Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Chem ; 70(3): 528-537, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38431279

RESUMEN

BACKGROUND: Lipid profiling is central for coronary artery disease (CAD) risk assessment. Nonadherence or unreported use of lipid-lowering drugs, particularly statins, can significantly complicate the association between lipid profile measures and CAD clinical outcomes. By combining medication history evaluation with statin analysis in plasma, we determined the effects of inaccurately reported statin use on lipid profile measures and their association with CAD risk. METHODS: We compared medication history of statin use with statin concentration measurements, by liquid chromatography-tandem mass spectrometry, in 690 participants undergoing coronary angiography (63 ± 11 years of age). Nominal logistic regression was employed to model CAD diagnosis with statin measurements, phenotypic, and lipid profile characteristics. RESULTS: Medication history of statin use was confirmed by statin assay for 81% of the patients. Surprisingly, statins were detected in 46% of patients without statin use records. Nonreported statin use was disproportionately higher among older participants. Stratifying samples by statin history resulted in underestimated LDL-lipid measures. Apolipoprotein B concentrations had a significant inverse CAD association, which became nonsignificant upon re-stratification using the statin assay data. CONCLUSIONS: Our study uncovered prominent discrepancies between medication records and actual statin use measured by mass spectrometry. We showed that inaccurate statin use assessments may lead to overestimation and underestimation of LDL levels in statin user and nonuser categories, exaggerating the reverse epidemiology association between LDL levels and CAD diagnosis. Combining medication history and quantitative statin assay data can significantly improve the design, analysis, and interpretation of clinical and epidemiological studies.


Asunto(s)
Enfermedad de la Arteria Coronaria , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Lípidos , Medición de Riesgo , Factores de Riesgo , Persona de Mediana Edad , Anciano
2.
Int J Mol Sci ; 24(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37175638

RESUMEN

Designing studies for lipid-metabolism-related biomarker discovery is challenging because of the high prevalence of various statin and fibrate usage for lipid-lowering therapies. When the statin and fibrate use is determined based on self-reports, patient adherence to the prescribed statin dose regimen remains unknown. A potentially more accurate way to verify a patient's medication adherence is by direct analytical measurements. Current analytical methods are prohibitive because of the limited panel of drugs per test and large sample volume requirement that is not available from archived samples. A 4-min-long method was developed for the detection of seven statins and three fibrates using 10 µL of plasma analyzed via reverse-phase liquid chromatography and tandem mass spectrometry. The method was applied to the analysis of 941 archived plasma samples collected from patients before cardiac catheterization. When statin use was self-reported, statins were detected in 78.6% of the samples. In the case of self-reported atorvastatin use, the agreement with detection was 90.2%. However, when no statin use was reported, 42.4% of the samples had detectable levels of statins, with a similar range of concentrations as the samples from the self-reported statin users. The method is highly applicable in population studies designed for biomarker discovery or diet and lifestyle intervention studies, where the accuracy of statin or fibrate use may strongly affect the statistical evaluation of the biomarker data.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Ácidos Fíbricos/uso terapéutico , Cromatografía Liquida , Espectrometría de Masas en Tándem , Atorvastatina/uso terapéutico , Biomarcadores
3.
N Engl J Med ; 382(8): 697-705, 2020 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-31860793

RESUMEN

BACKGROUND: The causative agents for the current national outbreak of electronic-cigarette, or vaping, product use-associated lung injury (EVALI) have not been established. Detection of toxicants in bronchoalveolar-lavage (BAL) fluid from patients with EVALI can provide direct information on exposure within the lung. METHODS: BAL fluids were collected from 51 patients with EVALI in 16 states and from 99 healthy participants who were part of an ongoing study of smoking involving nonsmokers, exclusive users of e-cigarettes or vaping products, and exclusive cigarette smokers that was initiated in 2015. Using the BAL fluid, we performed isotope dilution mass spectrometry to measure several priority toxicants: vitamin E acetate, plant oils, medium-chain triglyceride oil, coconut oil, petroleum distillates, and diluent terpenes. RESULTS: State and local health departments assigned EVALI case status as confirmed for 25 patients and as probable for 26 patients. Vitamin E acetate was identified in BAL fluid obtained from 48 of 51 case patients (94%) in 16 states but not in such fluid obtained from the healthy comparator group. No other priority toxicants were found in BAL fluid from the case patients or the comparator group, except for coconut oil and limonene, which were found in 1 patient each. Among the case patients for whom laboratory or epidemiologic data were available, 47 of 50 (94%) had detectable tetrahydrocannabinol (THC) or its metabolites in BAL fluid or had reported vaping THC products in the 90 days before the onset of illness. Nicotine or its metabolites were detected in 30 of 47 of the case patients (64%). CONCLUSIONS: Vitamin E acetate was associated with EVALI in a convenience sample of 51 patients in 16 states across the United States. (Funded by the National Cancer Institute and others.).


Asunto(s)
Lesión Pulmonar Aguda/patología , Líquido del Lavado Bronquioalveolar/química , Sistemas Electrónicos de Liberación de Nicotina , Vapeo/efectos adversos , Vitamina E/análisis , Lesión Pulmonar Aguda/etiología , Adolescente , Adulto , Anciano , Fumar Cigarrillos , Aceite de Coco/análisis , Femenino , Humanos , Limoneno/análisis , Masculino , Persona de Mediana Edad , Estados Unidos , Adulto Joven
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1118-1119: 137-147, 2019 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-31035135

RESUMEN

Progress toward better diagnosis and treatment of lipid metabolism-related diseases requires high throughput approaches for multiplexed quantitative analysis of structurally diverse lipids, including phospholipids (PLs). This work demonstrates a simplified "one-pot" phospholipid extraction protocol, as an alternative to conventional liquid-liquid extraction. Performed in a 96-well format, the extraction was coupled with high throughput UPLC and multiplexed tandem mass spectrometry (MS/MS) detection, allowing non-targeted quantification of phosphatidylcholines (PC), sphingomyelins (SM), lysophosphatidylcholines (LPC), phosphatidylethanolamines (PE), and phosphatidylinositols (PI). Using 50 µL aliquots of serum samples from 110 individuals, lipoproteins were fractionated by size, and analyzed for phospholipids and non-polar lipids including free cholesterol (FC), cholesteryl esters (CEs) and triglycerides (TGs). Analysis of serum samples with wide range of Total-TG levels showed significant differences in PL composition. The correlations of molar ratios in lipoprotein size fractions, SM/PL with FC/PL, PE/PL with TG/CE, and PE/PL with PI/PL, demonstrate the applicability of the method for quantitative composition analysis of high, low and very-low density lipoproteins (HDL, LDL and VLDL), and characterization of lipid metabolism related disease states.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Dislipidemias/sangre , Dislipidemias/diagnóstico , Fosfolípidos/sangre , Espectrometría de Masas en Tándem/métodos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Fosfolípidos/aislamiento & purificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...