1.
Sensors (Basel) ; 21(7)2021 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-33917486

RESUMEN

The ultrasonic phased array as an emerging interactive tool is increasingly used for aerial tactile interaction. However, there is almost no method to achieve remote variable force feedback through the ultrasonic phased array as far as we know. This article presents a force tactile feedback method for teleoperating robot systems that tracks the five fingers and forms a focus on the fingertips. First, the perceived size of the focus depends on the input parameters. The influence of the parameters on the physical output pressure intensity was obtained through physical test experiments. Then, the absolute threshold and difference threshold of human perception were studied through psychophysical experimental methods. Finally, the input parameters were selected according to the experimental results. According to the collected data, the construction of the force regression model was completed, and different parameters were mapped to the perceived intensity. The contact force generated in the actual operation is fed back to the haptic system, and the constructed model automatically adjusts the control parameters to ensure that the user's hand presents a sensory output corresponding to the intensity change. The entire force feedback system is evaluated, and results show that the system shows good perceptual quality.

2.
Artículo en Inglés | MEDLINE | ID: mdl-33917655

RESUMEN

The exoskeleton as functional wearable equipment has been increasingly used in working environments. However, the effects of wearing an exoskeleton on human thermal responses are still unknown. In this study, 10 male package handlers were exposed to 10 °C (COLD) and 25 °C (TEMP) ambient temperatures while performing a 10 kg lifting task (LIFTING) and sedentary (REST) both with (EXO) and without the exoskeleton (WEXO). Thermal responses, including the metabolic rate and mean skin temperature (MST), were continuously measured. Thermal comfort, thermal sensation and sweat feeling were also recorded. For LIFTING, metabolic heat production is significant decrease with the exoskeleton support. The MST and thermal sensation significantly increase when wearing the exoskeleton, but thermal discomfort and sweating are only aggravated in TEMP. For REST, MST and thermal sensation are also increased by the exoskeleton, and there is no significant difference in the metabolic rate between EXO and WEXO. The thermal comfort is significantly improved by wearing the exoskeleton only in COLD. The results suggest that the passive exoskeleton increases the local clothing insulation, and the way of wearing reduces the "pumping effect", which makes a difference in the thermal response between COLD and TEMP. Designers need to develop appropriate usage strategies according to the operative temperature.


Asunto(s)
Dispositivo Exoesqueleto , Regulación de la Temperatura Corporal , Frío , Humanos , Masculino , Temperatura Cutánea , Sudoración
3.
Sensors (Basel) ; 19(21)2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31683855

RESUMEN

Doppler radar for monitoring vital signals is an emerging tool, and how to remove the noise during the detection process and reconstruct the accurate respiration and heartbeat signals are hot issues in current research. In this paper, a novel radar vital signal separation and de-noising technique based on improved complete ensemble empirical mode decomposition with adaptive noise (ICEEMDAN), sample entropy (SampEn), and wavelet threshold is proposed. First, the noisy radar signal was decomposed into a series of intrinsic mode functions (IMFs) using ICEEMDAN. Then, each IMF was analyzed using SampEn to find out the first few IMFs containing noise, and these IMFs were de-noised using the wavelet threshold. Finally, in order to extract accurate vital signals, spectrum analysis and Kullback-Leible (KL) divergence calculations were performed on all IMFs, and appropriate IMFs were selected to reconstruct respiration and heartbeat signals. Moreover, as far as we know, there is almost no previous research on radar vital signal de-noising based on the proposed technique. The effectiveness of the algorithm was verified using simulated and measured experiments. The results show that the proposed algorithm could effectively reduce the noise and was superior to the existing de-noising technologies, which is beneficial for extracting more accurate vital signals.


Asunto(s)
Algoritmos , Radar , Procesamiento de Señales Asistido por Computador , Signos Vitales , Simulación por Computador , Frecuencia Cardíaca/fisiología , Humanos , Respiración , Análisis de Ondículas