Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(5)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38690984

RESUMEN

This paper presents the development of a novel high-pressure/high-temperature reactor cell dedicated to the characterization of catalysts using synchrotron x-ray absorption spectroscopy under operando conditions. The design of the vitreous carbon reactor allows its use as a plug-flow reactor, monitoring catalyst samples in a powder form with a continuous gas flow at high-temperature (up to 1000 °C) and under high pressure (up to 1000 bar) conditions, depending on the gas environment. The high-pressure/high-temperature reactor cell incorporates an automated gas distribution system and offers the capability to operate in both transmission and fluorescence detection modes. The operando x-ray absorption spectroscopy results obtained on a bimetallic InCo catalyst during CO2 hydrogenation reaction at 300 °C and 50 bar are presented, replicating the conditions of a conventional microreactor. The complete setup is available for users and permanently installed on the Collaborating Research Groups French Absorption spectroscopy beamline in Material and Environmental (CRG-FAME) sciences and French Absorption spectroscopy beamline in Material and Environmental sciences at ultra-high dilution (FAME-UHD) beamlines (BM30 and BM16) at the European Synchrotron Radiation Facility in Grenoble, France.

2.
J Vis Exp ; (183)2022 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-35695534

RESUMEN

The study of elements with X-ray absorption spectroscopy (XAS) is of particular interest when studying the role of metals in biological systems. Sample preparation is a key and often complex procedure, particularly for biological samples. Although X-ray speciation techniques are widely used, no detailed protocol has been yet disseminated for users of the technique. Further, chemical state modification is of concern, and cryo-based techniques are recommended to analyze the biological samples in their near-native hydrated state to provide the maximum preservation of chemical integrity of the cells or tissues. Here, we propose a cellular preparation protocol based on cryo-preserved samples. It is demonstrated in a high energy resolution fluorescence detected X-ray absorption spectroscopy study of selenium in cancer cells and a study of iron in phytoplankton. This protocol can be used with other biological samples and other X-ray techniques that can be damaged by irradiation.


Asunto(s)
Selenio , Metales , Temperatura , Espectroscopía de Absorción de Rayos X/métodos
3.
JACS Au ; 1(11): 1961-1974, 2021 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-34841412

RESUMEN

The production of carbon-neutral fuels from CO2 presents an avenue for causing an appreciable effect in terms of volume toward the mitigation of global carbon emissions. To that end, the production of isoparaffin-rich fuels is highly desirable. Here, we demonstrate the potential of a multifunctional catalyst combination, consisting of a methanol producer (InCo) and a Zn-modified zeolite beta, which produces a mostly isoparaffinic hydrocarbon mixture from CO2 (up to ∼85% isoparaffin selectivity among hydrocarbons) at a CO2 conversion of >15%. The catalyst combination was thoroughly characterized via an extensive complement of techniques. Specifically, operando X-ray absorption spectroscopy (XAS) reveals that Zn (which plays a crucial role of providing a hydrogenating function, improving the stability of the overall catalyst combination and isomerization performance) is likely present in the form of Zn6O6 clusters within the zeolite component, in contrast to previously reported estimations.

4.
Nanoscale ; 10(34): 16030-16039, 2018 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-30106078

RESUMEN

Heterostructures based on Prussian blue analogues (PBA) combining photo- and magneto-striction have shown a large potential for the development of light-induced magnetization switching. However, studies of the microscopic parameters that control the transfer of the mechanical stresses across the interface and their propagation in the magnetic material are still too scarce to efficiently improve the elastic coupling. Here, this coupling strength is tentatively controlled by strain engineering in heteroepitaxial PBA core-shell heterostructures involving the same Rb0.5Co[Fe(CN)6]0.8·zH2O photostrictive core and isostructural shells of similar thickness and variable mismatch with the core lattice. The shell deformation and the optical electron transfer at the origin of photostriction are monitored by combined in situ and real time synchrotron X-ray powder diffraction and X-ray absorption spectroscopy under visible light irradiation. These experiments show that rather large strains, up to +0.9%, are developed within the shell in response to the tensile stresses associated with the expansion of the core lattice upon illumination. The shell behavior is, however, complex, with contributions in dilatation, in compression or unchanged. We show that a tailored photo-response in terms of strain amplitude and kinetics with potential applications for a magnetic manipulation using light requires a trade-off between the quality of the interface (which needs a small lattice mismatch i.e. a small a-cubic parameter for the shell) and the shell rigidity (decreased for a large a-parameter). A shell with a high compressibility that is further increased by the presence of misfit dislocations will show a decrease in its mechanical retroaction on the photo-switching properties of the core particles.

5.
Rev Sci Instrum ; 89(3): 035109, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29604772

RESUMEN

The construction of a high-temperature reaction cell for operando X-ray absorption spectroscopy characterization is reported. A dedicated cell was designed to operate as a plug-flow reactor using powder samples requiring gas flow and thermal treatment at high temperatures. The cell was successfully used in the reaction of dry reforming of methane (DRM). We present X-ray absorption results in the fluorescence detection mode on a 0.4 wt. % Ni/ZrO2 catalyst under realistic conditions at 750 °C, reproducing the conditions used for a conventional dynamic microreactor for the DRM reaction. The setup includes a gas distribution system that can be fully remotely operated. The reaction cell offers the possibility of transmission and fluorescence detection modes. The complete setup dedicated to the study of catalysts is permanently installed on the Collaborating Research Groups French Absorption spectroscopy beamline in Material and Environmental sciences (CRG-FAME) and French Absorption spectroscopy beamline in Material and Environmental sciences at Ultra-High Dilution (FAME-UHD) beamlines (BM30B and BM16) at the European Synchrotron Radiation Facility in Grenoble, France.

6.
J Environ Qual ; 46(6): 1146-1157, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29293835

RESUMEN

The study of the speciation of highly diluted elements by X-ray absorption spectroscopy (XAS) is extremely challenging, especially in environmental biogeochemistry sciences. Here we present an innovative synchrotron spectroscopy technique: high-energy resolution fluorescence detected XAS (HERFD-XAS). With this approach, measurement of the XAS signal in fluorescence mode using a crystal analyzer spectrometer with a ∼1-eV energy resolution helps to overcome restrictions on sample concentrations that can be typically measured with a solid-state detector. We briefly describe the method, from both an instrumental and spectroscopic point of view, and emphasize the effects of energy resolution on the XAS measurements. We then illustrate the positive impact of this technique in terms of detection limit with two examples dealing with Ce in ecologically relevant organisms and with Hg species in natural environments. The sharp and well-marked features of the HERFD-X-ray absorption near-edge structure spectra obtained enable us to determine unambiguously and with greater precision the speciation of the probed elements. This is a major technological advance, with strong benefits for the study of highly diluted elements using XAS. It also opens new possibilities to explore the speciation of a target chemical element at natural concentration levels, which is critical in the fields of environmental and biogeochemistry sciences.


Asunto(s)
Monitoreo del Ambiente , Espectroscopía de Absorción de Rayos X , Ecología
7.
Phys Chem Chem Phys ; 18(36): 25136-25142, 2016 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-27711527

RESUMEN

We have studied the local structure and valence electronic unoccupied states of thermoelectric CsBi4Te6 and superconducting CsBi3.5Pb0.5Te6 (Tc ∼ 3 K) by extended X-ray absorption fine structure (EXAFS) and X-ray absorption near edge structure (XANES) measurements. The Bi-L3 edge EXAFS reveals wide Bi-Te distance distribution for both compounds indicating complex atomic arrangements in the studied system. The mean square relative displacements (MSRDs) of the Bi-Te bond distances appear largely increased in Pb substituted system due to larger overall local disorder, however, one of the Bi-Te bonds shows a reduced disorder. On the other hand, the Bi-L3 edge XANES is hardly affected by Pb substitution while the Te-L1 edge XANES reveals increased density of unoccupied Te 5p states. This suggests that the carriers introduced by the Pb substitution in CsBi4-xPbxTe6 preferentially goes on Te sites. Similarly, the Cs-L3 edge XANES also shows small changes due to Pb-substitution and reduced local disorder indicated by the reduced width of the Cs-L3 edge white line. We have also shown that the X-ray photoemission spectroscopy (XPS) measurements on various electronic core levels are in a qualitative agreement with the XANES results. These findings are consistent with carrier doping and a reduced disorder in one direction to be likely factors to drive the thermoelectric CsBi4Te6 into a bulk superconductor by Pb-substitution in CsBi4-xPbxTe6.

8.
Rev Sci Instrum ; 87(7): 075115, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27475603

RESUMEN

Original high-pressure glass-like carbon windows developed for x-ray spectroscopy applications are presented. The scientific and technological background of this new technical development is exposed, in particular the limitations of our existing beryllium windows in the context of x-ray absorption spectroscopy (XAS) measurements of solutions with very low solute concentrations at hydrothermal conditions (0.1-200 MPa, 30-600 °C). The benefits of glass-like carbon are exposed, notably its non-crystalline character, the absence of impurities which has been verified by micro-fluorescence laboratory measurements, and its non-toxicity which makes its machining safer. Finite elements mechanical calculations and experimental pressure tests were conducted to determine the pressure limits of windows with two different geometries: cylindrical (thickness 0.5 mm) and inversed-dome shape (thickness 0.5 mm at the tip of the dome). The former break at 150 MPa and the latter show no sign of rupture at 400 MPa. Recent XAS measurements conducted with the new dome shaped windows are presented to show the advantages of the design that allow for the detection of very low concentrations in the transmission mode (down to 30 ppm) and the acquisition of fluorescence XAS spectra in diluted solutions at high pressure. Eventually the perspectives of this original development are discussed.

9.
Proc Natl Acad Sci U S A ; 112(44): 13484-9, 2015 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-26460040

RESUMEN

Current models of the formation and distribution of gold deposits on Earth are based on the long-standing paradigm that hydrogen sulfide and chloride are the ligands responsible for gold mobilization and precipitation by fluids across the lithosphere. Here we challenge this view by demonstrating, using in situ X-ray absorption spectroscopy and solubility measurements, coupled with molecular dynamics and thermodynamic simulations, that sulfur radical species, such as the trisulfur ion S3(-), form very stable and soluble complexes with Au(+) in aqueous solution at elevated temperatures (>250 °C) and pressures (>100 bar). These species enable extraction, transport, and focused precipitation of gold by sulfur-rich fluids 10-100 times more efficiently than sulfide and chloride only. As a result, S3(-) exerts an important control on the source, concentration, and distribution of gold in its major economic deposits from magmatic, hydrothermal, and metamorphic settings. The growth and decay of S3(-) during the fluid generation and evolution is one of the key factors that determine the fate of gold in the lithosphere.

10.
Angew Chem Int Ed Engl ; 53(46): 12426-9, 2014 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-25056683

RESUMEN

Platinum nanoclusters highly dispersed on γ-alumina are widely used as heterogeneous catalysts. To understand the chemical interplay between the Pt nanoparticles, the support, and the reductive atmosphere, we performed X-ray absorption near edge structure (XANES) in situ experiments recorded in high energy resolution fluorescence detection (HERFD) mode. Spectra are assigned by comparison with simulated XANES spectra on models obtained by molecular dynamics (DFT-MD). We propose platinum cluster morphologies and quantify the hydrogen coverages compatible with XANES spectra recorded at variable hydrogen pressures and temperatures. Using cutting-edge methodologies to assign XANES spectra, this work gives unequalled atomic insights into the characterization of supported nanoclusters.

11.
Rev Sci Instrum ; 83(6): 063104, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22755612

RESUMEN

Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Cristalografía por Rayos X/métodos , Fluorescencia , Sincrotrones/instrumentación , Espectroscopía de Absorción de Rayos X/instrumentación , Espectroscopía de Absorción de Rayos X/métodos
12.
J Synchrotron Radiat ; 16(Pt 2): 283-92, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19240341

RESUMEN

A bent-crystal spectrometer based on the Rowland circle geometry has been installed and tested on the BM30b/FAME beamline at the European Synchrotron Radiation Facility to improve its performances. The energy resolution of the spectrometer allows different kinds of measurements to be performed, including X-ray absorption spectroscopy, resonant inelastic X-ray scattering and X-ray Raman scattering experiments. The simplicity of the experimental device makes it easily implemented on a classical X-ray absorption beamline. This improvement in the fluorescence detection is of particular importance when the probed element is embedded in a complex and/or heavy matrix, for example in environmental sciences.


Asunto(s)
Espectrometría por Rayos X/instrumentación , Espectrometría por Rayos X/métodos , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
J Synchrotron Radiat ; 13(Pt 1): 59-68, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16371709

RESUMEN

A new set-up is reported of an indirect cryogenic cooling system for a double-crystal monochromator which runs on the BM30b/FAME beamline at the ESRF (Grenoble, France). This device has been conceived to limit the vibrations on the first diffracting crystal and to maintain it at a constant temperature. These points are crucial for maximizing the beamline stability. Moreover, the relative angular position of the second crystal can be dynamically adjusted by a piezoelectric transducer coupled with a feedback system in order to always be at the maximum of the rocking curve during an X-ray absorption spectroscopy scan. The temperature is stabilized to an accuracy of 0.01 degrees , with two principal consequences. The energy resolution is close to the theoretical value [DeltaE/E = 5.6 x 10(-6) for Si(220)] and the precision of the energy positioning is extremely good even if the power load changes. A feedback mechanism allows a permanent and automatic optimization of the angle between the two crystals of the monochromator. The intensity of the monochromatic beam remains optimized (i) when the intensity of the electron beam decreases in the storage ring and (ii) during an energy scan.


Asunto(s)
Criopreservación/instrumentación , Cristalografía por Rayos X/instrumentación , Óptica y Fotónica/instrumentación , Espectrometría por Rayos X/instrumentación , Sincrotrones/instrumentación , Criopreservación/métodos , Cristalografía por Rayos X/métodos , Ambiente Controlado , Diseño de Equipo , Análisis de Falla de Equipo , Retroalimentación , Nitrógeno , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...