Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38385955

RESUMEN

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (⌀0.42 m) and large (⌀6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ∼50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism's vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 µrad s. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

2.
Rev Sci Instrum ; 91(12): 124503, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33380005

RESUMEN

We present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate <2 W. During cooldown, a grip-and-release mechanism centers the rotor to <0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 µrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.

3.
Phys Rev Lett ; 124(13): 131301, 2020 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-32302154

RESUMEN

Using only cosmic microwave background polarization data from the polarbear experiment, we measure B-mode polarization delensing on subdegree scales at more than 5σ significance. We achieve a 14% B-mode power variance reduction, the highest to date for internal delensing, and improve this result to 22% by applying for the first time an iterative maximum a posteriori delensing method. Our analysis demonstrates the capability of internal delensing as a means of improving constraints on inflationary models, paving the way for the optimal analysis of next-generation primordial B-mode experiments.

4.
Rev Sci Instrum ; 87(9): 094503, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27782567

RESUMEN

We present an evaluation of systematic effects associated with a continuously rotating, ambient-temperature half-wave plate (HWP) based on two seasons of data from the Atacama B-Mode Search (ABS) experiment located in the Atacama Desert of Chile. The ABS experiment is a microwave telescope sensitive at 145 GHz. Here we present our in-field evaluation of celestial (Cosmic Microwave Background (CMB) plus galactic foreground) temperature-to-polarization leakage. We decompose the leakage into scalar, dipole, and quadrupole leakage terms. We report a scalar leakage of ∼0.01%, consistent with model expectations and an order of magnitude smaller than other CMB experiments have been reported. No significant dipole or quadrupole terms are detected; we constrain each to be <0.07% (95% confidence), limited by statistical uncertainty in our measurement. Dipole and quadrupole leakage at this level lead to systematic error on r ≲ 0.01 before any mitigation due to scan cross-linking or boresight rotation. The measured scalar leakage and the theoretical level of dipole and quadrupole leakage produce systematic error of r < 0.001 for the ABS survey and focal-plane layout before any data correction such as so-called deprojection. This demonstrates that ABS achieves significant beam systematic error mitigation from its HWP and shows the promise of continuously rotating HWPs for future experiments.

5.
Rev Sci Instrum ; 85(2): 024501, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593374

RESUMEN

We evaluate the modulation of cosmic microwave background polarization using a rapidly rotating, half-wave plate (HWP) on the Atacama B-Mode Search. After demodulating the time-ordered-data (TOD), we find a significant reduction of atmospheric fluctuations. The demodulated TOD is stable on time scales of 500-1000 s, corresponding to frequencies of 1-2 mHz. This facilitates recovery of cosmological information at large angular scales, which are typically available only from balloon-borne or satellite experiments. This technique also achieves a sensitive measurement of celestial polarization without differencing the TOD of paired detectors sensitive to two orthogonal linear polarizations. This is the first demonstration of the ability to remove atmospheric contamination at these levels from a ground-based platform using a rapidly rotating HWP.

6.
Phys Rev Lett ; 98(22): 221602, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17677832

RESUMEN

We present a measurement of CP asymmetry using a time-dependent Dalitz plot analysis of B0-->pi+pi-pi0 decays based on a 414 fb(-1) data sample containing 449 x 10(6) BB pairs. The data was collected on the Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric energy e+ e- collider. Combining our analysis with information on charged B decay modes, we perform a full Dalitz and isospin analysis and obtain a constraint on the CKM angle phi2, 68 degrees < phi2 < 95 degrees as the 68.3% confidence interval for the phi2 solution consistent with the standard model (SM). A large SM-disfavored region also remains.

7.
Gifu Shika Gakkai Zasshi ; 16(2): 618-27, 1989 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-2489455

RESUMEN

A 19-year-old man was first seen with a chief complaint of mandibular protrusion and TMJ pain. His records showed a class III malocclusion with excessive mandibular body length and poor facial profile. Treatment was done with a multibracket orthodontie appliance combined with a surgical mandibular back using a Obwegeser method. In this report, we appraised the changing rate of MKG and EMG in pre-treatment, post-surgery, and during the retention phase.


Asunto(s)
Maloclusión de Angle Clase III/terapia , Adulto , Electromiografía , Humanos , Masculino , Maloclusión de Angle Clase III/cirugía , Mandíbula/cirugía , Ortodoncia Correctiva
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...