Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Ophthalmol ; 20(1): 354, 2020 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-32867721

RESUMEN

BACKGROUND: The measurement of the pupillary function is an indispensable test in some eye examinations, being necessary the evaluation of the precision of instruments performing such measures. The aim of this study was to evaluate the intrasession repeatability of pupil size measurements provided by a multidiagnostic platform in a large sample of healthy eyes. METHODS: This prospective study enrolled 100 healthy eyes of 100 patients, with ages ranging from 23 to 65 years old. Repeated pupil size measures under photopic (P, 220 lx), mesopic (M, 160 lx), low mesopic (L, 70 lx), and scotopic conditions (S, 1 lx) were obtained with the VX120 system (Visionix-Luneau Technologies, Chartres, France) after a complete eye exam. Likewise, pupil size was also measured once in the fellow eye in a total of 75 eyes. The level of intrasession variability as well as differences between fellow eyes were evaluated. RESULTS: Most of differences between repeated measures did not exceed 0.5 mm (82% of S and 100% of P below this value). No significant differences between these repeated measures were found for S (p = 0.099) and L (p = 0.751). However, statistically significant differences were found between repeated measures for M (p = 0.002) and P (p = 0.003). The analysis of clinical relevance of differences between pairs (Passing-Bablok) only confirmed the clinical relevance of differences between the first and second repeated measurement of M. Concerning the comparative analysis between fellow eyes, no statistically significant differences in pupil size were found between right and left eyes in any light condition evaluated (p ≥ 0.227). CONCLUSIONS: The VX120 system can provide consistent measurements of pupil size under scotopic, low mesopic and photopic conditions, with a relative limitation under mesopic conditions.


Asunto(s)
Luz , Pupila , Adulto , Anciano , Francia , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
2.
BMC Ophthalmol ; 17(1): 193, 2017 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-29047369

RESUMEN

BACKGROUND: To evaluate the intrasession repeatability of anterior chamber depth (ACD), central (CCT) and peripheral corneal thickness (PCT), white-to-white diameter (WTW), and irido-corneal angle (IA) measurements obtained with a multidiagnostic device in healthy eyes. METHODS: A total of 107 eyes of 107 patients ranging in age from 23 to 65 years were examined with the VX120 system (Visionix-Luneau Technologies). Three consecutive measurements were obtained with this device to assess the intrasession repeatability of ACD, CCT, PCT at different nasal and temporal locations, WTW, and nasal and temporal IA. Data analysis included the calculation of within-subject standard deviation (Sw), intrasubject precision (1.96xSw), coefficient of variation (CV) and intraclass correlation coefficient (ICC). RESULTS: The Sw and CV for ACD was 0.03 mm and 1.16%, respectively, with an ICC of 0.992. The Sw values for central and peripheral pachymetric measurements were below 9 µm, with CV of less than 1.6% and ICC of 0.976 or higher. For IA measurements, Sw values of 0.84 or lower were found, with a CV between 1 and 2%, and an ICC of more than 0.970. The Sw for WTW was 0.24 mm and the CV was 1.95%. No statistically significant correlations were found between any anatomical parameter evaluated and their Sw and CV values associated (-0.220 ≤ r ≤ 0.204, p ≥ 0.125). CONCLUSIONS: The VX120 system is able to provide repeatable measurements of anatomical parameters in healthy eyes. Inter-observer repeatability should be evaluated in future studies.


Asunto(s)
Cámara Anterior/anatomía & histología , Cuerpo Ciliar/anatomía & histología , Córnea/anatomía & histología , Paquimetría Corneal/instrumentación , Topografía de la Córnea/instrumentación , Iris/anatomía & histología , Adulto , Anciano , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Fotograbar , Reproducibilidad de los Resultados , Adulto Joven
3.
J Ophthalmol ; 2017: 2149145, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28133542

RESUMEN

Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France). Three consecutive measurements were obtained. The within-subject standard deviation (Sw ), intrasubject precision (1.96 × Sw ), and intraclass correlation coefficient (ICC) were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm) was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS) were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689). Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes.

4.
Clin Optom (Auckl) ; 9: 91-96, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-30214365

RESUMEN

PURPOSE: To evaluate the intrasession repeatability of refractive and ocular aberrometric measurements obtained using a new multidiagnostic device in healthy eyes. PATIENTS AND METHODS: A total of 107 eyes of 107 patients, age ranging from 23 to 65 years, were enrolled in this study. A complete eye examination was performed in all eyes, including an ocular examination using the VX120 system. Three consecutive measurements were obtained using this device to assess the intrasession repeatability of different refractive and ocular aber-rometric parameters. The within-subject standard deviation (Sw), intrasubject precision (1.96×Sw), and intraclass correlation coefficient (ICC) were calculated. RESULTS: Sw and intrasubject precision for refractive data were below 0.12 and 0.20 D, respectively, in all cases. The ICC ranged from 0.947 for the J45 power vector component to 0.997 for the sphere. Concerning aberrometric measurements Sw and intrasubject precision values were below 0.05 µm and 0.10 µm, respectively. Likewise, the ICC ranged from 0.805 for the quadrafoil root mean square to 0.954 for the primary spherical aberration. Poor correlations were found between most of the refractive parameters and their Sw (-0.033≤r≤0.053, p≥0.064). Moderate and significant positive correlations were found between the magnitude of the aberrometric parameters evaluated and their Sw (r≥0.446, p<0.001). CONCLUSION: The new multidiagnostic device evaluated is able to provide consistent measurements of refraction and ocular aberrations in healthy eyes. Future studies should confirm if this consistency is also observed in highly aberrated eyes.

5.
Rev Esp Salud Publica ; 82(6): 691-701, 2008.
Artículo en Español | MEDLINE | ID: mdl-19180279

RESUMEN

BACKGROUND: Visual health surveillance is essential in the protection of workers who use video display terminals (VDT). In Spain, the most used is the Specific Health Surveillance Guide published in 1999 by the Ministry of Health. The increase of the scientific production upon computer related occupational visual hazards and the experience in its applicability during the last decade justify the aim of this work: reviewing the quality of the guide from the point of view of visual health. METHODS: A consensus strategy was used among nine experts by means of a mixed groupal technique in two consecutive stages combining some aspects of the Delphi method and of the nominal group: individual evaluation of the guide using the consensus guide made by the authors based on the AGREE instrument and the subsequent meeting in order to reach an agreement and to fix the final recommendations for improving it. For the analysis the standardized score of the review domains was calculated: scope and purpose, stakeholder involvement, rigour of development, clarity and presentation and applicability. It was also calculated for the items.' Concordance in the answers of the experts was also analyzed. RESULTS: All domains obtained scores under 50%. The applicability, rigour and stakeholder involvement during the development of the guide, where the most deficient domains. Six out of the nine experts would not recommend the guide and think it should be remade. CONCLUSIONS: The guide does not reach the necessary quality for the surveillance of the visual health of the workers who use VDT. Efforts must be focussed to improve the guide.


Asunto(s)
Terminales de Computador , Salud Laboral , Guías de Práctica Clínica como Asunto , Visión Ocular , Consenso , Técnica Delphi , Humanos , España
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...