Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
1.
Ophthalmol Ther ; 13(6): 1537-1551, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38587775

RESUMEN

INTRODUCTION: Even though the local tolerance of prostaglandin (PG) analogues has improved drastically since the introduction of preservative-free (PF) eye drops, prescription patterns still vary widely among practitioners and between countries and could have an impact on the ocular surface of treated patients and, in consequence, their adherence. The aim of this study is to explore the prescribing patterns of PG analogues monotherapy in France and to evaluate their impact on ocular surface status. METHODS: This was a national multicenter cross-sectional observational study that was conducted by 18 glaucoma experts in France. Patients over 18 years of age and receiving monotherapy with topical PG analogues for the treatment of ocular hypertension and/or glaucoma, with no history of prior glaucoma surgery, were consecutively selected from the glaucoma outpatient clinics of participating physicians and underwent an ocular surface examination. RESULTS: A total of 344 eyes of 344 patients were enrolled between November 2022 and November 2023. Prescribed PG monotherapy was PF in 271 (78.7%) patients. Clinical history and ocular surface evaluation indicated that 79.4% of the study population (n = 273) presented with at least one symptom or clinical sign of dry eye and that three patients out of four had an unstable tear film. Subgroup analysis comparing preserved and PF PG analogues showed a higher prevalence of conjunctival hyperemia and corneal staining in the preserved group. Multivariate analysis identified conjunctival hyperemia as consistently associated with preservative use (odds ratio = 7.654; p = 0.003 for moderate conjunctival hyperemia). CONCLUSIONS: This study highlights the growing trend toward PF PG analogue prescriptions by specialists in France. However, ocular surface issues remain prevalent, impacting patient adherence and treatment efficacy. Comprehensive ocular surface examinations are crucial in glaucoma management to enhance long-term tolerance, compliance, and overall treatment success.

2.
J Glaucoma ; 32(12): 1052-1057, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37974323

RESUMEN

PRCIS: The iStent inject W implanted during phacoemulsification effectively reduces IOP. PURPOSE: The purpose of this study was to evaluate the efficacy and safety of iStent inject W combined with phacoemulsification in patients with controlled open angle glaucoma undergoing cataract surgery. PATIENTS AND METHODS: We conducted a retrospective, bicentric study of patients with controlled chronic open angle glaucoma who underwent phacoemulsification combined with the injection of 2 iStent inject Ws. Patient characteristics, including intraocular pressure (IOP) and the number of glaucoma medications, were evaluated preoperatively and 1 week, 1 month, and 6 months postoperatively. The primary end point was IOP reduction, and the secondary end point was the reduction in the number of glaucoma medications. RESULTS: In this study, 85 eyes were included. The majority of patients had primary open angle glaucoma (85% of eyes). Preoperative mean IOP was 16.1±2.0 mm Hg with a mean of 2.3±0.5 glaucoma medications. At 1 week postoperatively, the mean IOP was 16.7±3.1 mm Hg with a mean of 2.0±0.7 hypotensive medications. At 1 and 6 months, the mean IOP was 14.2±2.1 and 13.0±1.5 mm Hg, with a mean of 2.0±0.6 and 1.8±0.5 glaucoma medications, respectively. The percentage IOP reduction at 1 and 6 months was 11.6% ( P =0.001) and 19.3% ( P <0.0001), respectively. Regarding glaucoma medications, at 1 and 6 months, the reduction in the number of medications was 12.9% ( P =0.025) and 22.4% ( P =0.003), respectively. The most frequent significant postoperative adverse events were corneal edema in 7%, IOP spikes in 6%, and hyphema in 6% of eyes, which resolved spontaneously. CONCLUSIONS: The iStent inject W implanted during phacoemulsification effectively reduces IOP and the number of glaucoma medications needed at 6 months of follow-up, with a favorable safety profile in patients with controlled open angle glaucoma.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Hipotensión Ocular , Facoemulsificación , Humanos , Glaucoma de Ángulo Abierto/complicaciones , Glaucoma de Ángulo Abierto/cirugía , Presión Intraocular , Estudios Retrospectivos , Glaucoma/cirugía , Malla Trabecular/cirugía , Hipotensión Ocular/cirugía
3.
BMC Ophthalmol ; 23(1): 417, 2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37845645

RESUMEN

RATIONALE: Nd:YAG (neodymium:yttrium-aluminum-garnet) capsulotomy (Nd:YAG-caps) is the gold standard for the treatment of PCO (Posterior Capsule Opacification). There is a lack of real-world data about Nd:YAG-caps use. PURPOSE: This study's objectives were to estimate Nd:YAG-caps incidence in France, to describe the patient characteristics, and to analyze the time between surgeries and capsulotomies. SETTING: The study was based on data extracted from the EGB database, a 1/97th sample representative of the French population. DESIGN: observational, retrospective, cohort study using national claims data. METHODS: French adult patients who underwent Nd:YAG-caps between 2014 and 2017 were selected. Main outcomes were the number of patients and procedures performed and the risk factors associated with early Nd:YAG-caps. RESULTS: During the study period, Nd:YAG-caps were performed in 8,425 patients accounting for 10,774 procedures. The extrapolation to the French population led to estimate that 253.103 patients had Nd:YAG-caps, representing 312.103 procedures in 2017. The mean age at Nd:YAG-caps was 75.1 (± 10.2) years. About 36% of patients presented at least one ocular comorbidity. Nd:YAG-caps was performed within 2 years after surgery in 33.0% of patients and within one year in 9.8% of patients. Patients with Nd:YAG-caps within the first year (OR CI95 0.721 [0.673-0.772]) or in the first two years (OR CI95 0.721 [0.673-0.772]) were younger than patients with later Nd:YAG-caps and had a more frequent history of treated ocular diseases (OR 1.516 and 1.178, respectively). CONCLUSIONS: This study brought new real-world and large-scale data regarding Nd:YAG-caps use and gave an updated insight into the patients' characteristics.


Asunto(s)
Opacificación Capsular , Terapia por Láser , Láseres de Estado Sólido , Cápsula del Cristalino , Lentes Intraoculares , Adulto , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Estudios de Cohortes , Láseres de Estado Sólido/uso terapéutico , Incidencia , Cápsula del Cristalino/cirugía , Complicaciones Posoperatorias/etiología , Terapia por Láser/efectos adversos , Opacificación Capsular/epidemiología , Opacificación Capsular/etiología , Opacificación Capsular/cirugía
4.
Curr Eye Res ; 48(12): 1089-1099, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37661784

RESUMEN

PURPOSE: To provide an overview of the existing alternative models for studying trabecular meshwork (TM). METHODS: Literature review. RESULTS: The TM is a complex tissue that regulates aqueous humor outflow from the eye. Dysfunction of the TM is a major contributor to the pathogenesis of open-angle glaucoma, a leading cause of irreversible blindness worldwide. The TM is a porous structure composed of trabecular meshwork cells (TMC) within a multi-layered extracellular matrix (ECM). Although dysregulation of the outflow throughout the TM represents the first step in the disease process, the underlying mechanisms of TM degeneration associate cell loss and accumulation of ECM, but remain incompletely understood, and drugs targeting the TM are limited. Therefore, experimental models of glaucomatous trabeculopathy are necessary for preclinical screening, to advance research on this disease's pathophysiology, and to develop new therapeutic strategies targeting the TM. Traditional animal models have been used extensively, albeit with inherent limitations, including ethical concerns and limited translatability to humans. Consequently, there has been an increasing focus on developing alternative in vitro models to study the TM. Recent advancements in three-dimensional cell culture and tissue engineering are still in their early stages and do not yet fully reflect the complexity of the outflow pathway. However, they have shown promise in reducing reliance on animal experimentation in certain aspects of glaucoma research. CONCLUSION: This review provides an overview of the existing alternative models for studying TM and their potential for advancing research on the pathophysiology of open-angle glaucoma and developing new therapeutic strategies.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Animales , Humanos , Malla Trabecular/metabolismo , Glaucoma de Ángulo Abierto/metabolismo , Humor Acuoso/metabolismo , Matriz Extracelular/metabolismo , Presión Intraocular
6.
BMC Ophthalmol ; 23(1): 318, 2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37452284

RESUMEN

PURPOSE: To describe imaging characteristics of severe macular complications occurring in glaucoma and discuss available treatments. METHODS: Retrospective case series of glaucomatous patients with macular retinoschisis (MR) and/or serous retinal detachment (SRD). Patients underwent a complete ophthalmological examination and multimodal imaging including retinography, SD-OCT, fluorescein and indocyanine green angiography (FA & ICGA) and adaptive optics (AO). RESULTS: Ten eyes (8 patients) were included. Initial BCVA was 1.04 ± 1.12 logMAR and IOP was 24.0 ± 9.3mmHg. All eyes presented with MR while SRD was present in 5 eyes (5 patients), with a central macular thickness of 573 ± 152 µm. FA and ICGA allowed to exclude leakage in all cases. A focal lamina cribrosa defect (LCD) was found in four eyes (4 patients) using OCT, with AO providing en-face visualization of the defect in one eye. Outer retinal hole was present in 3 eyes (3 patients). No visual improvement or resolution of the macular retinoschisis was observed in eyes with medical or surgical IOP control (N = 9). Vitrectomy with internal membrane limiting peeling and gas tamponade was performed in one eye with good visual results. CONCLUSIONS: Multimodal high-resolution imaging is essential to diagnose severe macular complications associated with advanced glaucoma.


Asunto(s)
Glaucoma , Desprendimiento de Retina , Perforaciones de la Retina , Retinosquisis , Humanos , Retinosquisis/diagnóstico , Estudios Retrospectivos , Desprendimiento de Retina/cirugía , Glaucoma/cirugía , Perforaciones de la Retina/cirugía , Tomografía de Coherencia Óptica , Vitrectomía/métodos , Imagen Multimodal
7.
J Clin Med ; 12(4)2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36836063

RESUMEN

Purpose: Describe the cognitive and behavioral symptomatology of patients with chronic ocular rubbing in keratoconus (KC) and Ocular Surface Disease (OSD) using a self-questionnaire. Methods: A prospective study was conducted in a tertiary ophthalmology center between May and July 2021. We consecutively included all patients presenting with one of the following conditions: KC and OSD. A questionnaire including the evaluation of Goodman and CAGE-modified criteria for eye rubbing was given to patients in consultation to evaluate their ocular symptoms and medical background. Results: We included 153 patients in the study. Of these, 125 (81.7%) patients reported eye rubbing. The average Goodman score was 5.8 ± 3.1 and was ≥ 5 in 63.2% of cases. The CAGE score was ≥ 2 in 74.4% of patients. Addiction (p = 0.045) and psychiatric family history (p = 0.03) were more frequent in patients with higher scores. Ocular symptoms and eye rubbing were significantly more frequent and intense in patients with higher scores; Conclusion: Eye rubbing presents addictive-like cognitive and behavioral characteristics in patients with KC or OSD. The eye rubbing cycle could play an essential role in the onset and progression of keratoconus and could be a factor in the maintenance of dry eye.

8.
J Clin Med ; 12(2)2023 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-36675435

RESUMEN

INTRODUCTION: Glaucoma and non-arteritic anterior ischemic optic neuropathy (NAION) are optic neuropathies that can both lead to irreversible blindness. Several studies have compared optical coherence tomography angiography (OCTA) findings in glaucoma and NAION in the presence of similar functional and structural damages with contradictory results. The goal of this study was to use a deep learning system to differentiate OCTA in glaucoma and NAION. MATERIAL AND METHODS: Sixty eyes with glaucoma (including primary open angle glaucoma, angle-closure glaucoma, normal tension glaucoma, pigmentary glaucoma, pseudoexfoliative glaucoma and juvenile glaucoma), thirty eyes with atrophic NAION and forty control eyes (NC) were included. All patients underwent OCTA imaging and automatic segmentation was used to analyze the macular superficial capillary plexus (SCP) and the radial peripapillary capillary (RPC) plexus. We used the classic convolutional neural network (CNN) architecture of ResNet50. Attribution maps were obtained using the "Integrated Gradients" method. RESULTS: The best performances were obtained with the SCP + RPC model achieving a mean area under the receiver operating characteristics curve (ROC AUC) of 0.94 (95% CI 0.92-0.96) for glaucoma, 0.90 (95% CI 0.86-0.94) for NAION and 0.96 (95% CI 0.96-0.97) for NC. CONCLUSION: This study shows that deep learning architecture can classify NAION, glaucoma and normal OCTA images with a good diagnostic performance and may outperform the specialist assessment.

9.
Ophthalmology ; 130(5): 478-487, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36581227

RESUMEN

PURPOSE: To estimate the incidence and assess the risk factors associated with 3 adverse events (AEs) after neodymium:yttrium-aluminum-garnet posterior capsulotomy (Nd:YAG-caps): ocular hypertension (OHT), macular edema (ME), and retinal detachment (RD). DESIGN: Observational cohort study using a nationwide claims database. PARTICIPANTS: Adults who underwent Nd:YAG-caps between 2014 and 2017, with no ocular disease history in the year before. METHODS: Patients who underwent Nd:YAG-caps were identified using data from the French national representative sample and followed up for 12 months postprocedure. The time to AE was assessed using the Kaplan-Meier method. Factors associated with AE were assessed using Cox models. MAIN OUTCOME MEASURES: Neodymium:YAG-caps epidemiology, patients' characteristics, proportion of patients with AE, and hazard ratios (HRs) associated with variables identified as factors associated with AEs. RESULTS: During the study period, 6210 patients received Nd:YAG-caps (7958 procedures). The mean age (± standard deviation) at Nd:YAG-caps was 75.0 (± 10.3) years. The 3-month and 12-month overall AE rates (≥ 1 AE of interest) were 8.6% and 13.3%, respectively. Among patients with ≥ 1 AE of interest, 68.4% of AEs occurred within 3 months post-Nd:YAG-caps. Three-month rates were ≈5% for OHT and ME. Retinal detachment remained ≤ 0.5% over follow-up. Cox models showed that patients with Nd:YAG-caps performed within 1 year after cataract surgery had a higher risk of AEs than those with later Nd:YAG-caps (hazard ratio [HR], 1.314 [1.034-1.669], P = 0.0256), notably ME (HR, 1.500 [1.087-2.070], P = 0.0137). Diabetic patients were more at risk of OHT (HR, 1.233 [1.005-1.513], P = 0.0448) and ME (HR, 1.810 [1.446-2.266], P < 0.0001) than nondiabetic patients. Patients with Nd:YAG-caps performed between 1 and 2 years after cataract surgery were more at risk of OHT than patients with later Nd:YAG-caps (HR, 1.429 [1.185-1.723], P = 0.0002). CONCLUSIONS: According to a national claims database, OHT and ME were the most frequent AEs of interest post-Nd:YAG-caps, mainly observed within 3 months postprocedure, highlighting the need for a close follow-up during this period or a delayed capsulotomy. Diabetes and an early Nd:YAG-caps after cataract surgery were among the main drivers for AE occurrence. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Asunto(s)
Opacificación Capsular , Extracción de Catarata , Terapia por Láser , Cápsula del Cristalino , Edema Macular , Hipertensión Ocular , Desprendimiento de Retina , Adulto , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Extracción de Catarata/efectos adversos , Neodimio , Desprendimiento de Retina/epidemiología , Desprendimiento de Retina/cirugía , Desprendimiento de Retina/etiología , Incidencia , Edema Macular/epidemiología , Edema Macular/etiología , Cápsula del Cristalino/cirugía , Terapia por Láser/efectos adversos , Opacificación Capsular/epidemiología , Opacificación Capsular/etiología , Opacificación Capsular/cirugía , Hipertensión Ocular/epidemiología , Hipertensión Ocular/etiología , Complicaciones Posoperatorias/etiología
10.
J Clin Med ; 11(23)2022 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-36498660

RESUMEN

Purpose: To evaluate the safety and efficacy of Preserflo® microshunt implantation in eyes with refractory glaucoma. Methods: In this retrospective study, a cohort of patients who underwent Preserflo® microshunt implantation between April 2019 and August 2020 for refractory glaucoma were evaluated. At the time of surgery, all eyes had uncontrolled intraocular pressure (IOP) despite maximally tolerated medical therapy and at least one previous failed glaucoma filtering surgery. The primary outcome was a complete success, defined as postoperative IOP ≤ 21 mm Hg with an IOP reduction ≥ 20% and no repeat filtering surgery. The secondary outcome was qualified success, defined as a complete success with the use of antiglaucoma medications. The rates of needling, bleb repair, and postoperative complications were also recorded. Results: Forty-seven eyes with a mean preoperative IOP of 30.1 ± 7.1 mm Hg and a mean of 3.4 ± 1 glaucoma medications were included. The mean number of previous surgeries prior to microshunt implantation was 2.3 ± 1.3. After 1 year, the mean IOP was significantly reduced to 18.8 ± 4.6 mm Hg, with the mean number of medications significantly reduced to 1.4 ± 1.2. Complete success was achieved in 35% of eyes, and a qualified success in 60% of eyes. A decrease in IOP of at least 30% was found in 55% of eyes. Needling or bleb repair was performed in 49% of eyes. Complications were minimal and transient, except for one eye which presented with tube extrusion, and another eye with a transected tube. A repeat glaucoma surgery had to be performed in 17% of eyes. Conclusions: The Preserflo® Microshunt provided moderate success but a significant reduction in IOP, with a good safety profile after one year of follow-up in eyes at high risk for failure of filtering surgery.

11.
Ocul Surf ; 25: 155-162, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35872076

RESUMEN

PURPOSE: To study changes in the subbasal nerve plexus by In vivo confocal microscopy (IVCM) in Sjögren's Syndrome (SS) with or without associated Small Fiber Neuropathy (SFN), in order to prevent diagnostic delay. METHODS: Seventy-one patients with SS, including 19 with associated SFN, 20 healthy volunteers and 20 patients with Meibomian gland dysfunction (MGD) were included in this retrospective case-control study. IVCM was used to investigate subbasal nerve plexus density and morphology. RESULTS: Corneal sensitivity as evaluated with the Cochet-Bonnet aesthesiometer was significantly reduced in the SS group versus the control group (P = 0.026) and the MGD group (P = 0.037). The number of inflammatory cells was significantly increased in the SS group to 86.2 ± 82.1 cells/mm2 compared to the control group (P < 0.001). The density of the subbasal nerve plexus was significantly reduced to 16.7 ± 6.5 mm/mm2 in the SS group compared to the control group (P < 0.005) and the MGD group (P = 0.042). The tortuosity of the nerves in the SS group was significantly increased compared to the control group (P < 0.001) and the MGD group (P = 0.025). The average number of subbasal nerve plexus neuromas was significantly increased in the SS group compared to the control group (P = 0.001), with a significant increase in the average number of neuromas in SS patients with associated SFN compared to SS patients without SFN (P = 0.008). CONCLUSION: IVCM can be useful to detect corneal nerve changes in SS patients and may allow earlier diagnosis of the disease and to consider new therapeutic approaches.


Asunto(s)
Neuroma , Síndrome de Sjögren , Neuropatía de Fibras Pequeñas , Estudios de Casos y Controles , Córnea/inervación , Diagnóstico Tardío , Humanos , Microscopía Confocal , Neuroma/complicaciones , Nervio Oftálmico , Estudios Retrospectivos , Síndrome de Sjögren/complicaciones , Síndrome de Sjögren/diagnóstico , Neuropatía de Fibras Pequeñas/complicaciones
12.
J Clin Med ; 11(4)2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-35207274

RESUMEN

The trabecular meshwork (TM) is the main site of drainage of the aqueous humor, and its dysfunction leads to intraocular pressure elevation, which is one of the main risk factors of glaucoma. We aimed to compare the effects on cytoskeleton organization and extracellular matrix (ECM) of latanoprost (LT) and a Rho-kinase inhibitor (ROCKi) on a transforming growth factor beta2 (TGF-ß2)-induced glaucoma-like model developed from primary culture of human TM cells (pHTMC). The TGF-ß2 stimulated pHTMC were grown and incubated with LT or a ROCKi (Y-27632) for 24 h. The expression of alpha-smooth muscle actin (αSMA) and fibronectin (FN), and phosphorylation of the myosin light chain (MLC-P) and Cofilin (Cofilin-P) were evaluated using immunofluorescence and Western blot. The architectural modifications were studied in a MatrigelTM 3D culture. TGF-ß2 increased the expression of αSMA and FN in pHTMC and modified the cytoskeleton with cross-linked actin network formation. LT did not alter the expression of αSMA but decreased FN deposition. The ROCKi decreased TGF-ß2-induced αSMA and FN expression, as well as MLC-P and Cofilin-P, and stimulated the cells to recover a basal cytoskeletal arrangement. In the preliminary 3D study, pHTMC organized in a mesh conformation showed the widening of the TM under the effect of Y-27632. By simultaneously modifying the organization of the cytoskeleton and the ECM, with fibronectin deposition and overexpression, TGF-ß2 reproduced the trabecular degeneration described in glaucoma. The ROCKi was able to reverse the TGF-ß2-induced cytoskeletal and ECM rearrangements. LT loosened the extracellular matrix but had no action on the stress fibers.

13.
Clin Exp Ophthalmol ; 50(4): 420-428, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35195335

RESUMEN

BACKGROUND: To assess the driving performance and both the visual scanning and driving compensations of glaucoma patients. METHODS: In this case-control pilot study, the driving behaviour and performance of 14 patients with glaucoma and nine healthy age- and sex-similar control subjects were compared in a fixed-base driving simulator. All subjects performed in four scenarios with one to two hazardous situations on urban streets, for a total of five hazards. Measurements taken during the tests included reaction times, longitudinal regulation, lateral control and eye and head movements. RESULTS: Glaucoma patients showed poor driving performance with longer reaction time to hazardous situations than control subjects: pedestrians crossing the road from the left (p < 0.022) or from the right (p = 0.013), and vehicles coming from the left (p = 0.002). Their mean duration of lateral excursion was longer (p = 0.045), and they showed more lane excursions in a wide left curve (p = 0.045). Glaucoma patients also showed a higher standard deviation of time-headway (p = 0.048) with preceding vehicles. Analyses of driving behavioural compensations on curved roads showed that glaucoma patients stayed closer to the centre line in large (p = 0.006) and small (p = 0.025) left curves and on small right curves (p = 0.041). Additionally, on straight roads, as compared to control subjects, glaucoma patients showed longer mean time-headway (p = 0.032) and lower mean speed (p = 0.04). Finally, the glaucoma group exhibited a larger standard deviation of horizontal gaze (p = 0.034) than the control subjects. CONCLUSIONS: In a virtual driving environment, glaucoma patients exhibited unsafe driving behaviours, despite their driving and eye-scanning compensations.


Asunto(s)
Conducción de Automóvil , Glaucoma , Simulación por Computador , Movimientos Oculares , Humanos , Proyectos Piloto , Campos Visuales
14.
BMC Ophthalmol ; 22(1): 64, 2022 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-35144571

RESUMEN

BACKGROUND: In clinical practice, fluctuating vision or decreased quality of vision is a common complaint in DED patients. Our study was designed to investigate the change in dynamic optical quality in dry eye patients after the use of artificial tears. METHODS: Fifty-nine patients with dry eye disease (DED) and 31 control subjects were included in this prospective case-control study. There was no significant difference in age and sex between these two groups (P = 0.342, P = 0.847, respectively). Clinical evaluation of the ocular surface included Ocular Surface Disease Index (OSDI), tear film break-up time (TBUT), lipid layer thickness (LLT), and Schirmer I test. DED patients were divided into two groups, mild (31 patients) and severe (28 patients). The optical quality of the tear film was measured with the Optical Quality Analysis System (OQAS) using the mean objective scatter index (mean OSI), standard deviation of objective scatter index (SD-OSI) and modulation transfer function cut-off (MTF cut-off). After baseline examinations, one drop of artificial tears (ATs, carboxymethylcellulose ophthalmic solution, 0.5%) was instilled in both eyes, and optical quality parameters were measured again at 5 and 30 min following application of ATs. RESULTS: At baseline, the mean OSI was higher in the DED group (0.95 ± 0.54) than in controls (0.54 ± 0.23, P < 0.001). The SD-OSI was also significantly increased in DED patients (0.44 ± 0.71) compared to control subjects (0.12 ± 0.06, P = 0.003). Five minutes after AT instillation, mean OSI and SD-OSI decreased significantly in severe DED patients (P = 0.044; P = 0.018), remained unchanged in mild DED patients, and increased in the control group (P = 0.019; P < 0.001). Thirty minutes after AT instillation, no significant difference in optical quality parameters was observed among the three groups. CONCLUSION: The effect of ATs on optical quality in patients with DED may differ according to the severity of the disease. Measurement of optical quality might be a promising tool to evaluate the effects of various ATs and possibly individualize treatment in DED patients.


Asunto(s)
Síndromes de Ojo Seco , Gotas Lubricantes para Ojos , Estudios de Casos y Controles , Humanos , Lágrimas , Visión Ocular
15.
Sci Rep ; 12(1): 443, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013413

RESUMEN

Increased prevalence of depression has been found in patients with meibomian gland dysfunction (MGD); however, specific conditions of patients suffered from MGD and depression remains unclear. Our aim was to investigate the prevalence of depression in patients with MGD and analyze the risk factors of depression in MGD patients. In this multi-center cross-sectional study, we enrolled 830 MGD patients and 114 normal controls. Demographic information was collected by designed questionnaires about lifestyle habits, systemic and ocular medical history. Ophthalmic examinations were performed in a formal order. Depression symptoms were evaluated with a questionnaire survey using a modified self-rating depression scale (M-SDS). The correlations between the M-SDS score and demographic and clinical information were analyzed. The prevalence of hyperlipidemia and obstructive sleep apnea-hypopnea syndrome (OSAHS) was higher in the MGD group. There were 78 cases (9.4%) with depressive symptoms in the MGD group whereas there were 4 cases (3.5%) in controls. Similarly, M-SDS was higher in the MGD group. The characteristics of depression in the MGD group included: crying spells, sleep disturbance and depressed appetite. Some systemic diseases (OSAHS, allergy, skin disease) and the use of contact lenses was correlated with an increased risk of depressive symptoms in MGD patients.


Asunto(s)
Depresión/epidemiología , Disfunción de la Glándula de Meibomio/psicología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , China/epidemiología , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
16.
Br J Ophthalmol ; 106(4): 467-473, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33328188

RESUMEN

BACKGROUND/AIMS: Dry eye disease (DED) questionnaires would ideally be easy and fast to answer and explore the main aspects of disease burden and satisfaction (efficacy and tolerability) with treatment. This pilot study evaluates the Pentascore questionnaire for routinely assessing DED. METHODS: The Pentascore combines five visual analogue scales (VAS) to assess the intensity and frequency of ocular pain/discomfort, the impact of DED on daily activities and visual tasks and the efficacy and tolerability of ongoing DED treatment(s). This retrospective study compared Pentascore to the Ocular Surface Disease Index (OSDI) questionnaire, fluorescein tear break-up-time, corneal staining and Schirmer I test. RESULTS: For 161 DED patients, the algebraic mean (±SE) for the Pentascore was 52.6±1.8, the mean standardised area of the radar graph was 32.1±1.7 (out of 100) and the mean score for the OSDI was 52.6±1.8. Both questionnaires were highly statistically correlated (R=0.74 for both algebraic score and radar area, p<0.001), and each of five Pentascore VAS was significantly correlated with the OSDI (p<0.05). Corneal staining score (CSS) was correlated with two Pentascore VAS (impact of DED on daily activities and visual tasks), and there was a trend towards a correlation between CSS and the area of the radar graph (p=0.09). CONCLUSIONS: This pilot study indicates that the Pentascore can rapidly and effectively assess the burden of DED and satisfaction with treatments. Compared with the algebraic mean, the estimation of the area of the radar graph likely improves the sensitivity for detecting differences/changes in symptoms and treatment follow-up.


Asunto(s)
Síndromes de Ojo Seco , Radar , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/tratamiento farmacológico , Humanos , Proyectos Piloto , Estudios Retrospectivos , Encuestas y Cuestionarios , Lágrimas , Escala Visual Analógica
17.
Acta Ophthalmol ; 100(1): 45-57, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33938134

RESUMEN

PURPOSE: To conduct a systematic review and meta-analysis on the levels of oxidative stress markers and antioxidants in dry eye disease (DED) compared with healthy subject. METHOD: The PubMed, Cochrane Library, Embase, Science Direct and Google Scholar databases were searched on 10 January 2021 for studies reporting oxidative and antioxidative stress markers in DED and healthy controls. Main meta-analysis was stratified by type of biomarkers, type of samples (tears, conjunctival cells or biopsies), Sjögren's syndrome (SS) (patients with or without SS) and by geographical zones (Asia or Europe). RESULTS: We included nine articles, for a total of 333 patients (628 eye samples) with DED and 165 healthy controls (451 eye samples). There is an overall increase in oxidative stress markers in DED compared with healthy controls (standard mean deviation = 2.39, 95% confidence interval 1.85-2.94), with a significant increase in lipid peroxide (1.90, 0.69-3.11), myeloperoxidase (2.17, 1.06-3.28), nitric oxide synthase 3 (2.52, 0.95-4.08), xanthine oxidase/oxidoreductase (2.41, 1.40-5.43), 4-hydroxy-2-nonenal (4HNE) (4.75, 1.67-7.84), malondialdehyde (3.00, 2.55-3.45) and reactive oxygen species (1.31, 0.94-1.68). Oxidative stress markers were higher in tears, conjunctival cells and conjunctival biopsies of DED than controls. Even if small number of studies were included for antioxidants, catalase seemed to be decreased in DED compared with healthy controls (-2.17, -3.00 to -1.34), with an increase of antioxidants in tears of DED patients without SS (1.13, 0.76-1.49). CONCLUSION: Oxidative stress markers, and probably antioxidants, were dysregulated in DED, establishing a local oxidative environment in tears, conjunctival cells and tissues.


Asunto(s)
Síndromes de Ojo Seco/metabolismo , Estrés Oxidativo/fisiología , Especies Reactivas de Oxígeno/metabolismo , Biomarcadores/metabolismo , Humanos , Oxidación-Reducción
18.
Biomedicines ; 9(10)2021 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-34680542

RESUMEN

Background: This study aimed to compare the corneal nerve structural abnormalities detected using in vivo confocal microscopy (IVCM) in patients with neuropathic corneal pain (NCP) secondary to primary meibomian gland dysfunction (MGD) or autoimmune dry eye (AIDE). Methods: A two-stage retrospective nested case-control study was conducted. First, data from patients with either MGD or AIDE were assessed, selecting only cases with no corneal pain (VAS = 0) or severe pain (VAS ≥ 8). Ocular signs and symptoms of the 238 selected patients were compared between painful and painless cases. Next, painful patients with no corneal damage (Oxford score ≤ 1) were selected within each study group, defining the cases with NCP (i.e., "pain without stain"). IVCM images from all groups were compared with prospectively-recruited healthy controls, focusing on dendritiform cell density and nerve abnormalities (density, tortuosity, microneuromas). Results: AIDE patients had more ocular signs/symptoms than MGD patients. Compared with healthy controls, AIDE-related NCP patients showed increased nerve tortuosity and number of neuromas, whereas MGD-related NCP patients had reduced nerve density and increased number, perimeter, and area of microneuromas. Microneuromas were also observed in healthy controls. Furthermore, a higher number of microneuromas was found in MGD-related NCP compared to AIDE-related NCP or painless MGD. Conclusions: MGD-related NCP was associated with significantly more corneal nerve abnormalities than AIDE-related NCP or healthy controls. Although IVCM can be useful to detect NCP-related corneal nerve changes in such patients, the diagnosis of dry eye disease-related NCP will require an association of several IVCM-based criteria without relying solely on the presence of microneuromas.

19.
Transl Vis Sci Technol ; 10(11): 11, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34495329

RESUMEN

Purpose: Toxic keratopathy (TK) involves complex clinical manifestations and is difficult to differentiate from other ocular surface diseases by conventional slit-lamp examination. The challenge faced by clinicians in confidently diagnosing TK cannot be underestimated. This study aimed to explore the microstructural characteristics and diagnostic parameters by in vivo confocal microscopy (IVCM) in TK. Methods: In this prospective, cross-sectional, comparative study, slit-lamp and IVCM examinations were performed on 20 normal eyes and 54 eyes with TK. Based on slit-lamp imaging, TK subjects were divided into four groups: superficial punctate keratitis (n = 10 eyes), pseudodendritic keratitis (n = 14 eyes), ulcerative keratitis (UK; n = 16 eyes), and ring keratitis (RK; n = 14 eyes). The microstructural characteristics of TK were described according to the following IVCM parameters: basal cell (BC) density, dendritiform cell (DC) density, DC size, corneal nerve fiber (CNF) length, nerve tortuosity, and keratocyte reflectivity. A receiver operating characteristic (ROC) curve model was also formulated to compare the predictive power of BC density, DC density, and CNF length. Results: TK eyes showed significantly higher values for DC density (45.8 cells/mm2; range, 25.0-100.0) compared with normal eyes (24.0 cells/mm2; range, 20.8-32.3; P = 0.013; DC size (111.0 µm2; range, 92.0-137.8) compared with normal eyes (63.7 µm2; range, 47.7-70.3; P < 0.001); nerve tortuosity (0.08; range, 0.05-0.09) compared with normal eyes (0.04; range, 0.02-0.04; P < 0.001); and keratocyte reflectivity. BC density and CNF length values were found to be significantly less than those for normal controls (both P < 0.001). In all subgroups, CNF length appeared to be significantly lower than that of controls (all P < 0.001), and DC density was only statistically significantly higher in the UK (P = 0.003) and RK (P < 0.001) groups. Corneal fluorescein staining had no correlation with the analyzed IVCM parameters (all P ˃ 0.05). However, the increase in DC density and DC size showed negative correlations to CNF length (density: r = -0.325, P < 0.005; size: r = -0.493, P < 0.005), as well as positive correlations to duration and frequency of topical eye drops and DC size (density: r = 0.361, P < 0.05; size: r = 0.581, P < 0.05). A ROC curve showed that CNF length had the strongest predictive power, with the estimated area under the curve being 0.992 ± 0.008. Conclusions: Lower BC density and CNF length, greater DC density and DC size, and greater keratocyte reflectivity were the microstructural characteristics of TK. The role of subbasal nerve, inflammatory response, and limbal stem cells in the progression of TK and the appropriate treatment of different TK stages are future research directions. Translational Relevance: The evaluation of basal cells, subbasal nerve, and dendritiform cells is helpful to our understanding of the pathological process of TK.


Asunto(s)
Enfermedades de la Córnea , Córnea/diagnóstico por imagen , Enfermedades de la Córnea/diagnóstico , Estudios Transversales , Humanos , Microscopía Confocal , Estudios Prospectivos
20.
Clin Exp Ophthalmol ; 49(9): 1027-1038, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34506041

RESUMEN

BACKGROUND: In this systematic review and meta-analysis, we aimed to compare deep learning versus ophthalmologists in glaucoma diagnosis on fundus examinations. METHOD: PubMed, Cochrane, Embase, ClinicalTrials.gov and ScienceDirect databases were searched for studies reporting a comparison between the glaucoma diagnosis performance of deep learning and ophthalmologists on fundus examinations on the same datasets, until 10 December 2020. Studies had to report an area under the receiver operating characteristics (AUC) with SD or enough data to generate one. RESULTS: We included six studies in our meta-analysis. There was no difference in AUC between ophthalmologists (AUC = 82.0, 95% confidence intervals [CI] 65.4-98.6) and deep learning (97.0, 89.4-104.5). There was also no difference using several pessimistic and optimistic variants of our meta-analysis: the best (82.2, 60.0-104.3) or worst (77.7, 53.1-102.3) ophthalmologists versus the best (97.1, 89.5-104.7) or worst (97.1, 88.5-105.6) deep learning of each study. We did not retrieve any factors influencing those results. CONCLUSION: Deep learning had similar performance compared to ophthalmologists in glaucoma diagnosis from fundus examinations. Further studies should evaluate deep learning in clinical situations.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Oftalmólogos , Fondo de Ojo , Glaucoma/diagnóstico , Glaucoma/epidemiología , Humanos , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...