Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev E ; 109(2-2): 025204, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38491565

RESUMEN

In this work we present the design of the first controlled fusion laboratory experiment to reach target gain G>1 N221204 (5 December 2022) [Phys. Rev. Lett. 132, 065102 (2024)10.1103/PhysRevLett.132.065102], performed at the National Ignition Facility, where the fusion energy produced (3.15 MJ) exceeded the amount of laser energy required to drive the target (2.05 MJ). Following the demonstration of ignition according to the Lawson criterion N210808, experiments were impacted by nonideal experimental fielding conditions, such as increased (known) target defects that seeded hydrodynamic instabilities or unintentional low-mode asymmetries from nonuniformities in the target or laser delivery, which led to reduced fusion yields less than 1 MJ. This Letter details design changes, including using an extended higher-energy laser pulse to drive a thicker high-density carbon (also known as diamond) capsule, that led to increased fusion energy output compared to N210808 as well as improved robustness for achieving high fusion energies (greater than 1 MJ) in the presence of significant low-mode asymmetries. For this design, the burnup fraction of the deuterium and tritium (DT) fuel was increased (approximately 4% fuel burnup and a target gain of approximately 1.5 compared to approximately 2% fuel burnup and target gain approximately 0.7 for N210808) as a result of increased total (DT plus capsule) areal density at maximum compression compared to N210808. Radiation-hydrodynamic simulations of this design predicted achieving target gain greater than 1 and also the magnitude of increase in fusion energy produced compared to N210808. The plasma conditions and hotspot power balance (fusion power produced vs input power and power losses) using these simulations are presented. Since the drafting of this manuscript, the results of this paper have been replicated and exceeded (N230729) in this design, together with a higher-quality diamond capsule, setting a new record of approximately 3.88MJ of fusion energy and fusion energy target gain of approximately 1.9.

2.
Phys Rev E ; 107(5-2): 055204, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37329027

RESUMEN

A wave near an isolated turning point is typically assumed to have an Airy function profile with respect to the separation distance. This description is incomplete, however, and is insufficient to describe the behavior of more realistic wave fields that are not simple plane waves. Asymptotic matching to a prescribed incoming wave field generically introduces a phase front curvature term that changes the characteristic wave behavior from the Airy function to that of the hyperbolic umbilic function. This function, which is one of the seven classic "elementary" functions from catastrophe theory along with the Airy function, can be understood intuitively as the solution for a linearly focused Gaussian beam propagating in a linearly varying density profile, as we show. The morphology of the caustic lines that govern the intensity maxima of the diffraction pattern as one alters the density length scale of the plasma, the focal length of the incident beam, and also the injection angle of the incident beam are presented in detail. This morphology includes a Goos-Hänchen shift and focal shift at oblique incidence that do not appear in a reduced ray-based description of the caustic. The enhancement of the intensity swelling factor for a focused wave compared to the typical Airy solution is highlighted, and the impact of a finite lens aperture is discussed. Collisional damping and finite beam waist are included in the model and appear as complex components to the arguments of the hyperbolic umbilic function. The observations presented here on the behavior of waves near turning points should aid the development of improved reduced wave models to be used, for example, in designing modern nuclear fusion experiments.


Asunto(s)
Cáusticos , Aire , Distribución Normal
3.
Rev Sci Instrum ; 94(2): 023507, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36859040

RESUMEN

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for "single-shot mode," the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ∼3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. We also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

4.
Phys Rev Lett ; 128(6): 065003, 2022 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-35213202

RESUMEN

A hologram fully encodes a three-dimensional light field by imprinting the interference between the field and a reference beam in a recording medium. Here we show that two collinear pump lasers with different foci overlapped in a gas jet produce a holographic plasma lens capable of focusing or collimating a probe laser at intensities several orders-of-magnitude higher than the limits of a nonionized optic. We outline the theory of these diffractive plasma lenses and present simulations for two plasma mechanisms that allow their construction: spatially varying ionization and ponderomotively driven ion-density fluctuations. Damage-resistant plasma optics are necessary for manipulating high-intensity light, and divergence control of high-intensity pulses-provided by holographic plasma lenses-will be a critical component of high-power plasma-based lasers.

5.
Alcohol Alcohol ; 31(3): 273-8, 1996 May.
Artículo en Inglés | MEDLINE | ID: mdl-8844033

RESUMEN

The efficacy of the diazepam loading dose method of treatment of delirium tremens was assessed in comparison with the traditional therapy. The experimental group and the control group comprised 51 and 45 patients respectively. The clinical institute withdrawal assessment for alcohol (CIWA-A) scale was applied to assess the intensity of the symptoms. Diazepam doses in the experimental group oscillated from 40 to 210 mg (mean 86.9 +/- 47.2 mg). The control group was receiving diazepam and other psychotropic drugs in divided doses. In the experimental group deliric symptoms were present from 2 to 24 h (mean 6.9 +/- 4.8 h), and in the control group from 2 to 123 h (mean 33.8 +/- 25.7 h). The results show a large efficacy of the loading dose method corresponding to substantial reduction of the psychosis duration (fivefold in comparison to the control group). The method proved to be safe, with no significant complications.


Asunto(s)
Delirio por Abstinencia Alcohólica/tratamiento farmacológico , Ansiolíticos/administración & dosificación , Diazepam/administración & dosificación , Adulto , Delirio por Abstinencia Alcohólica/sangre , Delirio por Abstinencia Alcohólica/diagnóstico , Ansiolíticos/efectos adversos , Ansiolíticos/farmacocinética , Diazepam/efectos adversos , Diazepam/farmacocinética , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Examen Neurológico/efectos de los fármacos , Nordazepam/farmacocinética , Psicosis Alcohólicas/sangre , Psicosis Alcohólicas/diagnóstico , Psicosis Alcohólicas/tratamiento farmacológico , Resultado del Tratamiento
6.
Psychiatr Pol ; 29(5): 675-86, 1995.
Artículo en Polaco | MEDLINE | ID: mdl-8577908

RESUMEN

In this efficacy the study of diazepam loading-dose treatment of delirium tremens was evaluated in comparison with traditional therapeutic methods. Experimental and control groups consisted of 42 and 40 patients respectively. The severity of the withdrawal symptoms was evaluated from clinical status, in the experimental group CIWA-A score was also employed. Study results suggest high efficacy of the loading-dose method, which was characterized by significant shortening of psychosis duration (five times shorter in experimental vs. control group). The method turned out to be safe, no complications were observed during and after the treatment.


Asunto(s)
Delirio por Abstinencia Alcohólica/tratamiento farmacológico , Ansiolíticos/administración & dosificación , Ansiolíticos/uso terapéutico , Diazepam/administración & dosificación , Diazepam/uso terapéutico , Adulto , Delirio por Abstinencia Alcohólica/etiología , Alcoholismo/complicaciones , Diazepam/sangre , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...