Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Analyst ; 148(21): 5445-5455, 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37750047

RESUMEN

We report for the first time the whole development of a biosensing system based on the Interferometric Optical Detection Method (IODM) enriched with gold nanoparticles (AuNPs), acting as interferometric enhancers for improving the performance of immunoassays. For this purpose, the Lactoferrin sandwich immunoassay model was employed. We describe in detail the entire value chain from the AuNPs production, its functionalization, and characterization with anti-Lactoferrin (anti-LF), the biosensing response of these conjugates as well as their corresponding calculation of the kinetic constants, performance comparison of the readout interferometric signals versus Scanning Electron Microscopy (SEM) and the percentage of the sensing surface covered. Finally, a Lactoferrin sandwich immunoassay was carried out and correlated with Enzyme-Linked ImmunoSorbent Assay (ELISA), and the Limit of Detection and sensitivity figures were obtained. As a result, we demonstrate how the AuNPs act as interferometric amplifiers of the IODM for improving the biosensing response, opening the possibility of being applied in multiple biological detection applications.

2.
Biosens Bioelectron ; 169: 112641, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-32992160

RESUMEN

Food allergens cause worldwide chronic diseases with a great impact on public health. Immunoglobulins E (IgEs) trigger allergic reactions by specifically binding the allergens to which the allergic patients are sensitized. In this scientific work we report for the first time a new optical interferometric in vitro system for the detection of specific IgEs (sIgEs) to the principal peach allergen (Pru p 3) in real serum samples. Interferometric Optical Detection Method (IODM) was employed for reading out the signal of Fabry-Perot based interferometers acting as biotransducers. Pru p 3 was immobilized as bioreceptor onto the sensing surface for detecting the target biomolecules, sIgEs to Pru p 3. Moreover, the demanding low concentration of IgE, compared to other analytes in real serum samples, made it necessary to use nanoparticles (NPs) for two reasons: to collect only the IgEs from the serum sample and to enhance the optical interferometric read-out signal. The methodology was validated in advance by scanning electron microscopy (SEM). Consequently, we report in this article a novel high-performance in vitro detection method to recognize sIgE to molecular allergens by means of silicon dioxide (SiO2) NPs. Finally, this scientific work provides the basis for the in vitro component resolved diagnosis (CRD) of sIgEs to molecular allergens.


Asunto(s)
Técnicas Biosensibles , Hipersensibilidad a los Alimentos , Prunus persica , Alérgenos , Antígenos de Plantas , Reacciones Cruzadas , Hipersensibilidad a los Alimentos/diagnóstico , Humanos , Inmunoglobulina E , Proteínas de Plantas , Dióxido de Silicio
3.
Opt Lett ; 40(10): 2370-2, 2015 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-26393742

RESUMEN

In this Letter, we demonstrate for the first time the experimental capability for the biochemical sensing of resonant nanopillars (RNPs) arrays. These arrays are fabricated over a glass substrate and are optically integrated from the backside of this substrate. The reflectivity profiles of the RNPs arrays are measured by infiltrating different ethanol fractions in water in order to evaluate the optical response for the different refractive indexes, which range from 1.330 to 1.342. A linear fit of the resonant modes shift is observed as a function of the bulk refractive index of the liquid infiltrated. For the type of transducer analyzed, a relative sensitivity of 10017 cm(-1)/Refractive Index Unit (RIU) is achieved, allowing us to reach a competitive Limit of Detection (LoD) in the order of 1×10(-5) RIU.


Asunto(s)
Etanol/análisis , Nanotecnología/instrumentación , Fenómenos Ópticos , Límite de Detección , Microscopía , Agua/química
4.
Opt Express ; 23(10): 12544-54, 2015 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-26074509

RESUMEN

In this work we present an optical technique for characterizing sub-micrometric areas based on reflectivity of the light as a function of angle of incidence for the two pure polarizations s and p, covering a range of angles of incidence from -71.80° to 71.80° with a resolution of 0.1°. Circular areas with a diameter in the order of 600 nm can be characterized, and the spectra for the two polarizations can be obtained with a single measurement. For biosensing purposes, we have fabricated several Bio Photonic Sensing Cells (BICELLs) consisting of interferometers of 1240 nm of SU-8 polymer over silicon. An indirect immunoassay is performed over these BICELLs and compared experimentally with FT-VIS-NIR spectrometry and theoretical calculations. The Limit of Detection (LoD) achieved is comparable with standard high resolution spectrometry, but with the capability of analyzing sub-micrometric domains for immunoassays reactions onto a sensing surface.

5.
Biosens Bioelectron ; 26(12): 4842-7, 2011 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-21733669

RESUMEN

In a previous work we introduced the term Bio-Photonic Sensing Cells (BICELLs), referred to periodic networks of nano-pillar suitable for biosensing when are vertically interrogated. In this article, we demonstrate the biosensing capabilities of a type of micrometric size BICELLs made of SU-8 nano-pillars fabricated over transparent substrates. We verify the biochips functionality comparing the theoretical simulations with the experimental results when are optically interrogated in transmission. We also demonstrate a sensitivity enhancement by reducing the pitch among nano-pillars from 800 to 700 nm. Thus, the Limit of Detection achievable in these types of BICELLs is in the order of 64 pg/mL for 700 nm in pitch among nano-pillars in comparison with 292 pg/mL for 800 nm in pitch when are interrogated by Fourier Transform Visible and Infrared Spectrometry. The experiments exhibited a good reproducibility with a relative standard deviation of 0.29% measured within 8 days for a specific concentration. Finally, BICELLs functionality was tested in real conditions with unpurified rabbit serum for detecting anti-gestrinone antibodies, demonstrating the high performance of this type of BICELLs to detect specific antibodies having immobilized the suitable bioreceptors onto the sensing surface.


Asunto(s)
Anticuerpos/sangre , Técnicas Biosensibles/instrumentación , Gestrinona/inmunología , Nanoestructuras/química , Animales , Anticuerpos/inmunología , Diseño de Equipo , Inmunoensayo/instrumentación , Límite de Detección , Óptica y Fotónica/instrumentación , Polímeros/química , Conejos
6.
Biosens Bioelectron ; 25(12): 2553-8, 2010 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-20478700

RESUMEN

We developed biophotonic sensing arrays of 60x60 microm(2) made of periodic lattices of high aspect ratio SU-8 nano-pillars in order to demonstrate their capability for label-free molecule detection, as well as the sensitivity enhancement in comparison with a single layer of SU-8. The biophotonic sensing arrays, that we call BICELLs (Biophotonic sensing cells), are interrogated vertically by using micron spot size Fourier transform visible and IR spectrometry (FT-VIS-IR). We monitored the surface immobilization of bovine serum albumin (BSA) antigen and anti-BSA antibody (aBSA) recognition. The bioassay exhibits a limit of detection (LOD) in the order of 2 ng/ml limited by the wavenumber uncertainty during the interrogation process. We also estimated and compared the theoretical biolayer thickness with previous results.


Asunto(s)
Técnicas Biosensibles/métodos , Nanoestructuras/química , Animales , Anticuerpos/análisis , Técnicas Biosensibles/instrumentación , Bovinos , Compuestos Epoxi , Diseño de Equipo , Imagenología Tridimensional , Proteínas Inmovilizadas/inmunología , Límite de Detección , Microscopía Electrónica de Rastreo , Nanoestructuras/ultraestructura , Fenómenos Ópticos , Polímeros , Albúmina Sérica Bovina/inmunología , Dióxido de Silicio , Espectroscopía Infrarroja por Transformada de Fourier
7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 72(2 Pt 2): 026102, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16196639

RESUMEN

We study static annihilation on complex networks, in which pairs of connected particles annihilate at a constant rate during time. Through a mean-field formalism, we compute the temporal evolution of the distribution of surviving sites with an arbitrary number of connections. This general formalism, which is exact for disordered networks, is applied to Kronecker, Erdös-Rényi (i.e., Poisson), and scale-free networks. We compare our theoretical results with extensive numerical simulations obtaining excellent agreement. Although the mean-field approach applies in an exact way neither to ordered lattices nor to small-world networks, it qualitatively describes the annihilation dynamics in such structures. Our results indicate that the higher the connectivity of a given network element, the faster it annihilates. This fact has dramatic consequences in scale-free networks, for which, once the "hubs" have been annihilated, the network disintegrates and only isolated sites are left.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...