Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Vet Rec ; 189(5): e510, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34028840

RESUMEN

BACKGROUND: Surgery of the bulla in the dog can be difficult and associated with suboptimal resolution of disease and risk of complications, particularly in treatment of cholesteatoma. We explored use of image guidance and endoscopic assistance in ventral bulla osteotomy (VBO), initially with cadaveric studies and subsequently on dogs with cholesteatoma. METHODS: For surgical approach we used cone beam CT with an optical image navigation system. For endoscopic surgery we used 4 mm and 2.7 mm diameter endoscopes and a camera viewing system, with micro-instruments for dissection. RESULTS: Image guidance allowed us to accurately identify and approach the bulla in cadavers (n = 2) and patients (n = 2). The endoscope enabled us to define detailed endoscopic anatomy in cadaveric canine heads (n = 15), and in patients (n = 5) it enabled reliable and safe removal of pathological tissue. CONCLUSION: Image and endoscopic assistance could be a significant advance to the reliability and safety of VBO. Our techniques may be applicable to other indications and species.


Asunto(s)
Vesícula , Enfermedades de los Perros , Animales , Vesícula/veterinaria , Cadáver , Perros , Endoscopios/veterinaria , Endoscopía/veterinaria , Osteotomía/veterinaria , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA