Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
J Exp Orthop ; 11(3): e12030, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38774580

RESUMEN

Purpose: This study aimed to evaluate the effects and interactions of training level and different joints on the outcomes of cadaveric arthroscopic training courses for orthopaedic residents. Methods: This prospective study enrolled 16 orthopaedic residents who voluntarily participated in a cadaveric training programme involving the shoulder, elbow, wrist, knee and ankle joints. Outcomes were quantitatively assessed using task-specific checklists and the Arthroscopic Surgery Skill Evaluation Tool. Two-way analysis of variance (ANOVA) was conducted to determine the significance of the interactions between joint and years of training. Results: Resident scores significantly increased after the dedicated lectures in all five joints (p = 0.003 for the shoulder module, p < 0.001 for the other joints). Two-way ANOVA revealed that the progress made after the dedicated lectures was significantly impacted by the joint (p = 0.006) and training level × joint interaction (p = 0.005) but not by the training level (p = 0.47). The simple effect of the joint was examined using Sidak's multiple comparison test. Among junior residents, the dedicated lectures resulted in more substantial progress in elbow and wrist arthroscopy when compared to shoulder arthroscopy (p = 0.020 and p = 0.043, respectively). Conclusions: The results suggest that, in cadaveric arthroscopic training courses for orthopaedic residents, training outcomes are primarily impacted by the specific joint being trained rather than the training level. Specifically, junior residents demonstrated greater improvement with training in procedures that are less commonly encountered during on-the-job training, such as elbow and wrist arthroscopy. Clinical Relevance: These findings suggest the need to prioritise wrist and elbow arthroscopic training for junior residents to optimise educational outcomes. Level of Evidence: Level III.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38762151

RESUMEN

BACKGROUND: All-suture buttons (ASB) and interference screw (IS) are commonly utilized in the inlay subpectoral biceps tendon tenodesis. However, the biomechanical characteristics of these two methods have not been compared directly. The aim of present study was to compare the biomechanical properties of ASB versus IS for inlay subpectoral biceps tendon tenodesis in a human cadaveric model. METHODS: Sixteen fresh-frozen human cadaveric shoulders were randomly divided into two experimental inlay biceps tenodesis groups: ASB or IS. After tenodesis, every specimen was preloaded at 5 N for 2 minutes, followed with a cyclic loading test from 5 to 70 N for 500 load cycles. Then the load-to-failure test was performed. Afterwards, the humerus was placed in a cylinder tube and secured with anchoring cement. Lastly, a two-point bending test was performed to determine the strength of the humerus. Destructive axial force was applied, and the failure strength and displacement were recorded. RESULTS: No difference in stiffness was observed between the two groups (ASB=27.4 ± 3.5 N/mm vs IS= 29.7 ± 3.0 N/mm; P=.270). Cyclic displacement was significantly greater in the ASB group (6.8 ± 2.6 mm) than the IS group (3.8 ± 1.1 mm; P=.021). In terms of failure load, there were no statistical differences among the two groups (P=.234). The ASB group was able to withstand significantly greater displacement (11.9 ± 1.6 mm) before failure than the IS group (7.8 ± 1.5mm; P=.001). During the humeral bending test, the ASB group exhibited significantly greater maximal load (2354.8 ± 285.1 N vs 2086.4 ± 296.1 N; P=.046) and larger displacement (17.8 ± 2.8mm vs 14.1± 2.8 mm; P=.027) before fracture. CONCLUSIONS: In inlay subpectoral bicep tenodesis, ASB fixation appears to offer comparable stiffness and failure load to that of IS fixation. Additionally, the ASB group exhibited greater resistance to load and displacement before humeral fracture. However, the ASB group did demonstrate increased cyclic displacement compared to IS group.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38642872

RESUMEN

PURPOSE: To identify and quantify the factors associated with the reparability of rotator cuff tears (RCTs). METHODS: PubMed, Scopus, and Web of Science databases were searched for clinical studies published in English focusing on RCT reparability by using the keywords "rotator cuff tear" and "reparability". A meta-analysis was conducted if ≥3 studies examined the same factor and provided enough data to assess RCT reparability. Quality assessment was completed using the QUADAS-2 tool. RESULTS: Eighteen studies (2700 patients) were enrolled, and 26 factors were included in the meta-analysis. The dichotomous variables associated with irreparability were Patte stage 3 (Odds ratio (OR): 8.0, 95% CI: 4.3-14.9), massive tear versus large tear (OR: 3.1, 95% CI: 1.3-7.2), Goutallier stage for each tendon, and tangent sign (OR: 11.1, 95% CI: 4.3-28.4). The continuous variables associated with irreparability were age (Mean difference (MD): 3.25, 95% CI: 1.4-5.1), mediolateral tear size (MD: 12.3, 95% CI: 5.8-18.9), anteroposterior tear size (MD: 10.4, 95% CI: 5.2-15.6), acromiohumeral distance on X-ray (MD: -2.3, 95% CI: -3.0 to -1.6) and magnetic resonance imaging (MD: -1.8, 95% CI: -2.8 to -0.9), and inferior glenohumeral distance on MRI (MD: 2.2, 95% CI: 1.4-3.0). CONCLUSION: This study revealed that older age, larger tear size, severe fatty infiltration, muscle atrophy, and advanced superior migration of the humeral head were strongly associated with irreparable RCTs. Conversely, clinical symptoms provided limited information for predicting reparability. Additionally, the tangent sign emerged as a powerful and simple tool for individual prediction, and several quantitative scoring systems also proved useful.

4.
Bone Jt Open ; 5(3): 227-235, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38493798

RESUMEN

Aims: The optimal management of posterior malleolar ankle fractures, a prevalent type of ankle trauma, is essential for improved prognosis. However, there remains a debate over the most effective surgical approach, particularly between screw and plate fixation methods. This study aims to investigate the differences in outcomes associated with these fixation techniques. Methods: We conducted a comprehensive review of clinical trials comparing anteroposterior (A-P) screws, posteroanterior (P-A) screws, and plate fixation. Two investigators validated the data sourced from multiple databases (MEDLINE, EMBASE, and Web of Science). Following PRISMA guidelines, we carried out a network meta-analysis (NMA) using visual analogue scale and American Orthopaedic Foot and Ankle Score (AOFAS) as primary outcomes. Secondary outcomes included range of motion limitations, radiological outcomes, and complication rates. Results: The NMA encompassed 13 studies, consisting of four randomized trials and eight retrospective ones. According to the surface under the cumulative ranking curve-based ranking, the A-P screw was ranked highest for improvements in AOFAS and exhibited lowest in infection and peroneal nerve injury incidence. The P-A screws, on the other hand, excelled in terms of VAS score improvements. Conversely, posterior buttress plate fixation showed the least incidence of osteoarthritis grade progression, postoperative articular step-off ≥ 2 mm, nonunions, and loss of ankle dorsiflexion ≥ 5°, though it underperformed in most other clinical outcomes. Conclusion: The NMA suggests that open plating is more likely to provide better radiological outcomes, while screw fixation may have a greater potential for superior functional and pain results. Nevertheless, clinicians should still consider the fragment size and fracture pattern, weighing the advantages of rigid biomechanical fixation against the possibility of soft-tissue damage, to optimize treatment results.

5.
Reg Anesth Pain Med ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38388020

RESUMEN

BACKGROUND: Phantom limb pain (PLP) frequently affects individuals with limb amputations. When PLP evolves into its chronic phase, known as chronic PLP, traditional therapies often fall short in providing sufficient relief. The optimal intervention for chronic PLP remains unclear. OBJECTIVE: The objectives of this network meta-analysis (NMA) were to examine the efficacy of different treatments on pain intensity for patients with chronic PLP. EVIDENCE REVIEW: We searched Medline, EMBASE, Cochrane CENTRAL, Scopus, and CINAHL EBSCO, focusing on randomized controlled trials (RCTs) that evaluated interventions such as neuromodulation, neural block, pharmacological methods, and alternative treatments. An NMA was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The primary outcome was pain score improvement, and the secondary outcomes were adverse events. FINDINGS: The NMA, incorporating 12 RCTs, indicated that neuromodulation, specifically repetitive transcranial magnetic stimulation, provided the most substantial pain improvement when compared with placebo/sham groups (mean difference=-2.9 points, 95% CI=-4.62 to -1.18; quality of evidence (QoE): moderate). Pharmacological intervention using morphine was associated with a significant increase in adverse event rate (OR=6.04, 95% CI=2.26 to 16.12; QoE: low). CONCLUSIONS: The NMA suggests that neuromodulation using repetitive transcranial magnetic stimulation may be associated with significantly larger pain improvement for chronic PLP. However, the paucity of studies, varying patient characteristics across each trial, and absence of long-term results underscore the necessity for more comprehensive, large-scale RCTs. PROSPERO REGISTRATION NUMBER: CRD42023455949.

6.
Arthroscopy ; 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38395267

RESUMEN

PURPOSE: To evaluate the correlation between suture contamination and rotator cuff tendon retear after arthroscopic rotator cuff repair. METHODS: Patients undergoing primary arthroscopic rotator cuff repair from April 1, 2020, to September 30, 2022, were enrolled. Those younger than 18 years, with a history of shoulder surgeries or shoulder infection episodes, or who declined participation were excluded. A 5-cm section of the first-cut suture, originating from the anchor eyelet ends, in each rotator cuff repair surgery was subjected to bacteria culture and polymerase chain reaction analysis. Patients with positive culture findings were matched 1:1 to those with negative culture reports based on age, sex, tear size as well as involved tendons, preoperative fatty infiltration grade (Goutallier grade), and preoperative muscle atrophy grade (Warner score). Postoperative rotator cuff tendon retear assessments were conducted at the 6-month mark using the Sugaya classification via magnetic resonance imaging. The Wilcoxon signed-rank test was used for matched-pair comparisons between the groups. RESULTS: A total of 141 patients (60 men and 81 women) with a mean age of 61.0 ± 8 years were finally enrolled. Twenty-six patients (18 men and 8 women) had a positive culture, while 115 patients (42 men and 73 women) had a negative culture. After the propensity score matching process, 24 culture-negative patients (16 men and 8 women) were selected as the culture-negative group. Age, fatty infiltration grade, and muscle atrophy grade were not significantly different between matched groups. The retear grade in the culture-positive group was significantly higher than that in the culture-negative group (P = .020) under the matched-pair comparison. Cutibacterium acnes was the most prevalent bacterial species responsible for suture contamination. CONCLUSIONS: The matched-pair analysis revealed that the presence of bacterial contamination on sutures was associated with a higher risk of retear on magnetic resonance imaging following arthroscopic rotator cuff repair. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

7.
Orthop J Sports Med ; 12(1): 23259671231222505, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38274013

RESUMEN

Background: A coracoclavicular (CC) fixation technique using an all-suture anchor with the assistance of fluoroscopy can prevent iatrogenic anterior deltoid detachment from the clavicle; however, soft anchor pullout has been reported as a complication. Purpose: To compare the biomechanical properties of conventional metallic and all-suture anchors for CC suture fixation. Study Design: Controlled laboratory study. Methods: A total of 24 fresh-frozen cadaveric specimens were divided into 2 groups: metal anchor group (group M) and all-suture anchor group (group A). In group M, 5.0-mm metallic suture anchors were used for CC fixation, whereas 2.8-mm all-suture anchors were used in group A. The prepared specimens were mounted on a materials testing machine. After preconditioning at 0 to 20 N for 10 cycles, the specimens were subjected to cyclic loading from 20 to 70 N for 1000 cycles. Finally, all the specimens were loaded to failure. Cyclic elongation, linear stiffness, ultimate load, and failure modes were recorded, and the Mann-Whitney U test was used to compare nonparametric parameters between the 2 groups. Results: All of the specimens completed the cyclic loading test. The elongation after cyclic loading in group M (1.6 ± 0.6 mm) was significantly smaller compared with that in group A (2.5 ± 1.2 mm) (P = .02). No between-group differences were found in linear stiffness (42 ± 17 N/mm in group M and 41 ± 17 N/mm in group A). The ultimate failure load in group M (263 ± 66 N) was significantly greater than that in group A (177 ± 76 N) (P = .02). All specimens failed because of suture anchor pullout. Conclusion: The use of all-suture anchors in CC fixation resulted in significantly greater cyclic displacement and smaller ultimate failure load than that of metallic anchors. Clinical Relevance: Understanding the most biomechanically sound suture anchor may assist in lowering the risk of clinical failure in CC fixation and repair.

8.
Orthop J Sports Med ; 12(1): 23259671231220384, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38213505

RESUMEN

Background: The coronal lateral collateral ligament (LCL) sign (the entire LCL being seen in 1 coronal slice on a magnetic resonance imaging [MRI] scan), is a new secondary sign of anterior cruciate ligament (ACL) tear. Purpose: To (1) evaluate the coronal LCL sign in adults with ACL tears and (2) compare the magnitude of the MRI scan parameters between adolescent and adult ACL-deficient knees with positive coronal LCL signs. Study Design: Cross-sectional study; Level of evidence: 3. Methods: We retrospectively reviewed patients who underwent ACL reconstruction between February 1, 2013, and May 31, 2021, and divided them into adolescent (10-18 years) and adult (>18 years) groups. Tibial translation, femorotibial rotation, and presence of the coronal LCL sign were evaluated using MRI. The static femorotibial position parameters were also compared between positive and negative coronal LCL sign groups. Independent Student t tests were used to identify statistically significant differences for continuous variables, whereas the categorical variables were compared using the chi-square test. Results: A total of 65 adolescents and 300 adults with ACL tears were identified. The coronal LCL sign was present in a similar percentage of adolescents and adults with ACL tears (57% vs 58%; P = .873). The anterior tibial translation (ATT) in patients with positive coronal LCL signs (adolescents, 7.9 ± 3.4 mm; adults, 6.6 ± 3.5 mm) was significantly greater compared with those with negative signs (adolescents, 1.5 ± 2.6 mm, P < .001; adults, 2.3 ± 4.2 mm, P < .001). Femorotibial rotation was also statistically greater in positive coronal LCL sign groups (adolescents, 6.4°± 5.6°; adults, 7.0°± 5.0°) compared with negative sign groups (adolescents, 0.7°± 4.7°, P < .001; adults, 3.5°± 4.2°, P < .001). Conclusion: The occurrence of the coronal LCL sign on MRI scans was comparable between adolescents and adults with ACL-deficient knees. The presence of the LCL sign was associated with a greater ATT and femorotibial rotation in both adolescents and adults with ACL tears.

9.
J Bone Joint Surg Am ; 106(4): 356-367, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38015923

RESUMEN

BACKGROUND: Clubfoot, or congenital talipes equinovarus deformity, is a common anomaly affecting the foot in infants. However, clinical equipoise remains between different interventions, especially those based on the Ponseti method. The aim of this study was to examine the clinical outcomes of the various interventions for treating idiopathic clubfoot. METHODS: Searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, Scopus, and CINAHL were conducted. Randomized controlled trials comparing different interventions, including the Ponseti method, accelerated Ponseti method, Ponseti method with botulinum toxin type A (Botox) injection, Ponseti method with early tibialis anterior tendon transfer (TATT), Kite method, and surgical treatment, were included. Network meta-analyses (NMAs) were conducted according to the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) reporting guidelines. The primary outcomes were the change in total Pirani score and maximal ankle dorsiflexion. Secondary outcomes were the number of casts, time in casts, and rates of tenotomy, total complications, relapse, adverse events, and additional required major surgery. RESULTS: Eleven randomized controlled trials involving 740 feet were included. According to the SUCRA (surface under the cumulative ranking curve)-based relative ranking, the Ponseti method was associated with the best outcomes in terms of Pirani score changes, maximal ankle dorsiflexion, number of casts, adverse events, and total complications, whereas the accelerated Ponseti method was associated with the best outcomes in terms of time in casts and tenotomy rate. Early TATT ranked best in terms of relapse rate. The Ponseti method with Botox injection was associated with the best outcomes in terms of the need for additional major surgery. CONCLUSIONS: The NMAs suggest that the Ponseti method is the optimal treatment overall, despite potential drawbacks such as longer time in casts and higher rates of tenotomy, relapse, and the need for additional surgery compared with other modified approaches. Therefore, clinicians should consider how treatments can be tailored individually. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Tendón Calcáneo , Toxinas Botulínicas Tipo A , Pie Equinovaro , Lactante , Humanos , Pie Equinovaro/cirugía , Pie Equinovaro/tratamiento farmacológico , Metaanálisis en Red , Toxinas Botulínicas Tipo A/uso terapéutico , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Tenotomía/métodos , Tendón Calcáneo/cirugía , Recurrencia , Moldes Quirúrgicos
10.
BMC Musculoskelet Disord ; 24(1): 952, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38066535

RESUMEN

BACKGROUND: The definition of irreparable rotator cuff tear (IRCT) is controversial. This scoping review provides definitions used to describe IRCT in the literature. This scoping review (1) identified criteria used in the definition of IRCT and (2) investigated the current state of those criteria in prospective surgical therapeutic trials. METHODS: This scoping review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews. PubMed, Scopus, and Web of Science were searched in March 2023. Studies were screened against predetermined inclusion and exclusion criteria. Criteria regarding clinical symptoms, preoperative images, and intraoperative findings were captured respectively. RESULTS: A total of 41 prospective studies were eligible for inclusion, and 35 studies (85.4%) defined IRCT. IRCT was defined on the basis of the following main criteria: preoperative image findings (28/35), intraoperative findings (24/35), and symptoms (16/35). With regard to preoperative images, IRCT was mainly defined on the basis of retraction of the tendon in the coronal plane (22/28), the severity of fatty degeneration (19/28), and ruptured tendon number or width of the defect in the sagittal plane (17/28). CONCLUSION: This scoping review highlights the lack of a standardized definition for IRCT in clinical practice, with common predictive criteria including a duration of over 6 months, retraction beyond 5 cm, Goutallier grade 3 fatty infiltration, and the rupture of two or more tendons. However, surgeons should apply more than one criterion when examining preoperative images and confirm reparability during surgery. A more objective manner of evaluating intraoperative reparability is necessary.


Asunto(s)
Lesiones del Manguito de los Rotadores , Humanos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Estudios Prospectivos , Imagen por Resonancia Magnética , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Rotura/cirugía , Artroscopía/métodos , Estudios Retrospectivos
11.
SICOT J ; 9: 36, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38059859

RESUMEN

INTRODUCTION: Geriatric fractures including distal femur and hip fractures are associated with high mortality rates. Currently, prognostic factors for in-hospital postoperative mortality are not identified. We aimed to evaluate overall in-hospital mortality and related potential risk factors in elderly patients who underwent distal femur fracture surgery. MATERIALS AND METHODS: A retrospective cohort study of patients older than 60 years, who underwent distal femur fracture surgery between January 01, 2003, and December 31, 2021, was conducted. A case-control study was conducted to compare two age-matched groups of elderly patients of equivalent ages at a 1:4 ratio. The in-hospital mortality rate was calculated and potential confounders were compared between groups. RESULTS: A total of 170 patients were enrolled; five died during hospital stay after undergoing surgery, yielding a 2.94% in-hospital mortality rate. Twenty patients who did not die were included in the control group. Patients' demographics were similar. The case-control comparison showed that the time from injury to surgery, preoperative hemoglobin level, estimated glomerular filtration rate (eGFR), and white blood cell count were significant factors correlated with in-hospital mortality. DISCUSSION: The overall in-hospital mortality rate was 2.94%. Significant risk factors for in-hospital mortality included a longer time from injury to surgery, lower preoperative hemoglobin level and eGFR, and higher preoperative white blood cell count. In conclusion, preoperative comprehensive geriatric assessment, including cognitive, nutritional, and frailty status, should also be considered in the elderly fracture care model.

12.
Front Physiol ; 14: 1178557, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37637142

RESUMEN

Objective: This study investigated the neuromuscular control of increasing and releasing force in patients with chronic lateral epicondylitis (CLE). Methods: Fifteen patients with CLE (10 males, 5 females, 46.5 ± 6.3 years) and fifteen healthy participants (9 males, 6 females, 45.3 ± 2.5 years) participated in this study. In addition to power grip and maximal voluntary contraction (MVC) of wrist extension, force fluctuation dynamics and characteristics of inter-spike intervals (ISI) of motor units (MUs) with various recruitment thresholds in the extensor carpi radialis brevis (ECRB) and extensor carpi radialis longus (ECRL) during a designated force-tracking task with a trapezoidal target (0%-75%-0% MVC) were assessed. Results: Besides a smaller MVC of wrist extension, the patients exhibited significantly greater task errors (p = 0.007) and force fluctuations (p = 0.001) during force increment than the healthy counterparts. Nevertheless, no force variables significantly differed between groups during force release (p > 0.05). During force increment, the amplitudes of the motor unit action potential of the ECRB and ECRL muscles of the patients were smaller than those of the heathy counterparts (p < 0.001). The patient group also exhibited a higher percentage of motor units (MU) with lower recruitment threshold (<5% MVC) in the ECRL/ECRB muscles and a lower percentage of MU with higher recruitment threshold (>40% MVC) in the ECRB muscle, compared to the healthy group. During force increment, the patient group exhibited a higher rate of decrease in inter-spike intervals (ISIs) of motor units with lower recruitment thresholds (<10% MVC) in the ECRB and ECRL muscles, compared to the control group (p < 0.005). Conclusion: The patients with CLE exhibited more pronounced impairment in increasing force than in releasing force. This impairment in increasing force is attributed to deficits in tendon structure and degenerative changes in the larger motor units of the wrist extensors. To compensate for the neuromuscular deficits, the rate of progressive increase in discharge rate of the remaining smaller motor units (MUs) is enhanced to generate force. Significance: The deficits in neuromuscular control observed in CLE with degenerative changes cannot be fully explained by the experimental pain model, which predicts pain-related inhibition on low-threshold motor units.

13.
J Exp Orthop ; 10(1): 58, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37261559

RESUMEN

PURPOSE: This study aimed to comprehensively review the existing evidence concerning surgical treatment of inferior pole fractures of the patella and to report the outcomes and complications of different fixation techniques. METHOD: This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Searches of PubMed, Scopus, and Web of Science were conducted in March 2023. Studies were screened against predecided inclusion and exclusion criteria. The extracted data included fracture characteristics, surgical techniques, and radiographic and functional outcomes. The Methodological Index for Non-Randomized Studies (MINORS) quality assessment tool was used to assess the eligible literature. The primary outcome was postoperative range of motion of different surgical methods, and the secondary outcomes were other clinical results and complications. RESULTS: A total of 42 studies satisfied all the inclusion criteria and were deemed suitable for review. Fourteen case-control studies and 28 case series were selected, for a total of 1382 patients with a mean age of 51.0 years (range = 11-90). The follow-up period ranged from 6 to 300 months. The surgical techniques were categorized based on the device used as follows: (1) rigid fixation device; (2) tensile fixation device; (3) mixed device; and (4) extra-patella device. CONCLUSION: Regarding the outcomes following surgical treatment of inferior pole fractures of the patella, the postoperative range of motion (ROM) of each technique ranged from 120° to 135°, with the exception of that involving the patellotibial wire which had poorer outcomes. The lowest functional score was also found in those using the patellotibial wire. Complications after surgery are rare, but approximately half of the patients required additional surgery for implant removal, particularly those whose initial surgery involved rigid fixation devices. It's worth noting that bony fragment excision is no longer recommended, and the combined use of multiple surgical devices is now more common.

14.
Orthop J Sports Med ; 11(6): 23259671231175873, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37347016

RESUMEN

Background: Coracoacromial ligament (CAL) degeneration is thought to be a factor in external impingement in bursal-sided rotator cuff tears, but CAL release is associated with adverse effects. Purpose: To investigate the association between CAL degeneration and the patterns of massive rotator cuff tears using multiple modalities and to assess the effect of CAL degeneration on supraspinatus tendon retear rates. Study Design: Cohort study; Level of evidence, 2. Methods: The authors prospectively recruited 44 patients who had undergone arthroscopic rotator cuff repair without acromioplasty or CAL release. Preoperative radiographs and magnetic resonance imaging (MRI) scans were reviewed to determine acromial morphology and CAL thickness, respectively. Rotator cuff tears were categorized as isolated supraspinatus or massive (involvement of ≥2 tendons), with massive tears categorized using the Collin classification. Acromial degeneration was analyzed using the Copeland-Levy classification. The CAL was biopsied intraoperatively and histologically analyzed using the Bonar score. At 6-month follow-up, the integrity of the repaired supraspinatus tendon was analyzed on MRI using the Sugaya classification. Finally, the associations among CAL degeneration, rotator cuff tear pattern, and arthroscopic grading were investigated. Results: Patients with Collin type B rotator cuff tear had significantly higher CAL Bonar scores than those with Collin type A or isolated supraspinatus tears (10.0 vs 6.8 and 3.4; P = .03 and P < .001, respectively). Patients with a degenerative acromial undersurface of Copeland-Levy stage 2 or 3 had CALs with significantly higher Bonar scores than those with an intact acromial undersurface (8.4 and 8.2 vs 3.5; P = .034 and P = .027, respectively). The CAL Bonar scores of patients with different stages of the 6-month postoperative Sugaya classification were comparable (6.5, 7.2, 8.0, and 7.8 for stages 1, 2, 3, and 4, respectively; P = .751). Conclusion: CAL degeneration was more severe in anterosuperior-type massive rotator cuff tears. Interestingly, even without acromioplasty, the severity of CAL degeneration did not affect the retear rate of the supraspinatus tendon.

15.
J Exp Orthop ; 10(1): 45, 2023 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-37067646

RESUMEN

PURPOSE: Suture anchors are commonly used to repair rotator cuff tendons in arthroscopy surgery, and several anchor materials have been created to maximize pull-out strength and minimize iatrogenic damage. We hypothesized that all-suture anchors have biomechanical properties equivalent to those of conventional anchors. Our purpose is to compare the biomechanical properties of different anchors used for rotator cuff repair. METHODS: The Embase, PubMed, Cochrane, and Scopus databases were searched for biomechanical studies on various suture anchors. The search keywords included rotator cuff tears and suture anchors, and two authors conducted study a selection, risk of bias assessment, and data extraction. The failure load, stiffness, and displacement were calculated using the mean differences with 95% confidence intervals (CIs). Failure modes were estimated using summary odds ratios with 95% CIs. The surface under the cumulative ranking curve was used for the relative ranking probabilities. A sensitivity analysis was performed by excluding studies using synthetic bones. RESULTS: The polyetheretherketone (PEEK) (p < 0.001) and all-suture anchors (p < 0.001) had higher failure loads than the biocomposite anchors, whereas no significant difference was observed in stiffness among the anchors. The all-suture (p = 0.006) and biocomposite anchors (p < 0.001) had displacements higher than the metal anchors. The relative ranking of the included anchors in failure loads and displacement changed in sensitivity analysis. The meta-analysis did not find significant differences, but the relative ranking probabilities suggested that all-suture anchor had a higher rate of anchor pull-out and a lower rate of eyelet or suture breakage. In contrast, the metal anchors were associated with a higher number of eyelet breakage episodes. CONCLUSIONS: All-suture anchors showed significantly higher failure loads than the biocomposite anchors and similar cyclic displacements to the biocomposite and PEEK anchors. There were no significant differences in stiffness between all-suture and conventional suture anchors. The relative ranking of biomechanical properties changed in sensitivity analysis, suggesting the potential effect of bone marrow density. LEVEL OF EVIDENCE: Level IV.

16.
Sci Rep ; 13(1): 6891, 2023 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-37105993

RESUMEN

The multitude of fixation options for radial neck fractures, such as pins, screws, biodegradable pins and screws, locking plates, and blade plates, has led to a lack of consensus on the optimal implant choice and associated biomechanical properties. This study aims to evaluate the biomechanical strength of various fixation constructs in axial, sagittal, and torsional loading directions. We included biomechanical studies comparing different interventions, such as cross/parallel screws, nonlocking plates with or without augmented screws, fixed angle devices (T or anatomic locking plates or blade plates), and cross pins. A systematic search of MEDLINE (Ovid), Embase, Scopus, and CINAHL EBSCO databases was conducted on September 26th, 2022. Data extraction was carried out by one author and verified by another. A network meta-analysis (NMA) was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Primary outcomes encompassed axial, bending, and torsional stiffness, while the secondary outcome was bending load to failure. Effect sizes were calculated for continuous outcomes, and relative treatment ranking was measured using the surface under the cumulative ranking curve (SUCRA). Our analysis encompassed eight studies, incorporating 172 specimens. The findings indicated that fixed angle constructs, specifically the anatomic locking plate, demonstrated superior axial stiffness (mean difference [MD]: 23.59 N/mm; 95% CI 8.12-39.06) in comparison to the cross screw. Additionally, the blade plate construct excelled in bending stiffness (MD: 32.37 N/mm; 95% CI - 47.37 to 112.11) relative to the cross screw construct, while the cross-screw construct proved to be the most robust in terms of bending load failure. The parallel screw construct performed optimally in torsional stiffness (MD: 139.39 Nm/degree; 95% CI 0.79-277.98) when compared to the cross screw construct. Lastly, the nonlocking plate, locking T plate, and cross-pin constructs were found to be inferior in most respects to alternative interventions. The NMA indicated that fixed angle devices (blade plate and anatomic locking plate) and screw fixations may exhibit enhanced biomechanical strength in axial and bending directions, whereas cross screws demonstrated reduced torsional stability in comparison to parallel screws. It is imperative for clinicians to consider the application of these findings in constraining forces across various directions during early range of motion exercises, taking into account the distinct biomechanical properties of the respective implants.


Asunto(s)
Fracturas Radiales de Cabeza y Cuello , Fracturas del Radio , Humanos , Fijación Interna de Fracturas , Metaanálisis en Red , Tornillos Óseos , Clavos Ortopédicos , Placas Óseas , Fracturas del Radio/cirugía , Fenómenos Biomecánicos
17.
Arthrosc Tech ; 12(2): e301-e305, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36879864

RESUMEN

Numerous techniques have been formulated for increasing the tendon-bone contact area and for providing a better healing environment for the tendon in cases of rotator cuff tear. An ideal rotator cuff repair maximizes the tendon-bone interface and provides the rotator cuff with sufficient biomechanical strength for it to withstand a high load. In this article, we propose a technique with the advantages of both the double-pulley and the rip-stop suture-bridge techniques, which increases the pressurized contact area along the medial row, achieves higher failure loads than non-rip-stop techniques, and reduces tendon cut-through.

18.
Arthrosc Tech ; 12(1): e33-e37, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36814989

RESUMEN

Concomitate supraspinatus and subscapularis tear is not rare, and the suture bridge technique is one of the most effective methods for rotator cuff repair. However, some limitations exist in the use of such a technique for simultaneous supraspinatus and subscapularis repair. We introduce the technique of a merged lateral row for suture bridge rotator cuff repair, in which the lateral suture of the supraspinatus and subscapularis is placed in the greater tuberosity. We believe that this technique can reduce both the duration and cost of surgery and decrease soft-tissue damage. It can also allow the "comma tissue," to be simultaneously repaired.

19.
J Shoulder Elbow Surg ; 32(4): 744-750, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36464206

RESUMEN

BACKGROUND: It remains unclear whether preoperative skin cleaning of the chin, neck, and chest with chlorhexidine soap can reduce suture contamination by Cutibacterium acnes in patients undergoing arthroscopic rotator cuff repair. METHODS: This study included patients who underwent primary arthroscopic rotator cuff repair. Exclusion criteria included age <18 years, previous shoulder surgery, history of shoulder infection, and allergy to chlorhexidine. Patients were randomized into 3 groups. Patients in the control group cleaned their skin with soap and water, as usual. Patients in the shoulder group cleaned their shoulders with chlorhexidine soap 3 days before surgery, whereas patients in the extended shoulder group additionally cleaned their chest, back, neck, and face with chlorhexidine soap. On the day of surgery, skin swab samples were obtained from the shoulder after surgical draping. After rotator cuff repair, sutures were cut from the anchor ends. Both traditional culture methods and polymerase chain reaction (PCR) were used. RESULTS: Ninety patients were enrolled (32 in the control group, 29 in the shoulder group, and 29 in the extended shoulder group) in the present study. The culture-positive rate from the posterior shoulder skin samples in the extended shoulder group (17.2%) was significantly lower than that in the control (40.6%) and shoulder (48.3%) groups (P = .036), whereas the culture-positive rates were not different among the 3 groups in other skin samples as well as the suture samples. The detection rates of C acnes in suture samples were 12.5%, 13.8%, and 17.2% in the control, shoulder, and extended shoulder groups, respectively (P = .603). CONCLUSION: Extensive skin cleaning of the shoulder region with chlorhexidine helps reduce the shoulder cutaneous bacterial load, but the detection of C acnes suture contamination in patients undergoing arthroscopic rotator cuff repair remained untouched regardless of the use of chlorhexidine soap in skin cleaning on the preoperative days.


Asunto(s)
Lesiones del Manguito de los Rotadores , Hombro , Humanos , Adolescente , Hombro/cirugía , Manguito de los Rotadores/cirugía , Clorhexidina/uso terapéutico , Lesiones del Manguito de los Rotadores/cirugía , Artroscopía/métodos , Carga Bacteriana , Jabones , Resultado del Tratamiento , Suturas , Técnicas de Sutura
20.
Am J Sports Med ; 50(13): 3625-3634, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36190171

RESUMEN

BACKGROUND: The scapular spine has been described as a relatively new bone graft alternative used in glenoid augmentation. The classic Latarjet procedure, which transfers the coracoid as a graft, is regarded as the gold standard. The comparison of these 2 techniques has not been fully reported. PURPOSE: To compare the anatomic and biomechanical properties of glenoid augmentation using scapular spine graft or coracoid graft. STUDY DESIGN: Controlled laboratory study. METHODS: The study used 20 fresh-frozen human cadaveric shoulders. A 25% anterior glenoid defect was created, and the specimens were divided randomly to receive glenoid augmentation by scapular spine or coracoid grafts. For both procedures, the grafts were secured to the glenoid defect with 2 screws. Morphometric data, including the glenoid articular area, amount of restoration, and graft dimensions, were obtained. A biomechanical test was conducted in a direct-loading scenario. The construct stiffness, cyclic displacement, and ultimate failure of each specimen were collected. RESULTS: No significant difference was found in glenoid articular restoration between the scapular spine group and the coracoid group (31% vs 33%, respectively; P = .311). Morphometric analysis indicated that coracoid grafts exhibited significantly greater thickness and height than scapular spine grafts. In biomechanical results, the scapular spine group exhibited significantly greater construct stiffness than the coracoid group (206.3 ± 58.8 vs 148.3 ± 76.0 N/mm, respectively; P = .023). The average failure load in the scapular spine group was not significantly higher than that in the coracoid group. No significant differences in cyclic displacement were found between the 2 techniques. CONCLUSION: In a simulated 25% anterior glenoid bony defect, a scapular spine graft was comparable with the classic Latarjet procedure in restoring the glenoid articular dimension and exhibited superior construct stiffness in a cadaveric model. CLINICAL RELEVANCE: The scapular spine may serve as an alternative graft choice in glenoid augmentation surgery considering the amount of articular restoration and initial fixation stability.


Asunto(s)
Inestabilidad de la Articulación , Articulación del Hombro , Humanos , Inestabilidad de la Articulación/cirugía , Articulación del Hombro/cirugía , Hombro , Cadáver , Escápula/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...