Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Orthopadie (Heidelb) ; 51(9): 694-698, 2022 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-35969247

RESUMEN

Digitization in hospitals is developing rapidly. The aim of many tools is to save time and better interlink interprofessional teams. Digitization also harbors dangers which, in the best-case scenario, can be identified and resolved in good time. This article describes the path of an orthopedic department in the context of a maximum-supply clinic to electronic patient files.


Asunto(s)
Instituciones de Atención Ambulatoria , Hospitales , Electrónica , Humanos
2.
Eur Radiol ; 12(9): 2236-41, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12195475

RESUMEN

Automation in colorectal mass detection is achieved as soon as the voxels representing colorectal masses can be automatically segmented. We tested the Hounsfield (HU) value in intensely contrast enhanced high-resolution CT colonography for automated segmentation of colorectal masses in 18 patients with 35 polyps (28 < 10 mm, 7 > or = 10 mm) and 7 carcinomas. Mean HU values of the colonic wall and masses were determined to deduce a gradient threshold for a segmentation process, which encodes the voxels bordering the colonic lumen with a colour ranging in intensity from 0 to 100% according to the selected gradient threshold range in the volume rendering. The results of the automated segmentation process were superimposed on a virtual double contrast and endoscopic display and validated through correlation with morphology. Mean HU values and their standard deviations for the colonic wall, polyps < 10 mm, polyps > or = 10 mm and carcinomas were 63 +/- 24, 154 +/- 38, 116 +/- 41 and 108+/-29 HU, respectively. A gradient threshold ranging from 90 to 160 HU resulted in colour pools in 6 of 7 of polyps > or = 10 mm, and 6 of 7 carcinomas that were significant enough to prospectively guide the reader's attention to these masses. Due to the superposition of "false-positive" voxels in the projection view, the virtual endoscopic perspective was superior to the virtual double contrast display for controlling the segmentation results. The HU value is promising for automated segmentation of colorectal masses but needs to be combined with morphological parameters to render automated colorectal mass detection more accurate. Further refinements of the method with subsequent analysis of its accuracy, as well as analogue studies with contrast-enhanced MRI, appear warranted. More information at http://www.multiorganscreening.org


Asunto(s)
Colonografía Tomográfica Computarizada , Diagnóstico por Computador , Anciano , Neoplasias del Colon/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Medios de Contraste , Humanos , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA