Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Neuroradiol ; 45(3): 164-168, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29132939

RESUMEN

BACKGROUND AND PURPOSE: Segmented brain tissue and myelin volumes can now be automatically calculated using dedicated software (SyMRI), which is based on quantification of R1 and R2 relaxation rates and proton density. The aim of this study was to determine the validity of SyMRI brain tissue and myelin volumetry using various in-plane resolutions. METHODS: We scanned 10 healthy subjects on a 1.5T MR scanner with in-plane resolutions of 0.8, 2.0 and 3.0mm. Two scans were performed for each resolution. The acquisition time was 7-min and 24-sec for 0.8mm, 3-min and 9-sec for 2.0mm and 1-min and 56-sec for 3.0mm resolutions. The volumes of white matter (WM), gray matter (GM), cerebrospinal fluid (CSF), non-WM/GM/CSF (NoN), brain parenchymal volume (BPV), intracranial volume (ICV) and myelin were compared between in-plane resolutions. Repeatability for each resolution was then analyzed. RESULTS: No significant differences in volumes measured were found between the different in-plane resolutions, except for NoN between 0.8mm and 2.0mm and between 2.0mm and 3.0mm. The repeatability error value for the WM, GM, CSF, NoN, BPV and myelin volumes relative to ICV was 0.97%, 1.01%, 0.65%, 0.86%, 1.06% and 0.25% in 0.8mm; 1.22%, 1.36%, 0.73%, 0.37%, 1.18% and 0.35% in 2.0mm and 1.18%, 1.02%, 0.96%, 0.45%, 1.36%, and 0.28% in 3.0mm resolutions. CONCLUSION: SyMRI brain tissue and myelin volumetry with low in-plane resolution and short acquisition times is robust and has a good repeatability so could be useful for follow-up studies.


Asunto(s)
Encéfalo/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/mortalidad , Vaina de Mielina , Adulto , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Tamaño de los Órganos , Programas Informáticos , Adulto Joven
2.
AJNR Am J Neuroradiol ; 38(8): 1610-1616, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28522664

RESUMEN

BACKGROUND AND PURPOSE: The Low-Profile Visualized Intraluminal Support Device comprises a small-cell nitinol structure and a single-wire braided stent that provides greater metal coverage than previously reported intracranial stents, as well as assumed strong susceptibility artifacts. This study aimed to assess the benefits of non-contrast-enhanced MRA by using a Silent Scan (Silent MRA) for intracranial anterior circulation aneurysms treated with Low-Profile Visualized Intraluminal Support Device stents. MATERIALS AND METHODS: Thirty-one aneurysms treated with Low-Profile Visualized Intraluminal Support Device stents were assessed by using Silent MRA, 3D TOF-MRA, and x-ray DSA. The quality of MRA visualization of the reconstructed artery was graded on a 4-point scale from 1 (not visible) to 4 (excellent). Aneurysm occlusion status was evaluated by using a 2-grade scale (total occlusion/remnant [neck or aneurysm]). Weighted κ statistics were used to evaluate interobserver and intermodality agreement. RESULTS: The mean scores ± SDs for Silent MRA and 3D TOF-MRA were 3.16 ± 0.79 and 1.48 ± 0.67 (P < .05), respectively, with substantial interobserver agreement (κ = 0.66). The aneurysm occlusion rates of the 2-grade scale (total occlusion/remnant [neck or aneurysm]) were 69%/31% for DSA, 65%/35% for Silent MRA, and 92%/8% for 3D TOF-MRA, respectively. The intermodality agreements were 0.88 and 0.30 for DSA/Silent MRA and DSA/3D TOF-MRA, respectively. CONCLUSIONS: Silent MRA seems to be useful for visualizing intracranial anterior circulation aneurysms treated with Low-Profile Visualized Intraluminal Support Device stents.


Asunto(s)
Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Angiografía por Resonancia Magnética/métodos , Stents , Adulto , Anciano , Angiografía de Substracción Digital , Arteria Cerebral Anterior/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Embolización Terapéutica , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Resultado del Tratamiento
3.
AJNR Am J Neuroradiol ; 38(2): 237-242, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27789453

RESUMEN

BACKGROUND AND PURPOSE: T1 and T2 values and proton density can now be quantified on the basis of a single MR acquisition. The myelin and edema in a voxel can also be estimated from these values. The purpose of this study was to evaluate a multiparametric quantitative MR imaging model that assesses myelin and edema for characterizing plaques, periplaque white matter, and normal-appearing white matter in patients with MS. MATERIALS AND METHODS: We examined 3T quantitative MR imaging data from 21 patients with MS. The myelin partial volume, excess parenchymal water partial volume, the inverse of T1 and transverse T2 relaxation times (R1, R2), and proton density were compared among plaques, periplaque white matter, and normal-appearing white matter. RESULTS: All metrics differed significantly across the 3 groups (P < .001). Those in plaques differed most from those in normal-appearing white matter. The percentage changes of the metrics in plaques and periplaque white matter relative to normal-appearing white matter were significantly more different from zero for myelin partial volume (mean, -61.59 ± 20.28% [plaque relative to normal-appearing white matter], and mean, -10.51 ± 11.41% [periplaque white matter relative to normal-appearing white matter]), and excess parenchymal water partial volume (13.82 × 103 ± 49.47 × 103% and 51.33 × 102 ± 155.31 × 102%) than for R1 (-35.23 ± 13.93% and -6.08 ± 8.66%), R2 (-21.06 ± 11.39% and -4.79 ± 6.79%), and proton density (23.37 ± 10.30% and 3.37 ± 4.24%). CONCLUSIONS: Multiparametric quantitative MR imaging captures white matter damage in MS. Myelin partial volume and excess parenchymal water partial volume are more sensitive to the MS disease process than R1, R2, and proton density.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen , Vaina de Mielina/patología , Neuroimagen/métodos , Sustancia Blanca/diagnóstico por imagen , Adulto , Edema/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
AJNR Am J Neuroradiol ; 38(2): 257-263, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27932506

RESUMEN

BACKGROUND AND PURPOSE: Synthetic MR imaging enables the creation of various contrast-weighted images including double inversion recovery and phase-sensitive inversion recovery from a single MR imaging quantification scan. Here, we assessed whether synthetic MR imaging is suitable for detecting MS plaques. MATERIALS AND METHODS: Quantitative and conventional MR imaging data on 12 patients with MS were retrospectively analyzed. Synthetic T2-weighted, FLAIR, double inversion recovery, and phase-sensitive inversion recovery images were produced after quantification of T1 and T2 values and proton density. Double inversion recovery images were optimized for each patient by adjusting the TI. The number of visible plaques was determined by a radiologist for a set of these 4 types of synthetic MR images and a set of conventional T1-weighted inversion recovery, T2-weighted, and FLAIR images. Conventional 3D double inversion recovery and other available images were used as the criterion standard. The total acquisition time of synthetic MR imaging was 7 minutes 12 seconds and that of conventional MR imaging was 6 minutes 29 seconds The lesion-to-WM contrast and lesion-to-WM contrast-to-noise ratio were calculated and compared between synthetic and conventional double inversion recovery images. RESULTS: The total plaques detected by synthetic and conventional MR images were 157 and 139, respectively (P = .014). The lesion-to-WM contrast and contrast-to-noise ratio on synthetic double inversion recovery images were superior to those on conventional double inversion recovery images (P = .001 and < 0.001, respectively). CONCLUSIONS: Synthetic MR imaging enabled detection of more MS plaques than conventional MR imaging in a comparable acquisition time. The contrast for MS plaques on synthetic double inversion recovery images was better than on conventional double inversion recovery images.


Asunto(s)
Enfermedades Desmielinizantes/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
5.
AJNR Am J Neuroradiol ; 38(3): 577-581, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28007767

RESUMEN

BACKGROUND AND PURPOSE: Y-configuration stent-assisted coil embolization is used for treating wide-neck aneurysms. Noninvasive alternatives to x-ray DSA for follow-up after Y-configuration stent-assisted coil embolization treatment are required. This study aimed to assess the usefulness of non-contrast-enhanced MRA by using a Silent Scan (silent MRA) for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms. MATERIALS AND METHODS: Seven patients treated with Y-configuration stent-assisted coil embolization for basilar tip aneurysms underwent silent MRA, 3D TOF-MRA, and DSA. Silent MRA and 3D TOF-MRA images were obtained during the same scan session on a 3T MR imaging system. Two neuroradiologists independently reviewed both types of MRA images and subjectively scored the flow in the stents on a scale of 1 (not visible) to 5 (nearly equal to DSA) by referring to the latest DSA image as a criterion standard. Furthermore, we evaluated the visualization of the neck remnant. RESULTS: In all patients, the 2 observers gave a higher score for the flow in the stents on silent MRA than on 3D TOF-MRA. The average score ± standard deviation was 4.07 ± 0.70 for silent MRA and 1.93 ± 0.80 (P < .05) for 3D TOF-MRA. Neck remnants were depicted by DSA in 5 patients. In silent MRA, neck remnants were depicted in 5 patients, and visualization was similar to DSA; however, in 3D TOF-MRA, neck remnants were depicted in only 1 patient. CONCLUSIONS: Silent MRA might be useful for follow-up after Y-configuration stent-assisted coil embolization.


Asunto(s)
Embolización Terapéutica/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Angiografía por Resonancia Magnética/métodos , Stents , Anciano , Angiografía de Substracción Digital/métodos , Angiografía Cerebral , Femenino , Estudios de Seguimiento , Humanos , Hallazgos Incidentales , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Arteria Cerebral Posterior/diagnóstico por imagen , Estudios Retrospectivos
6.
Am J Transplant ; 16(3): 968-78, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26639618

RESUMEN

Facial allotransplantation restores normal anatomy to severely disfigured faces. Although >30 such operations performed worldwide have yielded promising short-term results, data on long-term outcomes remain scarce. Three full-face transplant recipients were followed for 40 months. Severe changes in volume and composition of the facial allografts were noted. Data from computed tomography performed 6, 18 and 36 months after transplantation were processed to separate allograft from recipient tissues and further into bone, fat and nonfat soft tissues. Skin and muscle biopsies underwent diagnostic evaluation. All three facial allografts sustained significant volume loss (mean 19.55%) between 6 and 36 months after transplant. Bone and nonfat soft tissue volumes decreased significantly over time (17.22% between months 6 and 18 and 25.56% between months 6 and 36, respectively), whereas fat did not. Histological evaluations showed atrophy of muscle fibers. Volumetric and morphometric changes in facial allografts have not been reported previously. The transformation of facial allografts in this study resembled aging through volume loss but differed substantially from regular aging. These findings have implications for risk-benefit assessment, donor selection and measures counteracting muscle and bone atrophy. Superior long-term outcomes of facial allotransplantation will be crucial to advance toward future clinical routine.


Asunto(s)
Envejecimiento/patología , Traumatismos Faciales/cirugía , Trasplante Facial/efectos adversos , Complicaciones Posoperatorias , Adulto , Aloinjertos , Traumatismos Faciales/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Tomografía Computarizada por Rayos X , Receptores de Trasplantes
7.
Am J Transplant ; 14(3): 711-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24502329

RESUMEN

The vascular reorganization after facial transplantation has important implications on future surgical planning. The purpose of this study was to evaluate blood flow (BF) after full face transplantation using wide area-detector computed tomography (CT) techniques. Three subjects with severe craniofacial injury who underwent full face transplantation were included. All subjects underwent a single anastomosis bilaterally of the artery and vein, and the recipient tongue was preserved. Before and after surgery, dynamic volume CT studies were analyzed for vascular anatomy and blood perfusion. Postsurgical CT showed extensive vascular reorganization for external carotid artery (ECA) angiosome; collateral flows from vertebral, ascending pharyngeal or maxillary arteries supplied the branches from the recipient ECAs distal to the ligation. While allograft tissue was slightly less perfused when the facial artery was the only donor artery when compared to an ECA-ECA anastomosis (4.4 ± 0.4% vs. 5.7 ± 0.7%), allograft perfusion was higher than the recipient normal neck tissue. BF for the recipient tongue was maintained from contralateral/donor arteries when the lingual artery was sacrificed. Venous drainage was adequate for all subjects, even when the recipient internal jugular vein was anastomosed in end-to-end fashion on one side. In conclusion, dynamic CT identified adequate BF for facial allografts via extensive vascular reorganization.


Asunto(s)
Anastomosis Quirúrgica , Cara/irrigación sanguínea , Cara/cirugía , Trasplante Facial , Donantes de Tejidos , Adulto , Cara/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Radiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA