Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

2.
J Invasive Cardiol ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38776477

RESUMEN

A 93-year-old woman with symptomatic severe aortic stenosis and normal biventricular function was referred for transcatheter aortic valve replacement (TAVR) evaluation. Cardiac computed tomography revealed safe coronary heights and multiple large calcified mobile mass-like structures attached to the aortic valve (AV), confirmed also by transesophageal echocardiography, which were thought to be prominent Lambl's excrescences.

3.
J Am Heart Assoc ; 13(11): e033931, 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38818962

RESUMEN

BACKGROUND: Patients may prefer percutaneous coronary intervention (PCI) over coronary artery bypass graft (CABG) surgery, despite heart team recommendations. The outcomes in such patients have not been examined. We sought to examine the results of PCI in patients who were recommended for but declined CABG. METHODS AND RESULTS: Consecutive patients with stable ischemic heart disease and unprotected left main or 3-vessel disease or Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery score >22 who underwent PCI after heart team review between 2013 and 2020 were included. Patients were categorized into 3 groups according to heart team recommendations on the basis of appropriate use criteria: (1) PCI-recommended; (2) CABG-eligible but refused CABG (CABG-refusal); and (3) CABG-ineligible. The primary end point was the composite of death, myocardial infarction, or stroke at 1 year. The study included 3687 patients undergoing PCI (PCI-recommended, n=1718 [46.6%]), CABG-refusal (n=1595 [43.3%]), and CABG-ineligible (n=374 [10.1%]). Clinical and procedural risk increased across the 3 groups, with the highest comorbidity burden in CABG-ineligible patients. Composite events within 1 year after PCI occurred in 55 (4.1%), 91 (7.0%), and 41 (14.8%) of patients in the PCI-recommended, CABG-refusal, and CABG-ineligible groups, respectively. After multivariable adjustment, the risk of the primary composite outcome was significantly higher in the CABG-refusal (hazard ratio [HR], 1.67 [95% CI, 1.08-3.56]; P=0.02) and CABG-ineligible patients (HR, 3.26 [95% CI, 1.28-3.65]; P=0.004) groups compared with the reference PCI-recommended group, driven by increased death and stroke. CONCLUSIONS: Cardiovascular event rates after PCI were significantly higher in patients with multivessel disease who declined or were ineligible for CABG. Our findings provide real-world data to inform shared decision-making discussions.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Masculino , Puente de Arteria Coronaria/efectos adversos , Femenino , Anciano , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/mortalidad , Persona de Mediana Edad , Resultado del Tratamiento , Estudios Retrospectivos , Factores de Riesgo , Medición de Riesgo , Selección de Paciente , Toma de Decisiones Clínicas
4.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38456886

RESUMEN

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Tomografía Computarizada Multidetector
5.
Circ Cardiovasc Interv ; 17(3): e013766, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38502723

RESUMEN

BACKGROUND: Redo-transcatheter aortic valve replacement (TAVR) can pin the index transcatheter heart valve leaflets open leading to sinus sequestration and restricting coronary access. The impact of initial implant depth and commissural alignment on redo-TAVR feasibility is unclear. We sought to determine the feasibility of redo-TAVR and coronary access after SAPIEN 3 (S3) TAVR stratified by implant depth and commissural alignment. METHODS: Consecutive patients with native valve aortic stenosis were evaluated using multidetector computed tomography. S3 TAVR simulations were done at 3 implant depths, sizing per manufacturer recommendation and assuming nominal expansion in all cases. Redo-TAVR was deemed unfeasible based on valve-to-sinotubular junction distance and valve-to-sinus height <2 mm, while the neoskirt plane of the S3 transcatheter heart valve estimated coronary access feasibility. RESULTS: Overall, 1900 patients (mean age, 80.2±8 years; STS-PROM [Society of Thoracic Surgeons Predicted Risk of Operative Mortality], 3.4%) were included. Redo-TAVR feasibility reduced significantly at shallower initial S3 implant depths (2.3% at 80:20 versus 27.5% at 100:0, P<0.001). Larger S3 sizes reduced redo-TAVR feasibility, but only in patients with a 100:0 implant (P<0.001). Commissural alignment would render redo-TAVR feasible in all patients, assuming the utilization of leaflet modification techniques to reduce the neoskirt height. Coronary access following TAV-in-TAV was affected by both index S3 implant depth and size. CONCLUSIONS: This study highlights the critical impact of implant depth, commissural alignment, and transcatheter heart valve size in predicting redo-TAVR feasibility. These findings highlight the necessity for individualized preprocedural planning, considering both immediate results and long-term prospects for reintervention as TAVR is increasingly utilized in younger patients with aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios de Factibilidad , Diseño de Prótesis , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X , Factores de Riesgo
7.
J Invasive Cardiol ; 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38547048

RESUMEN

We report the case of an 80-year-old woman with known quadricuspid aortic valve (QAV), severe aortic stenosis, and moderate-to-severe regurgitation who recently underwent a transcatheter aortic valve replacement (TAVR).

8.
Open Heart ; 11(1)2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38191233

RESUMEN

BACKGROUND: A quarter of patients with severe aortic stenosis (AS) were asymptomatic, and only a third of them survived at the end of 4 years. Only a select subset of these patients was recommended for aortic valve replacement (AVR) by the current American College of Cardiology/American Heart Association guidelines. We intended to study the effect of early AVR (eAVR) in this subset of asymptomatic patients with preserved left ventricle function. METHODS AND RESULTS: We searched PubMed and Embase for randomised and observational studies comparing the effect of eAVR versus conservative therapy in patients with severe, asymptomatic AS and normal left ventricular function. The primary outcome was all-cause mortality. The secondary outcomes were composite major adverse cardiac events (MACE) (study defined), myocardial infarction (MI), stroke, cardiac death, sudden death, the development of symptoms, heart failure hospitalisations and major bleeding. We used GRADEPro to assess the certainty of the evidence. In the randomised controlled trial (RCT) only analysis, we found no significant difference in all-cause mortality between the early aortic intervention group versus the conservative arm (CA) (incidence rate ratio, IRR (CI): 0.5 (0.2 to 1.1), I2=31%, p=0.09). However, in the overall cohort, we found mortality benefit for eAVR over CA (IRR (CI): 0.4 (0.3 to 0.7), I2=84%, p<0.01). There were significantly lower MACE, cardiac death, sudden death, development of symptoms and heart failure hospitalisations in the eAVR group. We noticed no difference in MI, stroke and major bleeding. CONCLUSION: We conclude that there is no reduction in all-cause mortality in the eAVR arm in patients with asymptomatic AS with preserved ejection fraction. However, eAVR reduces heart failure related hospitalisations and death or heart failure hospitalisations. PROSPERO REGISTRATION NUMBER: CRD42022306132.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Tratamiento Conservador/efectos adversos , Muerte Súbita Cardíaca/etiología , Insuficiencia Cardíaca/etiología , Hemorragia/etiología , Infarto del Miocardio/etiología , Accidente Cerebrovascular/etiología , Estados Unidos , Función Ventricular Izquierda , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
9.
Eur Heart J Cardiovasc Pharmacother ; 10(1): 11-19, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-37742213

RESUMEN

AIM: To assess the value of the thrombotic risk criteria proposed in the 2023 guidelines of the European Society of Cardiology (ESC) for the management of acute coronary syndrome (ACS) to predict the ischaemic risk after percutaneous coronary intervention (PCI). METHODS AND RESULTS: Consecutive patients with acute or chronic coronary syndrome undergoing PCI at a large tertiary-care center from 2014 to 2019 were included. Patients were stratified into low, moderate, or high thrombotic risk based on the ESC criteria. The primary endpoint was major adverse cardiovascular events (MACEs) at 1 year, a composite of all-cause death, myocardial infarction (MI), and stroke. Secondary endpoints included major bleeding. Among 11 787 patients, 2641 (22.4%) were at low-risk, 5286 (44.8%) at moderate risk, and 3860 (32.7%) at high-risk. There was an incremental risk of MACE at 1 year in patients at moderate (hazard ratios (HR) 2.53, 95% confidence interval (CI) 1.78-3.58) and high-risk (HR 3.39, 95% CI 2.39-4.80) as compared to those at low-risk, due to higher rates of all-cause death and MI. Major bleeding rates were increased in high-risk patients (HR 1.59, 95% CI 1.25-2.02), but similar between the moderate and low-risk group. The Harrell's C-index for MACE was 0.60. CONCLUSION: The thrombotic risk criteria of the 2023 ESC guidelines for ACS enable to stratify patients undergoing PCI in categories with an incremental 1 year risk of MACE; however, their overall predictive ability for MACE is modest. Future studies should confirm the value of these criteria to identify patients benefiting from an extended treatment with a second antithrombotic agent.


Asunto(s)
Síndrome Coronario Agudo , Cardiología , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Humanos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Inhibidores de Agregación Plaquetaria/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio/etiología , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Hemorragia/inducido químicamente , Sistema de Registros
10.
Can J Cardiol ; 40(2): 250-262, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38042339

RESUMEN

Mitral regurgitation is a prevalent valvular disease, and its management has gained increasing importance because of the aging population. Although traditional surgery remains the gold standard, the field of transcatheter therapies, including transcatheter edge-to-edge repair and, more recently transcatheter mitral valve replacement are advancing and are being explored as viable alternatives, particularly for patients at high surgical risk. It is essential to emphasize the necessity of a multidisciplinary team approach, involving specialized valve teams, imaging experts, cardiac anaesthesiologists, and other relevant specialists, is crucial in achieving optimal outcomes. Furthermore, proper execution of procedures, postprocedural care, and diligent follow-up for these patients are essential components for successful results. It is essential to underscore that traditional mitral valve surgery continues to play a significant role. Simultaneously, it is important to acknowledge the expanding array of transcatheter interventions available for this specific patient population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento
12.
Am J Cardiol ; 208: 6-12, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37806187

RESUMEN

Prognostic implications of pulmonary hypertension (PH) in low-flow low-gradient (LG) aortic stenosis (AS) after transcatheter aortic valve replacement (TAVR) remains unexplored. We aimed to investigate the impact of baseline and changes in PH after TAVR. In this single-center retrospective study, we included patients who underwent TAVR for low-flow LG AS. Patients were categorized into 2 groups: baseline pulmonary artery systolic pressure (PASP) <46 mm Hg (no-to-mild PH) and PASP ≥46 mm Hg (moderate-to-severe PH). On the basis of changes in PASP after TAVR, patients were stratified into increased (ΔPASP ≥ + 5 mm Hg), no change (-4 to +4 mm Hg), and decreased (≤ -5 mm Hg) groups. Primary end point was a composite of all-cause mortality and heart failure rehospitalization. In total, 210 patients were included, 148 in the no-to-mild PH group and 62 in the moderate-to-severe PH group. Median follow-up was 13.2 months. The moderate-to-severe PH group was at an increased risk of composite end point (adjusted hazard ratio [HR] 3.5, 95% confidence interval [CI] 1.8 to 6.9), all-cause mortality (HR 2.4, 95% CI 1.1 to 5.6), and heart failure rehospitalization (HR 8.3, 95% CI 2.9 to 23.7). There were no differences in clinical outcomes among those with increased (32%), no change (28%), and decreased (39%) PASP after TAVR. In conclusion, moderate-to-severe PH at baseline is an independent predictor of worse clinical outcomes in patients with low-flow LG AS who undergo TAVR, and this cohort of patients do not seem to derive the benefits of postoperative reduction of PASP.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Hipertensión Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Hipertensión Pulmonar/epidemiología , Hipertensión Pulmonar/etiología , Pronóstico , Estudios Retrospectivos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Índice de Severidad de la Enfermedad
15.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-37438029

RESUMEN

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Catéteres
16.
Am J Cardiol ; 201: 252-259, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37393727

RESUMEN

Rotational atherectomy (RA) is widely used in the percutaneous treatment of heavily calcified coronary artery lesions in patients with chronic coronary syndromes (CCS). However, the safety and efficacy of RA in acute coronary syndrome (ACS) is not well established and is considered a relative contraindication. Therefore, we sought to evaluate the efficacy and safety of RA in patients presenting with non-ST-elevation myocardial infarction (NSTEMI), unstable angina (UA), and CCS. Consecutive patients who underwent percutaneous coronary intervention with RA between 2012 and 2019 at a tertiary single center were included. Patients presenting with ST-elevation myocardial infarction (MI) were excluded. The primary end points of interest were procedural success and procedural complications. The secondary end point was the risk of death or MI at 1 year. A total of 2,122 patients who underwent RA were included, of whom 1,271 presented with a CCS (59.9%), 632 presented with UA (29.8%), and 219 presented with NSTEMI (10.3%). Although an increased rate of slow-flow/no-reflow was noted in the UA population (p = 0.03), no significant difference in procedural success or procedural complications, including coronary dissection, perforation, or side-branch closure, was noted (p = NS). At 1 year, there were no significant differences in death or MI between CCS and non-ST-elevation ACS (NSTE-ACS: UA + NSTEMI; adjusted hazard ratio 1.39, 95% confidence interval 0.91 to 2.12); however, patients who presented with NSTEMI had a higher risk of death or MI than CCS (adjusted hazard ratio 1.79, 95% confidence interval 1.01 to 3.17). Use of RA in NSTE-ACS was associated with similar procedural success without an increased risk of procedural complications compared with patients with CCS. Although patients presenting with NSTEMI remained at higher risk of long-term adverse events, RA appears to be safe and feasible in patients with heavily calcified coronary lesions presenting with NSTE-ACS.


Asunto(s)
Síndrome Coronario Agudo , Aterectomía Coronaria , Infarto del Miocardio sin Elevación del ST , Intervención Coronaria Percutánea , Humanos , Aterectomía Coronaria/efectos adversos , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/cirugía , Infarto del Miocardio sin Elevación del ST/etiología , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/cirugía , Síndrome Coronario Agudo/etiología , Angina Inestable/epidemiología , Angina Inestable/cirugía , Angina Inestable/tratamiento farmacológico
18.
Front Cardiovasc Med ; 10: 1130354, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37351289

RESUMEN

Aim: Transfemoral Trans-catheter Aortic Valve Replacement (TF-TAVR) is a safe and effective therapy compared with surgical aortic valve replacement (SAVR) in patients across all risk profiles using balloon-expandable valves (BEV) and self-expanding valves (SEV). Our aim was to compare safety and efficacy of BEV vs. SEV in high-risk patients undergoing TF-TAVR. Methods and results: We searched PubMed, EMBASE, Clinicaltrials.gov, Scopus, and Web of sciences for studies on patients with severe aortic stenosis undergoing TAVR. Primary outcome was 30-day all-cause mortality. Secondary outcomes defined by Valve Academic Research Consortium 2 (VARC-2) criteria were also examined. Six studies with 2,935 patients (1,439 to BEV and 1,496 to SEV) were included. BEV was associated with lower risk of all-cause mortality (2.2% vs. 4.5%; RR: 0.51; 95% CI: 0.31-0.82; p < 0.006) and cardiovascular mortality [(2.5% vs. 4.3%; RR: 0.54; 95% CI: 0.32-0.90; p = 0.01) at 30 days compared with SEV. Implantation of more than one valve per procedure (0.78% vs. 5.11%; RR: 0.15; 95% CI: 0.07-0.31; p < 0.00001), and moderate/severe AR/PVL (2.5% vs. 9.01%; RR: 0.3; 95% CI: 0.17-0.48); p < 0.00001) were also lower in the BEV arm. Conclusion: BEV TAVR is associated with reduced all-cause mortality (High level of GRADE evidence), cardiovascular mortality (very low level) at 30 days compared with SEV TAVR in high surgical risk patients. Data are necessary to determine if the difference in outcomes persists in longer-term and if the same effects are seen in lower-risk patients. Systematic Review Registration: identifier, CRD42020181190.

20.
Cardiovasc Revasc Med ; 49: 28-33, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36624012

RESUMEN

INTRODUCTION: The Seattle Angina Questionnaire (SAQ-7) quantifies the impact of angina on patient functionality and quality of life. There is scarce data on the impact of social determinants and comorbidities on SAQ-7 in patients undergoing percutaneous coronary intervention (PCI) with planned staged PCI. METHODS: Patients completed a SAQ-7 before each PCI. Multivariable regression analysis was performed to study the impact of social determinants, comorbidities, and procedural characteristics on SAQ-7 scores at index PCI and at the time of the staged PCI. RESULTS: 531 patients were studied. Female sex, non-White race, coronary artery bypass graft history (CABG), and chronic lung disease were associated with lower baseline SAQ-7 scores. Overall, SAQ-7 increased between index procedure and staged PCI (11.9 ± 23.4). Body mass index (BMI) and the treatment of bifurcation lesions were independently associated with improvement of SAQ-7 between PCIs. Post-intervention, neither sex nor race was independently associated with changes in SAQ-7 scores. CONCLUSION: Different disparities and comorbid factors affect SAQ-7 before and after PCI. After revascularization, sex and race were not independent predictors of SAQ-7 improvement.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Femenino , Intervención Coronaria Percutánea/efectos adversos , Calidad de Vida , Angina de Pecho/terapia , Angina de Pecho/cirugía , Puente de Arteria Coronaria/efectos adversos , Encuestas y Cuestionarios , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...