Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
2.
Eur J Radiol ; 61(2): 315-23, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17074459

RESUMEN

PURPOSE: Prospective evaluation of diagnostic accuracy of single field-of-view contrast-enhanced MR Angiography (ceMRA) with 1.0M gadobutrol compared to intraarterial DSA in body arteries. MATERIALS AND METHODS: In an European multicenter study 179 patients underwent ceMRA and DSA. For each indication five prospectively defined vessel segments were evaluated by local investigators onsite and by three site-independent blinded readers (BR) independently. RESULTS: The agreement between ceMRA and DSA diagnosis was statistically significant in the onsite (96.6%) and blinded reader (86.6-90.2%) evaluation. Sensitivity, specificity, accuracy, positive (PPV) and negative predictive values (NPV) for detection of relevant stenosis (>50%) were calculated for the right and left internal carotid arteries, and common and external iliac arteries: Sensitivity was 95-98% (onsite) and 76-96% (BR), specificity 94-96% (onsite) and 86-94% (BR), accuracy 96% (onsite) and 87-93% (BR), NPV 98-99% (onsite) and 84-98% (BR), and PPV 79-93% (onsite) and 44-91% (BR), respectively. CONCLUSION: CeMRA of body arteries using 1.0M gadobutrol provides diagnostic information comparable to intraarterial DSA.


Asunto(s)
Angiografía de Substracción Digital , Arterias/patología , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Constricción Patológica/diagnóstico , Medios de Contraste , Gadolinio , Humanos , Masculino , Persona de Mediana Edad , Compuestos Organometálicos , Estudios Prospectivos , Sensibilidad y Especificidad , Método Simple Ciego
3.
J Magn Reson Imaging ; 22(1): 101-8, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15971183

RESUMEN

PURPOSE: To assess the diagnostic accuracy of integrated parallel acquisition technique (iPAT) in local staging of rectal carcinoma in comparison to conventional high-resolution MRI. MATERIALS AND METHODS: A total of 28 patients with a neoplasm of the rectum and 15 control patients underwent MRI of the pelvis. High-resolution images were acquired conventionally and with iPAT using a modified sensitivity encoding (mSENSE). Image quality, signal-to-noise and contrast-to-noise ratios (SNR, CNR), tumor extent, nodal status, and delineation of the circumferential resection margin (CRM) were compared. In 19 patients with a carcinoma, MR findings were correlated with the histopathological diagnosis. Tumor distance to the CRM was matched with resection specimen in 12 cases. RESULTS: The comparison of both MR techniques revealed no clinically relevant differences in tumor staging and delineation of the CRM, though SNR and CNR were significantly lower in mSENSE images. Tumor stage was concordant in 17 of 19 cases compared to histopathology. In four of nine patients with T3 and T4 carcinomas, the histopathological resection margin was < or =2 mm, in five cases MRI predicted a margin of < or =2 mm. CONCLUSION: The application of iPAT in local staging of rectal carcinoma is time-saving and does not degrade diagnostic accuracy. Tumor stage, nodal status, and the CRM can be assessed equally compared to conventional acquisition techniques.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Estadificación de Neoplasias/métodos , Neoplasias del Recto/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Ganglios Linfáticos/patología , Masculino , Persona de Mediana Edad , Neoplasias del Recto/patología , Sensibilidad y Especificidad
4.
Eur Radiol ; 14(10): 1732-42, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15378253

RESUMEN

The purpose was to combine T1-weighted 3D gradient echo sequences at low and high spatial resolution (and short and longer acquisition time, respectively) in two orientations without compromising signal/time curve analysis and to evaluate the incremental value of assessing architectural features in high resolution images in dynamic contrast-enhanced MR mammography. T1-weighted 3D-FLASH sequences in a 1.5-T scanner (512 x 256 pixel matrix at high resolution; 256 x 128 pixels at low resolution sequences, 72 slices, 1.7-mm slice thickness, TR 8.8 ms, TE 4.5 ms, flip angle 25 degrees) were acquired in a special order during a single investigation. Three observers evaluated architectural features of 36 histopathologically proven lesions using high or low resolution images independently. Architectural features of each lesion were assessed by rating on two three-point scales. Kappa statistics verified the decrease of inter-observer variability. All observers improved assessment of architectural features regarding high resolution images in transversal and coronal orientation (observer A: eight positive, three negative corrections; B: 12/5; C: 16/4). Most positive corrections resulted from improved detection of morphologic criteria of malignancy. Mean inter-observer agreement significantly (P<0.05) increased from "slight" to "moderate" (mean weighted kappa increased from 0.185 to 0.422). This protocol at the charge of slightly enlarged time for measurement offers an elegant way to improve analysis of architectural features in MRM.


Asunto(s)
Mama/patología , Medios de Contraste , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Carcinoma in Situ/diagnóstico , Carcinoma in Situ/patología , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/patología , Carcinoma Lobular/diagnóstico , Carcinoma Lobular/patología , Carcinoma Medular/diagnóstico , Carcinoma Medular/patología , Niño , Femenino , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Técnica de Sustracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA