Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Cancers (Basel) ; 15(15)2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37568585

RESUMEN

The objective of this review was to summarize the applications of sonoelastography in testicular tumor identification and inquire about their test performances. Two authors independently searched English journal articles and full conference papers from CINAHL, Embase, IEEE Xplore®, PubMed, Scopus, and Web of Science from inception and organized them into a PIRO (patient, index test, reference test, outcome) framework. Eleven studies (n = 11) were eligible for data synthesis, nine of which (n = 9) utilized strain elastography and two (n = 2) employed shear-wave elastography. Meta-analyses were performed on the distinction between neoplasm (tumor) and non-neoplasm (non-tumor) from four study arms and between malignancy and benignity from seven study arms. The pooled sensitivity of classifying malignancy and benignity was 86.0% (95%CI, 79.7% to 90.6%). There was substantial heterogeneity in the classification of neoplasm and non-neoplasm and in the specificity of classifying malignancy and benignity, which could not be addressed by the subgroup analysis of sonoelastography techniques. Heterogeneity might be associated with the high risk of bias and applicability concern, including a wide spectrum of testicular pathologies and verification bias in the reference tests. Key technical obstacles in the index test were manual compression in strain elastography, qualitative observation of non-standardized color codes, and locating the Regions of Interest (ROI), in addition to decisions in feature extractions. Future research may focus on multiparametric sonoelastography using deep learning models and ensemble learning. A decision model on the benefits-risks of surgical exploration (reference test) could also be developed to direct the test-and-treat strategy for testicular tumors.

2.
Bioengineering (Basel) ; 10(8)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37627802

RESUMEN

Biomechanical studies play an important role in understanding the pathophysiology of sleep disorders and providing insights to maintain sleep health. Computational methods facilitate a versatile platform to analyze various biomechanical factors in silico, which would otherwise be difficult through in vivo experiments. The objective of this review is to examine and map the applications of computational biomechanics to sleep-related research topics, including sleep medicine and sleep ergonomics. A systematic search was conducted on PubMed, Scopus, and Web of Science. Research gaps were identified through data synthesis on variants, outcomes, and highlighted features, as well as evidence maps on basic modeling considerations and modeling components of the eligible studies. Twenty-seven studies (n = 27) were categorized into sleep ergonomics (n = 2 on pillow; n = 3 on mattress), sleep-related breathing disorders (n = 19 on obstructive sleep apnea), and sleep-related movement disorders (n = 3 on sleep bruxism). The effects of pillow height and mattress stiffness on spinal curvature were explored. Stress on the temporomandibular joint, and therefore its disorder, was the primary focus of investigations on sleep bruxism. Using finite element morphometry and fluid-structure interaction, studies on obstructive sleep apnea investigated the effects of anatomical variations, muscle activation of the tongue and soft palate, and gravitational direction on the collapse and blockade of the upper airway, in addition to the airflow pressure distribution. Model validation has been one of the greatest hurdles, while single-subject design and surrogate techniques have led to concerns about external validity. Future research might endeavor to reconstruct patient-specific models with patient-specific loading profiles in a larger cohort. Studies on sleep ergonomics research may pave the way for determining ideal spine curvature, in addition to simulating side-lying sleep postures. Sleep bruxism studies may analyze the accumulated dental damage and wear. Research on OSA treatments using computational approaches warrants further investigation.

3.
Front Bioeng Biotechnol ; 11: 1205009, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37441197

RESUMEN

Aspiration caused by dysphagia is a prevalent problem that causes serious health consequences and even death. Traditional diagnostic instruments could induce pain, discomfort, nausea, and radiation exposure. The emergence of wearable technology with computer-aided screening might facilitate continuous or frequent assessments to prompt early and effective management. The objectives of this review are to summarize these systems to identify aspiration risks in dysphagic individuals and inquire about their accuracy. Two authors independently searched electronic databases, including CINAHL, Embase, IEEE Xplore® Digital Library, PubMed, Scopus, and Web of Science (PROSPERO reference number: CRD42023408960). The risk of bias and applicability were assessed using QUADAS-2. Nine (n = 9) articles applied accelerometers and/or acoustic devices to identify aspiration risks in patients with neurodegenerative problems (e.g., dementia, Alzheimer's disease), neurogenic problems (e.g., stroke, brain injury), in addition to some children with congenital abnormalities, using videofluoroscopic swallowing study (VFSS) or fiberoptic endoscopic evaluation of swallowing (FEES) as the reference standard. All studies employed a traditional machine learning approach with a feature extraction process. Support vector machine (SVM) was the most famous machine learning model used. A meta-analysis was conducted to evaluate the classification accuracy and identify risky swallows. Nevertheless, we decided not to conclude the meta-analysis findings (pooled diagnostic odds ratio: 21.5, 95% CI, 2.7-173.6) because studies had unique methodological characteristics and major differences in the set of parameters/thresholds, in addition to the substantial heterogeneity and variations, with sensitivity levels ranging from 21.7% to 90.0% between studies. Small sample sizes could be a critical problem in existing studies (median = 34.5, range 18-449), especially for machine learning models. Only two out of the nine studies had an optimized model with sensitivity over 90%. There is a need to enlarge the sample size for better generalizability and optimize signal processing, segmentation, feature extraction, classifiers, and their combinations to improve the assessment performance. Systematic Review Registration: (https://www.crd.york.ac.uk/prospero/), identifier (CRD42023408960).

4.
Sensors (Basel) ; 23(5)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36904678

RESUMEN

Sleep posture has a crucial impact on the incidence and severity of obstructive sleep apnea (OSA). Therefore, the surveillance and recognition of sleep postures could facilitate the assessment of OSA. The existing contact-based systems might interfere with sleeping, while camera-based systems introduce privacy concerns. Radar-based systems might overcome these challenges, especially when individuals are covered with blankets. The aim of this research is to develop a nonobstructive multiple ultra-wideband radar sleep posture recognition system based on machine learning models. We evaluated three single-radar configurations (top, side, and head), three dual-radar configurations (top + side, top + head, and side + head), and one tri-radar configuration (top + side + head), in addition to machine learning models, including CNN-based networks (ResNet50, DenseNet121, and EfficientNetV2) and vision transformer-based networks (traditional vision transformer and Swin Transformer V2). Thirty participants (n = 30) were invited to perform four recumbent postures (supine, left side-lying, right side-lying, and prone). Data from eighteen participants were randomly chosen for model training, another six participants' data (n = 6) for model validation, and the remaining six participants' data (n = 6) for model testing. The Swin Transformer with side and head radar configuration achieved the highest prediction accuracy (0.808). Future research may consider the application of the synthetic aperture radar technique.


Asunto(s)
Radar , Apnea Obstructiva del Sueño , Humanos , Postura , Aprendizaje Automático , Sueño
5.
Artículo en Inglés | MEDLINE | ID: mdl-36833691

RESUMEN

Dysphagia is one of the most common problems among older adults, which might lead to aspiration pneumonia and eventual death. It calls for a feasible, reliable, and standardized screening or assessment method to prompt rehabilitation measures and mitigate the risks of dysphagia complications. Computer-aided screening using wearable technology could be the solution to the problem but is not clinically applicable because of the heterogeneity of assessment protocols. The aim of this paper is to formulate and unify a swallowing assessment protocol, named the Comprehensive Assessment Protocol for Swallowing (CAPS), by integrating existing protocols and standards. The protocol consists of two phases: the pre-test phase and the assessment phase. The pre-testing phase involves applying different texture or thickness levels of food/liquid and determining the required bolus volume for the subsequent assessment. The assessment phase involves dry (saliva) swallowing, wet swallowing of different food/liquid consistencies, and non-swallowing (e.g., yawning, coughing, speaking, etc.). The protocol is designed to train the swallowing/non-swallowing event classification that facilitates future long-term continuous monitoring and paves the way towards continuous dysphagia screening.


Asunto(s)
Trastornos de Deglución , Neumonía por Aspiración , Humanos , Anciano , Trastornos de Deglución/etiología , Deglución , Tamizaje Masivo/métodos , Alimentos , Neumonía por Aspiración/etiología
6.
Artículo en Inglés | MEDLINE | ID: mdl-36294072

RESUMEN

Emerging sleep health technologies will have an impact on monitoring patients with sleep disorders. This study proposes a new deep learning model architecture that improves the under-blanket sleep posture classification accuracy by leveraging the anatomical landmark feature through an attention strategy. The system used an integrated visible light and depth camera. Deep learning models (ResNet-34, EfficientNet B4, and ECA-Net50) were trained using depth images. We compared the models with and without an anatomical landmark coordinate input generated with an open-source pose estimation model using visible image data. We recruited 120 participants to perform seven major sleep postures, namely, the supine posture, prone postures with the head turned left and right, left- and right-sided log postures, and left- and right-sided fetal postures under four blanket conditions, including no blanket, thin, medium, and thick. A data augmentation technique was applied to the blanket conditions. The data were sliced at an 8:2 training-to-testing ratio. The results showed that ECA-Net50 produced the best classification results. Incorporating the anatomical landmark features increased the F1 score of ECA-Net50 from 87.4% to 92.2%. Our findings also suggested that the classification performances of deep learning models guided with features of anatomical landmarks were less affected by the interference of blanket conditions.


Asunto(s)
Aprendizaje Profundo , Trastornos del Sueño-Vigilia , Humanos , Postura , Sueño
7.
Artículo en Inglés | MEDLINE | ID: mdl-35627357

RESUMEN

Virtual reality (VR) technology is one of the promising directions for rehabilitation, especially cognitive rehabilitation. Previous studies demonstrated successful rehabilitation in motor, cognitive, and sensorial functions using VR. The objective of this review is to summarize the current designs and evidence on immersive rehabilitation interventions using VR on cognitive- or behavioral-related eating disorders, which was mapped using a VREHAB framework. Two authors independently searched electronic databases, including PubMed, Web of Science, Scopus, CINAHL, EMBASE, and Cochrane Library. Ten (n = 10) articles were eligible for review. Treatments for anorexia nervosa and binge eating disorder/bulimia nervosa were reported through enhanced/experimental cognitive behavior therapy (ECT), cue exposure therapy (CET), and body exposure therapy (BET) via the virtual environment. Some studies reported that the VR effects were superior or comparable to traditional treatments, while the effects may last longer using VR technology. In addition, VR was perceived as acceptable and feasible among patients and therapists and could be valuable for supplementing existing therapies, relieving manpower and caregiver burdens. Future studies may consider incorporating haptic, smell, and biofeedback to improve the experience, and thus the effects of the treatments for the users.


Asunto(s)
Trastorno por Atracón , Bulimia Nerviosa , Trastornos de Alimentación y de la Ingestión de Alimentos , Realidad Virtual , Trastorno por Atracón/terapia , Cognición , Trastornos de Alimentación y de la Ingestión de Alimentos/terapia , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...