Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Appl Lab Med ; 6(2): 421-428, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33674879

RESUMEN

BACKGROUND: Detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by reverse transcription PCR is the primary method to diagnose coronavirus disease 2019 (COVID-19). However, the analytic sensitivity required is not well defined and it is unclear how available assays compare. METHODS: For the Abbott RealTime SARS-CoV-2 assay (m2000; Abbott Molecular), we determined that it could detect viral concentrations as low as 26 copies/mL, we defined the relationship between cycle number and viral concentrations, and we tested naso- and oropharyngeal swab specimens from 8538 consecutive individuals. Using the m2000 as a reference assay method, we described the distribution of viral concentrations in these patients. We then used selected clinical specimens to determine the positive percent agreement of 2 other assays with more rapid turnaround times [Cepheid Xpert Xpress (GeneXpert; Cepheid); n = 27] and a laboratory developed test on the Luminex ARIES system [ARIES LDT (Luminex); n = 50] as a function of virus concentrations, from which we projected their false-negative rates in our patient population. RESULTS: SARS-CoV-2 was detected in 27% (95% CI: 26%-28%) of all specimens. Estimated viral concentrations were widely distributed, and 17% (95% CI: 16%-19%) of positive individuals had viral concentrations <845 copies/mL. Positive percent agreement was strongly related to viral concentration, and reliable detection (i.e., ≥95%) was observed at concentrations >100 copies/mL for the GeneXpert but not the ARIES LDT, corresponding to projected false-negative rates of 4% (95% CI: 0%-21%) and 27% (95% CI: 11%-46%), respectively. CONCLUSIONS: Substantial proportions of clinical specimens have low to moderate viral concentrations and may be missed by methods with less analytic sensitivity.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/instrumentación , COVID-19/diagnóstico , Juego de Reactivos para Diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación , SARS-CoV-2/aislamiento & purificación , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/virología , Reacciones Falso Negativas , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , ARN Viral/aislamiento & purificación , Reproducibilidad de los Resultados , Estudios Retrospectivos , SARS-CoV-2/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...