Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Breath Res ; 9(4): 047111, 2015 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-26669802

RESUMEN

State-of-the-art methods for non-invasive detection of the Helicobacter pylori (H. pylori) infection have been considered. A reported global tendency towards a non-decreasing prevalence of H. pylori worldwide could be co-influenced by the functional limitations of urea breath tests (UBTs), currently preferred for the non-invasive recognition of H. pylori in a clinical setting. Namely, the UBTs can demonstrate false-positive or false-negative results. Within this context, limitations of conventional clinically exploited H. pylori tests have been discussed to justify the existing need for the development of a new generation of breath tests for the detection of H. pylori and the differentiation of pathogenic and non-pathogenic strains of the bacterium. This paper presents the results of a pilot clinical study aimed at evaluating the development and diagnostic potential of a new method based on the detection of the non-urease products of H. pylori vital activity in exhaled gas. The characteristics of breath of adolescents with H. pylori-positive and H. pylori-negative functional dyspepsia, together with a consideration of the cytotoxin-associated gene A (CagA) status of H. pylori-positive subjects, have been determined for the first time using innovative point-contact nanosensor devices based on salts of the organic conductor tetracyanoquinodimethane (TCNQ). The clinical and diagnostic relevance of the response curves of the point-contact sensors was assessed. It was found that the recovery time of the point-contact sensors has a diagnostic value for differentiation of the H. pylori-associated peptic ulcer disease. The diagnostically significant elongation of the recovery time was even more pronounced in patients infected with CagA-positive H. pylori strains compared to the CagA-negative patients. Taking into account the operation of the point-contact sensors in the real-time mode, the obtained results are essential prerequisites for the development of a fast and portable breath test for non-invasive detection of cytotoxic CagA strains of H. pylori infection. The relaxation time of the point-contact nanosensors could be selected as a diagnostic criterion for non-invasive determination of H. pylori-associated destructive lesions of the gastroduodenal area in adolescents, using the point-contact spectroscopic concept of breath analysis. This can subsequently be implemented into a 'test-and-treat' approach for the management of uninvestigated dyspepsia in populations with a high prevalence of H. pylori (according to the Maastricht III and IV Consensus recommendations).


Asunto(s)
Pruebas Respiratorias/métodos , Helicobacter pylori/aislamiento & purificación , Adolescente , Antígenos Bacterianos/metabolismo , Proteínas Bacterianas/metabolismo , Dispepsia/complicaciones , Dispepsia/epidemiología , Ensayo de Inmunoadsorción Enzimática , Infecciones por Helicobacter/diagnóstico , Infecciones por Helicobacter/epidemiología , Infecciones por Helicobacter/microbiología , Humanos , Nitrilos/metabolismo , Úlcera Péptica/complicaciones , Urea/análisis
2.
Clin Chem Lab Med ; 46(7): 1011-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18605961

RESUMEN

BACKGROUND: This study was performed to clarify variations in breath isoprene concentrations with age, gender, body mass index (BMI) and total serum cholesterol. Our cohort consisted of 205 adult volunteers of different smoking background without health complaints. Total cholesterol in blood serum was measured in 79 of these volunteers. METHODS: Mixed expiratory exhaled breath was sampled using Tedlar bags. Concentrations of isoprene were then determined using proton transfer reaction-mass spectrometry. RESULTS: Isoprene concentrations ranged from 5.8 to 274.9 ppb, with an overall geometric mean (GM) of 99.3 ppb. There was no statistically significant difference in mean isoprene in breath between males and females (GM 105.4 and 95.5 ppb, respectively). Ageing led to a decrease in concentration in men, with an estimated slope of the regression line for log-transformed isoprene concentrations of -0.0049, but did not influence isoprene levels in women. We did not observe any significant correlation between isoprene breath content and cholesterol level in blood, even after adjusting for the possible influence of age. Similarly, no correlation was found between isoprene levels and BMI. CONCLUSIONS: Isoprene concentrations in exhaled breath showed gender-specific correlations with respect to age. Further investigations are necessary to clarify the relation between isoprene concentrations in exhaled breath and cholesterol levels and synthesis rates in blood.


Asunto(s)
Butadienos/análisis , Colesterol/sangre , Hemiterpenos/análisis , Pentanos/análisis , Envejecimiento , Índice de Masa Corporal , Pruebas Respiratorias , Calibración , Espiración , Femenino , Humanos , Masculino , Espectrometría de Masas , Caracteres Sexuales
3.
J Breath Res ; 2(2): 026002, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21383443

RESUMEN

A pilot study has been carried out to define typical characteristics of the trace gas compounds in exhaled breath of non-smokers and smokers to assist interpretation of breath analysis data from patients who smoke with respiratory diseases and lung cancer. Exhaled breath was analyzed using proton transfer reaction-mass spectrometry (PTR-MS) for 370 volunteers (81 smokers, 210 non-smokers, 79 ex-smokers). Volatile organic compounds corresponding to product ions at seven mass-to-charge ratios (m/z 28, 42, 69, 79, 93, 97, 123) in the PTR-MS spectra differentiated between smokers and non-smokers. The Youden index (= maximum of sensitivity + specificity - 1, YI) as a measure for differentiation between smokers and non-smokers was YI = 0.43 for ions at the m/z values 28 (tentatively identified as HCN), YI = 0.75 for m/z = 42 (tentatively identified as acetonitrile) and YI = 0.53 for m/z = 79 (tentatively identified as benzene). No statistically significant difference between smokers and non-smokers was observed for the product ions at m/z = 31 and 33 (compounds tentatively identified as formaldehyde and methanol). When interpreting the exhaled breath of lung cancer or COPD patients, who often smoke, compounds appearing at the above-mentioned seven mass-to-charge ratios should be considered with appropriate care to avoid misdiagnosis. Validation studies in larger numbers of patients with more precise delineation of their smoking behavior and using additional analytical techniques such as GC/MS and SIFT-MS should be carried out.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA