Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Health Technol Assess ; 16(2): v-xiii, 1-184, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22284744

RESUMEN

BACKGROUND: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. DESIGN: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. SETTING: Six UK maternity units. PARTICIPANTS: These were 20,055 asymptomatic newborns at ≥ 35 weeks' gestation, their mothers and health-care staff. INTERVENTIONS: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). MAIN OUTCOME MEASURES: Detection of major CHDs - defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. RESULTS: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. CONCLUSIONS: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions. FUNDING: The National Institute for Health Research Health Technology programme.


Asunto(s)
Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/epidemiología , Tamizaje Neonatal/métodos , Oximetría/normas , Adulto , Análisis de Varianza , Actitud del Personal de Salud , Estudios de Cohortes , Análisis Costo-Beneficio , Ecocardiografía/economía , Femenino , Humanos , Recién Nacido , Masculino , Madres/psicología , Tamizaje Neonatal/economía , Tamizaje Neonatal/psicología , Servicio de Ginecología y Obstetricia en Hospital , Oximetría/economía , Oximetría/psicología , Satisfacción del Paciente , Factores de Riesgo , Sensibilidad y Especificidad , Encuestas y Cuestionarios , Reino Unido/epidemiología , Adulto Joven
2.
J Laryngol Otol ; 120(3): 228-9, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16460577

RESUMEN

This report highlights innovative ways of overcoming difficulties in delivering effective continuous positive airway pressure in an extremely preterm baby with bilateral cleft lip and cleft palate.


Asunto(s)
Labio Leporino , Fisura del Paladar , Presión de las Vías Aéreas Positiva Contínua/métodos , Enfermedades del Prematuro , Presión de las Vías Aéreas Positiva Contínua/instrumentación , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro
3.
Arch Dis Child Fetal Neonatal Ed ; 88(5): F440, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12937056

RESUMEN

The placement of a central venous line in a low birthweight neonate led to a complication that highlights the need for continued vigilance after the position of the line is checked and thought satisfactory.


Asunto(s)
Ascitis/etiología , Cateterismo Venoso Central/efectos adversos , Nutrición Parenteral Total/efectos adversos , Líquido Ascítico , Humanos , Recién Nacido de Bajo Peso , Recién Nacido , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...