Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Ann Nucl Med ; 36(7): 623-633, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35534690

RESUMEN

AIM: In the CheckRad-CD8 trial patients with locally advanced head and neck squamous cell cancer are treated with a single cycle of induction chemo-immunotherapy (ICIT). Patients with pathological complete response (pCR) in the re-biopsy enter radioimmunotherapy. Our goal was to study the value of F-18-FDG PET/CT in the prediction of pCR after induction therapy. METHODS: Patients treated within the CheckRad-CD8 trial that additionally received FDG- PET/CT imaging at the following two time points were included: 3-14 days before (pre-ICIT) and 21-28 days after (post-ICIT) receiving ICIT. Tracer uptake in primary tumors (PT) and suspicious cervical lymph nodes (LN +) was measured using different quantitative parameters on EANM Research Ltd (EARL) accredited PET reconstructions. In addition, mean FDG uptake levels in lymphatic and hematopoietic organs were examined. Percent decrease (Δ) in FDG uptake was calculated for all parameters. Biopsy of the PT post-ICIT acquired after FDG-PET/CT served as reference. The cohort was divided in patients with pCR and residual tumor (ReTu). RESULTS: Thirty-one patients were included. In ROC analysis, ΔSUVmax PT performed best (AUC = 0.89) in predicting pCR (n = 17), with a decline of at least 60% (sensitivity, 0.77; specificity, 0.93). Residual SUVmax PT post-ICIT performed best in predicting ReTu (n = 14), at a cutpoint of 6.0 (AUC = 0.91; sensitivity, 0.86; specificity, 0.88). Combining two quantitative parameters (ΔSUVmax ≥ 50% and SUVmax PT post-ICIT ≤ 6.0) conferred a sensitivity of 0.81 and a specificity of 0.93 for determining pCR. Background activity in lymphatic organs or uptake in suspected cervical lymph node metastases lacked significant predictive value. CONCLUSION: FDG-PET/CT can identify patients with pCR after ICIT via residual FDG uptake levels in primary tumors and the related changes compared to baseline. FDG-uptake in LN + had no predictive value. TRIAL REGISTRY: ClinicalTrials.gov identifier: NCT03426657.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello , Linfocitos T CD8-positivos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/terapia , Humanos , Inmunoterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos
2.
Eur J Nucl Med Mol Imaging ; 49(2): 681-708, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34671820

RESUMEN

PURPOSE: Radiosynoviorthesis (RSO) using the intraarticular application of beta-particle emitting radiocolloids has for decades been used for the local treatment of inflammatory joint diseases. The injected radiopharmaceuticals are phagocytized by the superficial macrophages of the synovial membrane, resulting in sclerosis and fibrosis of the formerly inflamed tissue, finally leading to reduced joint effusion and alleviation of joint pain. METHODS: The European Association of Nuclear Medicine (EANM) has written and approved these guidelines in tight collaboration with an international team of clinical experts, including rheumatologists. Besides clinical and procedural aspects, different national legislative issues, dosimetric considerations, possible complications, and side effects are addressed. CONCLUSION: These guidelines will assist nuclear medicine physicians in performing radiosynoviorthesis. Since there are differences regarding the radiopharmaceuticals approved for RSO and the official indications between several European countries, this guideline can only give a framework that must be adopted individually.


Asunto(s)
Medicina Nuclear , Europa (Continente) , Humanos , Cintigrafía , Radiofármacos/efectos adversos
3.
Ann Nucl Med ; 34(4): 244-253, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32114682

RESUMEN

BACKGROUND: Patients with advanced neuroendocrine tumors (NETs) of the midgut are suitable candidates for 177Lu-DOTATOC therapy. Integrated SPECT/CT systems have the potential to help improve the accuracy of patient-specific tumor dosimetry. Dose estimations to target organs are generally performed using the Medical Internal Radiation Dose scheme. We present a novel Monte Carlo-based voxel-wise dosimetry approach to determine organ- and tumor-specific total tumor doses (TTD). METHODS: A cohort of 14 patients with histologically confirmed metastasized NETs of the midgut (11 men, 3 women, 62.3 ± 11.0 years of age) underwent a total of 39 cycles of 177Lu-DOTATOC therapy (mean 2.8 cycles, SD ± 1 cycle). After the first cycle of therapy, regions of interest were defined manually on the SPECT/CT images for the kidneys, the spleen, and all 198 tracer-positive tumor lesions in the field of view. Four SPECT images, taken at 4 h, 24 h, 48 h and 72 h after injection of the radiopharmaceutical, were used to determine their effective half-lives in the structures of interest. The absorbed doses were calculated by a three-dimensional dosimetry method based on Monte Carlo simulations. TTD was calculated as the sum of all products of single tumor doses with single tumor volumes divided by the sum of all tumor volumes. RESULTS: The average dose values per cycle were 3.41 ± 1.28 Gy (1.91-6.22 Gy) for the kidneys, 4.40 ± 2.90 Gy (1.14-11.22 Gy) for the spleen, and 9.70 ± 8.96 Gy (1.47-39.49 Gy) for all 177Lu-DOTATOC-positive tumor lesions. Low- and intermediate-grade tumors (G 1-2) absorbed a higher TTD compared to high-grade tumors (G 3) (signed-rank test, p = < 0.05). The pre-therapeutic chromogranin A (CgA) value and the TTD correlated significantly (Pearson correlation: = 0.67, p = 0.01). Higher TTD resulted in a significant decrease of CgA after therapy. CONCLUSION: These results suggest that Monte Carlo-based voxel-wise dosimetry is a very promising tool for predicting the absorbed TTD based on histological and clinical parameters.


Asunto(s)
Antineoplásicos/farmacocinética , Lutecio/farmacocinética , Tumores Neuroendocrinos/radioterapia , Octreótido/análogos & derivados , Compuestos Organometálicos/farmacología , Radioisótopos/farmacocinética , Radiofármacos/farmacocinética , Anciano , Antineoplásicos/administración & dosificación , Cromogranina A/efectos de la radiación , Femenino , Humanos , Lutecio/administración & dosificación , Masculino , Persona de Mediana Edad , Método de Montecarlo , Octreótido/administración & dosificación , Octreótido/química , Octreótido/farmacocinética , Compuestos Organometálicos/administración & dosificación , Compuestos Organometálicos/farmacocinética , Radioisótopos/administración & dosificación , Radiometría , Radiofármacos/administración & dosificación , Dosificación Radioterapéutica , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Resultado del Tratamiento
4.
Phys Med Biol ; 65(3): 035007, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-31881547

RESUMEN

Currently methods for predicting absorbed dose after administering a radiopharmaceutical are rather crude in daily clinical practice. Most importantly, individual tissue density distributions as well as local variations of the concentration of the radiopharmaceutical are commonly neglected. The current study proposes machine learning techniques like Green's function-based empirical mode decomposition and deep learning methods on U-net architectures in conjunction with soft tissue kernel Monte Carlo (MC) simulations to overcome current limitations in precision and reliability of dose estimations for clinical dosimetric applications. We present a hybrid method (DNN-EMD) based on deep neural networks (DNN) in combination with empirical mode decomposition (EMD) techniques. The algorithm receives x-ray computed tomography (CT) tissue density maps and dose maps, estimated according to the MIRD protocol, i.e. employing whole organ S-values and related time-integrated activities (TIAs), and from measured SPECT distributions of 177Lu radionuclei, and learns to predict individual absorbed dose distributions. In a second step, density maps are replaced by their intrinsic modes as deduced from an EMD analysis. The system is trained using individual full MC simulation results as reference. Data from a patient cohort of 26 subjects are reported in this study. The proposed methods were validated employing a leave-one-out cross-validation technique. Deviations of estimated dose from corresponding MC results corroborate a superior performance of the newly proposed hybrid DNN-EMD method compared to its related MIRD DVK dose calculation. Not only are the mean deviations much smaller with the new method, but also the related variances are much reduced. If intrinsic modes of the tissue density maps are input to the algorithm, variances become even further reduced though the mean deviations are less affected. The newly proposed hybrid DNN-EMD method for individualized radiation dose prediction outperforms the MIRD DVK dose calculation method. It is fast enough to be of use in daily clinical practice.


Asunto(s)
Algoritmos , Aprendizaje Profundo , Lutecio/farmacocinética , Lutecio/uso terapéutico , Método de Montecarlo , Neoplasias/radioterapia , Órganos en Riesgo/efectos de la radiación , Radioisótopos/farmacocinética , Radioisótopos/uso terapéutico , Glutamato Carboxipeptidasa II/metabolismo , Humanos , Neoplasias/metabolismo , Redes Neurales de la Computación , Dosis de Radiación , Radiofármacos/uso terapéutico , Reproducibilidad de los Resultados , Distribución Tisular , Tomografía Computarizada por Rayos X/métodos
5.
Phys Med Biol ; 64(24): 245011, 2019 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-31766045

RESUMEN

In [Formula: see text] radionuclide therapies, dosimetry is used for determining patient-individual dose burden. Standard approaches provide whole organ doses only. For assessing dose heterogeneity inside organs, voxel-wise dosimetry based on 3D SPECT/CT imaging could be applied. Often, this is achieved by convolving voxel-wise time-activity-curves with appropriate dose-voxel-kernels (DVK). The DVKs are meant to model dose deposition, and can be more accurate if modelled for the specific tissue type under consideration. In literature, DVKs are often not adapted to these inhomogeneities, or simple approximation schemes are applied. For 26 patients, which had previously undergone a [Formula: see text] -PSMA or -DOTATOC therapy, decay maps, mass-density maps as well as tissue-type maps were derived from SPECT/CT acquisitions. These were used for a voxel-based dosimetry based on convolution with DVKs (each of size [Formula: see text]) obtained by four different DVK methods proposed in literature. The simplest only considers a spatially constant soft-tissue DVK (herein named 'constant'), while others either take into account only the local density of the center voxel of the DVK (herein named 'center-voxel') or scale each voxel linearly according to the proper mass density deduced from the CT image (herein named 'density') or considered both the local mass density as well as the direct path between the center voxel and any voxel in its surrounding (herein named 'percentage'). Deviations between resulting dose values and those from full Monte-Carlo simulations (MC simulations) were compared for selected organs and tissue-types. For each DVK method, inter-patient variability was considerable showing both under- and over-estimation of energy dose compared to the MC result for all tissue densities higher than soft tissue. In kidneys and spleen, 'constant' and 'density'-scaled DVKs achieved estimated doses with smallest deviations to the full MC gold standard (∼[Formula: see text] underestimation). For low and high density tissue types such as lung and adipose or bone tissue, alternative DVK methods like 'center-voxel'- and 'percentage'- scaled achieved superior results, respectively. Concerning computational load, dose estimation with the DVK method 'constant' needs about 1.1 s per patient, center-voxel scaling amounts to 1.2 s, density scaling needs 1.4 s while percentage scaling consumes 860.3 s per patient. In this study encompassing a large patient cohort and four different DVK estimation methods, no single DVK-adaption method was consistently better than any other in case of soft tissue kernels. Hence in such cases the simplest DVK method, labeled 'constant', suffices. In case of tumors, often located in tissues of low (lung) or high (bone) density, more sophisticated DVK methods excel. The high inter-patient variability indicates that for evaluating new algorithms, a sufficiently large patient cohort needs to be involved.


Asunto(s)
Algoritmos , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Dipéptidos/uso terapéutico , Femenino , Compuestos Heterocíclicos con 1 Anillo/uso terapéutico , Humanos , Lutecio , Masculino , Persona de Mediana Edad , Octreótido/análogos & derivados , Octreótido/uso terapéutico , Antígeno Prostático Específico , Radiofármacos/uso terapéutico , Radioterapia/métodos , Dosificación Radioterapéutica , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos
6.
Eur J Nucl Med Mol Imaging ; 46(10): 1990-2012, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31273437

RESUMEN

PURPOSE: Single-photon emission computed tomography (SPECT) combined with computed tomography (CT) was introduced as a hybrid SPECT/CT imaging modality two decades ago. The main advantage of SPECT/CT is the increased specificity achieved through a more precise localization and characterization of functional findings. The improved diagnostic accuracy is also associated with greater diagnostic confidence and better inter-specialty communication. METHODS: This review presents a critical assessment of the relevant literature published so far on the role of SPECT/CT in a variety of clinical conditions. It also includes an update on the established evidence demonstrating both the advantages and limitations of this modality. CONCLUSIONS: For the majority of applications, SPECT/CT should be a routine imaging technique, fully integrated into the clinical decision-making process, including oncology, endocrinology, orthopaedics, paediatrics, and cardiology. Large-scale prospective studies are lacking, however, on the use of SPECT/CT in certain clinical domains such as neurology and lung disorders. The review also presents data on the complementary role of SPECT/CT with other imaging modalities and a comparative analysis, where available.


Asunto(s)
Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Enfermedades Óseas/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen , Humanos , Neoplasias/diagnóstico por imagen , Enfermedades del Sistema Nervioso/diagnóstico por imagen , Imagen de Perfusión/métodos , Imagen de Perfusión/normas , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas
7.
Ann Nucl Med ; 33(7): 521-531, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31119607

RESUMEN

INTRODUCTION: In any radiotherapy, the absorbed dose needs to be estimated based on two factors, the time-integrated activity of the administered radiopharmaceutical and the patient-specific dose kernel. In this study, we consider the uncertainty with which such absorbed dose estimation can be achieved in a clinical environment. METHODS: To calculate the total error of dose estimation we considered the following aspects: The error resulting from computing the time-integrated activity, the difference between the S-value and the patient specific full Monte Carlo simulation, the error from segmenting the volume-of-interest (kidney) and the intrinsic error of the activimeter. RESULTS: The total relative error in dose estimation can amount to 25.0% and is composed of the error of the time-integrated activity 17.1%, the error of the S-value 16.7%, the segmentation error 5.4% and the activimeter accuracy 5.0%. CONCLUSION: Errors from estimating the time-integrated activity and approximations applied to dose kernel computations contribute about equally and represent the dominant contributions far exceeding the contributions from VOI segmentation and activimeter accuracy.


Asunto(s)
Lutecio/uso terapéutico , Radioisótopos/uso terapéutico , Radiometría , Humanos , Método de Montecarlo , Fantasmas de Imagen , Medicina de Precisión , Dosificación Radioterapéutica , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único
8.
Eur J Hybrid Imaging ; 3(1): 10, 2019 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-34191147

RESUMEN

BACKGROUND: We investigated the clinical performance of a quantitative multi-modal SPECT/CT reconstruction platform for yielding radioactivity concentrations of bone imaging with 99mTc-methylene diphosphonate (MDP) or 99mTc-dicarboxypropane diphosphonate (DPD). The novel reconstruction incorporates CT-derived tissue information while preserving the delineation of tissue boundaries. We assessed image-based reader concordance and confidence, and determined lesion classification and SUV thresholds from ROC analysis. METHODS: Seventy-two cancer patients were scanned at three US and two German clinical sites, each contributing two experienced board-certified nuclear medicine physicians as readers. We compared four variants of the reconstructed data resulting from the Flash3D (F3D) and the xSPECT Bone™ (xB) iterative reconstruction methods and presented images to the readers with and without a fused CT, resulting in four combinations. We used an all-or-none approach for inclusion, compiling results only when a reader completed all reads in a subset. After the final read, we conducted a "surrogate truth" reading, presenting all data to each reader. For any remaining discordant lesions, we conducted a consensus read. We next undertook ROC analysis to determine SUV thresholds for differentiating benign and lesional uptake. RESULTS: On a five-point rating scale of image quality, xB was deemed better by almost two points in resolution and one point better in overall acceptance compared to F3D. The absolute agreement of the rendered decision between the nine readers was significantly higher with CT information either inside the reconstruction (xB, xBCT) or simply through image fusion (F3DCT): 0.70 (xBCT), 0.67 (F3DCT), 0.64 (xB), and 0.46 (F3D). The confidence level to characterize the lesion was significantly higher (3.03x w/o CT, 1.32x w/CT) for xB than for F3D. There was high correlation between xB and F3D scores for lesion detection and classification, but lesion detection confidence was 41% higher w/o CT, and 21% higher w/CT for xB compared to F3D. Without CT, xB had 6.6% higher sensitivity, 7.1% higher specificity, and 6.9% greater AUC compared to F3D, and similarly with CT-fusion. The overall SUV-criterion (SUVc) of xB (12) exceeded that for xSPECT Quant™ (xQ; 9), an approach not using the tissue delineation of xB. SUV critical numbers depended on lesion volume and location. For non-joint lesions > 6 ml, the AUC for xQ and xB was 94%, with SUVc > 9.28 (xQ) or > 9.68 (xB); for non-joint lesions ≤ 6 ml, AUCs were 81% (xQ) and 88% (xB), and SUVc > 8.2 (xQ) or > 9.1 (xB). For joint lesions, the AUC was 80% (xQ) and 83% (xB), with SUVc > 8.61 (xQ) or > 13.4 (xB). CONCLUSION: The incorporation of high-resolution CT-based tissue delineation in SPECT reconstruction (xSPECT Bone) provides better resolution and detects smaller lesions (6 ml), and the CT component facilitates lesion characterization. Our approach increases confidence, concordance, and accuracy for readers with a wide range of experience. The xB method retained high reading accuracy, despite the unfamiliar image presentation, having greatest impact for smaller lesions, and better localization of foci relative to bone anatomy. The quantitative assessment yielded an SUV-threshold for sensitively distinguishing benign and malignant lesions. Ongoing efforts shall establish clinically usable protocols and SUV thresholds for decision-making based on quantitative SPECT.

9.
Eur J Hybrid Imaging ; 2(1): 8, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29782592

RESUMEN

A vast spectrum of lower limb bone and joint disorders (hip, knee, ankle, foot) present with a common clinical presentation: limping. Too often this symptom generates an inefficient cascade of imaging studies. This review attempts to optimise the diagnostic effectiveness of bone scintigraphy using the hybrid SPECT/CT technique in relation to the diagnostic clues provided by other imaging modalities, discusses the appropriate clinical indications, optimal scintigraphic procedures and illustrates updated image pattern-oriented reporting. Frequent lower limb bone and joint pathologies that can now be reliably diagnosed using hybrid bone SPECT/CT imaging will be reviewed. Bone SPECT/CT can be an effective problem-solving tool in patients with persistent limping when careful history taking, clinical examination, and first-line imaging modalities fail to identify the underlying cause.

10.
Nuklearmedizin ; 57(1): 4-17, 2018 02.
Artículo en Alemán | MEDLINE | ID: mdl-29536494

RESUMEN

The present guideline is focused on quality assurance of somatostatin receptor PET/CT (SSTR-PET/CT) in oncology patients. The document has been developed by a multidisciplinary board of specialists providing consensus of definitions, prerequisites, methodology, operating procedures, assessment, and standardized reporting. In particular, imaging procedures for the two most commonly used radioligands of human SSTR, i. e. 68Ga-DOTATOC and 68Ga-DOTATATE are presented. Overall, SSTR-PET/CT requires close interdisciplinary communication and cooperation of referring and executing medical disciplines, taking into account existing guidelines and recommendations of the European and German medical societies, including the European Association of Nuclear Medicine (EANM), German Society for Endocrinology (DGE), German Society for Nuclear Medicine (DGN) and German Society for Radiology (DRG).


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Guías de Práctica Clínica como Asunto , Receptores de Somatostatina/metabolismo , Humanos , Neoplasias/diagnóstico por imagen , Neoplasias/metabolismo , Radiofármacos
11.
Horm Metab Res ; 49(2): 142-146, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27926951

RESUMEN

Familial hypocalciuric hypercalcemia (FHH) belongs to the disorders of a disturbed calcium homeostasis. Genetically, the disorder is inherited in an autosomal-dominant trait and represents an inactivating mutation of the calcium sensing receptor (CaSR) gene. We identified a Franconian kindred in which 6 individuals could be tested by molecular genetic means. In 5 individuals of 3 generations, the mutation could be classified as c.1697_1698delTG. This novel germline mutation creates a premature stop codon leading to a loss of 510 amino acids of the protein. The detection of CaSR gene mutations is suitable to differentiate states of hypercalcemia and may help to avoid invasive procedures such as parathyroidectomies.


Asunto(s)
Exones/genética , Mutación/genética , Receptores Sensibles al Calcio/genética , Anciano , Análisis Mutacional de ADN , Femenino , Alemania , Heterocigoto , Humanos , Masculino , Linaje , Sitios de Empalme de ARN/genética
12.
Eur J Nucl Med Mol Imaging ; 43(9): 1723-38, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27262701

RESUMEN

PURPOSE: The radionuclide bone scan is the cornerstone of skeletal nuclear medicine imaging. Bone scintigraphy is a highly sensitive diagnostic nuclear medicine imaging technique that uses a radiotracer to evaluate the distribution of active bone formation in the skeleton related to malignant and benign disease, as well as physiological processes. METHODS: The European Association of Nuclear Medicine (EANM) has written and approved these guidelines to promote the use of nuclear medicine procedures of high quality. CONCLUSION: The present guidelines offer assistance to nuclear medicine practitioners in optimizing the diagnostic procedure and interpreting bone scintigraphy. These guidelines describe the protocols that are currently accepted and used routinely, but do not include all existing procedures. They should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary.


Asunto(s)
Huesos/diagnóstico por imagen , Medicina Nuclear , Cintigrafía/métodos , Sociedades Médicas , Europa (Continente) , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Guías de Práctica Clínica como Asunto , Embarazo , Control de Calidad , Cintigrafía/efectos adversos , Cintigrafía/normas , Radiofármacos/administración & dosificación , Radiofármacos/efectos adversos , Seguridad
13.
Nuklearmedizin ; 54(4): 173-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26165684

RESUMEN

AIM: Hybrid single-photon emission tomographic (SPECT) and X-ray computed tomography (CT) systems are increasingly used in oncologic imaging. With SPECT/CT not only the thoracic spine but also the surrounding soft tissue needs to be evaluated for pathological findings. The purpose of this study was to assess the prevalence of non-osseous findings detectable on low-dose CT datasets from patients studied by thoracic 99mTc-dicarboxypropane diphosphonate (DPD)-SPECT/CT. PATIENTS, METHODS: 119 consecutive oncologic patients (81 breast cancer, 38 with other cancer) who underwent DPD-SPECT CT of the thoracic region were included in this study. Non-osseous findings on CT were classified as either probably benign or suspicious. Suspicious findings were correlated with retrievable previous imaging and if performed with follow up imaging (MRI, CT with contrast medium, Ultrasound) or biopsy results. RESULTS: In 80/119 (67%) patients no imaging was performed before SPECT/CT. Only 7/119 subjects (6%) had no other lesions than bone lesions. In 101/119 (85%) patients lesions found on SPECT/CT images were rated as benign and in 65/119 (55%) patients as suspicious. In 8/119 (7%) patients with previously unknown suspicious lesions on SPECT/CT images suspicious findings were confirmed by biopsy. CONCLUSION: 7% of patients referred to SPECT/CT of the thoracic spine for staging of malignant disease had previously unknown suspicious non-osseous lesions detectable on the low-dose CT images which were confirmed by biopsy. This could be especially relevant for cancer entities like breast and prostate, in which no thorax-CT is routinely intended for staging.


Asunto(s)
Neoplasias Óseas/diagnóstico , Imagen Multimodal/métodos , Dosis de Radiación , Neoplasias Torácicas/diagnóstico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Hallazgos Incidentales , Masculino , Persona de Mediana Edad , Protección Radiológica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Neoplasias de los Tejidos Blandos/diagnóstico , Adulto Joven
14.
Mol Imaging Biol ; 17(4): 585-93, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25475521

RESUMEN

PURPOSE: The purpose of this study is to extend an established SPECT/CT quantitation protocol to (177)Lu and validate it in vivo using urine samples, thus providing a basis for 3D dosimetry of (177)Lu radiotherapy and improvement over current planar methods which improperly account for anatomical variations, attenuation, and overlapping organs. PROCEDURES: In our quantitation protocol, counts in images reconstructed using an ordered subset-expectation maximization algorithm are converted to kilobecquerels per milliliter using a calibration factor derived from a phantom experiment. While varying reconstruction parameters, we tracked the ratio of image to true activity concentration (recovery coefficient, RC) in hot spheres and a noise measure in a homogeneous region. The optimal parameter set was selected as the point where recovery in the largest three spheres (16, 8, and 4 ml) stagnated, while the noise continued to increase. Urine samples were collected following 12 SPECT/CT acquisitions of patients undergoing [(177)Lu]DOTATATE therapy, and activity concentrations were measured in a well counter. Data was reconstructed using parameters chosen in the phantom experiment, and estimated activity concentration from the images was compared to the urine values to derive RCs. RESULTS: In phantom data, our chosen parameter set yielded RCs in 16, 8, and 4 ml spheres of 80.0, 74.1, and 64.5 %, respectively. For patients, the mean bladder RC was 96.1 ± 13.2% (range, 80.6-122.4 %), with a 95 % confidence interval between 88.6 and 103.6 %. The mean error of SPECT/CT concentrations was 10.1 ± 8.3% (range, -19.4-22.4 %). CONCLUSIONS: Our results show that quantitative (177)Lu SPECT/CT in vivo is feasible but could benefit from improved reconstruction methods. Quantifying bladder activity is analogous to determining the amount of activity in the kidneys, an important task in dosimetry, and our results provide a useful benchmark for future efforts.


Asunto(s)
Neoplasias del Sistema Digestivo , Tumores Neuroendocrinos , Octreótido/análogos & derivados , Compuestos Organometálicos/química , Compuestos Organometálicos/uso terapéutico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Neoplasias del Sistema Digestivo/diagnóstico por imagen , Neoplasias del Sistema Digestivo/radioterapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/radioterapia , Octreótido/química , Octreótido/farmacocinética , Octreótido/uso terapéutico , Octreótido/orina , Compuestos Organometálicos/farmacocinética , Compuestos Organometálicos/orina , Fantasmas de Imagen , Vejiga Urinaria/metabolismo
15.
Exp Clin Endocrinol Diabetes ; 122(5): 273-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24839221

RESUMEN

OBJECTIVE: Metastases of non-thyroidal tumors to the thyroid gland are infrequently diagnosed in the clinical environment. In autopsy studies, however, metastases to the thyroid gland have a frequency of 1.25-24%. The aim of this investigation was to explore the primary tumor and latency of diagnosis in patients who were diagnosed with metastases to the thyroid gland in 70 institutions associated to a scientific board in Middle Franconia during a 12 year period. DESIGN: Retrospective cross-sectional study. PATIENTS: After a clinical data base research, 35 patients (21 male, 14 female) with a histological diagnosis of a secondary thyroid malignancy were identified between 2002 and 2013. The mean age of the patients at diagnosis of the metastasis was x=68.2 years (median: 70, standard deviation SD=± 8.4, range 46-85 years). The majority of the patients had metastases from renal cell carcinomas (n=19). In the other patients metastases from gastrointestinal carcinomas (n=2), bronchial carcinomas (n=3), malignant melanomas (n=3), sarcomas (n=2), and other tumors (n=6) were diagnosed. The time interval between the diagnosis of the primary tumor and the metastasis to the thyroid gland was different for patients with metastases from renal cell carcinomas and non-renal cell carcinomas (p<0.001, chi-test). CONCLUSIONS: In agreement with previous studies, the majority of metastases to the thyroid gland derive from renal cell carcinomas. In patients with non-renal malignancies, metastases to the thyroid gland are diagnosed simultaneously with the primary tumor to a higher proportion compared with metastasis from renal malignancies.


Asunto(s)
Neoplasias de la Tiroides/epidemiología , Neoplasias de la Tiroides/secundario , Anciano , Neoplasias de los Bronquios/epidemiología , Neoplasias de los Bronquios/patología , Carcinoma de Células Renales/epidemiología , Carcinoma de Células Renales/patología , Femenino , Neoplasias Gastrointestinales/epidemiología , Neoplasias Gastrointestinales/patología , Alemania/epidemiología , Humanos , Neoplasias Renales/epidemiología , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Polonia/epidemiología , Estudios Retrospectivos , Sarcoma/epidemiología , Sarcoma/patología , Neoplasias de la Tiroides/patología
16.
Rofo ; 186(5): 489-95, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24718869

RESUMEN

PURPOSE: The purpose of the study was to test the hypothesis that papillary thyroid carcinomas (PTCs) and follicular thyroid carcinomas (FTCs) appear with different ultrasound characteristics. MATERIAL AND METHODS: 90 patients (70 females, 20 males) were included in the study in whom after thyroidectomy the diagnoses of PTCs or FTCs were established. 33 patients (25 females, 8 males) with the diagnosis of follicular adenoma were included in the study as controls (KONs). All patients had ultrasound examinations of the thyroid preoperatively. These ultrasound examinations were evaluated retrospectively with respect to the ultrasound characteristics: "size", "shape", "contour", "structure", "echogenicity" and "calcifications". RESULTS: In PTCs, FTCs and KONs "size" was significantly different (PTCs: MW = 12.5 mm, SD = 8.  mm - FTCs: MW = 35.4 mm, SD = 19.6  mm - KONs: MW = 22.7 mm, SD = 14.5  mm; p <  0.001 for PTCs vs. FTCs, p < 0.001 for PTCs vs. KONs, p = 0.013 for FTCs vs. KONs). Differences were also found with respect to "contour" and "echogenicity" among PTCs, FTCs and KONs (p ≤ 0.035). The parameters "size", "contour", "echogenicity" and "calcifications" correlated for PTCs, FTCs and KONs with a correlation coefficient r = 0.57 (p < 0.05, multivariate regressionanalysis). CONCLUSIONS: PTCs and FTCs appear with different sonographic characteristics. Although there is some overlapping of the sonographic appearances of PTCs and FTCs, the knowledge of these differences should have some impact of the risk adapted further work up.


Asunto(s)
Adenocarcinoma Folicular/diagnóstico por imagen , Carcinoma Papilar/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Adenocarcinoma Folicular/patología , Adenocarcinoma Folicular/cirugía , Adenoma/diagnóstico por imagen , Adenoma/patología , Adenoma/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Papilar/patología , Carcinoma Papilar/cirugía , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Sensibilidad y Especificidad , Estadística como Asunto , Glándula Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/cirugía , Ultrasonografía , Adulto Joven
17.
Nuklearmedizin ; 52(5): 157-62; quiz N55, 2013.
Artículo en Alemán | MEDLINE | ID: mdl-24085458

RESUMEN

This paper describes the guideline for perfusion brain imaging with SPECT-technique published by the Association of the Scientific Medical Societies in Germany (AWMF).The purpose of this guideline is to provide practical assistance for indication, examination procedures, findings and their interpretation also reflecting the present state of the art. Information and instruction are given regarding indication, preparation of the patients and examination procedures of brain perfusion SPECT, including preparation and quality control of the tracer as well as the radiation dosimetry, technical performance of image acquisition with the gamma-camera and image processing. Also advices for interpretation of findings are given. In addition, possible pitfalls are described.


Asunto(s)
Encefalopatías/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Aumento de la Imagen/normas , Medicina Nuclear/normas , Imagen de Perfusión/normas , Tomografía Computarizada de Emisión de Fotón Único/normas , Alemania , Humanos
18.
Acta Neurol Scand ; 127(4): 274-80, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22882005

RESUMEN

PURPOSE: This study aims to investigate the contributions of magnetoencephalography (MEG) in magnetic resonance imaging (MRI)-negative patients. METHODS: A total of 18 MRI-negative patients diagnosed with refractory epilepsy, subjected to MEG investigation, and subsequently underwent surgery were selected for retrospective analysis. A 1.5-tesla Magnetom Sonata with an eight-channel head array coil was used. MEG data were obtained using a 74/248-channel system. RESULTS: A total of 16 patients (16/18) had positive MEG results, comprising 12 patients with monofocal localizations, five with multifocal localizations, and one with unremarkable results in MEG. In addition, 12 patients had indicative single photon-emission computed tomography (SPECT), five had indicative fluorodeoxyglucose positron emission tomography (FDG-PET), and all the patients had intracranial electroencephalography (EEG) (14 with subdural electrodes and four with electrocorticography). The intracranial EEG recordings of nine patients were guided by MEG informative results. Among these 18 patients, 10 exhibited good postoperative outcomes (Engel I and II), four of which were completely seizure-free. All these ten patients had clear monofocal localization in MEG, including nine with accordant indicative metabolic changes in either SPECT or FDG-PET, or both. None of the five patients with multifocal localizations achieved good postoperative outcomes. CONCLUSION: For cases with negative MRI findings, epilepsy surgery may be an alternative option for pharmaco-resistant patients if epileptogenic focus localizations by MEG are present in multimodal evaluation.


Asunto(s)
Encéfalo , Epilepsia/diagnóstico , Imagen por Resonancia Magnética , Magnetoencefalografía , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Encéfalo/fisiopatología , Electroencefalografía , Epilepsia/fisiopatología , Femenino , Fluorodesoxiglucosa F18 , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada de Emisión , Grabación en Video , Adulto Joven
19.
Nuklearmedizin ; 52(1): 1-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23192295

RESUMEN

UNLABELLED: The clinical significance of (18)F-FDG-PET/CT in the follow-up of patients with differentiated thyroid carcinoma was evaluated and the results were compared with those of (18)F-FDG-PET, (131)I-whole-body scintigraphy including SPECT/CT (WBS) and ultrasound. In addition, it was the aim to investigate the impact of (18)F-FDG-PET/CT on the therapeutic management. PATIENTS, METHODS: 327 patients (209 women, 118 men; mean age 53 ± 18 years) with differentiated thyroid cancer (242 papillary, 75 follicular, 6 mixed, 1 Hürthle cell and 3 poorly differentiated tumours) were analyzed retrospectively at four tertiary referral centres. 289 (18)F-FDG-PET/CT and 118 (18)F-FDG-PET studies were performed in these patients between 2007 and 2010. In addition, an overall clinical evaluation was performed, including cytology, histology, thyroglobulin level, ultrasound, WBS, and subsequent clinical course in order to compare the molecular imaging results. Finally, the change in therapeutic management due to findings of (18)F-FDG-PET/CT was investigated. RESULTS: The sensitivity of (18)F-FDG-PET/CT was 92%, the specificity was 95%. Sensitivity and specificity of (18)F-FDG-PET alone were 67% and 93%, respectively. WBS showed a sensitivity of 65% and a specificity of 94%. The corresponding values of ultrasound were 37% and 94%, respectively. The sensitivity of (18)F-FDG-PET/CT in the group of patients with a negative WBS (n=194) amounted to 96%. When (18)F-FDG-PET/CT and WBS were considered in combination, tumour tissue was missed in only 2 out of 133 patients; when (18)F-FDG-PET and WBS were combined, tumour tissue was missed in 1 out of 24 patients. (18)F-FDG-PET/CT resulted in management change in 43% (n=57/133) with a decision on surgical approach in 20% (n=27/133). CONCLUSIONS: (18)F-FDG-PET/CT is superior to (18)F-FDG-PET alone in patients with differentiated thyroid cancer and has a direct impact on the therapeutic management of patients with suspected local recurrence or metastases, particularly in those with negative WBS.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagen Multimodal/estadística & datos numéricos , Tomografía de Emisión de Positrones , Neoplasias de la Tiroides/diagnóstico , Neoplasias de la Tiroides/terapia , Tomografía Computarizada por Rayos X , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Radiofármacos , Estudios Retrospectivos , Factores de Riesgo , Neoplasias de la Tiroides/epidemiología , Resultado del Tratamiento
20.
J Neuroradiol ; 39(2): 87-96, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-21723607

RESUMEN

PURPOSE: This study aimed to investigate the potential contribution of morphometric MRI analysis in comparison to other modalities, such as MEG, SPECT and PET, in identifying the epileptogenic focus in patients with cryptogenic epilepsy. PATIENTS AND METHODS: Study inclusion was limited to epilepsy patients with a monolobar focus hypothesis, as concluded from EEG/seizure semiology and the best individual concordance rate. Feature maps, generated by the MATLAB(®) "morphometric analysis program" (MAP), were evaluated by a neuroradiologist blinded to conventional MRI and the focus hypothesis (MAP(1)). In addition, the feature maps were also interpreted by simultaneous matching conventional MRI but, again, with the reader having no knowledge of the focus hypothesis (MAP(2)). RESULTS: In 12 out of 51 patients, true-positive findings were achieved (MAP(1): sensitivity 24%; specificity 96%). The sensitivity of the MAP(1) results was superior extratemporally. After matching conventional MRI, FCD was traced in six of the 12 patients (MAP(2): sensitivity 12%; specificity 100%). MEG sensitivity was 62%. Sensitivity of interictal and ictal SPECT was 20% and 50%, respectively. PET was not as sensitive extratemporally (19%) as temporally (82%). The greatest correspondence with the best individual concordance rate was noted with PET (14/16; 88%) and MEG (8/10; 80%), followed by interictal (5/8; 63%) and ictal (9/15; 60%) SPECT. Results for MAP(1) were 53% (10/19), and 100% for MAP(2) (6/6). CONCLUSION: Although MAP sensitivity and specificity results are lower in comparison to other modalities, implementation of the technique should be considered first, before arranging any further investigations. The present study results offer guidelines for the implementation, interpretation and concordance of diagnostic procedures.


Asunto(s)
Epilepsia/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Algoritmos , Medios de Contraste , Electroencefalografía , Epilepsia/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador , Magnetoencefalografía , Masculino , Persona de Mediana Edad , Neuroimagen/métodos , Radiofármacos , Sensibilidad y Especificidad , Programas Informáticos , Tomografía Computarizada de Emisión , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...