Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Int J Dermatol ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38602089

RESUMEN

BACKGROUND: Erythropoietic protoporphyria (EPP) causes painful light sensitivity, limiting quality of life. Our objective was to develop and validate a wearable light exposure device and correlate measurements with light sensitivity in EPP to predict and prevent symptoms. METHODS: A wearable light dosimeter was developed to capture light doses of UVA, blue, and red wavelengths. A prospective observational pilot study was performed in which five EPP patients wore two light dosimeters for 3 weeks, one as a watch, and one as a shirt clip. RESULTS: Standard deviation (SD) increases from the mean in the daily blue light dose increased the odds ratio (OR) for symptom risk more than the self-reported outdoor time (OR 2.76 vs. 2.38) or other wavelengths, and a one SD increase from the mean in the daily blue light wristband device dose increased the OR for symptom risk more than the daily blue light shirt clip (OR 2.45 vs. 1.62). The area under the receiver operator curve for the blue light wristband dose was 0.78, suggesting 78% predictive accuracy. CONCLUSION: These data demonstrate that wearable blue light dosimetry worn as a wristband is a promising method for measuring light exposure and predicting and preventing symptoms in EPP.

2.
Skin Health Dis ; 3(4): e226, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37538332

RESUMEN

Background: Photodynamic therapy (PDT) is widely used as a treatment for actinic keratoses (AK), with new sunlight-based regimens proposed as alternatives to lamp-based treatments. Prescribing indoor daylight activation could help address the seasonal temperature, clinical supervision, and access variability associated with outdoor treatments. Objective: To compare the AK lesion clearance efficacy of indoor daylight PDT treatment (30 min of 5-aminolevulinic acid (ALA) pre-incubation, followed by 2 h of indoor sunlight) versus a lamp-based PDT treatment (30 min of ALA preincubation, followed by 10 min of red light). Methods: A prospective clinical trial was conducted with 41 patients. Topical 10% ALA was applied to the entire treatment site (face, forehead, scalp). Patients were assigned to either the lamp-based or indoor daylight treatment. Actinic keratosis lesion counts were determined by clinical examination and recorded for pre-treatment, 1-month, and 6-month follow-up visits. Results: There was no statistical difference in the efficacy of AK lesion clearance between the red-lamp (1-month clearance = 57 ± 17%, 6-month clearance = 57 ± 20%) and indoor daylight treatment (1-month clearance = 61 ± 19%, 6-month clearance = 67 ± 20%). A 95% confidence interval of the difference of the means was measured between -4.4% and 13.4% for 1-month, and -2.2% and +23.6% for 6-month timepoints when comparing the indoor daylight to the red-lamp treatment, with a priori interval of equivalence of ±20%. Limitations: Ensuring an equivalent dose between the indoor and lamp treatment cohorts limited randomisation since it required performing indoor daylight treatments only during sunny days. Conclusion: Indoor-daylight PDT provided equivalent AK treatment efficacy to a lamp-based regimen while overcoming temperature limitations and UV-block sunscreen issues associated with outdoor sunlight treatments in the winter. Clinical trial registration: Clinicaltrials.gov listing: NCT03805737.

3.
Photodiagnosis Photodyn Ther ; 41: 103260, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36627070

RESUMEN

SIGNIFICANCE: Skin-based photodynamic therapy (PDT) is used for the clinical treatment of actinic keratosis (AKs) and other skin lesions with continued expansion into the standard of care. Due to the spectral dependency of photosensitizer activation and skin optical fluence, there is a need for more accurate methods to estimate the delivered dose at depth from different PDT light sources and treatment regimens. AIM: Develop radiometric methods for calculating photosensitizer-effective fluence and dose at depth and determine differences between red-lamp, blue-lamp, and daylight-based PDT treatments. METHODS: Radiometric measurements of FDA-approved PDT lamp sources, outdoor daylight, and indoor daylight were performed for clinically relevant AK treatments. The protoporphyrin IX (PpIX) equivalent irradiance, fluence, and dose for each light source were calculated from the PpIX absorption spectrum and a 7-layer skin fluence model. The effective fluence and dose at depth was estimated by combining the spectral attenuation predicted at each wavelength and depth with the source fluence at each wavelength. RESULTS: The red-lamp source had the highest illuminance (112,000 lumen/m2), but lowest PpIX-effective irradiance (9.6 W/m2), and highest effective fluence at depth (10.8 W/m2 at 500 µm). In contrast, the blue light source had the lowest illuminance (2300 lumen/m2), but highest PpIX effective irradiance (37.0 W/m2), and ultimately the lowest effective fluence at depth (0.18 W/cm2 at 500 µm). The daylight source had values of (outdoor | indoor) illuminance of (49,200 | 37,800 lumen/m2), effective irradiance of (19.2 | 10.7 W/m2), and effective fluence of (1.50 | 1.08 W/m2 at 500 µm). The effective fluence and dose at depth facilitated the comparison of treatment regimens, for example, calculating an equivalent dose for a 2 hr indoor daylight treatment and a 10 min red-light treatment for the 300-1000 µm depth range. CONCLUSIONS: The consideration of PpIX-effective fluence at varying depths is necessary to provide adequate comparisons of the delivered dose from PDT light sources. Methods for calculating radiometric fluence and delivered dose at depth were introduced, with open source MATLAB code, to help overcome the limitations of commonly used photometric and irradiance-based reporting.


Asunto(s)
Queratosis Actínica , Fotoquimioterapia , Humanos , Fármacos Fotosensibilizantes/uso terapéutico , Ácido Aminolevulínico/uso terapéutico , Fotoquimioterapia/métodos , Queratosis Actínica/tratamiento farmacológico , Queratosis Actínica/patología
4.
Mol Imaging Biol ; 25(1): 212-220, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36307633

RESUMEN

PURPOSE: Interventional fluorescence imaging is increasingly being utilized to quantify cancer biomarkers in both clinical and preclinical models, yet absolute quantification is complicated by many factors. The use of optical phantoms has been suggested by multiple professional organizations for quantitative performance assessment of fluorescence guidance imaging systems. This concept can be further extended to provide standardized tools to compare and assess image analysis metrics. PROCEDURES: 3D-printed fluorescence phantoms based on solid tumor models were developed with representative bio-mimicking optical properties. Phantoms were produced with discrete tumors embedded with an NIR fluorophore of fixed concentration and either zero or 3% non-specific fluorophore in the surrounding material. These phantoms were first imaged by two fluorescence imaging systems using two methods of image segmentation, and four assessment metrics were calculated to demonstrate variability in the quantitative assessment of system performance. The same analysis techniques were then applied to one tumor model with decreasing tumor fluorophore concentrations. RESULTS: These anatomical phantom models demonstrate the ability to use 3D printing to manufacture anthropomorphic shapes with a wide range of reduced scattering (µs': 0.24-1.06 mm-1) and absorption (µa: 0.005-0.14 mm-1) properties. The phantom imaging and analysis highlight variability in the measured sensitivity metrics associated with tumor visualization. CONCLUSIONS: 3D printing techniques provide a platform for demonstrating complex biological models that introduce real-world complexities for quantifying fluorescence image data. Controlled iterative development of these phantom designs can be used as a tool to advance the field and provide context for consensus-building beyond performance assessment of fluorescence imaging platforms, and extend support for standardizing how quantitative metrics are extracted from imaging data and reported in literature.


Asunto(s)
Neoplasias , Impresión Tridimensional , Humanos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Imagen Óptica , Neoplasias/diagnóstico por imagen
5.
Sci Rep ; 11(1): 17135, 2021 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-34429467

RESUMEN

The 3D printing of fluorescent materials could help develop, validate, and translate imaging technologies, including systems for fluorescence-guided surgery. Despite advances in 3D printing techniques for optical targets, no comprehensive method has been demonstrated for the simultaneous incorporation of fluorophores and fine-tuning of absorption and scattering properties. Here, we introduce a photopolymer-based 3D printing method for manufacturing fluorescent material with tunable optical properties. The results demonstrate the ability to 3D print various individual fluorophores at reasonably high fluorescence yields, including IR-125, quantum dots, methylene blue, and rhodamine 590. Furthermore, tuning of the absorption and reduced scattering coefficients is demonstrated within the relevant mamalian soft tissue coefficient ranges of 0.005-0.05 mm-1 and 0.2-1.5 mm-1, respectively. Fabrication of fluorophore-doped biomimicking and complex geometric structures validated the ability to print feature sizes less than 200 µm. The presented methods and optical characterization techniques provide the foundation for the manufacturing of solid 3D printed fluorescent structures, with direct relevance to biomedical optics and the broad adoption of fast manufacturing methods in fluorescence imaging.


Asunto(s)
Resinas Acrílicas/química , Impresión Tridimensional/instrumentación , Absorción de Radiación , Resinas Acrílicas/efectos de la radiación , Fluorescencia , Colorantes Fluorescentes/química
6.
J Biomed Opt ; 25(11)2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33185051

RESUMEN

PURPOSE: Unlike fluorescence imaging utilizing an external excitation source, Cherenkov emissions and Cherenkov-excited luminescence occur within a medium when irradiated with high-energy x-rays. Methods to improve the understanding of the lateral spread and axial depth distribution of these emissions are needed as an initial step to improve the overall system resolution. METHODS: Monte Carlo simulations were developed to investigate the lateral spread of thin sheets of high-energy sources and compared to experimental measurements of similar sources in water. Additional simulations of a multilayer skin model were used to investigate the limits of detection using both 6- and 18-MV x-ray sources with fluorescence excitation for inclusion depths up to 1 cm. RESULTS: Simulations comparing the lateral spread of high-energy sources show approximately 100 × higher optical yield from electrons than photons, although electrons showed a larger penumbra in both the simulations and experimental measurements. Cherenkov excitation has a roughly inverse wavelength squared dependence in intensity but is largely redshifted in excitation through any distance of tissue. The calculated emission spectra in tissue were convolved with a database of luminescent compounds to produce a computational ranking of potential Cherenkov-excited luminescence molecular contrast agents. CONCLUSIONS: Models of thin x-ray and electron sources were compared with experimental measurements, showing similar trends in energy and source type. Surface detection of Cherenkov-excited luminescence appears to be limited by the mean free path of the luminescence emission, where for the given simulation only 2% of the inclusion emissions reached the surface from a depth of 7 mm in a multilayer tissue model.


Asunto(s)
Luminiscencia , Fotones , Método de Montecarlo , Fantasmas de Imagen , Rayos X
7.
J Biomed Opt ; 25(5): 1-15, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32441066

RESUMEN

SIGNIFICANCE: Expanded use of fluorescence-guided surgery with devices approved for use with indocyanine green (ICG) has led to a range of commercial systems available. There is a compelling need to be able to independently characterize system performance and allow for cross-system comparisons. AIM: The goal of this work is to expand on previous proposed fluorescence imaging standard designs to develop a long-term stable phantom that spectrally matches ICG characteristics and utilizes 3D printing technology for incorporating tissue-equivalent materials. APPROACH: A batch of test targets was created to assess ICG concentration sensitivity in the 0.3- to 1000-nM range, tissue-equivalent depth sensitivity down to 6 mm, and spatial resolution with a USAF test chart. Comparisons were completed with a range of systems that have significantly different imaging capabilities and applications, including the Li-Cor® Odyssey, Li-Cor® Pearl, PerkinElmer® Solaris, and Stryker® Spy Elite. RESULTS: Imaging of the ICG-matching phantoms with all four commercially available systems showed the ability to benchmark system performance and allow for cross-system comparisons. The fluorescence tests were able to assess differences in the detectable concentrations of ICG with sensitivity differences >10× for preclinical and clinical systems. Furthermore, the tests successfully assessed system differences in the depth-signal decay rate, as well as resolution performance and image artifacts. The manufacturing variations, photostability, and mechanical design of the tests showed promise in providing long-term stable standards for fluorescence imaging. CONCLUSIONS: The presented ICG-matching phantom provides a major step toward standardizing performance characterization and cross-system comparisons for devices approved for use with ICG. The developed hybrid manufacturing platform can incorporate long-term stable fluorescing agents with 3D printed tissue-equivalent material. Further, long-term testing of the phantom and refinements to the manufacturing process are necessary for future implementation as a widely adopted fluorescence imaging standard.


Asunto(s)
Verde de Indocianina , Imagen Óptica , Fantasmas de Imagen
8.
Phys Med Biol ; 65(9): 095004, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-32135522

RESUMEN

This study demonstrates remote imaging for in vivo detection of radiation-induced tumor microstructural changes by tracking the diffusive spread of injected intratumor UV excited tattoo ink using Cherenkov-excited luminescence imaging (CELI). Micro-liter quantities of luminescent tattoo ink with UV absorption and visible emission were injected at a depth of 2 mm into mouse tumors prior to receiving a high dose treatment of radiation. X-rays from a clinical linear accelerator were used to excite phosphorescent compounds within the tattoo ink through Cherenkov emission. The in vivo phosphorescence was detected using a time-gated intensified CMOS camera immediately after injection, and then again at varying time points after the ink had broken down with the apoptotic tumor cells. Ex vivo tumors were imaged post-mortem using hyperspectral cryo-fluorescence imaging to quantify necrosis and compared to Cherenkov-excited light imaging of diffusive ink spread measured in vivo. Imaging of untreated control mice showed that ink distributions remained constant after four days with less than 3% diffusive spread measured using full width at 20% max. For all mice, in vivo CELI measurements matched within 12% of the values estimated by the high-resolution ex vivo sliced luminescence imaging of the tumors. The tattoo ink spread in treated mice was found to correlate well with the nonperfusion necrotic core volume (R2 = 0.92) but not well with total tumor volume changes (R2 = 0.34). In vivo and ex vivo findings indicate that the diffusive spread of the injected tattoo ink can be related to radiation-induced necrosis, independent of total tumor volume change. Tracking the diffusive spread of the ink allows for distinguishing between an increase in tumor size due to new cellular growth and an increase in tumor size due to edema. Furthermore, the imaging resolution of CELI allows for in vivo tracking of subtle microenvironmental changes which occur earlier than tumor shrinkage and this offers the potential for novel, minimally invasive radiotherapy response assay without interrupting a singular clinical workflow.


Asunto(s)
Neoplasias de Cabeza y Cuello/patología , Neoplasias de Cabeza y Cuello/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Tinta , Luminiscencia , Fantasmas de Imagen , Animales , Proliferación Celular , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Ratones , Ratones Desnudos , Células Tumorales Cultivadas , Rayos X , Ensayos Antitumor por Modelo de Xenoinjerto
9.
JCO Glob Oncol ; 6: 453-461, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32160013

RESUMEN

PURPOSE: To evaluate the feasibility of brigade-style, multiphasic cancer screening in Honduras, exploring data from 3 screening events that each tested for multiple cancers on single occasions. METHODS: This series of 3 studies each used a single-arm, post-test-only design to explore the feasibility of implementing multiphasic, community-based cancer screening at the same rural location in 2013, 2016, and 2017. The 2013 event for women screened for 2 cancers (breast and cervix), and the 2016 event for women screened for 3 cancers (breast, cervix, and thyroid). The 2017 event for men screened for 5 cancers (skin, prostate, colorectal, oropharynx, and testes). RESULTS: Totals of 473 and 401 women participated in the 2013 and 2016 events, respectively, and 301 men participated in the 2017 event. Staffing for each event varied from 33 to 44 people and relied primarily on in-country medical students and local community members. High rates (mean, 88%) of compliance with referral for follow-up testing at clinics and primary care facilities were observed after the screening events. CONCLUSION: The multiphasic, community-based approach proved feasible for both women and men and resulted in high rates of compliance with follow-up testing. This approach appears highly replicable: it was conducted multiple times across the years with different screening targets, which could be further scaled elsewhere using the same technique.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias , Estudios de Factibilidad , Femenino , Honduras/epidemiología , Humanos , Masculino , Tamizaje Multifásico , Neoplasias/diagnóstico , Neoplasias/epidemiología
10.
Med Phys ; 47(4): 1807-1812, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32056218

RESUMEN

PURPOSE: Tattoo fiducials are commonly used in radiotherapy patient alignment, and recent studies have examined the use of UV-excited luminescent tattoo ink as a cosmetic substitute to make these visible under UV illumination. The goal of this study was to show how luminescent tattoo inks could be excited with MV radiation and imaged during beam delivery for direct visualization of field position. METHODS: A survey of nine UV-sensitive tattoo inks with various emission spectra were investigated using both UV and MV excitation. Images of liquid solutions were collected under MV excitation using an intensified-CMOS imager. Solid skin-simulating phantoms were imaged with both surface-painted ink and in situ tattooing during dose delivery by both a clinical linear accelerator and cobalt-60 source. RESULTS: The UV inks have peak fluorescence emission ranging from approximately 440 to 600 nm with lifetimes near 11-16 µs. The luminescence intensity is approximately 6x higher during the x-ray pulse than after the pulse, however, the signal-to-noise is only approximately twice as large. Spatial resolution for imaging was achieved at 1.6 mm accuracy in a skin test phantom. Optical filtering allows for continuous imaging using a cobalt source and provides a mechanism to discriminate ink colors using a monochromatic image sensor. CONCLUSIONS: This study demonstrates how low-cost inks can be used as fiducial markers and imaged both using time-gated and continuous modes during MV dose delivery. Phantom studies demonstrate the potential application of real-time field verification. Further studies are required to understand if this technique could be used as a tool for radiation dosimetry.


Asunto(s)
Cobalto/uso terapéutico , Tinta , Luminiscencia , Aceleradores de Partículas , Radioterapia Guiada por Imagen/métodos , Tatuaje , Marcadores Fiduciales , Fantasmas de Imagen , Rayos Ultravioleta
11.
Photodiagnosis Photodyn Ther ; 30: 101637, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31899377

RESUMEN

BACKGROUND: X-Ray induced phototherapy is highly sought after as it provides a deep tissue, synergistic method of treating cancers via standard-of-care radiotherapy. When this is combined with releasable chemotherapy agents, it can provide high target selectivity, with reduced off-target organ effects that limit current systemic therapies. We have recently developed a unique light-activated drug delivery system whereby the drug is conjugated to an alkylcobalamin scaffold. Alkylcobalamins are actively transported into cells by transcobalamin receptors (TCblR), which are overexpressed in a variety of cancer types. We hope to utilize this cobalamin scaffold technology for drug delivery in pancreatic adenocarcinoma (PDAC) cancer. METHODS: The ability of the cobalamin scaffold to selectively target PDAC was investigated by treating mice that had MIA PaCa-2 xenografts with an alkylcobalamin labeled with the fluorophore Bodipy650 (Bodipy650-cobalamin). The mice were imaged alive and organs as well as tumors were subsequently imaged ex vivo. In addition, we examined the potential of the cobalamin scaffold to deliver drugs to orthotopic pancreas MIA PaCa-2 tumors with Bodipy650-cobalamin. We determined the light dose required for release of cargo from the cobalamin scaffold by examining the fluorescence increase of Bodipy650-cobalamin in response to red light (650 nm). Finally, we probed the ability of the cobalamin scaffold to release cargo with increasing X-ray doses from a clinical linear accelerator. RESULTS: We have found that Bodipy650-cobalamin was shown to localize in MIA PaCa-2 tumors, both in flank and orthotopic models. We quantified a light dose for red light release from the cobalamin scaffold that is within normal clinical doses required for photodynamic therapy. This derivative was also activated with clinical X-ray doses from a linear accelerator. CONCLUSIONS: Tumor selectivity combined with fluorescence detection demonstrates the effectiveness of the vitamin B12 scaffold as a theranostic targeting agent. The activation of this scaffold with radiation from a linear accelerator shows potential for action as radiation-induced chemotherapy.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Fotoquimioterapia , Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/radioterapia , Animales , Ratones , Neoplasias Pancreáticas/tratamiento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Vitamina B 12 , Rayos X
12.
Photochem Photobiol ; 96(2): 320-326, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31581341

RESUMEN

Daylight activation for photodynamic therapy (PDT) of skin lesions is now widely adopted in many countries as a less painful and equally effective treatment mechanism, as compared to red or blue light activation. However, seasonal daylight availability and transient weather conditions complicate light dose estimations. A method is presented for dose planning without placing a large burden on clinical staff, by limiting spectral measurements to a one-time site assessment, and then using automatically acquired weather reports to track transient conditions. The site assessment tools are used to identify appropriate treatment locations for the annual and daily variations in sunlight exposure for clinical center planning. The spectral information collected from the site assessment can then be integrated with real-time daily electronic weather data. It was shown that a directly measured light exposure has strong correlation (R2 : 0.87) with both satellite cloud coverage data and UV index, suggesting that the automated weather indexes can be surrogates for daylight PDT optical dose. These updated inputs can be used in a dose-planning treatment model to estimate photodynamic dose at depth in tissue. A simple standardized method for estimating light dose during daylight-PDT could help improve intersite reproducibility while minimizing treatment times.


Asunto(s)
Luz , Modelos Teóricos , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Tiempo (Meteorología) , Relación Dosis-Respuesta a Droga , Relación Dosis-Respuesta en la Radiación , Humanos , Luz Solar
13.
Photodiagnosis Photodyn Ther ; 25: 425-435, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30685548

RESUMEN

BACKGROUND: Daylight-activated PDT has seen increased support in recent years as a treatment method for actinic keratosis and other non-melanoma skin cancers. The inherent variability observed in broad-spectrum light used in this methodology makes it difficult to plan and monitor light dose, or compare to lamp light doses. METHODS: The present study expands on the commonly used PpIX-weighted effective surface irradiance metric by introducing a Monte Carlo method for estimating effective fluence rates into depths of the skin. The fluence rates are compared between multiple broadband and narrowband sources that have been reported in previous studies, and an effective total fluence for various treatment times is reported. A dynamic estimate of PpIX concentration produced during pro-drug incubation and treatment is used with the fluence estimates to calculate a photodynamic dose. RESULTS: Even when there is up to a 5x reduction between the effective surface irradiance of the broadband light sources, the effective fluence below 250 µm depth is predicted to be relatively equivalent. An effective threshold fluence value (0. 70Jeff/cm2) is introduced based on a meta-analysis of previously published ALA-PpIX induced cell death. This was combined with a threshold PpIX concentration (50 nM) to define a threshold photodynamic dose of 0.035 u M Jeff/cm2. CONCLUSIONS: The threshold was used to generate lookup tables to prescribe minimal treatment times to achieve depth-dependent cytotoxic effect based on incubation times and irradiance values for each light source.


Asunto(s)
Ácido Aminolevulínico/farmacología , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/farmacología , Profármacos/farmacología , Protoporfirinas/metabolismo , Piel/efectos de los fármacos , Ácido Aminolevulínico/administración & dosificación , Ácido Aminolevulínico/farmacocinética , Muerte Celular/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Humanos , Queratosis Actínica/tratamiento farmacológico , Modelos Biológicos , Método de Montecarlo , Fármacos Fotosensibilizantes/administración & dosificación , Fármacos Fotosensibilizantes/farmacocinética , Profármacos/administración & dosificación , Profármacos/farmacocinética , Valores de Referencia , Neoplasias Cutáneas/tratamiento farmacológico , Factores de Tiempo
14.
J Glob Oncol ; 4: 1-8, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30241169

RESUMEN

PURPOSE: Cervical cancer is a leading cause of cancer-related mortality in low- and middle-income countries (LMICs) and screening in LMICs is extremely limited. We aimed to implement on-site high-risk human papillomavirus (hrHPV) DNA testing in cohorts of women from an urban factory and from a rural village. METHODS: A total of 802 women were recruited for this study in partnership with La Liga Contra el Cancer through the establishment of women's health resource fairs at two locations in Honduras: a textile factory (n = 401) in the city of San Pedro Sula and the rural village of El Rosario (n = 401) in Yoro. Participants received a routine cervical examination during which three sterile cytobrushes were used to collect cervical samples for testing. hrHPV genotyping was performed using a hrHPV genotyping assay and a real-time polymerase chain reaction instrument. RESULTS: hrHPV status across all participants at both sites was 13% hrHPV positive and 67% hrHPV negative. When hrHPV status was compared across all three testing sites, hrHPV-positive rates were approximately equal among the factory (13%), village (12%), and confirmatory testing at Dartmouth-Hitchcock Medical Center (Lebanon, NH; 14%). hrHPV genotype was compared across sites, with HPV16 showing the highest infection rate (15%), followed by HPV59 (12%), and HPV68 (11%). There was a low prevalence of HPV18 observed in both populations compared with the hrHPV-positive population in the United States. CONCLUSION: In collaboration with oncologists and pathologists from La Liga Contra el Cancer, we were able to provide a continuum of care once health-fair testing was performed. We established a method and implementation plan for hrHPV testing that is sustainable in LMICs.


Asunto(s)
Infecciones por Papillomavirus/diagnóstico , Neoplasias del Cuello Uterino/diagnóstico , Adulto , ADN Viral , Países en Desarrollo , Detección Precoz del Cáncer , Femenino , Genotipo , Humanos , Persona de Mediana Edad , Papillomaviridae/genética , Infecciones por Papillomavirus/virología , Educación del Paciente como Asunto , Proyectos Piloto , Reacción en Cadena de la Polimerasa , Neoplasias del Cuello Uterino/virología
15.
Exp Mol Pathol ; 104(2): 146-150, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29551573

RESUMEN

Cervical cancer rates in low- and middle-income countries (LMICs) are higher than in developed countries and account for 80% of an estimated 500,000 new cases annually. Factors that contribute to this are that diagnostic and prevention strategies designed for developed countries suffer from the combination of low vaccination rates and limitations due to lack of consistent access to both healthcare and supplies. Here we: 1) improve upon our LMIC deployable HPV test and 2) determine both the high and low-risk HPV genotype prevalence in an isolated Honduran population. We found an unexpected HPV distribution with an abundance of HPV 52 and HPV 72 infections. In this context, molecular testing using a LMIC deployable approach for the detection of HPV can aid in both the triage of HPV positive cytology-based follow up and provide information regarding HPV genotype distribution in support of vaccination strategies.


Asunto(s)
Papillomaviridae/genética , Infecciones por Papillomavirus/virología , Virología/métodos , Países en Desarrollo , Femenino , Honduras , Humanos , Papillomaviridae/patogenicidad , Infecciones por Papillomavirus/epidemiología , Prevalencia , Salud Rural , Población Rural
16.
Phys Med Biol ; 63(8): 085019, 2018 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-29558363

RESUMEN

During external beam radiotherapy (EBRT), in vivo Cherenkov optical emissions can be used as a dosimetry tool or to excite luminescence, termed Cherenkov-excited luminescence (CEL) with microsecond-level time-gated cameras. The goal of this work was to develop a complete theoretical foundation for the detectable signal strength, in order to provide guidance on optimization of the limits of detection and how to optimize near real time imaging. The key parameters affecting photon production, propagation and detection were considered and experimental validation with both tissue phantoms and a murine model are shown. Both the theoretical analysis and experimental data indicate that the detection level is near a single photon-per-pixel for the detection geometry and frame rates commonly used, with the strongest factor being the signal decrease with the square of distance from tissue to camera. Experimental data demonstrates how the SNR improves with increasing integration time, but only up to the point where the dominance of camera read noise is overcome by stray photon noise that cannot be suppressed. For the current camera in a fixed geometry, the signal to background ratio limits the detection of light signals, and the observed in vivo Cherenkov emission is on the order of 100× stronger than CEL signals. As a result, imaging signals from depths <15 mm is reasonable for Cherenkov light, and depths <3 mm is reasonable for CEL imaging. The current investigation modeled Cherenkov and CEL imaging of two oxygen sensing phosphorescent compounds, but the modularity of the code allows for easy comparison of different agents or alternative cameras, geometries or tissues.


Asunto(s)
Luminiscencia , Imagen Óptica/métodos , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...