Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Vascular ; : 1708538118817666, 2019 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-32522135

RESUMEN

BACKGROUND AND PURPOSE: Carotid artery geometry has been suggested as a risk factor for atherosclerotic carotid disease. Although normal aging and disease development can both lead to geometric changes in the arteries, the exact nature of this phenomenon remains elusive. The aim of our study was to investigate carotid artery geometric changes in a longitudinal study. MATERIAL AND METHODS: We conducted a retrospective study of 114 subjects who underwent carotid contrast-enhanced magnetic resonance angiography at our clinic at baseline (2005 to 2007) and after 10 years. The right (Rev#2-1) carotid arteries were segmented using semi-automated methods to obtain various measurements of carotid artery geometry. For each patient, these parameters were assessed at both time points, including bifurcation angle, internal carotid artery angle, vessel diameter, and circumference. RESULTS: The median age for the total patient population (n = 114) at baseline was 59.06 ± 10.40 years. Mean time interval between baseline magnetic resonance angiography and magnetic resonance angiography after 10 years of these patients was 129.18 ± 7.77 months. For the whole group, there was a significant increase in the bifurcation angle (p < 0.05) over a 10-year period. A significant increase was also noted in the diameter and circumference of the common carotid artery (p < 0.05). However, the other vessel diameters and circumferences (bulb carotid, internal carotid) as well as the internal carotid angle did not significantly change (p ≥ 0.05). CONCLUSION: The diameter and circumference of the common carotid artery and bifurcation angle significantly increased over a decade of life.

2.
Interv Neuroradiol ; 24(6): 674-677, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29969958

RESUMEN

Mechanical thrombectomy is a safe and effective treatment in patients with acute ischemic stroke caused by large vessel occlusions. However, in rare cases, the procedure may be challenging due to the composition of the embolus. We describe a case of a mechanical thrombectomy with the Embolus Retriever with Interlinked Cage (ERIC) device in a patient with an acute ischemic stroke due to calcified cerebral emboli in the middle cerebral artery. The procedure was done after a failed recanalization attempt with manual aspiration thrombectomy. An 82-year-old woman presented to the emergency department with a sudden onset of right-sided weakness. A computed tomographic angiography showed left middle cerebral (M1 branch) calcified emboli. After the administration of an intravenous thrombolytic agent, the patient was transferred to the angiographic suite for a mechanical thrombectomy. After failure to recanalize the vessel with manual aspiration thrombectomy, successful recanalization was achieved via mechanical thrombectomy using the ERIC device. Mechanical thrombectomy with an ERIC device can be a useful option in cases of acute ischemic stroke caused by calcified cerebral emboli.


Asunto(s)
Calcinosis/complicaciones , Revascularización Cerebral/métodos , Embolia Intracraneal/complicaciones , Procedimientos Neuroquirúrgicos/instrumentación , Procedimientos Neuroquirúrgicos/métodos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Angiografía Cerebral , Femenino , Humanos , Embolia Intracraneal/diagnóstico por imagen , Arteria Cerebral Media/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Instrumentos Quirúrgicos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...