Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 194
Filtrar
2.
Indian J Thorac Cardiovasc Surg ; 40(2): 159-170, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38389777

RESUMEN

Introduction: In the context of double-valve surgery for elderly high-risk patients involving both the aortic and mitral valves, a clinically significant problem has been that no clear criteria or surgical strategies have been reported for the selection of mitral valve plasty (MVP) or mitral valve replacement (MVR) for mitral valve disease management during surgical aortic valve replacement (SAVR) to achieve better clinical outcomes. This study investigated valve durability and survival using our surgical strategy for mitral valve disease with concomitant SAVR in elderly patients. Methods: Eighty-six patients aged > 65 years (mean 75 years) who underwent a double-valve procedure for mitral valve surgery with concomitant SAVR from 2010 to 2022 were reviewed. Our surgical strategy for mitral valve disease with concomitant SAVR for the elderly patients was as follows: MVP was selected for patients in whom mitral valve disease was expected to be controlled with simple surgical procedures (n = 47), otherwise MVR was selected (n = 39). Results: The hospital mortality rate was 8% (n = 7). The mean follow-up was 4.9 (0-12.3) years. And the 10-year survival rate was 62%. The 10-year freedom from aortic valve reoperation rate was 95%. No mitral valve reintervention was performed during follow-up. Echocardiographic follow-up demonstrated freedom from at least moderate mitral regurgitation in 86% of cases at 10 years. Conclusion: In double-valve surgery for elderly high-risk patients, appropriate selection of the mitral valve procedure with concomitant SAVR provided better early and long-term survival and valve durability. This surgical strategy may be beneficial in elderly patients with combined aortic and mitral valve disease.

3.
J Endovasc Ther ; : 15266028231214206, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38050851

RESUMEN

PURPOSE: To evaluate the usefulness of a hybrid treatment strategy for acute type A aortic dissection (AAAD). METHODS: We retrospectively evaluated the outcomes of 39 partial arch replacements (PAR; 26 male/13 female, mean age=67.9 years) in 62 patients with AAAD operated at our hospital from January 2019 to January 2023. The technique included PAR with graft-designed landing length and translocated the brachiocephalic artery inflow site during the initial surgery to minimize the invasiveness of the surgery. Thereafter, second-stage thoracic endovascular aortic repair (second TEVAR) for distal aortic events in the chronic phase was performed. RESULTS: There was 1 case of 30-day mortality (2.6%) and 2 cases of postprocedural cerebral infarction (5.1%). The cumulative survival rates were 97.4%/1 year and 97.4%/3 years. The cumulative freedom from aorta-related second-stage procedure for the distal aortic event after initial PAR, which was performed in 13 patients (33.3%), was 63.9%/1 year and 59.7%/3 years. All patients requiring re-intervention after initial PAR underwent a second TEVAR with a 100% success rate and no postoperative complications. CONCLUSION: Initial PAR for AAAD in anticipation of the second TEVAR is a valuable strategy for enabling minimally invasive additional treatment of aorta-related re-intervention for distal aortic events in the chronic phase. CLINICAL IMPACT: This study provides detailed information on the hybrid aortic repair strategy of the initial open partial arch repair and second staged endovascular repair for the acute type A aortic dissection. Based on this study, distal aortic re-intervention after initial open partial arch repair was necessary only in about 30% of cases, and no cases of SCI were observed in the initial treatment or in the second-stage endovascular repair and no cases of distal SINE were observed after the second staged endovascular repair. Overall, the results suggest that limiting the initial open partial arch repair can achieve good perioperative and early outcomes of initial surgery, and that second staged endovascular re-intervention for distal aortic events can be performed reliably, safely, and with minimal invasiveness.

4.
J Endovasc Ther ; : 15266028231206993, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37882164

RESUMEN

PURPOSE: The effectiveness of thoracic endovascular aortic repair (TEVAR) for chronic aortic dissection (AD) with aneurysmal degeneration remains controversial. We retrospectively investigated clinical outcomes and assessed predictors of aortic shrinkage after TEVAR for chronic aneurysmal AD. MATERIALS AND METHODS: Between January 2010 and December 2021, 70 patients with double-barrel-type chronic AD were enrolled. Major intimal tears in thoracic aorta were covered by stent graft. Early and late clinical outcomes, and diameter change of downstream aorta during follow-up period were reviewed. Subsequently, factors associated with aortic shrinkage were assessed by logistic regression analysis. RESULTS: Mean age was 63 (interquartile range [IQR]: 54-68) years, 54 (80%) men, median duration from AD onset was 4 (IQR: 1-10) years, and maximum aortic diameter was 53 (IQR: 49-58) mm. Supra-aortic debranching procedure was required in 57 (81%) patients. Early aorta-related death occurred in 2 (3%) patients. Both stroke and spinal cord ischemia occurred in 1 (2%) patient. Five-year freedom rates from aorta-related death and reintervention were 96% and 51%, respectively. Sixty-four patients underwent follow-up computed tomography (84%) 1 year after TEVAR, with 33 (52%) achieving aortic shrinkage. In multivariable analysis, duration from AD onset (per year) (odds ratio [OR]: 0.82, 0.70-0.97; p=0.017) and maximum aortic-diameter ratio between aortic arch and descending aorta (per 0.1) (morphologic index; OR: 1.34, 1.04-1.74; p=0.023) were independent aortic shrinkage predictors. CONCLUSIONS: Thoracic endovascular aortic repair for chronic AD with aneurysmal degeneration achieved satisfactory survival outcomes, but with a considerable reintervention rate. Duration from AD onset and preoperative aortic morphology could affect post-TEVAR aortic shrinkage. Earlier intervention could lead to better aortic shrinkage. CLINICAL IMPACT: Thoracic endovascular aortic repair for chronic aortic dissection with aneurysmal degeneration showed low incidence of early and late aorta-related death. By contrast, aortic shrinkage rate was low with high incidence of reintervention to the residual downstream aorta. According to the assessment of preoperative variables, chronicity and aortic morphology could predict postoperative aortic shrinkage.

5.
JTCVS Open ; 15: 211-219, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37808015

RESUMEN

Objective: In patients with ischemic cardiomyopathy, coronary artery bypass grafting ensures better survival than medical therapy. However, the long-term clinical impact of complete revascularization remains unclear. This observational study aimed to evaluate the effects of complete revascularization on long-term survival and left ventricular functional recovery in patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting. Methods: We retrospectively reviewed outcomes of 498 patients with ischemic cardiomyopathy who underwent complete (n = 386) or incomplete (n = 112) myocardial revascularization between 1993 and 2015. The baseline characteristics were adjusted using inverse probability of treatment weighting to reduce the impact of treatment bias and potential confounding. The mean follow-up duration was 77.2 ± 42.8 months in survivors. Results: The overall 5-year survival rate (complete revascularization, 72.5% vs incomplete revascularization, 57.9%, P = .03) and freedom from all-cause death and/or readmission due to heart failure (54.5% vs 40.1%, P = .007) were significantly greater in patients with complete revascularization than those with incomplete revascularization. After adjustments using inverse probability of treatment weighting, the complete revascularization group demonstrated a lower risk of all-cause death (hazard ratio, 0.61; 95% confidence interval, 0.43-0.86; P = .005) and composite adverse events (hazard ratio, 0.59; 95% confidence interval, 0.44-0.79; P < .001) and a greater improvement in the left ventricular ejection fraction 1-year postoperatively (absolute change: 11.0 ± 11.9% vs 8.3 ± 11.4%, interaction effect P = .05) than the incomplete revascularization group. Conclusions: In patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting, complete revascularization was associated with better long-term outcomes and greater left ventricular functional recovery and should be encouraged whenever possible.

6.
J Clin Med ; 12(16)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37629368

RESUMEN

Background: Hybrid thoracic endovascular aortic repair (TEVAR) without median sternotomy is increasingly being performed in high-risk patients with aortic arch disease. The outcomes of hybrid TEVAR were reported to be worse with a more proximal landing zone. This study aims to clarify the effectiveness of zone 1-landing hybrid TEVAR by comparing the outcomes of zone 2-landing hybrid TEVAR. Methods: From April 2008 to October 2020, 213 patients (zone 1: zone 1-landing hybrid TEVAR, n = 82, 38.5%; zone 2: zone 2-landing hybrid TEVAR, n = 131, 61.5%) were enrolled (median age, 72 years; interquartile range [IQR], 65-78 years), with a median follow-up period of 6.0 years (IQR, 2.8-9.7 years). Results: The mean logistic EuroSCORE was 20.9 ± 14.8%: the logistic EuroSCORE of the zone 1 group (23.3 ± 16.1) was significantly higher than that of the zone 2 group (19.3 ± 12.4%, p = 0.045). The operative time and hospital stay of the zone 1 group were significantly longer than those of the zone 2 group. On the other hand, the in-hospital and late outcomes did not differ significantly between the two groups. There were no significant differences in cumulative survival (66.8% vs. 78.0% at 10 years, Log-rank p = 0.074), aorta-related death-free rates (97.6% vs. 99.2% at 10 years, Log-rank p = 0.312), and aortic event-free rates (81.4% vs. 87.9% at 10 years, Log-rank p = 0.257). Conclusions: Zone 1- and 2-landing hybrid TEVAR outcomes were satisfactory. Despite the high procedural difficulty and surgical risk, the outcomes of zone 1-landing hybrid TEVAR were equal to those of zone 2-landing hybrid TEVAR. If the surgical risk is high, zone 1-landing hybrid TEVAR should not be avoided.

7.
Eur J Vasc Endovasc Surg ; 66(4): 513-520, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37330200

RESUMEN

OBJECTIVE: This study aimed to investigate the impact of the number of patent lumbar arteries (LAs) on sac enlargement after endovascular aneurysm repair (EVAR). METHODS: This was a retrospective cohort single centre registry study. Between January 2006 and December 2019, 336 EVARs were reviewed using a commercially available device excluding type I or type III endoleaks during a follow up of ≥ 12 months. Patients were divided into four groups based on the pre-operative patency of the inferior mesenteric artery (IMA) and high (≥ 4) or low (≤ 3) number of patent LAs: Group 1, patent IMA and high number of patent LAs; Group 2, patent IMA and low number of patent LAs; Group 3, occluded IMA and a high number of patent LAs; Group 4, occluded IMA and low number of patent LAs. RESULTS: Groups 1, 2, 3, and 4 included 124, 104, 45, and 63 patients, respectively. The median follow up duration was 65.1 months. Significant differences in the incidence of overall type II endoleak (T2EL) at discharge between Group 1 and Group 2 (59.7% vs. 36.5%, p < .001) and between Group 3 and Group 4 (33.3% vs. 4.8%, p < .001) were observed. In patients with a pre-operatively patent IMA, the rate of freedom from aneurysm sac enlargement was significantly lower in Group 1 than in Group 2 (69.0% vs. 81.7% five years after EVAR, p < .001). In patients with a pre-operatively occluded IMA, the freedom rate from aneurysm sac enlargement was not significantly different between Groups 3 and Group 4 (95.0% vs. 100% five years after EVAR, p = .075). CONCLUSION: A high number of patent LAs seemed to have a significant role in sac enlargement with T2EL when the IMA was patent pre-operatively, whereas a high number of patent LAs seemed to have limited influence on sac enlargement when the IMA was occluded pre-operatively.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/epidemiología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Reparación Endovascular de Aneurismas , Estudios Retrospectivos , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Aorta Abdominal/cirugía , Resultado del Tratamiento , Embolización Terapéutica/efectos adversos , Factores de Riesgo
8.
J Endovasc Ther ; : 15266028231174407, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37222467

RESUMEN

PURPOSE: Hybrid thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is a minimally invasive procedure with improved results. This study aimed to clarify the effectiveness and expand the possibilities of zone 1 and 2 landing TEVAR for type B aortic dissection (TBAD) using our treatment strategy. METHODS: This retrospective, single-center, observational cohort study included 213 patients (TBAD, n=69; thoracic arch aneurysm [TAA], n=144; median age, 72 years; median follow-up period, 6 years) from May 2008 to February 2020. The following conditions were satisfied before performing zone 1 and 2 landing TEVAR: TBAD; proximal landing zone (LZ): diameter <37 mm, length >15 mm, and nondissection area, proximal stent-graft: size ≤40 mm and oversizing rate: 10% to 20%, and TAA; proximal LZ: diameter ≤42 mm and length >15 mm, proximal stent-graft: size ≤46 mm and oversizing rate: 10% to 20%. Of the 69 patients in the TBAD group, 34 (49.3%) had patent false lumen (PFL), and 35 (50.7%) had false lumen partial thrombosis (FLPT), including ulcer-like projections. Emergency procedures were performed in 33 (15.5%) patients. RESULTS: There were no significant differences in the in-hospital mortality (TBAD: 1.5% vs TAA: 0.7%, p=0.544) or the in-hospital aortic complications (TBAD: n=1 vs TAA: n=5, p=0.666). Retrograde type A dissection was not observed in the TBAD group. The aortic event-free rates at 10 years were 89.7% (95% confidence interval [CI]: 78.7%-95.3%) and 87.9% (95% CI: 80.3%-92.8%) in the TBAD and TAA groups, respectively (log-rank p=0.636). In the TBAD group, the early and late outcomes were not significantly different between the PFL and FLPT groups. CONCLUSION: Satisfactory early and long-term results were obtained with zone 1 and 2 landing TEVAR. The TBAD cases had the same good results as the TAA cases. Using our strategy, we especially might reduce complications and be an effective treatment for acute complicated TBAD. CLINICAL IMPACT: This study aimed to clarify the effectiveness and expand the possibilities of zones 1 and 2 landing TEVAR for type B aortic dissection (TBAD) using our treatment strategy. Satisfactory early and long-term results in the TBAD and thoracic arch aneurysm (TAA) groups were obtained with zones 1 and 2 landing TEVAR. The TBAD cases had the same good results as the TAA cases. Using our strategy, we especially might reduce complications and be an effective treatment for acute complicated TBAD.

9.
Cell Transplant ; 32: 9636897221148457, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36624995

RESUMEN

Although mesenchymal stem cell transplantation has been successful in the treatment of ischemic cardiomyopathy, the underlying mechanisms remain unclear. Herein, we investigated whether mitochondrial transfer could explain the success of cell therapy in ischemic cardiomyopathy. Mitochondrial transfer in co-cultures of human adipose-derived mesenchymal stem cells and rat cardiomyocytes maintained under hypoxic conditions was examined. Functional recovery was monitored in a rat model of myocardial infarction following human adipose-derived mesenchymal stem cell transplantation. We observed mitochondrial transfer in vitro, which required the formation of cell-to-cell contacts and synergistically enhanced energy metabolism. Rat cardiomyocytes exhibited mitochondrial transfer 3 days following human adipose-derived mesenchymal stem cell transplantation to the ischemic heart surface post-myocardial infarction. We detected donor mitochondrial DNA in the recipient myocardium concomitant with a significant improvement in cardiac function. Mitochondrial transfer is vital for successful cell transplantation therapies and improves treatment outcomes in ischemic cardiomyopathy.


Asunto(s)
Cardiomiopatías , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Infarto del Miocardio , Ratas , Humanos , Animales , Miocardio/metabolismo , Infarto del Miocardio/terapia , Infarto del Miocardio/genética , Miocitos Cardíacos/metabolismo , Cardiomiopatías/terapia , Trasplante de Células Madre
10.
Surg Case Rep ; 8(1): 221, 2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36517697

RESUMEN

BACKGROUND: Intrapulmonary penetration of the thoracic aorta is a rare, life-threatening complication of a chronic dissecting aortic aneurysm. It causes massive hemoptysis requiring prompt intervention to prevent fatal airway bleeding. A surgical approach that enables diverse surgical maneuvers and intraoperative organ protection is crucial. CASE PRESENTATION: A 62-year-old man, who underwent graft replacement of the ascending aorta for an acute type A aortic dissection 20 months before, developed massive hemoptysis and cardiac arrest. The hemoptysis was secondary to an aortopulmonary fistula from a rapidly expanding dissecting aortic aneurysm. However, a successful return of spontaneous circulation was achieved with cardiopulmonary resuscitation, including establishment of veno-arterial extracorporeal membrane oxygenation. The patient successfully underwent a total arch and descending thoracic aortic replacement. This was achieved by a median sternotomy combined with a left thoracotomy using a straight incision with a rib-cross (SIRC) approach. The patient was uneventfully discharged and remained well for the following 2 years. CONCLUSIONS: When performing a surgical graft replacement for an aortopulmonary fistula with a thoracic aortic aneurysm, the surgical approach chosen is critical. A surgical procedure using a median sternotomy combined with a left thoracotomy and a SIRC approach can be an effective therapeutic option.

11.
J Clin Med ; 11(23)2022 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-36498553

RESUMEN

Background: Zone 0 landing thoracic endovascular aortic repair (TEVAR) for the treatment of aortic arch diseases has become a topic of interest. This study aimed to verify whether branced TEVAR (bTEVAR) is an effective and a more minimally invasive treatment by comparing the outcomes of bTEVAR and hybrid TEVAR (hTEVAR) in landing zone 0. Methods: This retrospective, single-center, observational cohort study included 54 patients (bTEVAR, n = 25; hTEVAR, n = 29; median age, 78 years; median follow-up period, 5.4 years) from October 2012 to June 2018. The logistic Euro-SCORE was significantly higher in the bTEVAR group than in the hTEVAR group (38% vs. 21%, p < 0.001). Results: There was no significant difference the in-hospital mortality between the bTEVAR and hTEVAR groups (0% vs. 3.4%, p = 1.00). The operative time (220 vs. 279 min, p < 0.001) and length of hospital stay (12 vs. 17 days, p = 0.013) were significantly shorter in the bTEVAR group than in the hTEVAR group. The 7-year free rates of aorta-related deaths (bTEVAR [95.5%] vs. hTEVAR [86.9%], Log-rankp = 0.390) and aortic reintervention (bTEVAR [86.3%] vs. hTEVAR [86.9%], Log-rankp = 0.638) were not significantly different. Conclusions: The early and mid-term outcomes in both groups were satisfactory. bTEVAR might be superior to hTEVAR in that it is less invasive. Therefore, bTEVAR may be considered an effective and a more minimally invasive treatment for high-risk patients.

12.
JACC Asia ; 2(5): 635-644, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36518724

RESUMEN

Background: Although transcatheter aortic valve replacement (TAVR) has demonstrated favorable outcomes in randomized studies, there remains a sizable group of patients in whom TAVR may be futile. Characterizing the survival rate in a wide array of patients undergoing TAVR can help develop effective strategies for improving the allocation of medial resources. Objectives: The aim of this study was to develop a risk model to estimate 1-year mortality after TAVR from a representative nationwide registry in Japan. Methods: The J-TVT (Japan Transcatheter Valve Therapies) registry contains complete data, including 1-year outcomes, on patients undergoing TAVR in Japan. A total of 17,655 patients underwent TAVR between 2013 and 2018. They were randomly divided into 2 groups in a 7:3 ratio to form a derivation cohort of 12,316 patients and a validation cohort of 5,339 patients. A risk model was constructed for 1-year mortality in the derivation cohort, and its discrimination and calibration were assessed in the validation cohort. Results: The mean age of all registered patients was 84.4 years, and 68.8% were women. The mean body size area was 1.43 m2, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 7.3%. The estimated 1-year survival was 91.8%; 202 and 1,316 deaths were observed at 30 days and 1 year, respectively; The estimated C index for the developed model was 0.733 (95% CI: 0.709-0.757) in the validation cohort, with good calibration. Conclusions: A prediction model for 1-year survival following TAVR derived from a national clinical database performed well and should aid physicians managing TAVR patients.

13.
J Vasc Surg Cases Innov Tech ; 8(4): 620-622, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36248381

RESUMEN

Coral reef aorta (CRA) is characterized by heavily calcified obstructive lesions in the aorta. Thoracic endovascular aortic repair (TEVAR) is an established, less invasive procedure for aortic diseases; however, aortic occlusive diseases are commonly treated with conventional open surgery, and there are no reports of TEVAR in patients with a saccular aneurysm in CRA. We present a 72-year-old frail woman with a descending thoracic saccular aneurysm in CRA; therefore, we performed TEVAR. Although we had difficulty in advancing the stent graft system because it was caught in the severely calcified aorta, we finally succeeded in excluding the aneurysm.

14.
Circ J ; 86(11): 1764-1768, 2022 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-36184556

RESUMEN

BACKGROUND: The use of hybrid operating rooms (HOR) for transcatheter aortic valve implantation (TAVI) has increased, so radiation exposure during procedures that use X-ray fluoroscopy is a fundamental problem not only for patients but also for surgeons and interventional cardiologists, increasing the risk of cataracts among operators. We investigated the efficacy of leaded glasses and protective sheets for ocular radiation protection.Methods and Results: Between January 2020 and February 2021 we enrolled 54 TAVI procedures using the transfemoral approach. The subjects were divided into a curtain protection group (Group C, n=20), glass protection group (Group G, n=17), and sheet protection group (Group S, n=17). The cumulative dose (CD) of the operators showed a decreasing trend in Group S compared with the other two groups. The CD normalized by dose area product (CD/DAP) of the operators was significantly reduced in Group S compared with Group C. However, Group G showed no significant difference compared with Group C. Regarding the distribution of CD/DAP, Group S had a significantly lower distribution than that in groups C and G. CONCLUSIONS: Protective sheets provide more stable radiation protection than conventional curtains or leaded glasses.


Asunto(s)
Estenosis de la Válvula Aórtica , Exposición a la Radiación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Dosis de Radiación , Factores de Riesgo , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Fluoroscopía/efectos adversos , Válvula Aórtica/cirugía , Resultado del Tratamiento
15.
J Endovasc Ther ; : 15266028221121748, 2022 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-36120997

RESUMEN

PURPOSE: The impact of preoperative patent inferior mesenteric artery (IMA) on late outcomes following endovascular aneurysm repair (EVAR) remains unclear. This study aimed to investigate the specific influence of IMA patency on 7-year outcomes after EVAR. MATERIALS AND METHODS: In this retrospective cohort study, 556 EVARs performed for true abdominal aortic aneurysm cases between January 2006 and December 2019 at our institution were reviewed. Endovascular aneurysm repairs performed using a commercially available device with no type I or type III endoleak (EL) during follow-up and with follow-up ≥12 months were included. A total of 336 patients were enrolled in this study. The cohort was divided into the patent IMA group and the occluded IMA group according to preoperative IMA status. The late outcomes, including aneurysm sac enlargement, reintervention, and mortality rates, were compared between both groups using propensity-score-matched data. RESULTS: After propensity score matching, 86 patients were included in each group. The median follow-up period was 56 months (interquartile range: 32-94 months). The incidence of type II EL at discharge was 50% in the patent IMA group and 19% in the occluded IMA group (p<0.001). The type II EL from IMA and lumbar arteries was significantly higher in the patent IMA group than in the occluded IMA group (p<0.001 and p=0.002). The rate of freedom from aneurysm sac enlargement with type II EL was significantly higher in the occluded IMA group than in the patent IMA group (94% vs 69% at 7 years; p<0.001). The rate of freedom from reintervention was significantly higher in the occluded IMA group than in the patent IMA group (90% vs 74% at 7 years; p=0.007). Abdominal aortic aneurysm-related death and all-cause mortality did not significantly differ between groups (p=0.32 and p=0.34). CONCLUSIONS: Inferior mesenteric artery patency could affect late reintervention and aneurysm sac enlargement but did not have a significant impact on mortality. Preoperative assessment and embolization of IMA might be an important factor for improvement in late EVAR outcomes. CLINICAL IMPACT: The preoperative patency of the inferior mesenteric artery was significantly associated with a higher incidence of sac enlargement and reintervention with type II endoleak following endovascular aneurysm repair, even after adjustment for patient background. Preoperative assessment and embolization of inferior mesenteric artery might be an important factor for improvement in late EVAR outcomes.

16.
Ren Fail ; 44(1): 1083-1089, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35796036

RESUMEN

BACKGROUND: Patients undergoing maintenance hemodialysis (HD) with severe aortic stenosis are at a high risk for bioprosthetic valve dysfunction after transcatheter aortic valve implantation (TAVI). Currently, preoperative factors that predict the occurrence of valve dysfunction after TAVI on HD patients remain to be elucidated. The aim of this study is to analyze the association between preoperative clinical factors and valve stenosis after TAVI on HD patients. METHODS: Twenty-four of HD patients who underwent TAVI at our institution between April 2012 and January 2016 were analyzed. The mean aortic transvalvular pressure gradient (MPG) and effective orifice area index (EOAi) were assessed by serial echocardiography. Associations between preoperative clinical factors and time-series changes in MPG were examined using mixed-effects linear regression model for repeated measures. RESULTS: Three patients developed severe structural valve deterioration with calcific valve stenosis requiring reoperation. A multivariate linear mixed-effects model showed that lower serum magnesium (sMg) levels were associated with the increase of MPG after TAVI (beta-coefficient = 0.019, p = 0.03). No correlation was observed with serum calcium, phosphorus, or intact parathyroid hormone. Time-series changes of MPG and EOAi had significant difference between lower and higher sMg group. All 3 of the patients who underwent reoperation showed lower preoperative sMgs. CONCLUSION: Among bone-mineral metabolism markers, preoperative hypomagnesemia was associated with the increase of MPG after TAVI, suggesting that hypomagnesemia could predict post-TAVI valve dysfunction in HD patients. Further studies with larger sample sizes are warranted.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Constricción Patológica , Humanos , Magnesio , Periodo Posoperatorio , Diálisis Renal/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
J Cardiothorac Surg ; 17(1): 97, 2022 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-35505349

RESUMEN

OBJECTIVE: Mitral valve (MV) repair is a well-accepted surgical approach for infective endocarditis (IE). In our hospital, extensive MV reconstruction with fresh autologous pericardium (AP) and artificial chordae (AC) has been performed for patients with profoundly extensive and destructive IE in which valve reconstruction would be extremely challenging, especially in young patients to avoid mechanical valve replacement. Long-term outcome including the future performance of the newly created leaflet has not been established. METHODS: Five patients (54 (38-60) years of age; 3 men, 2 women) underwent this procedure from January 2011 to April 2022. In all patients, preoperative cardiac function was good (left ventricular ejection fraction, 69 (66-75)). After complete debridement of the infective valve tissue, the MV was reconstructed with large, fresh, trimmed AP and AC. RESULTS: The reconstructed leaflets were anterior in three patients and posterior in four, and AC were placed in four patients. All patients showed an uneventful postoperative course and were discharged to home 36 (28-42) days postoperatively after completion of intravenous antibiotic therapy. Pre-discharge echocardiography revealed no or trivial mitral regurgitation (MR) in all patients. The median follow-up period was 9.6 (6.0-10.4) years, and no patients developed recurrence of the IE. The latest echocardiography in four patients showed trivial/mild MR with good leaflet function. One patient developed recurrence of MR, 5 months postoperatively. CONCLUSIONS: The short- and long-term outcomes of this procedure might be acceptable. This procedure might be considered as an effective and valuable option, especially in young patients.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Insuficiencia de la Válvula Mitral , Preescolar , Endocarditis/cirugía , Endocarditis Bacteriana/cirugía , Femenino , Humanos , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Pericardio/trasplante , Volumen Sistólico , Función Ventricular Izquierda
19.
J Am Heart Assoc ; 11(6): e023848, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35243902

RESUMEN

Background The practice pattern and outcome of medical devices following their regulatory approval may differ by country. The aim of this study is to compare postapproval national clinical registry data on transcatheter aortic valve replacement between the United States and Japan on patient characteristics, periprocedural outcomes, and the variability of outcomes as a part of a partnership program (Harmonization-by-Doing) between the 2 countries. Methods and Results The patient-level data were extracted from the US Society of Thoracic Surgeons /American College of Cardiology Transcatheter Valve Therapy (STS/ACC TVT) and the J-TVT (Japanese Transcatheter Valvular Therapy) registry, respectively, to analyze transcatheter aortic valve replacement outcomes between 2013 and 2019. Data entry for these registries was mandated by the federal regulators, and the majority of variable definitions were harmonized to allow direct data comparison. A total of 244 722 transcatheter aortic valve replacements from 646 institutions in the United States and 26 673 transcatheter aortic valve replacements from 171 institutions in Japan were analyzed. Median volume per site was 65 (interquartile range, 45-97) in the United States and 28 (interquartile range, 19-41) in Japan. Overall, patients in J-TVT were older (United States: mean-age, 80.1±8.7 versus Japan: 84.4±5.2; P<0.001), were more frequently women (45.9% versus 68.1%; P<0.001), and had higher median Society of Thoracic Surgeons Predicted Risk of Mortality (5.27% versus 6.20%; P<0.001) than patients in the United States. Japan had lower unadjusted 30-day mortality (1.3% versus 3.2%; P<0.001) and composite outcomes of death, stroke, and bleeding (17.5 versus 22.5%; P<0.001) but had higher conversion to open surgery (0.94% versus 0.56%; P<0.001). Conclusions This collaborative analysis between the United States and Japan demonstrated the feasibility of international comparison using the national registries coded under mutual variable definitions. Both countries obtained excellent outcomes, although the Japanese had lower 30-day mortality and major morbidity. Harmonization-by-Doing is one of the key steps needed to build global-level learning to improve patient outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiología , Cirujanos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Femenino , Humanos , Japón/epidemiología , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
Ann Thorac Surg ; 114(1): 115-124, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34534528

RESUMEN

BACKGROUND: This study aimed to clarify the incidence and determinants of postoperative adverse events in patients with ischemic cardiomyopathy who achieved long-term durable mitral valve repair. METHODS: Between 1999 and 2015, 166 patients with chronic ischemic mitral regurgitation (MR) and a left ventricular ejection fraction ≤40% underwent restrictive mitral annuloplasty. During follow-up (65 ± 34 months), echocardiographic assessments were performed 809 times (mean, 4.9 ± 2.4 times), and 20 patients who had postoperative recurrent MR (moderate or severe) were excluded. Finally, 146 patients (aged 68 [63-75] years) whose MR was well controlled over time were included. RESULTS: A total of 61 deaths or 27 readmissions for heart failure were observed in 76 patients (52%). Among hospital survivors, age (adjusted hazard ratio, 1.05; P = .001) and estimated glomerular filtration rate (adjusted hazard ratio, 0.61; P = .001) were identified as independent predictors of long-term mortality or readmission for heart failure. The degree of postoperative left ventricular function recovery was comparable between patients with and without adverse events. However, the former group showed greater values for systolic pulmonary artery pressure, tricuspid regurgitation severity, inferior vena cava dimension, and plasma brain natriuretic peptide level throughout the follow-up period (group effect P < .05 for all). CONCLUSIONS: Approximately 50% of patients died or were hospitalized for heart failure even in the absence of recurrent MR during the 5-year follow-up, a finding indicating that durable mitral repair does not always lead to favorable clinical outcomes. The adverse events may have been related to volume overload secondary to impaired renal function and less favorable pulmonary hemodynamics.


Asunto(s)
Insuficiencia Cardíaca , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Insuficiencia Cardíaca/etiología , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...