Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 19(7)2019 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-30934691

RESUMEN

In this research, we developed a miRNA sensor using an electrical double layer (EDL) gated field-effect transistor (FET)-based biosensor with enhanced sensitivity and stability. We conducted an in-depth investigation of the mechanisms that give rise to fluctuations in the electrical signal, affecting the stability and sensitivity of the miRNA sensor. Firstly, surface characteristics were studied by examining the metal electrodes deposited using different metal deposition techniques. The lower surface roughness of the gold electrode improved the electrical current stability. The temperature and viscosity of the sample solution were proven to affect the electrical stability, which was attributed to reducing the effect of Brownian motion. Therefore, by controlling the test conditions, such as temperature and sample viscosity, and the surface characteristics of the metal electrodes, we can enhance the stability of the sensor. Metal electrodes deposited via sputtering and e-beam evaporator yielded the lowest signal fluctuation. When ambient temperature was reduced to 3 °C, the sensor had better noise characteristics compared to room temperature testing. Higher viscosity of samples resulted in lower signal fluctuations. Lastly, surface functionalization was demonstrated to be a critical factor in enhancing the stability and sensitivity. MiRNA sensors with higher surface ratios of immobilized DNA probes performed with higher sensitivity and stability. This study reveals methods to improve the characteristics of EDL FET biosensors to facilitate practical implementation in clinical applications.


Asunto(s)
Técnicas Biosensibles/métodos , MicroARNs/análisis , Transistores Electrónicos , Aptámeros de Nucleótidos/química , Aptámeros de Nucleótidos/metabolismo , Técnicas Biosensibles/instrumentación , ADN de Cadena Simple/química , ADN de Cadena Simple/metabolismo , Conductividad Eléctrica , Electrodos , Oro/química , MicroARNs/metabolismo , Hibridación de Ácido Nucleico , Polímeros/química , Propiedades de Superficie , Temperatura
2.
Lab Chip ; 18(19): 2917-2925, 2018 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-30118128

RESUMEN

According to World Health Organization reports, cardiovascular diseases (CVDs) are amongst the major causes of death globally and are responsible for over 18 million deaths every year. Traditional detection methods for CVDs include cardiac computerized tomography scans, electrocardiography, and myocardial perfusion imaging scans. Although diagnosis of CVDs through such bio-imaging techniques is common, these methods are relatively costly and cannot detect CVDs in their earliest stages. In contrast, the levels of certain micro RNA (miRNA) biomarkers extracted from extracellular vesicles (EVs) in the bloodstream have been recognized as promising indicators for early CVD detection. However, detection and quantification of miRNA using existing methods are relatively labor-intensive and time-consuming. In this study, a new integrated microfluidic system equipped with highly sensitive field-effect transistors (FETs) was capable of performing EV extraction, EV lysis, target miRNA isolation and miRNA detection within 5 h. The limit of detection was within the physiological range (femtomolar) for two targeted miRNAs, miR-21 and miR-126, meaning that this integrated microfluidic system has the potential to be used as a tool for early detection of CVDs.


Asunto(s)
Enfermedades Cardiovasculares/metabolismo , Enfermedades Cardiovasculares/patología , Vesículas Extracelulares/metabolismo , Dispositivos Laboratorio en un Chip , MicroARNs/metabolismo , Biomarcadores/metabolismo , Línea Celular Tumoral , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...