Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Environ Res ; 220: 115192, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36587721

RESUMEN

This work demonstrates the simultaneous identification of four hazardous heavy metals in water samples, namely copper, lead, cadmium, and mercury. A simple yet selective electrode with the simplest fabrication procedure was used. The modified porous carbon threads coated with gold nanoparticles (AuNPs) was employed as a working electrode. The surface chemistry and morphology of the AuNPs deposited porous carbon thread surface were examined. The electrocatalytic activity of the metals on the Au-modified thread surface was observed using the differential pulse voltammetry (DPV) technique. Furthermore, all four metal ions were detected simultaneously, and no interference was observed. Individual and simultaneous experiments to test the impact of concentration revealed that the limit of detection (LoD) was observed to be 1.126 µM, 1.419 µM, 0.966 µM, 0.736 µM for the Cd2+, Pb2+, Cu2+, and Hg2+ metal ions respectively in a linear concentration range of 10-110 µM of each. Subsequently, the study of pH, interference with coexisting metal ions, repeatability study, and stability analysis was also performed. A real sample analysis utilising three different lake water samples is also carried out to further understand the application of the proposed sensor. A good recovery rate is achieved, and the results are reported. This work paves way for the on-field applicability of the present heavy metal detection platform.


Asunto(s)
Mercurio , Nanopartículas del Metal , Metales Pesados , Oro , Microelectrodos , Fibra de Carbono , Porosidad , Metales Pesados/análisis , Mercurio/análisis , Carbono , Agua , Iones
2.
IEEE Trans Nanobioscience ; 22(2): 301-307, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35788459

RESUMEN

Ammonia is one of the most prominent and hazardous water pollutants; hence its selective and sensitive detection in water is crucial for monitoring water quality and determining its usability. In the present work, a simple, cost-effective electrochemical sensor for the detection of ammonia is presented. Multi-walled carbon nanotubes modified ultra-micro-carbon thread electrode (UME/MWCNT) has been realized. The electro-catalytic activity of ammonia is studied by voltammetry and amperometry techniques and the results are presented. The microscopic characterization of UME/MWCNT for surface morphology analysis was also carried out. Further, the UME/MWCNT based electrochemical sensor was tested for its practical application by exploring various parameters like the effect of scan rate, pH and interference from co-existing bio-chemicals like nitrate, nitrite, phosphate, hydrazine, H2 [Formula: see text] uric acid, ascorbic acid and dopamine along with real sample analysis. The developed sensor can efficiently detect ammonia in a linear range of [Formula: see text] to 1 mM which is well within the permissible safe drinking water limit. The limit of detection (LoD) and limit of quantification (LoQ) obtained for the developed sensor were [Formula: see text] and [Formula: see text] respectively. The negligible interference, good reproducibility, and appreciable recovery values indicated the potential of the developed UME for real-time ammonia detection. As a flexible electrode, UME can be further modified and fabricated as a microfluidic or a miniaturized device for a portable electrochemical sensing platform in future.


Asunto(s)
Amoníaco , Nanotubos de Carbono , Técnicas Electroquímicas , Calidad del Agua , Nanotubos de Carbono/química , Reproducibilidad de los Resultados , Electrodos , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...