Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 20(1)2020 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-31935884

RESUMEN

We developed a new 2.5 µm global shutter (GS) pixel using a 65 nm process with an advanced light pipe (LP) structure. This is the world's smallest charge domain GS pixel reported so far. This new developed pixel platform is a key enabler for ultra-high resolution sensors, industrial cameras with wide aperture lenses, and low form factors optical modules for mobile applications. The 2.5 µm GS pixel showed excellent optical performances: 68% quantum efficiency (QE) at 530 nm, ±12.5 degrees angular response (AR), and quite low parasitic light sensitivity (PLS)-10,400 1/PLS with the F#2.8 lens. In addition, we achieved an extremely low memory node (MN) dark current 13 e-/s at 60 °C by fully pinned MN. Furthermore, we studied how the LP technology contributes to the improvement of the modulation transfer function (MTF) in near infrared (NIR) enhanced GS pixel. The 2.8 µm GS pixel using a p-substrate showed 109 lp/mm MTF@50% at 940 nm, which is 1.6 times better than that without an LP. The MTF can be more enhanced by the combination of the LP and the deep photodiode (PD) electrically isolated from the substrate. We demonstrated the advantage of using LP technology and our advanced stacked deep photodiode (SDP) technology together. This unique combination showed an improvement of more than 100% in NIR QE while maintaining an MTF that is close to the theoretical Nyquist limit (MTF @50% = 156 lp/mm).

2.
Sensors (Basel) ; 18(2)2018 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-29370146

RESUMEN

Abstract: We developed a low parasitic light sensitivity (PLS) and low dark current 2.8 µm global shutter pixel. We propose a new inner lens design concept to realize both low PLS and high quantum efficiency (QE). 1/PLS is 7700 and QE is 62% at a wavelength of 530 nm. We also propose a new storage-gate based memory node for low dark current. P-type implants and negative gate biasing are introduced to suppress dark current at the surface of the memory node. This memory node structure shows the world smallest dark current of 9.5 e-/s at 60 °C.

3.
Open Ophthalmol J ; 2: 102-6, 2008 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-19517034

RESUMEN

High frequency microwave electromagnetic radiation from mobile phones and other modern devices has the potential to damage eye tissues, but its effect on the lens epithelium is unknown at present. The objective of this study was to investigate the non-thermal effects of high frequency microwave electromagnetic radiation (1.1GHz, 2.22 mW) on the eye lens epithelium in situ. Bovine lenses were incubated in organ culture at 35°C for 10-15 days. A novel computer-controlled microwave source was used to investigate the effects of microwave radiation on the lenses. 58 lenses were used in this study. The lenses were divided into four groups: (1) Control lenses incubated in organ culture for 10 to15 days. (2) Electromagnetic radiation exposure group treated with 1.1 GHz, 2.22 mW microwave radiation for 90 cycles of 50 minutes irradiation followed by 10 minutes pause and cultured up to 10 days. (3) Electromagnetic radiation exposure group treated as group 2 with 192 cycles of radiation and cultured for 15 days. (4) Lenses exposed to 39.5°C for 2 hours 3 times with 24 hours interval after each treatment beginning on the second day of the culture and cultured for 11 days. During the culture period, lens optical quality was followed daily by a computer-operated scanning laser beam. At the end of the culture period, control and treated lenses were analyzed morphologically and by assessment of the lens epithelial ATPase activity. Exposure to 1.1 GHz, 2.22 mW microwaves caused a reversible decrease in lens optical quality accompanied by irreversible morphological and biochemical damage to the lens epithelial cell layer. The effect of the electromagnetic radiation on the lens epithelium was remarkably different from those of conductive heat. The results of this investigation showed that electromagnetic fields from microwave radiation have a negative impact on the eye lens. The lens damage by electromagnetic fields was distinctly different from that caused by conductive heat.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...