Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Sports Med ; 32(1): 54-9, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21072747

RESUMEN

This study sought to study the effect of high intensity aerobic interval endurance training on peak stroke volume and maximal strength training on mechanical efficiency in coronary artery disease (CAD) patients. 8 CAD patients (age 61.4 ± 3.7 years) trained 30 interval training sessions with 4 × 4 min intervals at 85-95% of peak heart rate while 10 CAD patients (age 66.5 ± 5.5 years) trained 24 sessions of maximal horizontal leg press. In the interval training group peak stroke volume increased significantly by 23% from 94.1 ± 23.0 mL · beat (-1) to 115.8 ± 22.4 mL · beat (-1) (p<0.05). Peak oxygen uptake increased significantly by 17% from 27.2 ± 4.5 mL · kg (-1) · min (-1) to 31.8 ± 5.0 mL · kg (-1) min (-1) (p<0.05) in the same group. In contrast, there was no such exercise training-induced change in peak stroke volume or peak oxygen uptake in the maximal strength training group, despite a 35% improvement in sub maximal walking performance.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Ejercicio Físico/fisiología , Entrenamiento de Fuerza , Volumen Sistólico/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Esfuerzo Físico/fisiología , Calidad de Vida , Entrenamiento de Fuerza/métodos
2.
Int J Cardiovasc Imaging ; 17(5): 383-93, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12025952

RESUMEN

To assess the relationship between baseline left ventricle function, functional reserve and resting myocardial perfusion in patients with acute myocardial infarction (AMI). After AMI the presence of dysfunctioning but viable myocardium plays a determinant role in clinical outcome. Regional ventricular function was evaluated by echocardiography both in resting conditions and during dobutamine infusion (10 microg/kg/min). Perfusion was assessed by magnetic resonance imaging in a single slice approach where the first pass of an intravenously injected bolus of gadolinium-based contrast agent was followed through six regions of interest within the myocardium. In each patient a region with normal function was used as reference and the cross-correlation coefficient (CCC), which described the myocardial perfusion relatively to the reference region (CCC = 1 means equivalent perfusion), was obtained for the other five myocardial regions. Twenty-two patients were enrolled into the study. Sixty-one segments had normal function and normal perfusion (CCC = 0.92+/-0.23). The perfusion deficit was more marked in the 29 regions with resting akinesia-dyskinesia than in the 20 hypokinetic regions (CCC = 0.71+/-0.45 vs. 0.84+/-0.23; p < 0.05). Out of the 29 regions with resting akinesia-dyskinesia the 13 segments which showed functional improvement following dobutamine had a higher resting perfusion than the 16 segments which were unresponsive to dobutamine (CCC = 0.83+/-0.32 vs. 0.61+/-0.52, p < 0.05). Similarly, out of the 20 regions with resting hypokinesia the 11 segments having functional reserve showed an higher resting perfusion than the segments which did not (0.96+/-0.21 vs. 0.69+/-0.19; p < 0.05). Early after AMI, the perfusion deficit reflects the severity of the mechanical dysfunction. In regions with baseline dyssynergy resting perfusion is, in general, higher when contractile reserve can be elicited by stress-echo.


Asunto(s)
Infarto del Miocardio/fisiopatología , Infarto del Miocardio/cirugía , Reperfusión Miocárdica , Función Ventricular Izquierda/fisiología , Agonistas Adrenérgicos beta , Adulto , Anciano , Medios de Contraste , Angiografía Coronaria , Dobutamina , Ecocardiografía , Femenino , Gadolinio DTPA , Humanos , Italia/epidemiología , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Contracción Miocárdica/fisiología , Infarto del Miocardio/diagnóstico , Noruega/epidemiología , Variaciones Dependientes del Observador , Estadística como Asunto , Factores de Tiempo , Resultado del Tratamiento
3.
Invest Radiol ; 35(5): 295-303, 2000 May.
Artículo en Inglés | MEDLINE | ID: mdl-10803670

RESUMEN

RATIONALE AND OBJECTIVES: To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS: Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein. With the use of a Swan-Ganz catheter, repetitive occlusion/reperfusion maneuvers were done at different locations of the pulmonary arterial tree. Conventional pulmonary angiography, MR angiography, and perfusion MR imaging were performed. RESULTS: The model remained hemodynamically stable throughout the 13 experiments, without any significant difference between the blood pressure measurements at the start and at the end of the right-heart and pulmonary artery catheterizations. In each of the nine animal experiments that investigated MR imaging, four of four using perfusion MR imaging (proximal and distal occlusions) and five of five using MR angiography (larger pulmonary artery occlusions), all repeated pulmonary artery occlusions were successfully performed (reproducibility of 100%). CONCLUSIONS: The closed-chest pulmonary artery occlusion/reperfusion model in the pig allowed repetitive, controlled imitations of pulmonary emboli at different levels of the pulmonary artery in the same experiment. MR angiography and perfusion MR imaging were adequate to detect the pulmonary artery occlusions and the nonperfused lung regions, respectively. The model may be a helpful tool for future research in this field.


Asunto(s)
Modelos Animales de Enfermedad , Imagen por Resonancia Magnética/métodos , Embolia Pulmonar/diagnóstico , Angiografía , Animales , Hemodinámica , Angiografía por Resonancia Magnética , Reproducibilidad de los Resultados , Porcinos
4.
J Magn Reson Imaging ; 9(3): 402-8, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10194710

RESUMEN

A simple two-compartment model was used to study the effects of water exchange on the signal produced by an inversion recovery prepared rapid gradient-echo sequence during the first passage of a low dose of an intravascular contrast agent. Water exchange at intermediate rates of exchange (1-10 Hz) between the vascular and extravascular spaces caused the form of the signal changes during the first pass to be dependent on both the fractional sizes of the vascular and extravascular compartments and on the exchange rate. Unless the effects of exchange are minimized by using a very short inversion time, parameters such as the peak height and area under the curve will be affected by regional and/or pathological variations in the exchange rate and the size of the vascular fraction. The mean transit time (MTT) is, however, less affected by water exchange. Experimental first-pass data produced by intravascular low-dose injections of iron oxide particles were studied in five pigs at 0.5 T. The MTT as derived from the first-pass curves, without deconvolution with the arterial input function, was well correlated with the myocardial blood flow (MBF) as measured using radioactive microspheres (r = 0.70, n = 52, P < 0.01). Other first-pass parameters such as the peak height or area under the curve exhibited either a poorer, or no, correlation with the MBF. The data suggest that the MTT of the first pass of an intravascular contrast agent may be a robust, quantitative method for assessing myocardial blood flow in patients.


Asunto(s)
Agua Corporal/metabolismo , Medios de Contraste/farmacocinética , Vasos Coronarios/fisiopatología , Imagen por Resonancia Magnética/métodos , Animales , Transporte Biológico/fisiología , Velocidad del Flujo Sanguíneo , Inyecciones Intraarteriales , Modelos Biológicos , Reperfusión Miocárdica , Flujo Sanguíneo Regional , Sensibilidad y Especificidad , Porcinos , Factores de Tiempo
5.
J Magn Reson Imaging ; 7(6): 987-95, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9400841

RESUMEN

Myocardial perfusion was assessed in nine pigs using ultrafast gradient-echo MRI (.5 T, 15-mT/m gradients) at different levels of myocardial blood flow (range, .005-1.84 ml/min/g), generated either by adenosine infusion or by a mechanical occluder, and measured independently using radiolabeled microspheres. Sixty-four consecutive, ECG-triggered, diastolic, short axis images of the left ventricle were obtained during intravenous bolus injections (n = 30) of .05 mmol/kg of gadopentetate dimeglumine. Relative changes in peak intensity, time to peak intensity, washin slope, correlation coefficient, and cross-correlation coefficient were computed from the time-intensity curves obtained from four regions of interest, namely septal, anterior, lateral, and inferior walls. The values from the inferior wall acted as reference for evaluating relative changes in the other three regions. The cross-correlation coefficient (P < .001, rho = .60) and the peak intensity (P < .001, r = .72) showed the best correlation with myocardial blood flow. The washin slope showed a weak positive trend (P < .05), but the low value of r (r = .28) indicated that the use of this parameter to predict flow was invalid; the correlation coefficient and time to peak intensity were not correlated (P = ns). In conclusion, this study shows that it is possible to evaluate relative myocardial perfusion after the first pass of a an intravenously injected bolus of gadopentetate dimeglumine, using dynamic MRI on a conventional medium field MRI system. The cross-correlation coefficient and the peak intensity resulted in more efficient parameters to evaluate relative inhomogeneity of regional myocardial perfusion.


Asunto(s)
Circulación Coronaria/fisiología , Imagen por Resonancia Magnética , Adenosina/farmacología , Animales , Medios de Contraste , Interpretación Estadística de Datos , Gadolinio DTPA , Flujo Sanguíneo Regional , Porcinos
6.
Radiology ; 203(1): 181-5, 1997 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-9122390

RESUMEN

PURPOSE: To evaluate the feasibility of magnetic resonance (MR) perfusion imaging in the human lung to help detect perfusion defects distal to suspected pulmonary embolism. MATERIALS AND METHODS: Seven patients suspected of having pulmonary embolism first underwent ventilation-perfusion lung scintigraphy followed by MR perfusion imaging with rapid acquisition of two sets of dynamic images in the coronal and transaxial planes. A bolus of 0.05 mmol per kilogram of body weight gadopentetate dimeglumine or gadodiamide was administered. Single images obtained in each section that showed peak signal intensity from the first passage of contrast material were evaluated visually. An analysis of change in signal intensity over time was performed both on a pixel-by-pixel basis and in selected regions of interest. RESULTS: In the seven patients, a total of 18 regions of lung tissue with perfusion defects were shown on the ventilation-perfusion scans. In 16 of these regions, MR perfusion images showed a reduced peak signal intensity during first passage of the contrast agent. Perfusion defects could be detected in both the coronal and the transaxial planes on MR perfusion images. CONCLUSION: MR perfusion imaging was feasible for detection of perfusion defects distal to a pulmonary embolism.


Asunto(s)
Imagen por Resonancia Magnética , Embolia Pulmonar/diagnóstico , Adulto , Anciano , Medios de Contraste , Combinación de Medicamentos , Estudios de Factibilidad , Femenino , Gadolinio , Gadolinio DTPA , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Masculino , Meglumina , Persona de Mediana Edad , Compuestos Organometálicos , Ácido Pentético/análogos & derivados , Embolia Pulmonar/diagnóstico por imagen , Cintigrafía , Relación Ventilacion-Perfusión
7.
Eur J Vasc Endovasc Surg ; 10(1): 36-9, 1995 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-7633967

RESUMEN

OBJECTIVES: To determine whether alterations in intracranial volume occurred following cross-clamping of the descending thoracic aorta in pigs. DESIGN AND SETTING: Laboratory animal study. MATERIALS: Eight pigs undergoing cross-clamping of the descending thoracic aorta for 30 min. CHIEF OUTCOME MEASURES: A Philips Gyroscan T5-II Release 3 (0.5 T) was used to obtain intracranial images before cross-clamping, during cross-clamping and after declamping. The ventricular volume was measured on Spin Echo T1-weighted images. The signal intensity of the cerebral tissue was measured on Spin Echo T2-weighted images. Increased signal intensity of the cerebral tissue relative to an external reference was used as an indicator of cerebral oedema. MAIN RESULTS: The ventricular volume decreased to 89% (p < 0.01) of the baseline value after 5 min of cross-clamping. At 5 min after declamping the ventricular volume decreased further to 71% (p < 0.01). At 25 min after declamping the ventricular volume had returned to the baseline value. The signal intensity of the cerebral tissue did not differ from baseline values following aortic cross-clamping. CONCLUSIONS: In this study, ventricular volume decreased following cross-clamping of the descending thoracic aorta. Since no cerebral oedema was observed, the decrease of ventricular volume was most likely due to increased intracranial blood volume.


Asunto(s)
Aorta Torácica/fisiopatología , Líquido Cefalorraquídeo/fisiología , Imagen por Resonancia Magnética , Animales , Edema Encefálico/diagnóstico , Edema Encefálico/etiología , Edema Encefálico/fisiopatología , Presión del Líquido Cefalorraquídeo , Constricción , Hemodinámica , Porcinos
8.
Tidsskr Nor Laegeforen ; 111(12): 1500-2, 1991 May 10.
Artículo en Noruego | MEDLINE | ID: mdl-2042183

RESUMEN

Magnetic resonance imaging of the heart has already become an important tool in evaluating the cardiovascular system. This paper describes the basic principles of magnetic resonance imaging, the application of magnetic resonance imaging in the diagnosis of heart diseases, and the experience of using it in Trondheim since 1987. The paper is illustrated by several heart images from Trondheim.


Asunto(s)
Cardiopatías/diagnóstico , Imagen por Resonancia Magnética/métodos , Estudios de Evaluación como Asunto , Humanos
9.
Tidsskr Nor Laegeforen ; 111(13): 1624-5, 1991 May 20.
Artículo en Noruego | MEDLINE | ID: mdl-2063359

RESUMEN

Until recently, invasive angiographic procedures were necessary to verify the diagnosis of anomalous pulmonary venous drainage. Because of their location outside the "acoustic window" these anomalies are unsuitable for echocardiographic examination. Two cases are reported where the diagnosis was confirmed by magnetic resonance tomography (MRT). This method allows an accurate, non-invasive assessment of these structures.


Asunto(s)
Imagen por Resonancia Magnética , Venas Pulmonares/anomalías , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/patología , Radiografía
10.
J Comput Assist Tomogr ; 15(3): 489-91, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-2026817

RESUMEN

A rare case of apical hypertrophic cardiomyopathy with massive left ventricular endomyocardial calcification was studied with MR. The extent of the hypertrophy was clearly demonstrated, enabling accurate estimations of myocardial mass and volumes. Furthermore, an apical calcification was found and its volume estimated. In this case, MR gave the same information that was available by echocardiography, CT, and cardiac catheterization without the disadvantages of these methods.


Asunto(s)
Calcinosis/diagnóstico , Cardiomiopatías/diagnóstico , Cardiomiopatía Hipertrófica/diagnóstico , Calcinosis/complicaciones , Cardiomiopatías/complicaciones , Cardiomiopatía Hipertrófica/complicaciones , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...