Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cell Oncol (Dordr) ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39222177

RESUMEN

Telomeric repeat-containing RNAs (TERRA) and telomerase RNA component (TERC) regulate telomerase activity (TA) and thereby contribute to telomere homeostasis by influencing telomere length (TL) and the cell immortality hallmark of cancer cells. Additionally, the non-canonical functions of telomerase reverse transcriptase (TERT) and TERRA appear to be involved in the epithelial-mesenchymal transition (EMT), which is important for cancer progression. However, the relationship between TERRA and patient prognosis has not been fully characterized. In this small-scale study, 68 patients with colorectal cancer (CRC) were evaluated for correlations between telomere biology, proliferation, and EMT gene transcripts and disease outcome. The proliferating cell nuclear antigen (PCNA) and the epithelial splicing regulatory proteins 1 and 2 (ESRP1 and ESRP2) showed a positive correlation with TERRA, while TA and TERRA exhibited an inverse correlation. Consistent with previous findings, the present study revealed higher expression levels of TERT and TERC, and increased TA and TL in CRC tumor tissue compared to adjacent non-tumor tissue. In contrast, lower expression levels of TERRA were observed in tumor tissue. Patients with high TERRA expression and low PCNA levels exhibited favorable overall survival rates compared to individuals with the inverse pattern. Furthermore, TERRA suppressed CRC tumor growth in severe combined immunodeficiency disease (SCID) mice. In conclusion, our study extends previously published research on TERRA suggesting its potential therapeutic role in telomerase-positive CRC.

2.
Bioengineering (Basel) ; 11(7)2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-39061748

RESUMEN

Tricuspid regurgitation (TR) is a prevalent finding in echocardiography and in case of severe disease is associated with impaired patient outcome. Clover repair offers a surgical solution that can be applied for the treatment of primary and secondary TR. An ex vivo passive beating porcine heart model was created to test a modified clover technique using automated suturing devices and to compare this approach to standard ring annuloplasty. Secondary TR was induced in 10 porcine hearts and the backflow of fluid was assessed. The primary endpoint of this study was regurgitant volume measured in mL at the site right atrial cannula. The baseline regurgitation was 43.3 ± 10.8 mL. The mean regurgitant volume was significantly reduced after all repair procedures to 22.2 ± 5.9 mL with isolated ring annuloplasty, 12 ± 3.9 mL with the modified clover, and 7.6 ± 3.4 mL with the combined procedure (p < 0.0001). The modified clover technique shows how to effectively reduce TR in an ex vivo model. This method may be suitable to facilitate tricuspid repair, especially for totally endoscopic valve surgery.

3.
Medicina (Kaunas) ; 60(7)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39064567

RESUMEN

(1) Background and Objectives: Mitral regurgitation is a common valve disease requiring surgical repair. Even with satisfactory results, repair techniques may underlie subjectivity and variability and require long learning curves. A novel approach, the "Roman Arch" technique, may ease the technical burden. This study assessed an automated suturing device's feasibility and time efficiency for a proposed simplified technique. (2) Materials and Methods: Using the MiStitch™ and MiKnot™ devices (LSI Solutions, Inc., Victor, NY, USA), the suture pattern was performed in a cadaver model. Three surgeons with different expertise levels conducted the procedures. Repair and suture placement times were recorded and analyzed. (3) Results: The modified "Roman Arch" repair was completed on all ten human heart specimens with an average total repair time of 3:01 ± 00:59 min and a trend toward reduced times as experience increased. The study confirmed the technical feasibility with 90% of the attempts rated as rather satisfactory or very satisfactory. (4) Conclusions: The MiStitch™ system effectively facilitated the modified "Roman Arch" repair in an ex vivo setting, suggesting its potential to reduce the technical complexity of mitral valve repairs. Further studies are needed to confirm its efficacy and safety in clinical practice.


Asunto(s)
Insuficiencia de la Válvula Mitral , Válvula Mitral , Técnicas de Sutura , Humanos , Técnicas de Sutura/instrumentación , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Cadáver , Estudios de Factibilidad
4.
Am Heart J ; 269: 158-166, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38163616

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Simulación por Computador , Calidad de Vida , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA