Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 11(1): 19994, 2021 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-34620962

RESUMEN

Improving geothermal systems through hydraulic stimulation to create highly permeable fractured rocks can induce seismicity. Therefore, the technique must be applied at a moderate intensity; this has led to concerns of insufficient permeability enhancement. Adding chemical stimulation can mitigate these issues, but traditional methods using strong mineral acids have challenges in terms of achieving mineral dissolution over long distances and highly variable fluid chemistry. Here, we demonstrate a novel chemical stimulation method for improving the permeability of rock fractures using a chelating agent that substantially enhances the dissolution rate of specific minerals to create voids that are sustained under crustal stress without the challenges associated with the traditional methods. Applying this agent to fractured granite samples under confining stress at 200 °C in conjunction with 20 wt% aqueous solutions of sodium salts of environmentally friendly chelating agents (N-(2-hydroxyethyl)ethylenediamine-N, N', N'-triacetic acid and N, N-bis(carboxymethyl)-L-glutamic acid) at pH 4 was assessed. A significant permeability enhancement of up to approximately sixfold was observed within 2 h, primarily due to the formation of voids based on the selective dissolution of biotite. These results demonstrate a new approach for chemical stimulation.

2.
Anal Sci ; 37(7): 991-995, 2021 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-33281132

RESUMEN

An amperometric biosensor for 1,2-dihydroxynaphthalene (DHN) and catechol (Cat) has been developed in order to monitor the biodegradaton of polycyclic aromatic hydrocarbons (PAHs). DHN is a common intermediary metabolite in naphthalene and phenanthrene degradation, while Cat is produced by further degradation. These compounds were detected by a biosensor modified with pyrroloquinoline quinone-dependent glucose dehydrogenase (PQQ-GDH). The biosensor was based on signal amplification by enzyme-catalyzed redox cycling and was able to detect DHN and Cat at very low concentrations down to 10-9 M. Since the anodic waves of DHN and Cat were well separated, simultaneous determinations of these compounds were possible. Although the current signal for DHN was reduced in repeated measurements due to the oxidative polymerization of DHN, it can be avoided when the concentration of DHN was sufficiently low (<1 µM).


Asunto(s)
Técnicas Biosensibles , Naftoles , Catecoles , Glucosa 1-Deshidrogenasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...