Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Exp Gerontol ; 60: 12-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25218444

RESUMEN

Individual lifespans of isogenic organisms, such as Caenorhabditis elegans nematodes, fruit flies, and mice, vary greatly even under identical environmental conditions. To study the molecular mechanisms responsible for such variability, we used an assay based on the measurement of post-reproductive nematode movements stimulated by a moderate electric field. This assay allows for the separation of individual nematodes based on their speed. We show that this phenotype could be used as a biomarker for aging because it is a better predictor of lifespan than chronological age. Fast nematodes have longer lifespans, fewer protein carbonyls, higher heat-shock resistance, and higher transcript levels of the daf-16 and hsf-1 genes, which code for the stress response transcription factors, than slow nematodes. High transcript levels of the genes coding for heat-shock proteins observed in slow nematodes correlate with lower heat-shock resistance, more protein carbonyls, and shorter lifespan. Taken together, our data suggests that shorter lifespan results from early-life damage accumulation that causes subsequent faster age-related deterioration.


Asunto(s)
Proteínas de Caenorhabditis elegans/genética , Caenorhabditis elegans/genética , Caenorhabditis elegans/fisiología , Genes de Helminto , Proteínas de Choque Térmico/genética , Longevidad/genética , Longevidad/fisiología , Envejecimiento/genética , Envejecimiento/fisiología , Animales , Proteínas de Caenorhabditis elegans/metabolismo , Estimulación Eléctrica , Proteínas de Choque Térmico/metabolismo , Respuesta al Choque Térmico , Ratones , Actividad Motora , Carbonilación Proteica , Transcriptoma
2.
Ultrasound Obstet Gynecol ; 34(6): 673-7, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19859908

RESUMEN

OBJECTIVES: The main goal was to develop a reproducible method for estimating the diffusion of water in human fetal lung tissue using diffusion-weighted imaging (DWI). A secondary objective was to determine the relationship of the apparent diffusion coefficients (ADCs) in the fetal lung to menstrual age and total lung volume. METHODS: Normal pregnant volunteers were scanned on a 1.5-Tesla (T) magnetic resonance imaging (MRI) system. The MRI system was equipped with 40-mT/m gradients (slew rate 200 T/m/s, rise time 0.2 ms). A six-channel body array coil was used for signal reception. Single-shot DWI utilized TE/TR 125/3400 ms, slice thickness 4 mm, field of view 280 mm x 280 mm, interslice gap 0.8 mm and a matrix of 128 x 128. The voxel size was 2.5 mm x 2.5 mm x 4.0 mm. Two b-values (0 and 1000) were chosen along three orthogonal directions. ADC maps were created using assigned b-values. Simple linear regression was performed with Pearson correlation coefficient. Interexaminer and intraexaminer bias, and 95% limits of agreement (LOA) were determined using Bland-Altman plots. RESULTS: Forty-seven scans were performed at a mean +/- SD of 29.2 +/- 4.5 weeks. The median coefficient of variation for ADC was 5.6% (interquartile range, 4.0-8.1%). No differences in ADC values were found between right and left lungs. Normally distributed ADC measurements were not significantly correlated with either total lung volume (r(2) = 0.0001, P = 0.94) or menstrual age (r(2) = 0.003, P = 0.70). The mean ADC value was 1.75 (95% CI, 1.63-1.86). Mean +/- SD intraexaminer bias was -0.15 +/- 2.3 (95% LOA, -4.7 to + 4.4) and interexaminer bias was 2.2 +/- 3.5 (95% LOA, -4.7 to + 9.1). CONCLUSIONS: Our findings suggest that ADC measurements of the fetal lung are reproducible between blinded examiners and are independent of menstrual age, as well as lung volume.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Desarrollo Fetal/fisiología , Pulmón/fisiología , Adulto , Femenino , Edad Gestacional , Humanos , Pulmón/diagnóstico por imagen , Pulmón/embriología , Embarazo , Valores de Referencia , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...