction kernel B31f and B80f images made using 5.0mm reconstruction thickness was statistically significant (p<0.0312) and 1.0mm slice thickness shows the significance of p<0.0312 between B31f and B70f reconstructions. In both cases, the lowest image noise was obtained from B31f reconstructed images. Again the slice thickness significantly affects image noise (p<0.03) and the noise was higher at 1.0mm compared to that at 5.0mm slice thickness. CONCLUSION: The clinical protocol, reconstruction kernel, slice thickness and phantom diameter or the density of material it contains directly affects the image quality. Dual energy protocol shows the lowest dose-length-product compared to all other protocols examined, the fused image shows excellent image quality and the noise is same as that of single or high-pitch mode protocol images. Advanced CT technology improves image quality and considerably reduces radiation dose.


Asunto(s)
Algoritmos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Antropometría , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Agua
11.
Eur J Radiol ; 76(1): 61-7, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19520534

RESUMEN

PURPOSE: We sought to evaluate the feasibility and efficiency of dual energy (DE) bone and plaque removal in head and neck CT angiography. MATERIALS AND METHODS: 20 patients with suspected carotid stenoses received head and neck DE-CTA as part of their pre-interventional workup. Visual grading using multiplanar reformations (MPR), thick slab maximum intensity projections (MIP) and quantitative vessel analysis (QVA) of stenoses was performed prior and after DE bone removal. Results were evaluated for the detection of relevant stenoses (vessel area reduction >70%). Vessel segmentation errors were analyzed. RESULTS: Segmentation errors occurred in 19% of all vessel segments. Nevertheless, most post-bone removal artifacts could be recognized using the MPR technique for reading. Compared to MPR reading prior to bone removal, sensitivity, specificity, positive and negative predictive values after bone removal were 100%, 98%, 88% and 100% for MPR reading and 100%, 91%, 63% and 100% for exclusive MIP reading, respectively. There was a good agreement between the QVA results prior and post-DE plaque removal (r(2)=0.8858). CONCLUSION: DE bone and plaque removal for head and neck angiography is feasible and offers a rapid and highly sensitive overview over vascular head and neck studies. Due to a slightly limited specificity of the MIP technique due to segmentation errors, possible stenoses should be verified and graded using MPR techniques.


Asunto(s)
Angiografía de Substracción Digital/métodos , Estenosis Carotídea/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Cuello/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Artefactos , Huesos/diagnóstico por imagen , Medios de Contraste , Estudios de Factibilidad , Humanos , Yopamidol/análogos & derivados , Valor Predictivo de las Pruebas , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Sensibilidad y Especificidad , Arteria Vertebral/diagnóstico por imagen
12.
Rofo ; 181(4): 367-73, 2009 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-19291605

RESUMEN

PURPOSE: Despite clinically available high-resolution CT, the detection and classification of gallstones remains a challenge in some cases. This pilot study examines whether noninvasive characterization of gallstones in vitro is possible using dual-energy analysis (DECT) of dual source CT datasets. MATERIALS AND METHODS: A total of 43 gallstones (0.4 - 1.5 cm) were examined at 80 kV, 140 kV and in the dual-energy mode. The monoenergetic datasets were examined by two independent examiners and classified as calcium, cholesterol or pigment stones. The results were compared with the pathological classification as the clinical gold standard. After creating reference images for each group via dual-energy analysis, the classification was repeated and compared with the gold standard again. RESULTS: Using the monoenergetic analysis at 80 kV, the sensitivity and specificity were 100 / 84 % and 100 / 88 % for calcium stones. For cholesterol stones the values were 54 / 89 % and 54 / 85 % and for pigment stones 70 / 80 % for both examiners. At 140 kV, the sensitivity and specificity for calcium stones were 100 / 84 % for both examiners, 46 / 92 % for cholesterol stones for both examiners and the sensitivity and specificity were 80 / 75 % and 80 / 80 % for pigment stones. Using the reference images established by DECT, both examiners were able to correctly classify all gallstones. CONCLUSION: The present data indicates that DECT is able to correctly classify Gallstones according to the clinical gold standard in vitro. Clinical studies have to demonstrate whether these results lead to optimized clinical decision making.


Asunto(s)
Cálculos Biliares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Acta Anaesthesiol Scand ; 51(10): 1314-9, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17944633

RESUMEN

AIM: To compare a new method of non-invasive determination of cardiac output based on electrical velocimetry (EV-CO) with invasive thermodilution methods. METHODS: Fifty critically ill patients were enrolled into the study. EV-CO was compared with cardiac output measured by a pulmonary artery catheter (PA-CO) in one group (n= 25) and by a femoral artery catheter (PiCCO-CO) in a second group (n= 25), by simultaneous measurements. Standard electrocardiography electrodes were used for non-invasive measurements, and EV-CO was calculated using the Bernstein-Osypka equation. The invasive measurements of PA-CO and PiCCO-CO were made by the injection of iced 0.9% saline and the recording of thermodilution curves. RESULTS: The precision values of EV-CO, PA-CO and PiCCO-CO measurements were +/- 0.46 [95% confidence interval (95% CI), +/- 0.06], +/- 0.57 (95% CI, +/- 0.09) and +/- 0.48 l/min (95% CI, +/- 0.08 l/min), respectively. The mean differences between EV-CO and PA-CO or PiCCO-CO were -0.05 +/- 0.71 and 0.22 +/- 0.78 l/min, respectively. The lower and upper limits of agreement for the comparison of EV-CO with PA-CO were -1.47 and 1.37 l/min (95% CI, +/- 0.25 l/min), respectively. In the comparison of EV-CO and PiCCO-CO, lower and upper limits of -1.34 and 1.78 l/min (95% CI, +/- 0.27 l/min) were found. The percentage errors between EV-CO and PA-CO or PiCCO-CO were 26.5% and 26.4%, respectively. CONCLUSIONS: The values of cardiac output were statistically comparable between the groups. Therefore, electrical velocimetry is a suitable method to evaluate haemodynamic variables with clinically acceptable accuracy.


Asunto(s)
Gasto Cardíaco/fisiología , Electricidad , Termodilución/métodos , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Monóxido de Carbono/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad
14.
Clin Physiol Funct Imaging ; 27(5): 309-19, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17697028

RESUMEN

Wingate test is short anaerobic exercise, performed with maximal power, whereas aerobic exercise at 85% maximal heart rate (HR(max)) may be performed for long period. Sustained HR elevations and changes in autonomic activity indices have been observed after latter kind of exercise. Several studies reported reduction in mean interval between consecutive R peaks in ECG (RRI) 1 h after Wingate test; however, underlying changes in autonomic activity remain elusive. In eight young males, RRI and heart rate variability (HRV) were measured daily over two 5-day trials. Subjects exercised on third day of each trial, measurements were taken 1 h after (i) two consecutive 30-s bouts of Wingate tests or (ii) after a 30-min exercise at 85% HR(max), with subjects in supine rest and breathing either spontaneously or at controlled rates of 6 and 15 breaths / min. RRI was significantly shorter after Wingate and submaximal exercise, reduction of high- and low-frequency components of HRV attained reliability only after Wingate tests. This pattern remained preserved for three modes of breathing: spontaneous, 6 and 15 breaths /min. After 24 and 48 h, no exercise effects were traceable. We hypothesize that (i) anaerobic exertion is followed by sustained inhibition of vagal activity, (ii) parasympathetic system plays dominant role in mediating suppression of high- and low-HRV frequency components during postexercise recovery, (iii) degree of alteration of autonomic activity caused by anaerobic and strenuous aerobic exercise may be similar and (iv) normalization of vagal activity precedes normalization of sympathetic cardiac nerves activity during final stage of postexercise recovery.


Asunto(s)
Umbral Anaerobio/fisiología , Sistema Nervioso Autónomo/fisiología , Frecuencia Cardíaca , Corazón/inervación , Esfuerzo Físico/fisiología , Adulto , Electrocardiografía , Humanos , Masculino , Recuperación de la Función , Mecánica Respiratoria , Sistema Nervioso Simpático/fisiología , Factores de Tiempo , Nervio Vago/fisiología
16.
Neurosci Lett ; 311(3): 193-7, 2001 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-11578827

RESUMEN

Chronic pain continues to impose a large burden of suffering, yet its neural correlates remain poorly understood. In sympathetically mediated chronic pain (SMP), peripheral sympathetic blockade temporarily relieves this pain, so that related neural activity can be studied without perturbing sensory inputs. We used functional magnetic resonance imaging and thermal painful stimuli applied to the chronically painful body site, before and after sympathetic blockade, to examine the cortical network of chronic pain. The chronic SMP state was associated with a widely spread prefrontal hyperactivity, increased anterior cingulate activity and decreased activity in the thalamus contralateral to the body side suffering from SMP, but was unrelated to sensorimotor activity. Ineffective sympathetic blocks, i.e. blocks that did not diminish the SMP pain, did not change the cortical responses to the painful thermal stimulus; while effective placebo resulted in similar responses to those of effective blocks. These findings provide evidence for abnormal brain responses to pain in patients with chronic SMP, which engages prefrontal/limbic networks more extensively than in acute pain-states.


Asunto(s)
Síndromes de Dolor Regional Complejo/fisiopatología , Dolor/fisiopatología , Corteza Prefrontal/fisiopatología , Sistema Nervioso Simpático/fisiopatología , Adulto , Mapeo Encefálico , Enfermedad Crónica , Síndromes de Dolor Regional Complejo/patología , Femenino , Lateralidad Funcional/efectos de los fármacos , Lateralidad Funcional/fisiología , Giro del Cíngulo/patología , Giro del Cíngulo/fisiopatología , Calor/efectos adversos , Humanos , Hiperalgesia/patología , Hiperalgesia/fisiopatología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Dolor/patología , Umbral del Dolor/efectos de los fármacos , Umbral del Dolor/fisiología , Estimulación Física/efectos adversos , Corteza Prefrontal/patología , Corteza Somatosensorial/patología , Corteza Somatosensorial/fisiopatología , Sistema Nervioso Simpático/efectos de los fármacos , Sistema Nervioso Simpático/patología , Simpaticolíticos/farmacología
19.
Neurosci Lett ; 299(1-2): 57-60, 2001 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-11166937

RESUMEN

Most brain imaging studies of pain are done using a two-state subtraction design (state-related design). More recently event-related functional magnetic reasonance imaging (fMRI) has also been used for studying pain. Both designs severely limit the application of the technology to clinical pain states. Recently we demonstrated that monitoring time fluctuations of perceived pain could be used with fMRI to identify brain regions involved in conscious, subjective perception of pain. Here we extend the methodology to demonstrate that the same approach can be used to study clinical pain states. Subjects are equipped with a finger-spanning device to continuously rate and log their perceived pain during fMRI data collection. These ratings are convolved with a canonical hemodynamic response function to generate predictor waveforms with which related brain activity can be identified. Chronic low back pain patients and a normal volunteer were used. In one series of fMRI scans the patient simply lies in the scanner and indicates spontaneous fluctuations of the subjective pain. In other fMRI scans, a straight-leg raising procedure is performed to exacerbate the back pain. In the normal volunteer, fMRI scans were done during painful and non-painful straight-leg raisings. The results indicate the feasibility of differentiating between different pain states. We argue that the approach can be generalized to identify brain circuitry underlying diverse clinical pain conditions.


Asunto(s)
Corteza Cerebral/fisiopatología , Dolor de la Región Lumbar/fisiopatología , Mapeo Encefálico , Corteza Cerebral/patología , Humanos , Dolor de la Región Lumbar/patología , Dolor de la Región Lumbar/psicología , Imagen por Resonancia Magnética , Masculino , Dimensión del Dolor/psicología , Postura/fisiología , Radiculopatía/patología , Radiculopatía/fisiopatología , Radiculopatía/psicología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA