Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38544470

RESUMEN

PURPOSE: The aim of this study was to evaluate patellar mobility in patients before and after knee arthroplasty (KA) and compare it with that of healthy subjects. It was hypothesised that patellar mobility is diminished in patients with osteoarthritis (OA) and remains unchanged after KA. METHODS: A total of 101 patients (59 females and 42 males) with a mean age of 70.9 ± 9.9 years underwent KA and were compared with 25 healthy individuals (seven females and 18 males) with a mean age of 32.3 ± 9.3 years. Mediolateral patellar displacement was measured by applying a force of 10 N, and the medial and lateral patellar shifts were recorded separately using a validated novel patellostabilometer. Patients were examined preoperatively and at 3 months postoperatively, assessing the range of knee motion and the clinical and functional status based on the Oxford Knee Score (OKS), Kujala Score, subjective Knee Society Score (sKSS), Forgotten Joint Score (FJS) and Western Ontario and McMaster Universities Arthritis Index (WOMAC). RESULTS: Total patellar displacement was 42.1 ± 6 mm for healthy subjects, 31 ± 6 mm before surgery and 32.8 ± 7.8 mm after surgery in osteoarthritic patients (p < 0.01). The mean lateral patellar shift differed significantly between healthy individuals (17.9 ± 4 mm) and osteoarthritic patients (15.1 ± 6 mm) (p < 0.01). The mean medial patellar mobility of healthy individuals (24.2 ± 7 mm) was significantly greater than that of osteoarthritic patients (15.8 ± 4.8 mm) (p < 0.01). All scores improved significantly postoperatively. No correlation was found between patellar mobility and OKS, Kujala Score, sKSS, FJS and WOMAC (r = -0.11). Improvement in patellar mobility also showed no correlation with clinical outcomes according to OKS, Kujala Score, sKSS, FJS and WOMAC (r = 0.08). CONCLUSION: This study has demonstrated reduced patellar mobility in patients with OA. While patellar mobility significantly improved after KA, it may not hold clinical significance (p = 0.04). No impact on clinical outcome can be expected when the presurgical patella mobility is preserved in KA. LEVEL OF EVIDENCE: Level IV.

2.
Artículo en Inglés | MEDLINE | ID: mdl-37285085

RESUMEN

Anomalies of the internal carotid artery (ICA) can increase the risk of haemorrhage during common surgical procedures. The aim of this literature review was to summarize the current state of knowledge on the course of the internal carotid artery in the parapharyngeal space, including the impact of the patient characteristics on the distances between the artery and other anatomical structures, as well as symptoms accompanying the aberrations. Pathologies related to the course of ICA in the parapharyngeal space are common (10%-60% in the general population and up to 84.4% in the elderly). In women, the distances in the oropharynx area are shorter than in men. Although the number of morphological studies is growing, providing more information on this topic, the identified studies differ in the methods and results. Knowledge on the variability in the course of ICA can help identify patients at high risk for the ICA trauma during pharyngeal procedures.

3.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3854-3860, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36907938

RESUMEN

PURPOSE: The purpose of this study was to summarise the current use of outcome measures for the assessment of physical function after knee joint replacement. METHODS: A systematic approach following the PRISMA guidelines was used. Literature search was performed on MEDLINE database via PubMed and on Epistemonikos. Clinical trials (level of evidence I-II) on knee joint replacement reporting data on the 'physical function' domain published between January 2017 and June 2022 were included. Descriptive statistics were used to summarise the evidence. RESULTS: In the 181 articles that met the inclusion criteria, 49 different outcome measurements were used to evaluate clinical outcomes after knee joint replacement. The most frequently adopted patient-reported outcome measures (PROMs) were the Knee Society Score (KSS) (78 studies; 43.1%), the Western Ontario and McMaster Universities (WOMAC) Arthritis Index (62 studies; 34.3%), the Oxford Knee Score (OKS) (51 studies; 28.2%) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) (36 studies; 20%). The most frequently used performance-based outcome measures (PBOMs) were the Timed-Up-and-Go (TUG) test (30 studies; 16.6%) and the 6-min-walk test (6MWT) (21 studies; 11.6%). Among impairment-based outcome measures (IBOMs), range of motion (ROM) was the most used (74 studies; 40.9%). CONCLUSION: There is considerable variation among clinical studies regarding the assessment of the physical function of patients after knee joint replacement. PROMs were found to be the most commonly adopted outcome measures; however, no single PROM was used in more than half of the papers analysed. LEVEL OF EVIDENCE: Level II, systematic review of level I-II studies.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/cirugía , Evaluación de Resultado en la Atención de Salud , Rango del Movimiento Articular , Prueba de Paso , Articulación de la Rodilla/cirugía , Resultado del Tratamiento
4.
Sensors (Basel) ; 23(3)2023 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-36772314

RESUMEN

Mediolateral patella displacement is of interest for diagnostics and clinically relevant research questions. Apart from manual testing, no standardized method is currently available. Proper quantification of patella mobility is necessary to better understand pathologies at the patellofemoral joint. Patella mobility was assessed in 25 healthy individuals using a Patellostabilometer, a new prototype instrument for quantification of the mediolateral patella displacement. The participants underwent measurements of the mediolateral displacement three times using the Patellostabilometer. A maximal force of 10 N was applied for patella movement. Additionally, leg length and circumference of the knee, upper- and lower-leg were measured. Lateral patella displacement of 18.27 ± 3.76 mm (range 15.85-20.64 mm, interquartile range (IQR) of 4.79) was measured. The medial patella displacement showed 24.47 ± 6.59 mm (range 19.29-29.76 mm, IQR of 10.47). The test-retest measurement error was 2.32 ± 1.76 mm (IQR of 2.38 mm), with five outliers. There was greater test-retest variability between the measurements of the medial displacement compared to the lateral one. The test-retest variability reached 7% of the patella displacement. Other parameters provided no significant correlations. Based on the natural patellofemoral mobility, a precise and clinically relevant quantification of patella mobility is allowed.


Asunto(s)
Articulación de la Rodilla , Rótula , Humanos , Rótula/diagnóstico por imagen , Rodilla , Pierna , Soporte de Peso , Fenómenos Biomecánicos
5.
Adv Clin Exp Med ; 28(5): 601-607, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30085430

RESUMEN

BACKGROUND: The proximity of the internal carotid artery to the pharyngeal wall poses a risk of injury during nasopharyngeal surgery. OBJECTIVES: The aim of this study was to assess the distances between the extracranial internal carotid artery (ICA) and the pharyngeal wall. MATERIAL AND METHODS: Measurements were taken on certain levels of the pharynx using computed tomography angiography (angio-CT) scans of 97 patients. One-tailed Student's t-test for independent variables and a comparison of expected values for dependent pairs of observations were applied. RESULTS: The shortest distance between the ICA and the pharyngeal wall was 1.1 mm. The ICA is closer to the pharyngeal wall at the epiglottis apex level (16.46 ±0.89 mm) than to the Eustachian tube (ET) (19.8 ±0.62 mm) (p < 0.0005). In women, the ICA is closer to the ET (19.44 ±0.78 mm) than in men (20.17 ±0.96 mm) (p = 0.04). In women, the right ICA is closer to the pharyngeal wall than the left ICA at the level of the lower margin of the 2nd cervical corpus vertebra (C2) (right: 17.6 ±1.8 mm; left: 20.7 ±1.7 mm) (p = 0.002) and at the level of the epiglottis apex (right: 15.2 ±1.7 mm; left: 17.4 ±1.4 mm) (p = 0.028). The bifurcation of the common carotid artery (CCA) is higher in men (19.48 ±2.19 mm below the C2) than in women (21.82 ±1.02 mm) (p < 0.001). When the bifurcation is at the level of the epiglottis apex, the ICA is closer to the pharyngeal wall (12.3 ±1.69 mm) than in other cases (16.46 ±0.89 mm) (p = 0.005). In men, the higher the bifurcation is, the closer the ICA is to the pharyngeal wall at the level of the lower margin of the C2 (p = 0.003). CONCLUSIONS: The risk of ICA incision during surgery differs between the pharyngeal levels, genders and sides of the neck. The ICA may be much closer to the pharyngeal wall than described in the literature.


Asunto(s)
Arteria Carótida Interna/anatomía & histología , Faringe/anatomía & histología , Arteria Carótida Interna/diagnóstico por imagen , Vértebras Cervicales , Femenino , Humanos , Masculino , Faringe/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
6.
J Vasc Access ; 17(4): e82-4, 2016 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-27056029

RESUMEN

INTRODUCTION: Percutaneously inserted central venous catheters (epicutaneo-cava-catheter - ECC) are widely used in neonatal intensive care, facilitating the parenteral nutrition and the treatment of critically ill newborns. This invasive procedure is regarded as safe and associated with low complication rate. Possible life-threatening complications may result from malpositioning of ECC. Paraspinal misplacement of ECC is one of the most serious complications. CASE PRESENTATION: The authors report a case of misplacement of ECC inserted via left saphenous vein for intravenous feeding. A plane radiograph performed after the procedure showed the line tip at L3-L4 level, supposed to indicate location of the catheter in the vena cava inferior. Three days later, the infant developed neurologic symptoms (lethargy, hypotonia, seizures). Lumbar puncture revealed milky fluid containing parenteral nutrition solution. The infusion was stopped. X-ray with contrast showed the catheterization of the left ascending lumbar vein draining the vertebral venous plexuses. The contrast was highlighting the epidural space. The line was immediately removed resulting in improvement in patient's condition and resolution of all neurological symptoms. There was no sequela of this infiltration and the baby had an uneventful recovery. Follow-up at the age of 12 months showed normal development. CONCLUSIONS: A percutaneous catheter inserted via a lower limb may inadvertently enter the ascending lumbar vein. As previously reported, a catheter inserted via the left lower limb is a risk factor of this malposition. The life-threatening complications may be avoided by careful verification of ECC position (lateral x-ray, contrast examination). Plain radiography alone may not be sufficient for tip localization.


Asunto(s)
Cateterismo Periférico/efectos adversos , Líquido Cefalorraquídeo/química , Recien Nacido Prematuro , Errores Médicos , Soluciones para Nutrición Parenteral/efectos adversos , Nutrición Parenteral/efectos adversos , Remoción de Dispositivos , Espacio Epidural/diagnóstico por imagen , Femenino , Edad Gestacional , Humanos , Recién Nacido , Letargia/líquido cefalorraquídeo , Letargia/inducido químicamente , Hipotonía Muscular/líquido cefalorraquídeo , Hipotonía Muscular/inducido químicamente , Nutrición Parenteral/métodos , Soluciones para Nutrición Parenteral/administración & dosificación , Embarazo , Embarazo Gemelar , Convulsiones/líquido cefalorraquídeo , Convulsiones/inducido químicamente , Punción Espinal , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...