1.
Sci Rep ; 14(1): 9281, 2024 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654008

RESUMEN

Steady-state visual evoked potentials (SSVEP) are electroencephalographic signals elicited when the brain is exposed to a visual stimulus with a steady frequency. We analyzed the temporal dynamics of SSVEP during sustained flicker stimulation at 5, 10, 15, 20 and 40 Hz. We found that the amplitudes of the responses were not stable over time. For a 5 Hz stimulus, the responses progressively increased, while, for higher flicker frequencies, the amplitude increased during the first few seconds and often showed a continuous decline afterward. We hypothesize that these two distinct sets of frequency-dependent SSVEP signal properties reflect the contribution of parvocellular and magnocellular visual pathways generating sustained and transient responses, respectively. These results may have important applications for SSVEP signals used in research and brain-computer interface technology and may contribute to a better understanding of the frequency-dependent temporal mechanisms involved in the processing of prolonged periodic visual stimuli.


Asunto(s)
Electroencefalografía , Potenciales Evocados Visuales , Estimulación Luminosa , Potenciales Evocados Visuales/fisiología , Humanos , Masculino , Femenino , Adulto , Adulto Joven , Interfaces Cerebro-Computador , Corteza Visual/fisiología
2.
Int J Neural Syst ; 29(3): 1850050, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30587045

RESUMEN

Electroencephalographic responses to periodic stimulation are termed steady-state visual evoked potentials (SSVEP). Their characteristics in terms of amplitude, frequency and phase are commonly assumed to be stationary. In this work, we tested this assumption in 30 healthy participants submitted to 50 trials of 60 s flicker stimulation at 15 Hz frequency. We showed that the amplitude of the first and second harmonic frequency components of SSVEP signals were in general not stable over time. The power (squared amplitude) of the fundamental component was stationary only in 30% the subjects, while the power at the second harmonic frequency was stationary in 66.7% of the group. The phases of both SSVEP frequency components were more stable over time, but could exhibit small drifts. The observed temporal changes were heterogeneous across the subjects, implying that averaging results over participants should be performed carefully. These results may contribute to improved design and analysis of experiments employing prolonged visual stimulation. Our findings offer a novel characterization of the temporal changes of SSVEP that may help to identify their physiological basis.


Asunto(s)
Encéfalo/fisiología , Electroencefalografía , Potenciales Evocados Visuales , Percepción Visual/fisiología , Adulto , Femenino , Habituación Psicofisiológica/fisiología , Humanos , Masculino , Estimulación Luminosa/métodos , Factores de Tiempo , Adulto Joven
3.
Front Comput Neurosci ; 10: 129, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28082888

RESUMEN

Steady state visual evoked potentials (SSVEPs) are steady state oscillatory potentials elicited in the electroencephalogram (EEG) by flicker stimulation. The frequency of these responses maches the frequency of the stimulation and of its harmonics and subharmonics. In this study, we investigated the origin of the harmonic and subharmonic components of SSVEPs, which are not well understood. We applied both sine and square wave visual stimulation at 5 and 15 Hz to human subjects and analyzed the properties of the fundamental responses and harmonically related components. In order to interpret the results, we used the well-established neural mass model that consists of interacting populations of excitatory and inhibitory cortical neurons. In our study, this model provided a simple explanation for the origin of SSVEP spectra, and showed that their harmonic and subharmonic components are a natural consequence of the nonlinear properties of neuronal populations and the resonant properties of the modeled network. The model also predicted multiples of subharmonic responses, which were subsequently confirmed using experimental data.

4.
PLoS One ; 9(11): e112099, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25398134

RESUMEN

Efforts to construct an effective brain-computer interface (BCI) system based on Steady State Visual Evoked Potentials (SSVEP) commonly focus on sophisticated mathematical methods for data analysis. The role of different stimulus features in evoking strong SSVEP is less often considered and the knowledge on the optimal stimulus properties is still fragmentary. The goal of this study was to provide insight into the influence of stimulus characteristics on the magnitude of SSVEP response. Five stimuli parameters were tested: size, distance, colour, shape, and presence of a fixation point in the middle of each flickering field. The stimuli were presented on four squares on LCD screen, with each square highlighted by LEDs flickering with different frequencies. Brighter colours and larger dimensions of flickering fields resulted in a significantly stronger SSVEP response. The distance between stimulation fields and the presence or absence of the fixation point had no significant effect on the response. Contrary to a popular belief, these results suggest that absence of the fixation point does not reduce the magnitude of SSVEP response. However, some parameters of the stimuli such as colour and the size of the flickering field play an important role in evoking SSVEP response, which indicates that stimuli rendering is an important factor in building effective SSVEP based BCI systems.


Asunto(s)
Interfaces Cerebro-Computador , Potenciales Evocados Visuales/fisiología , Estimulación Luminosa , Adulto , Color , Femenino , Fijación Ocular , Humanos , Masculino , Factores de Tiempo
5.
PLoS One ; 8(10): e77536, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24204862

RESUMEN

This article concerns one of the most important problems of brain-computer interfaces (BCI) based on Steady State Visual Evoked Potentials (SSVEP), that is the selection of the a-priori most suitable frequencies for stimulation. Previous works related to this problem were done either with measuring systems that have little in common with actual BCI systems (e.g., single flashing LED) or were presented on a small number of subjects, or the tested frequency range did not cover a broad spectrum. Their results indicate a strong SSVEP response around 10 Hz, in the range 13-25 Hz, and at high frequencies in the band of 40-60 Hz. In the case of BCI interfaces, stimulation with frequencies from various ranges are used. The frequencies are often adapted for each user separately. The selection of these frequencies, however, was not yet justified in quantitative group-level study with proper statistical account for inter-subject variability. The aim of this study is to determine the SSVEP response curve, that is, the magnitude of the evoked signal as a function of frequency. The SSVEP response was induced in conditions as close as possible to the actual BCI system, using a wide range of frequencies (5-30 Hz, in step of 1 Hz). The data were obtained for 10 subjects. SSVEP curves for individual subjects and the population curve was determined. Statistical analysis were conducted both on the level of individual subjects and for the group. The main result of the study is the identification of the optimal range of frequencies, which is 12-18 Hz, for the registration of SSVEP phenomena. The applied criterion of optimality was: to find the largest contiguous range of frequencies yielding the strong and constant-level SSVEP response.


Asunto(s)
Interfaces Cerebro-Computador , Potenciales Evocados Visuales/fisiología , Interfaz Usuario-Computador , Adulto , Algoritmos , Electroencefalografía/métodos , Femenino , Humanos , Masculino , Estimulación Luminosa/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA